Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Schedule \"A\" Part – I to Schedule \"A\" Part – XIX:NOTE: Schedule \"A\" Part – I to Part – XVIII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only |
| 2 | Lumpsum price worked out by the contractor for \"Buildings/Structures\" as listedin Schedule \"A\" Part – I |
| 3 | Lumpsum price worked out by the contractor for \"SITE CLEARANCE& AREA DEVELOPMENT/ EARTH WORK/EXCAVATION\",as listed in Schedule \"A\" Part – II |
| 4 | Lumpsum price worked out by the contractor for \"PILE FOUNDATION\" as listed in Schedule \"A\" Part – III |
| 5 | Lumpsum price worked out by the contractor for \"INTERNAL WATER SUPPLY\", as listed in Schedule \"A\" Part – IV |
| 6 | Lumpsum price worked out by the contractor for \"ROADS, PATH AND CULVERTS\", as listed in Schedule \"A\" Part – V |
| 7 | Lumpsum price worked out by the contractor for \"SEWAGE DISPOSAL\",as listed in Schedule \"A\" Part – VI |
| 8 | Lumpsum price worked out by the contractor for \"AREA DRAINAGE\", as listed in Schedule \"A\" Part – VII |
| 9 | Lumpsum price worked out by the contractor for \"COMPOUND WALL/ GATE\",as listed in Schedule \"A\" Part – VIII |
| 10 | Lumpsum price worked out by the contractor for \"EXTERNAL WATER SUPPLY\",as listed in Schedule \"A\" Part –IX |
| 11 | Lumpsum price worked out by the contractor for \"INTERNAL ELECTRIFICATION\",as listed in Schedule \"A\" Part –X |
| 12 | Lumpsum price worked out by the contractor for \"EXTERNAL ELECTRIC SUPPLY\",as listed in Schedule \"A\" Part – XI |
| 13 | Lumpsum price worked out by the contractor for \"LIGHTENING PROTECTION\",as listed in Schedule \"A\" Part – XII |
| 14 | Lumpsum price worked out by the contractor for \"FIRE FIGHTING SYSTEM\",as listed in Schedule \"A\" Part – XIII |
| 15 | Lumpsum price worked out by the contractor for \"FIRE ALARM & DETECTION SYSTEM\",as listed in Schedule \"A\" Part – XIV |
| 16 | Lumpsum price worked out by the contractor for \"AVIATION LIGHT\",as listed in Schedule \"A\" Part – XV |
| 17 | Lumpsum price worked out by the contractor for \"DG SET\",as listed in Schedule \"A\" Part – XVI |
| 18 | Lumpsum price worked out by the contractor for \"TV & TELEPHONE\",as listed in Schedule \"A\" Part – XVII |
| 19 | Lumpsum price worked out by the contractor for \"ARBORICULTURE\",as listed in Schedule \"A\" Part – XVIII |
| 20 | Schedule \"A\" Part - XIX: (Miscellaneous Items) (Sewage Disposal, Compound Wall/ Gate, Stainless Steel Railing, Internal Electrification, External Water Supply, External Electrification, Fire fighting System, Fire Alarm & Detection System, LIFT, Aviation Light, DG SET, TV & Telephone & Arboriculture) |
| 21 | Sewage Disposal |
| 22 | Supply and layingMS pipe ,socket and spigot ends, vertically cast, class B, in any length, laid in trenches , of size 150mm(6\") dia. Complete. |
| 23 | Supply and fix CI sluice valve of 150 mm dia, double flanged with rubber gasket and nut bolt conforming to IS 14846 PN 1.6 complete. |
| 24 | Supply and layductile iron pipe 100 mm dia. with spigot and socket end centrifugally (spun) cast class K-9 conforming to IS-8329 including provision of specials, such as tees, elbows, bends reducers, taper pieces including testing complete all as specified and directed. |
| 25 | Supply, installation, testing and commissioning of non-clogging vertical submersible pump of5 HP capacity electric driven with chrome steel impeller of minimum flow 500 LPM, head 25 m inside raw sewage tank with float switch, lifting arrangement cabling, installation complete along with the basic requirement of motor protection, including installation with guide rail and lifting chain, testing complete with 2 years maintenance all as specified and as directed |
| 26 | Supply and fixing CI non return Valveof 150 mm diameter , double flanged with rubber gasketand nut bolt conforming to IS 8321 PN1.6 with all fittings and accessories complete. |
| 27 | M&L PVC insulated and FR PVC Round Sheathed, copper conductor cable of size 4 core 4 Sq.mm (flexible) industrial cable, 1100 Volt, conforming to IS 694 for submersible pump complete all as specified and as directed |
| 28 | Supply and fix sheet metal enclosure indoor type feeder panel with provision of fixing incoming and out goingcables with bus bar and cable connection to tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 100 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following all as specified and as directed.Incoming:-(a) MCCB 32 Amps,25 KA - 01 NosOutgoing:-(a) MCB 32 Amp,16 KA TPN - 03 Nos(for two 5 HP pumps+ 01 Spare)(b) MCB 16 Amp,16 KA SPN - 02 Nos(for bldg + 01 Spare)(c) LED Indicating Lamps for each phase with colour Red Yellow Blue for R, Y and B Phases-03 Nos(d)Multifunctional digital Meter. |
| 29 | Earthing complete with galvanized earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32x 6 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 50 mm dia light grade pipe for protection of earth electrode and 20mm dia pipe for watering all as specified and directed and tested on completion. |
| 30 | Supply, installation, testing and commissioning of ultra sonic level sensor with following specifications, Rust proof, maintenance free suitable for up to 6 metre water level depth of OHTs, UG Sump, with dead band of less than 06 meter, IP67 protection, accuracy of 0.25% of F.S. and 4-20 mA current output, No of wires: 4 wire, Beam angle : less than 7.5 degree, capable for working in ambient temperature of zero degree centigrade to 75 degree centigrade, non-condensing at 25 degree centigrade and humidity upto 95% with response time of less than 1 sec with 230V AC to 24 V DC, 50 Hz variation compensation, vertical type mounting on top of OHTs/Sump, Suitable for measuring water/ waste water in sump/OHT with all connections and fixing including clamp, nut-bolt etc complete all as specified and as directed. (Scope of work include all accessories required for the correct operation of sensor) |
| 31 | S & F of electromagnetic type flow meter suitable for 100mm bore pipe, flow range: 0 to 10 Cum / hr liquid ; Raw sewage, wire length : min 10 mtr with IP67 protection, 1.4 KV isolation, accuracy of less than ±3% of MV, linearity of 0.5% of MV , mounting in horizontal position, water pressure : Nominal pressure upto 200 kPA, Should account for the water hammer depending on the valve closure time, current output: 4-20 mA , local indication through LCD display and RS485 Modbus RTU communication protocol, capable of working in ambient temperature of 0 degree centigrade to 75 degree centigrade humidity upto 95% with response time of less than 1 sec with 230V AC to 24 V DC, 50 Hz, Body & flange material : SS304 or higher grade steel , electrode material : Standard haste alloy, including necessary welding work, cutting of existing MS/DI/CI/GI pipe line and inserting new 100 mm boreMS/DI pipe with necessary MS beds and straight pipe upto 6 mtr and connecting with existing pipeline with necessary flanges, nut, bolts, gasket and DI/CI specials complete all as specified as directed. ( The flow meter must have interface with computer/laptop & should be able to monitor & control from computer. Quoted rate shall also include necessary Hardware/Software). |
| 32 | Supplying and fixing smart three phase four wire dual source prepaid energy meters BIS 15884 marked in existing meter board / floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 415 Volt accuracy class 1.0 along with parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition. |
| 33 | Supply, installation testing & commissioning of indoor type PLC (Programmable Logic controller ) / RTU (Remote terminal unit) based Automation, protection Panel for STP with feature of Dual mode communication and wireless Radio frequency based communication (The module should be programmed to automatically toggle between the two communication mode based on the actual signal strength available ), suitable for control and monitoring of upto 4 Nos pumps with electrical parameters, 01 No Energy meter, 01 No electromagneticflow meter with totalizer & 1No ultrasonic level sensor. The panel shall be 500 x 800 x 300 mm front opening type as per MES enclosure guideline as per given specification:- |
| 34 | (i) The panel should be capable of performing following functions in Lift well allas specified and as directed:-(a) Time & level based operation of lift well,(b) online monitoring of electromagnetic flow meter parameters & energy consumption pumps in desired format.(c) Automatic Operation of motor Actuated Butterfly valves/DO sensors/ compressors, etc (if required)(d) Automatic duty cycle based operations of pumps (e) Auto Change over in case of pumps failure(f) Single phasing prevention, phase sequence corrector, voltage unbalancing protectiondata to multiple route and on precise location. |
| 35 | (g) Manual mode operation (all connected sub systems & operations in Sewage treatment plant) from the PLC/RTU based Control panel.(ii) The panel shall have 01 No. PLC/RTU with following specifications:-(a) Discrete input logic(b) Should have suitable No. of Discrete Input and Discrete Output :- Relay/Transistor (c) Protocol supported : isolated serial/ TCP link : Modbus master/Slave and DNP 3.0(d) Standard supported :- ANSI/ISA 12-12-01, CSA C22.2 No 142, CSA C22.1 No 213, EN/IEC 61131-2:2007(e) Web Services :- Integrated Web server(f) 02 Nos isolated RS 485 communication port, 1 Nos. Ethernet communication port with 10BASE-T/100BASE-TX(g) Number of slave :-64 Modbus TCP, & adequate DNP -3 master slaves.(h) PLC/RTU shall be certified by NABL for electromagnetic compatibility and radio disturbance standards as per CISPR22, IEC 61000-4-2:2008, IEC61000-4-3:2010, capable of sending |
| 36 | (iii) Contractor shall consider in quoted rates for any changes in logic within 5 years of installation as per requirement of department.(iv) Certified with IEC 62443(v) Suitable number of indicating LEDs on the panel. (vi) 01 No. SMPs of 6.5A rating (or higher) as suitable according to panel design.(vii) Suitable No. of interposing relays of 220V AC or 24V DC coil rating and 4A contact rating.(viii) Suitable No. of relay cards with operating voltage 24V DC with continuous current of 5A, Card must be of B channel & having 8 relays.(ix) Suitable No. of MCB rating 32A/25A/10A/6A.(x) Suitable No. of illuminated push button & Indicator lamp. |
| 37 | (xi) Suitable No. of Selector switches, Audio visual alarm indicator as per requirement.(xii) 01 No Industrial Ethernet switch with 5 Nos RJ 45 ports, 10/100 Mbps transmission speed.(xiii) LTE router/modem GPRS enabled and having following configuration as minimum:-(a) Ethernet Port/RJ45/ RJ232 or inbuilt in RTU (Remote terminal unit)(b) Security - Zone based firewall, VLAN, DMZ, HTTPS local & remote or inbuilt in RTU( Remote terminal Unit)(c) Communication protocol - Modbus PLC/RTU to TCP support, Modbus master mode or inbuilt in RTU (Remote terminal unit)(d) Routing - DHCP, static routing, port forwarding, traffic routing, static/dynamic DNS, DNS proxy.(e) Operating voltage Range - 24V DC, +/-5%(f) Dual SIM (one standby) via two SIM. |
| 38 | 5 years SIM Data Cost - in RTUs for transmitting data to remote station in dual mode |
| 39 | Note : for item no 27 to 31:Any other product/ service that is needed to complete the automation work at lift well functional shall be considered part of scope of work. OEM/contactor will not get any extra price for additional items for making the SCADA hardware/software operational and functional for the tender duration |
| 40 | Compound Wall/ Gate |
| 41 | S & F Punched tape concertina coil 610 mm dia as per IS - 4454 With galvanised coating and punched tape materials as per IS - 513 deep drawn quality with galvanising coating having medium barbs ( bars length : 24+1mm , pitch between two barbs 35+1mm ) fixed in position and secured to both side of shaped angle iron post , stretched to a length of 6 mtr to achieve 610 mm dia , weighing 9 kg ( +5 % with out handles and spikes) as in fencing to steel post and to another coil / MS Ribs including fixing with special galvanised fasteners such as J clips , C clips , U clips complete all as specified and directed. |
| 42 | Stainless Steel Railing |
| 43 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. |
| 44 | External Water Supply |
| 45 | M&Lfor laying of ductile iron pipe 150mm dia. with spigot and socket end centrifugally (spun) cast class K-9 conforming to IS-8329 including provision of specials, such as tees, elbows, bends reducers, taper pieces (measure separately), including testing and commissioning complete all as specified and as directed. |
| 46 | M&L for laying of ductile iron pipe 100mm dia. with spigot and socket end centrifugally (spun) cast class K-9 conforming to IS-8329 including provision of specials, such as tees, elbows, bends reducers, taper pieces (measure separately), including testing and commissioning complete all as specified and as directed. |
| 47 | M&L for valve chamber of internal size 750x750x750mm comprising of 50mm thick PCC 1:5:10 type E2 foundation, 200mm thick brick wall in CM 1:6, 15mm thick plastering in CM 1:4 internally and externally up to 50mm below GL,100mm thick PCC 1:3:6 type B1 as in copings,3mm thick MS sheet cover with suitable hinges and locking arrangement, painting steel surfaces with two coats of synthetic enamel paint over a coat of primer including necessary earth work and excavation in any type of soil complete all as specified and as directed. |
| 48 | M & L for cutting existing 150 mm steel tubing for alterations or additions necessarily done in position without taking down and inserting Tee of 150 x 150 x 150 mmfor tapping all as specified and directed.(Tapping point shown) |
| 49 | Supply and fix sheet metal enclosure indoor type feeder panel with provision of fixing incoming and outgoing cables with bus bar and cable connection to tinned copper bus bar with insulators suitable for Three Phase and four wire LT AC, 50 Hz, 415 Volts, 200 Amps capacity complete with powder coating, necessary internal electric connection as required and including provision of the following all as specified and as directed.(Pump House Panel) |
| 50 | Incoming:(a) MCCB 4 Pole415 V, 16 kA, 50Hz,microprocessor release100 A capacity 25 kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release -01 No. |
| 51 | Outgoing:(a) MCCB 4 Pole415 V, 16 kA, 50Hz,microprocessor release63 A capacity 16 kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release -03 Nos. (02 Nos. for Fresh water pumps + 01 No. spare)(b) Fully ASD 30 HP starter-02 Nos(c) LED indicating lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases-03 Nos.(d) Multifunctional digital Meter |
| 52 | Internal Electrification |
| 53 | Supply and fixing LED adore lamp for AC 240Volt supply, B22 type, CDS five star, 12 watts of five star rated complete all as specified and as directed. |
| 54 | Supply and fixing ceiling fan, AC single phase 230 V of size 1200 mm sweep, copper wound with complete set and fixtures such as canopy, down rod etc. 5 Star rating, wit brushless direct current motor (BLDC) including making necessary electric connection from ceiling rose to fan connectr with twin core flexible copper wire all as specefied and directed. |
| 55 | S&F Exhaust fan 250 mm sweep or nearest size, plastic body (Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the distrubered surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as spcified and as directed. |
| 56 | S&F Exhaust fan 300 mm sweep, (Heavy duty), complete with louvers suitable for operation on 240 V AC, 50 Hz AC supply fixed on wall including making of neccessary opening, fixing and making good the disturbed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specified and as directed. |
| 57 | S&F Energy efficient LED tube light fitting with tube 5 watts or nearest size, 240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed |
| 58 | S&F Energy efficient LED tube light fitting with tube 10 watts or nearest size 240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed |
| 59 | S&F Energy efficient LED tube light fitting with tube 20 watts or nearest size, 240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed |
| 60 | S&F LED Security light fitting with tube 30W New generation Energy saving &environmental friendly long life made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre wired with 1.0 Sq mm copper conductor cable upto connector including 1.5 m long GI Tubing light grade of 32mm dia bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc complete all as specified and as directed. |
| 61 | S&F concealed in wall Vertical MCB DB double door type, TPN 4 way 415V, 50Hz, IP 43 protection, including provision for fixing MCCB FP as incomer and outgoing circuits MCB SP/TP complete, fill empty way with blanking plates complete all as specified and directed. |
| 62 | S&F RCBO, DP, 240V, 50Hz, 16KA of capacity 20 Amp all as specified and directed. |
| 63 | S&F MCB SPN, 6 to 32 Amps 240 Volts, 10KA, C curve all as specified and directed. |
| 64 | S&F MCB SP, 6 to 32 Amps 240 Volts, 10KA, C curve all as specified and directed. |
| 65 | Supply, install, testing and commissioning integrity of Smart Meter single phase as per BIS 16444 with communication technology including cellular/RF/Hybrid (Cellular + RF ) AC whole current, Smart Energy Meter of rating 10-40 Amps complete as per specifications, meter shall have the ability to communicate with Head End System (HES) on any one of the communication technologies mentioned in IS 16444 Part I (RF/ Cellular) in a secure manner, in case of Cellular based meter, the meter shall accommodate e-SIM / SIM of any service provider, the Smart Meter shall have a dedicated sealable slot for accommodating plug-in type, bi-directional communication module which shall integrate the respective communication technology (RF/PLC/Cellular) with the Smart Meters, leading to easy adaptability for network interfaces (WN/NAN), the Plug-In module shall be field swappable / replaceable complete all as specified and directed. |
| 66 | Note: (i) Meter Specification may please be read in co-junction with the relevant PS clause. |
| 67 | (ii) 15 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for cumulative energy and max demand of software. |
| 68 | (iii) Meter should have connect / disconnect functionality operate able from MDM/ billing software and prepaid features would be configured in MDM/ billing end as per prevalent IS and applicable tariff plan. |
| 69 | (iv) Meter should support communication protocol through RF (4G/5G/NB/IOT) with the software all as required at site and directed (cost of 4G/5G/NB IOT SIM, mapping vending portal charges etc. deemed to be included the unit rate quoted for meter). |
| 70 | (v) Two way communication with DCU/HES. |
| 71 | (vi) Clock synchronisation facility with HES (Head end system). |
| 72 | (vii) In case of RF, communication including different makes of meter shall be such that it should communicate with same DCU directly via mesh network. |
| 73 | (viii) Guarantee of meter shall be 10 years from date of completion. |
| 74 | (ix) The cost of meter shall include DCU / repeater cost in case of RF communication meters. |
| 75 | (x) The OEM shall need to share the Authentication / Encryption keys of the meters along with relevant protocol details with the department. |
| 76 | (xi) A training to handle the smart meter to MES tradesmen shall also be given by professionals. |
| 77 | (xii) The Contractor / OEM will be held responsible for interface with the existing server of any make of MES at Visakhapatnam and testing the system complete all as specified and directed by Engineer-in-Charge. |
| 78 | External Electrification |
| 79 | Supply, install ,testing and commissioning outdoor type 11 KV, 630 Amps, 25 K/1 Sec, outdoor type, both sides extensible, internal are 21 KA/1 Sec floor mounted with internal copper bus bars, SF6 Insulated, completely motorised, 4 Way RMU consisting of 3 Nos. 630 Amps LBS & 1 No. 630 Amps VCBs with SACADA compatible Overload and earth fault protection relay, with all liveparts, bus bars of RMU enclosed in tank to avoid multiple interconnections & sealed for life robotically for three sides and one side manual welded stainless steel tank Grade 304 of minimum 2mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62261-200 and with RMU complete with all accessories such as terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for load break switch ON/OFF, manometer as per with IEC standards 62271-200, and RMU with GI enclosure (120/275 GSM) with RAL 7032 paint and dual coat where top coat (80-100 microns) as PP along with epoxy/polyester hybrid/epoxy zinc rich primer having neutral salt spray hoursas per IS-9227 i.e. 1440, including testing the RMU for internal arc for 21 KA/1 sec cable & tank with AFLR classifications, bidder shall provide type test report to prove compliance to the internal arc fault IAC-AFLR as per IEC 62271-200 with No. of electrical operating cycles as 2000 and short circuit cycles as 50 and with RMU with Integrated bus connected metering cubicle consisting of MFM 0.5 class, PT, FRTU, CT Rating: 100-50/1A 5P10 including inbuilt battery along with battery charger and maintenance free batteries of capacity not less than 20 AH to give backup up to 05 hours with 10 open/close operations, complete all as specified and as directed. |
| 80 | Supply and Installation , testing and commissioning distribution Transformer step down, outdoor type, 11//0.433 KV with HT 3 phase and LT 3 phase 4 wire system copper wound with off load tap changing arrangement on HT side for a variation of secondary voltage +/- 7.5% insteps of 2.5% continuous rating of 800 KVA outdoor type confirming to (IS 1180, level-II) with and including the following: (a) Lifting lugs/ hooks for transformer and tank. (b) Earthing terminal rating and diagram plate. (c) Air release device. (d) Oil filling inlet pipe with plug. (e) Drain outlet pipe with brass gate valve with dummy plug. (f) Conservator with level gauge. (g) Silica gel breather (h) First oil fill up upto the recommended level by manufacturer with new oil conforming to IS 335. |
| 81 | (i) Type of connection : Delta/Star. (j) Type of cooling : ONAN. (k) Vector Group : DYN 11. (l) Type of connecting arrangement : Cable termination boxes on both HT and LT side. (m) Temperature rise over an ambient of 50 degree centigrade maximum.(n) All necessary arrangements with devices for measuring the temperature of core, winding and oil.(o) In addition to the above all standard fittings shall be provided as per IS norms. |
| 82 | All as per Sr no. 53 but 400 KVA capacity |
| 83 | LT FPB made out of CRCA sheet 3.00 mm thick outdoor Pedestal type CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 2000 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(Main Panel No.01) |
| 84 | Incoming: |
| 85 | (a)ACB 4 Pole, 415 V, 50 KA(ICS=ICU=ICW for 1 Sec), with(EDO type) of capacity 1000 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 01 No. |
| 86 | Outgoing: |
| 87 | a) MCCB 4 Pole, 415 V,35 kA (ICS=ICU=ICW for 1 Sec), with(EDO type) of capacity 320 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 01 Nos.(01 for APFC Panel ) |
| 88 | b) MCCB 4 Pole, 415 V,35 kA (ICS=ICU=ICW for 1 Sec), with (EDO type) of capacity 200 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 08 Nos.(04 for BBT and 01 forDG Standby Panel and 03 spare) |
| 89 | c) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers |
| 90 | d) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers |
| 91 | LT FPB made out of CRCA sheet 3.00 mm thick outdoor Pedestal type CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 2000 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(Main Panel No.02) |
| 92 | Incoming: |
| 93 | (a)ACB 4 Pole, 415 V, 50 KA(ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 630 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 01 No. |
| 94 | Outgoing: |
| 95 | a) MCCB 4 Pole, 415 V,35 kA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 200 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 04 Nos.(02 for BBT ,01 stand by 01 for APFC Panel ) |
| 96 | b) MCCB 4 Pole, 415 V,35 kA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 160 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 02 Nos.(01 for 100 KVA DG Standby Panel and 01 spare) |
| 97 | c) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers |
| 98 | d) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers |
| 99 | LT FPB made out of CRCA sheet 3.00 mm thick outdoor Pedestal type CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 500 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(82.5 KVA DG Standby Panel) |
| 100 | Incoming: |
| 101 | (a)MCCB 4 Pole, 415 V, 36 KA(ICS=ICU=ICW for 1 Sec), with(EDO type) of capacity 200 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 01 No. |
| 102 | Outgoing: |
| 103 | a)MCCB 3 Pole, 415 V,25 kA (ICS=ICU=ICW for 1 Sec), with(EDO type) of capacity 63 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 02 Nos.( 01 for Pump house Panel and 01 spare) |
| 104 | b) MCCB 4 Pole415 V, 16 kA, 50Hz,40 A capacity 25kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 05 Nos.(02 for lift panel in bldg 1, 02 for lift panel in bldg 2 , and 01 spare) |
| 105 | c) MCB TPN 20 A \"C\" curve, 415 V, 50 Hz - 04 Nos (02 for Booster pump, 01 for street light, and 01 spare) |
| 106 | d) MCB SPN 20 A \"C\" curve, 230 V, 50 Hz - 03 Nos (02 for common area light and security light in bldg 1 & 2 , and 01 spare.) |
| 107 | e)Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers |
| 108 | f) Timer switch with control relay/contactor - 01 No |
| 109 | g) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers |
| 110 | LT FPB made out of CRCA sheet 3.00 mm thick outdoor Pedestal type CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 500 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(40 KVA DG Standby Panel) |
| 111 | Incoming: |
| 112 | (a)MCCB 4 Pole, 415 V, 35 KA(ICS=ICU=ICW for 1 Sec), with(EDO type) of capacity 125 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 01 No. |
| 113 | Outgoing: |
| 114 | a) MCCB 4 Pole415 V, 16 kA, 50Hz,40 A capacity 25kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 05 Nos.(02 for lift panel in bldg 1, 02 for lift panel in bldg 2 , and 01 spare) |
| 115 | b) MCB TPN 20 A \"C\" curve, 415 V, 50 Hz - 05 Nos (02 for Booster pump, 01 for sewage panel, 01 for street light, and 01 spare) |
| 116 | c) MCB SPN 20 A \"C\" curve, 230 V, 50 Hz - 03 Nos (02 for common area light and security light in bldg 1 & 2 , and 01 spare.) |
| 117 | d)Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers |
| 118 | e) Timer switch with control relay/contactor - 01 No |
| 119 | f) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers |
| 120 | Supply, install, testing and commissioning of factory made APFC panel CPRI approved OEM, free standing floor mounted, dust and vermin proof Automatic Power Factor Correction [APFC] Panel of capacity of 200 KVAR with 6 steps (2x12.5+ 1x25 + 3x50) Compartmentalised, indoor type, fabricated as per IEC 61921 with 2 mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces with minimum IP 43 Ingress Protection suitable for 3 Phase, 415 V & 50 Hz System with MD-XL Capacitor including suitable rated TPN, MCCB, 415 V, 35 KA rupturing capacity as incomer duly controlled by Auto and Manual option including instrumentation such asPower Factor Meter – 1 Nos, Digital type Ammeter of Range 0 to 250 Amps with CTs & Selector Switch – 1 Nos, Digital type Volt Meter of Range 0 – 500 V – 1 Nos, Relay, Auxiliary Contacts, CTS, Phase Indicating LED Lamps [RYB], Selector switches etc., suitable internal wiring with copper cable of suitable size, double stud hinged door, front openable with locking arrangement including interlocking with switch gears complete andpanel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level including connecting up with existing incoming and outgoing cables etc. complete all as specified and as directed. |
| 121 | All as per Sr no. 59 but 100 KVA capacity |
| 122 | Supply and fix Loop in loop out box (minimum size-200mm x 160mm x 98mm)of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, complete. |
| 123 | Supplying and fixing smart single phase two wire dual source prepaid energy meters BIS 15884marked in existing meter board / floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition Smart energy meter with 4G/GPRS based communication meters for remote reading purpose. |
| 124 | Supply and fixing LED Solar street light fitting 36 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete |
| 125 | Disconnecting, Dismantling of the following items and shifting the same to MES Store yard as directed transformer:- 01 No RMU (03 way):- 01 No LT Panel :- 01 No, HT/LT Cables:- 200 mtrs (approx) |
| 126 | Fire fighting System |
| 127 | S & F Ductile pipe with double flanged centrifugally cast (spun) class K-9 of 150 mm dia Heavy gradepipe conforming to IS-8329 including provision of specials, such as tees, elbows, bends reducers, taper pieces, including testing and commissioning. |
| 128 | Supply and fixing of fire fighter booster pump starter manual /automatic controlwith MCCB and phase indicator suitable for 3 phase ,50Hz,440 volts 900LPM ,36 m head all as specified and directed |
| 129 | supply and install Fire Extinguisher ABC Type light weight squeeze grip type confirming to IS:15683 of capacity 6.0 Kg all as specified and directed.Note: (1) Fire extinguisher should equipped with hose of appropriate size and open-close should be with the help of wheel type valve.(2) Fixing arrangement to wall will be included in the quoted rates. |
| 130 | supply and install Fire Extinguisher DRY CHEMICAL POWDERABC Type light weight squeeze grip type confirming to IS:15683 of capacity 4.5 0 Kg all as specified and directed.Note: (1) Fire extinguisher should equipped with hose of appropriate size and open-close should be with the help of wheel type valve.(2) Fixing arrangement to wall will be included in the quoted rates. |
| 131 | supply and install Fire Extinguisher MECHANICAL FOME TYPEconfirming to IS:15683 of capacity9.0 Kg all as specified and directed.Note: (1) Fire extinguisher should equipped with hose of appropriate size and open-close should be with the help of wheel type valve.(2) Fixing arrangement to wall will be included in the quoted rates. |
| 132 | Fire Alarm & Detection System |
| 133 | Supply and fix LED EXIT light double sided with battery back up upto 2 Hrs. of operating voltage 230 V, 50 Hz complete with all as specified and as directed. |
| 134 | LIFT |
| 135 | Design supply, install testing & commissioning passengers lift, speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665, suitable to serve G+ 11 upper floors with AC Variable Voltage &Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive(electric motor driven mechanism), sliding stainless steel doors, automatic rescue device(ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) complete suitable to carry 08 passengers (544 Kg) at a speed of 1.50 M/sec to serve upto 12 floors (G+11 floors).all as specified and as directed |
| 136 | Design supply, install testing & commissioning passengers lift, speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665, suitable to serve G+ 11 upper floors with AC Variable Voltage &Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive(electric motor driven mechanism), sliding stainless steel doors, automatic rescue device(ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) complete suitable to carry 13 passengers (884 Kg) at a speed of 1.50 M/sec to serve upto 12 floors (G+11 floors).all as specified and as directed |
| 137 | Earthing complete with galvanized earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32x 6 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 40 mm dia light grade pipe for protection of earth electrode and 20mm dia pipe medium grade for watering complete. |
| 138 | Material and labour for earth strip galvanised iron of size 32x6 mm including connecting nut bolt all as specified and directed |
| 139 | Aviation Light |
| 140 | Supply and fix aviation obstruction light LED type 15 Wattincluding standard fixing arrangements complete. |
| 141 | Supply and fix time switches 250 V single Phase of 32 Amp rating with contactor fitted inside steel enclosure complete Energy saving programmable aviation control switch suitable to operate on single phase AC voltage 160-260 V, 50 Hz, housed in a sheet metal enclosure, powder coated, confirming to IP 54 of IS :12063/1987(1999), having programming features of default (company programmed) / define (user programme) to switch on & off the aviation light load for whole the year with 24 programme spreads over year, inbuilt real time clock with battery backup up to 5 years, 2x20 character LCD display for setting, inbuilt by-passing switch when require manually controls, inbuilt a photo sensor circuit option for on the street light when ambient light level falls 40 lux, and off when goes 80 lux with by-passing switch arrangement. Entire system shall be protected for over voltage (260V), under voltage (160V), over load, voltage spikes & surges and completed with suitable MCB, heavy contactor & duly wired upto input/output terminals complete. |
| 142 | DG SET |
| 143 | Supply and installation testing commissioning of silent Diesel Engine driven generating set 415Volts, 3 phase, 4 wire,with AMF panel as per CPCB-IV + norms engine as per IS : 10001/10002 and alternator as per IS: 13364 complete with relay panel for automatic starting on mains failure, control panel having meters, sound etc. of capacity 82.5 KVA. all as specified and as directed |
| 144 | Supply and installation testing commissioning of silent Diesel Engine driven generating set 415Volts, 3 phase, 4 wire,with AMF panel as per CPCB-IV + norms engine as per IS : 10001/10002 and alternator as per IS: 13364 complete with relay panel for automatic starting on mains failure, control panel having meters, sound etc. of capacity 40.0 KVA. all as specified and as directed |
| 145 | TV & Telephone |
| 146 | Supply and fix factory fabricated GI metal flush boxes suitable for 1-2 module complete all as specified and as directed. |
| 147 | Supply and fix RJ 11 telephone socket 1 module withcoverplate complete all as specified and as directed. |
| 148 | Supply and fix TV socket 1 module withcoverplate complete all as specified and as directed. |
| 149 | Supply and fix RJ 45 jack internetsocket 1 module withcoverplate complete all as specified and as directed. |
| 150 | Arboriculture |
| 151 | Supply & Planting Korean carpet grass by piece turfing including preparion of ground complete all as specified and as directed |
| 152 | Supply only appoved loose soil/sweet earth best quality for plant complete all as specified and as directed |
| 153 | Supply only approved vermi compost of the best qualitycomplete all as specified and as directed |
| 154 | Supply of approved manure (cow dung) complete all as specified and as directed |
| 155 | Supply & Planting Ashoka Plant including preparation complete all as specified and as directed |
| 156 | Supply & planting Royal palm tree plant including preparation complete all as specified and as directed |
| 157 | PHASE - IIIOUTSOURCING OF 13 PASSENGERS LIFT – 03 NOS AND 08 PASSENGERS LIFTS – 06 NOS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM NO. 71.00 & 72.00 DURING FIRST YEAR OF DEFECT LIABILITY PERIOD |
| 158 | Outsourcing of services for operation of passenger lifts (06 Nos. of 8 passengers lift & 03 Nos of 13 passengers lift) any type and make to serve S+11 floors, during First Year of the two year Defect Liability Period by providing services of One Lift Operator (Semi Skilled) in 01 shift on all the days including Sunday & holidays including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed by the Engineer-in-charge (Shift Details: 365 Days x 3 Building x 1 Shift = 1095 Shifts) |
| 159 | PHASE - IVOUTSOURCING OF 13 PASSENGERS LIFT – 03 NOS AND 08 PASSENGERS LIFTS – 06 NOS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM NO. 71.00 & 72.00 DURING SECOND YEAR OF DEFECT LIABILITY PERIOD |
| 160 | Outsourcing of services for operation of passenger lifts (06 Nos. of 8 passengers lift & 03 Nos of 13 passengers lift) any type and make to serve S+11 floors, during Second Year of the two year Defect Liability Period by providing services of One Lift Operator (Semi Skilled) in 01 shift on all the days including Sunday & holidays including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed by the Engineer-in-charge (Shift Details: 365 Days x 3 Building x 1 Shift = 1095 Shifts) |
| 161 | PHASE - VComprehensive maintenance of electrically operated Passenger Lifts (06 Nos. of 8 passengers lift & 03 Nos of 13 passengers lift) as per serial item no. 71.00 & 72.00 of BoQ to serve S+11 floors complete including all connected components of lift during 1st year after expiry of Defect liability period all as specified and directed. |
| 162 | PHASE - VIComprehensive maintenance of electrically operated Passenger Lifts (06 Nos. of 8 passengers lift & 03 Nos of 13 passengers lift) as per serial item no. 71.00 & 72.00 of BoQ to serve S+11 floors complete including all connected components of lift during 2nd year after expiry of Defect liability period all as specified and directed. |
| 163 | PHASE - VIIComprehensive maintenance of electrically operated Passenger Lifts (06 Nos. of 8 passengers lift & 03 Nos of 13 passengers lift) as per serial item no. 71.00 & 72.00 of BoQ to serve S+11 floors complete including all connected components of lift during 3rd year after expiry of Defect liability period all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail