| 1 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking outPosts embedded inConcrete, brick work, masonry, etc. embedded portion and making good disturbed ground etc complete all as specified and directed. |
| 2 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars, debries etc complete all as specified and directed. |
| 3 | M&L for brick work with fly ash bricks, straight or curved on plan to any radius, built in cement mortar 1:6 using old size bricks complete all as specified and directed. |
| 4 | M & L for 15 mm thick rendering intwo layers, 5mm thick in CM 1:4 mixed with WPI @ 3% by weight of cement over a coat of 10mm thick in CM 1:4. on concrete or brick wall surfaces, finished even and smooth without using extra cement (IWPC measured and paid separately) completefine aggrigate used natural river sand complete all as specified and directed. |
| 5 | Supply only integral water proofing compound, complete all as specified and directed. |
| 6 | M&L for preparing new plastered surfaces of walls and applying Two coats of cement based paint complete all as specified and directed. |
| 7 | Dismantling fencing wire mesh, any type or any description etc complete all as specified and directed. |
| 8 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm getting out soft/loose soil ,etc complete all as specified and directed. |
| 9 | M&L PCC 1:4:8 Type D2 using 40mm graded stone aggregate Cement concrete in foundations, filling and mass concrete,etc complete all as specified and directed. |
| 10 | M&L posts and struts in fencing including cutting tops to shape as directed, drilling holes, matching for wire etc, flat iron fillets (for securing wire mesh etc) including allnecessary drilling, bolting or reveting etc an simillar work.s,etc complete all as specified and directed. |
| 11 | M&L for plain Cement Concrete Type C1 1:3:6 (using 20 mm graded stone aggregate) in foundation filling, mass concrete and similar works,etc complete all as specified and directed. |
| 12 | Supply and fixing 5.60mm (over all dia) PVC coated GI chain link fencing having 2.8mm dia GI wire and 1.4mm thick PVC coating and size of mesh 60mm X 60mmincluding line bar 8mm dia round 4 Nos full length of straights, rails strading bolts etc.complete all as specified and directed. |
| 13 | S&F MS bolts, screw (machine made( with hexagonal or spare head one end and screwed the other, or screwed bolts ends, each screwed end to be fitted with washer and one hexagonal or squaremeter 5 cm long,etc complete all as specified and directed. |
| 14 | S&F in repairs galvanised, 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacting and straining and fixing to any type of standard rails, including securing or tying at crossing etc complete all as specified and directed. |
| 15 | M&L two coats of synthetic enamel paint over a coat of reoxide primer including preparation of any description over 10cm width or girth,etc complete all as specified and directed. |
| 16 | S & F for Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc. complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing, Fe 410-W (Gde-E-250) quality-A,etc complete all as spfd and directed. |
| 17 | S & F for Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, Thickness of sheet in 1.60 mm, etc complete all as spfd and directed. |
| 18 | S&F for 60mm thick M-35 grade factory made rubber moulded precast concrete interlocking paver block in grey cement with pigments and of approved size and shape and conforming to IS 15658-2006, laid over 50mm thk sand bedding layer laid to true line, level watered and mechanically compacted,including dismantling Stone slabs/ tiles, floors, paths, aprons etc any description or thickness and complete all as specified and directed. |
| 19 | M&L chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick with grey cement and pigment, machine pressed,setjointed and pointed in neat cement slurry in floors id over 15 mm thick screed bedding layer in CM 1:6 complete,including dismantling chequered floor tiling incl cement mortar bedding, etc complete all as specified and directed.. |
| 20 | Demolition of cement concrete (Unreinforced) in ground floors and pavings n exc 15cm thickness (Below or above Ground level),etc complete all as specified and directed. |
| 21 | Material and labour for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required completeall as specified and as directed. |
| 22 | M&L for PCC type E2 1:5:10 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 23 | Taking down cement plaster on brick or stone walls incl racking out joints, hacking for key, scrubbing down with water etc.complete all as specified and directed. |
| 24 | Cutting into existing manholes for connecting new drains of internal dia of pipe 150mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required, complete all as specified and directed. |
| 25 | Cutting into existing manholes for connecting new drains of internal dia of pipe 200 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required, complete all as specified and directed. |
| 26 | M & L salt glazed stone wave gully traps square or rounded mouthed tape & fix 150 x 150 mm fixed in cement concrete complete in repairs,etc complete all as specified and directed. |
| 27 | M&L Plain cement concrete (1:3:6) type C-2 (40mm graded stone aggregate) as concrete bed to drain pipes, 110mm bore, including packing under, and haunching against the sides of pipes after they are laid and tested including demolition of exisitng concrete bed, haunching andpipe, etc complete all as specified and directed. |
| 28 | M & L Reinforced cement concrete pipes, 150mm bore, class NP2, conforming to IS 458, laid and jointed complete with collarslaid in trenchesincluding taking down existing pipes any type, after laying of pipe lines making the existing levels of sorroundings,complete all as specified and directed. |
| 29 | M & L Reinforced cement concrete pipes, 200mm bore, class NP2, conforming to IS 458, laid and jointed with collarslaid in trenches including taking down existing pipe any type etc.after laying of pipe lines making the existing levels of sorroundings,complete all as specified and directed. |
| 30 | S & F 110 mm bore PVC (SWR) pipe single socketed,in any length with rubber ring joints, laid in trenches or in floors or fixed to wall complete all as specified and directed. |
| 31 | Demolition of cement concrete (Reinforced) of any description in any position , etc complete all as speified and directed. |
| 32 | S & F TMT bars 6mm dia and over upto and incl 8mm dia as in reinforcement, incl binding with and incl tying with MS wire (annealed) not less than 0.9mm dia,etc complete all as speified and directed.. |
| 33 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, inlcuding cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 34 | M & L PCC 1:2:4, type B1 (using 20 mm graded stone aggregate as in pre-cast cover slabs for manholes/drains incl necessary form work set in CM 1:4 all as specified. (Reinforcement will be measured & paid separately), etc complete all as speified and directed. |