| 1 | Sch \"A\" Part I(Building Work) |
| 2 | Provn of Compressor room for IRP equipments all specified and directed by Engr-in-Charge. |
| 3 | Provn of Semi Underground water Sump of 50000 Gallone Capacity all as specified and directed by Engr-in-Charge. |
| 4 | M&L for construction of brick masonry valve pit of size 90x90x90 cm (internal dimension) one brick thick wall built in CM (1:4) on 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in foundation, and 15mm thick rendering in cement mortar (1:4) both externally and internally, plaster shall be up to 15cm below GL, providing valve pit cover made of 3.15mm thick MS sheet/plate, including provision of hinges, handle and locking arrangement including 40x40x5mm angle iron frame fixed on top of valve pit by means of MS hold fast 40x5mm and 150mm long, embedded in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) including two coats of anti-corrosive paint over a coat of red oxide zinc Chrome primer and necessary earth work in soft/loose soil complete all as specified and directed. |
| 5 | Sch \"A\" Part II(Scada System) |
| 6 | Designing, Supplying, Developing, lnstallation, Integrating and Commission 06 Nos STPs (a. STP JRC Cap - 1.00 MLD, b. STP No. 42 Cap - 348 KLD, c. STP MH Cap - 150 KLD, d. STP Lal Phatak Cap - 461 KLD, e. STP 80 ORs Cap- 90 KLD, f. STP Hill Track Road Cap- 1.2 MLD ) SCADA System along with various Automation equipment for STP as indicated and as per details attached. The STP SCADA system shall comprise of following:(a) Central Monitoring Station (CMS) with personal computer with latest processor and monitor 13th generation intel (R) core, window 11, i7 processor, (b) 2 KVA UPS with two hours backup.(c) Colour laser Printer.multifunctional two No for A-3 & A-4 sheets with high qualitytwo sided color printing, scanning and copying, print speed 25 PPM, USB, WiFi , wirelesssuuitable for scan to PDF, from USB flash drivwe port Make : HPor equivalent(d) Server (All 6 STPs Data can be monitored at a time). (e) Data Gateway.(f) SCADA software which can be operated, programmed and modified by agencies other than developer. (g) PLC/ Microprocessor Controllers with indoor/ outdoor applications for water sensing display, pump operation with RTU / without RTU or Microprocessor controller and microprocessor transmitter.(h) Suitable communication system including payment of bills to telecom service provider. (j) Pressure transmitters as per site requirement(k) Ultrasonic sensors, (l) Flow-meters and switches(m) Online Continuous Efluent Monitoring System (OCEMS) for both raw and treated water(COD, BOD, TSS, PH, Amonia, temprature etc ) |
| 7 | Note:- (i) Design of Communication System shall be done by the bidder. Cloud based server/ data storage/ communication shall not be used and only local server based system shall be designed. (ii) The cost of each item shall also be attached to arrive at pricing in case of some addition/ reduction at site. (iii) Operating system, system software and programming shall not be intellectual property of any agency. (iv)The memory in the hard disk shall be suitable for six months data. The backup storage device/ devices shall be provided for archiving of data more than six months old upto five years. (v) In case of addition of installations, the system shall be capable of integrating the same. (vi) The responsibility of the agency is restricted to intimate mechanical and electrical failures such as failure of pumps, compressors, etc. Such repairs shall be carried by MES. (vii) Operation and maintenance charges to be paid separately. (viii) The SCADA system should have provision of both manual and automatic operation of installations. |
| 8 | Note: Component of Payment for Item No. 06(a) Successfully installation and operation of SCADA on completion of work-71.44% of quoted rate of item No. 06(b) 1st Year under defect liability period after completion :- 1.44% of quoted rate of item No. 1(c) 2nd year under defect liability period after completion - 1.44% of quoted rate of item No. 1(d) 1st year after defect liability period after completion - 2.85% of quoted rate of item No. 1(e) 2nd year under defect liability period after completion-2.85% of quoted rate of item No. 1(f) 3rd year after defect liability period after completion - 2.85% of quoted rate of item No. 1(g) 4th year after defect liability period after completion - 2.85% of quoted rate of item No. 1(h) 5th year after defect liability period after completion-3.57% of quoted rate of item No. 1(j) 6th year after defect liability period after completion-3.57% of quoted rate of item No. 1(k)7th year after defect liability period after completion-3.57% of quoted rate of item No. 1(l)8th year after defect liability period after completion-3.57% of quoted rate of item No. 1 |
| 9 | Sch \"A\" Part III (Electrification) |
| 10 | Supply and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 25 sqmm x 3.5 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles etc, complete all as specified and as directed. |
| 11 | All as per item No. 10 above, but sec. area 16 sqmm x 4 Core. |
| 12 | All as per item No. 10 above, but sec. area 6 sqmm x 2 Core. |
| 13 | M&L earthing complete with GI earth plate electrode of size 60cm x 60cm x 6.0mm thick burried directely in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate at a depth not less than 1.5m below normal ground level connected to and including earth lead of GI strip 32 x 6 mm of length required at site by means of bolts, nuts and check nuts and washers etc made of GI and connected to Earthing test point and earth dolly all as shown in elect plate No 5 SSR Pt-I including all necessary excavation earth work, PCC chamber, chamber cover with handle (PCC 1:2:4) including 40mm dia protection pipe and 20mm dia watering pipe and wire mesh funnel etc complete all as specified and as directed. |
| 14 | S&F in repairearth continuity conductor GI strip 32x6mm size complete all as specified and directed (only for existing earthings). |
| 15 | Supply fixing testing and commissioning submersible cable round/flat 4.0 sqmm x 3 core PVC insulated and PVC sheathed with multi stranded copper conductor 1100 volts grade fixed to submersible motor column pipe using suitable size of clamps made out of stainless steel flat of size 20x2 mm with steel nuts bolts & washer foe every column pipe of 3 mtr length all as specified and directed. |
| 16 | All as per above item no 15but 2.5 sqmm 3 runs. |
| 17 | Supply,install, test and commission, outdoor type ,LT panel ,cubicle type, factory fabricated,CPRI approved,panel board made with 3.15 mm thick CRCA Sheet , weather and vermin proof , floor mounted type, IP-52 protection Class,mounted on MS angle of size 50x50x6mm and height 600mm from floor/ ground grouted in PCC comprising of copper bus bar mounted on hygroscopic insulator housed in separate chamber covered with R-Y-B and black PVC heat shrinkable sleeve, mounted on Hold fastener bolt, nuts and washers. Front opening hinged door with locking arrengement including Panel wiring of required size cable,Provision of cable glands,Separate compartment to accomodate MCBs, measuring instruments, Bus bar and cable gallay ,proper arrangements for ventilation complete with provn for connecting earthing at both sides of panel board comprises as following:-INCOMER:- (i) MCCB 4 pole 160A, 415V, 50 Hz 25KA with Microprocessor release adjustable type.OUTGOING:-(i)MCCB 40 Amp 4 pole, 415V, 50 Hz, 25KA-04(i)MCCB 20-35 Amp 4 pole, 415V, 50 Hz, 25KA-06 Nos. (iii) Fully automatic start delta starter suitable for 10 HP pump set-02 Nos (iv) DOL starter suitable for air blower & air compressor motor upto 5 HP-05 Nos (v) DOL starter suitable forupto 7.5HP monoblock pump set - 02 NosMETERING & INDICATION:- (i) Ammeter, Digital type, 0-200 Awith CTs- 01 set. (ii) Voltmeter, Digital type 0-500V with - 01 set. (iii) R-Y-B phase indicating lamps with 3 Nos. - 01 set. (iv) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled.(v) single phase preventer(vi) automatic phase corrector |
| 18 | M&L for pointwiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in and including medium dutyconcealed/ surface PVC conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including continuous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of the following.(Note: Colour code shall be maintained as per IE rule) |
| 19 | (a) One tube light/Bulb/ security light/ bell point controlled by one, one way switch 05 / 06 Amps. |
| 20 | (b) OneExhaust fanpoint controlled by one, one way switch 05 / 06 Amps. |
| 21 | (c) One three pin 5 Amp socket on same board with other switches. |
| 22 | (d) One three pin 5 Amp socket on independent board |
| 23 | . All as per item No-18 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity conductor of size 2.5 Sq mm. |
| 24 | Supply and fixing Switch piano; flush type, single pole, one way, and 5/6 Amps complete all as specified. |
| 25 | Supply and fixing Switch piano; flush type, single pole, one way, and 15/16 Amps IS: 3854 marked with valid CML No. complete all as specified. |
| 26 | Supply and fixing Socket outlet multipurpose having provision for 3 pin, 6 Amp and 2 pin,6 Amp, piano flush type complete all as specified. |
| 27 | Supply and fixing Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, piano flush type complete all as specified. |
| 28 | Supply and fixing ceiling rose, three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified |
| 29 | Supply & fixingLED light fitting 1x20 watt, 220 volt AC decorative box type withdriver, holders, including LED tube light connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and directed. |
| 30 | S&FDB SPN, 240 voltwith 200 ampsrated copperbus bar for double door 8 way IP-43, IK-09 suitable for one MCB SPN as incoming andMCB SP as out going,mounting flush on wall and making good disturbed surfaces complete all as specified and directed. (MCBs shall be measured and paid separately). |
| 31 | S&F MCB SP, 5 to 32 Amps,240 Volt 10 KA\"C\" curve conforming to ISI marked complete all as specified & directed . |
| 32 | S&F MCB SPN, 40 to 63 Amps,240 Volt 10 KA\"C\" curve conforming to ISI marked complete all as specified & directed . |
| 33 | Supply and fixing BLDC Ceiling fan complete with blades, down rods, electronic fan regulator and accessories 230 Volts, 1200 mm sweep,min air delivery 210 CFM with service value 6.00 BEE,28Wfive star rated with brushless direct currentmotor with squirrel cage induction motor complete all as specified and directed. |
| 34 | Supply and fix exhaust fan metal body AC single phase 230 V of size 450 mm sweep heavy duty with blades and frame and louvers complete all as specified and directed. |
| 35 | Supply, fix, connecting and testing building LED security light fitting 35 W with pressuredie cast aluminium housing, heat resistant toughened glass, IP 66 protection and impact resistance of IK 07 with 10KV Built-in Surge Protection Device, better optics for uniform distribution compete with electronic driver, including connecting up with three core copper conductor cable with 1.5 sqmm size copper wire from ceiling rose to connector of light fitting including GI Bracket 32mm,0.75m long bend to shape with clamp complete all as specified and directed. |
| 36 | M&Lforearthing complete with G .l earth plate electrode 60 cm x 60 cm x 6 mm thick burrieddirectlyinground( earth pit notless than 2.25 m deep below GL ) with top edge of the plate not less than 1.5 mbelow the normal groundlevelconnectedgalvanized earth lead wire 4.0 mm bymeansofbolts, nuts, check nuts and washers of galvanised ironorsteelincluding necessaryexcavation& earth work in any type of soil, removing surplus soil to a distance not exc 50mtr,including PCC chamber in PCC (1 : 2 : 4), type B1, using (20 mm graded stone aggregate), mild steel frame madeout of angle iron of size 40 mm x 40 mm x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick Cl coverwith handle , watering arrangement with funnel internally secured with wire mesh with 20 mm dia lightgrade GI pipe for watering, 15 mm dia mediumgrade Gl pipe for earth wire protection with and including alternate layer of charcoal dust and common salt. complete all as shown in electrical plate No 3connectedto DBs all as specified and indicatedincluding testingon completion. |
| 37 | Sch \"A\" Part IV (Water Supply) |
| 38 | Chemical dosing system one each for Alum consisting of metering dosing pump of capacity 14 LPH against 5 Kg/cm2 pressure with FHP electric motor operating on 415V/3ph power supply with chemical preparation cum dosing tank of capacity 200 Liters- one no.made out of FRP duly mounted with agitator made of SS-316 and having suitable arrangement for mounting Dosing pump on the tank lid.Make: Chloromax/ Aquamech/ Aduafab/ ION Exchange |
| 39 | Oxidation Chamber suitable for 10000GPH capacity , factory fabricated out of Mild Steel sheets having dished ends and size not less for 3.5 Kg/cm2 pressure. Vessel thickness for dished ends to be 8mm and for shell to be 8mmwith header & lateral sytem for distribution of water & ai .Oxidation chamber would be complete with frontal piping and butterfly valves for inlet , outlet , drain , air feeding , automatic air release arrangement. Also the vessel to be provided with suitable manhloe and hand hole with proper bolted covers for ease of maintenance . Fresh charge of Iron removal media upto a min. bed depth of 1250mm to be provided in the oxidation chamber. All internal surfaces to be painted with lead free black bitumastic paint and external surfaces to be painted with two coats of synthetic enamel over a coat of red oxide primer.Make: Chloromax/ Aquamech/ Aduafab/ ION Exchange. |
| 40 | Air compressor suitable to deliver oil free air @10 cu.m/hr against 3.0 kg./cm2pressure complete with electric motor and accessories including air filter , pressure gaugeand outlet control valve etc.. ( 1W+1SB) Make: Elgi/Indoair/BAC |
| 41 | Iron removal Pressure Filter suitable for 10000GPH capacity , factory fabricated out of Mild Steel sheets having dished ends and size not less than 1800mm dia. And 1800mm HOS suitable for 3.5 Kg/cm2 pressure. Vessel thickness for dished ends to be 10mm and forshell to be 8mm with under bed disribution header with laterals. Filter vessel would be complete with frontal piping and butterfly valves for inlet , outlet , drain , backwash , air scouring, air release arrangement. Also the vessel to be provided with suitable man hole and hand hole with proper bolted covers for ease of with proper bolted covers for ease of maintenance . Fresh charge of Filter media consisting of graded gravels and quartz sand upto a min. bed depth of 1100mm to be provided in the filter . All internal surfaces to be painted with lead free black bitumastic paint and external surfaces to be painted with two coats of synthetic enamel over a coat of red oxide primer.Make: Chloromax/ Aquamech/ Aduafab/ ION Exchange. |
| 42 | Air blower suitable to deliver back wash air @140 cu.m/hr against 0.35 kg./sqcm pressure complete with electric motor, air filter , silencer ,wafer check valve and common base frameetc.Make: Everest/Airvac/ION Exchange |
| 43 | Supply and Install Pumping sets,Discharge-756 LPM & Head 30 mtr centrifugal, electric driven 10 HP Motor Complete including suitable size of Copper cable LT panel Startor to Motor. all as specified and directed.Note: Rate quoted to be deemed inclusive of PCC foundation. Nut and bolts & suitable copper cable from starter to motor\"Note: Rate quoted shall deemed to be inclusive of PCC foundation, nut and bolts & suitable size of PVC insulated copper cable from starter to motor.Make: KSB/Kirloskar/Crompton Greaves |
| 44 | Supply and Install Pumping sets,Discharge-756 LPM & Head 10 mtr centrifugal, electric driven 5 HP Motor Complete including suitable size of Copper cable LT panel Startor to Motor. all as specified and directed.Make: KSB/Kirloskar/Crompton Greaves |
| 45 | Supply, install, testing and commissioning of Mild steel chlorine gas cylinder suitable for 100Kg capacity with filling lequid chlorine gas, industrial type as manufacturer recommended pressure for usage of drinking water treatment for improving taste, safety and odour of drinking water, highly reactive, reliable, optimum quality to kill Bacterial organisms at public properties, complete all as specified and as directed. Note: Rate quoted to be deemed inclusive of PCC foundation. Nut and bolts & suitable copper cable from starter to motor\" Note: Rate quoted shall deemed to be inclusive of PCC foundation, nut and bolts & suitable size of PVC insulated copper cable from starter to motor. |
| 46 | Supply, install, testing and commissioning of Remote wall/floor panel mounted Vacuum Chlorinator (regulator) for reduces the gas from a varying supply pressure 10kg- 75kg capacity with suitable capacity pressure feed pump including safety kit complete set suitable for disinfection of water through Vaccum feed or Pressure feed (Motor) chlorination by main water supply/swimming pools/sewage water treatment etc, complete all as specified and directed. Make: Chloromax/ Aquamech/ Aduafab/ ION Exchnage. |
| 47 | Notes :-The fwg itemswill not be measured as part of plant and shall be measured and paid separately:(a) All interconnecting pipe as per site.(b) All civil works including foundation.(c) All electrical works including starter panel, cabling and earthing. |
| 48 | Supply and testing for Iron Test Kit (0-10 mg/l, Blue, Aqua) Determines the dissolved Iron concentration in water by conversion of the Iron present in it to ferrous (Fe2+) state. Make process of testing fast, easy and safe, to match the color chart, make it simple to obtain the iron level in water, complete all as specified and as directed. |
| 49 | Supply, laying, jointing and lekage testing of MS ERW Pipe for making inter connection between motors and IRP Plants including supply and fixing of all fittings such as bend, tee, elbow, union, reducer etc laid in surfaces/trenches complete all as specified and directed of the following size:-(a) 50mm dia |
| 50 | (b) 65 mm dia |
| 51 | (c) 80 mm dia |
| 52 | (d) 100 mm dia |
| 53 | Supply and laying of 150 mm (6\") bore centrifugally cast (Spun) Ductile Iron pressure pipe with spigot & socket end, class K-9 in any length laid in trenches, conforming to IS-8329/2000 with cement mortar lining with and including rubber gasket jointing conforming to IS-15382/tyton joint complete with all fittings e.g Tee, Bends etc all as specified and directed. |
| 54 | M&L for run leadjoint Spigot and socketed pipes and fittings for 150 mm bore of pipe completeall as specified. |
| 55 | Supply and fix CI non returnvalve of size 150 mm bore, ISI marked including all joints with rubber or fiber board, bolts and nuts, washers etc complete all as specified. |
| 56 | S & F for Gun Metal Air Release valves, heavy duty screwed ends ISI marked suitable for 25 mm (1”) bore pipe and fixing up in oxydation chambers & IRP Pressure filter chambers including jointing materials etc, including making arrangement for safe working complete all as specified and directed. |
| 57 | Supply and fix CI Foot Valve conforming to IS 4038 100 mm (4”) dia including jointing materials etc, including making arrangement for safe working complete all as specified and directed. |
| 58 | Supply and fix Stainer Y Type confirming to IS, Size 100 mm (4”) diaincluding jointing materials etc, including making arrangement for safe working complete all as specified and directed. |
| 59 | Supply and fix pressure gauge 4\"dial 0-21 kgs rating complete all as specified. |
| 60 | M & L for Cutting CI /DI pipes and reducing to required length ,insertion of new tees, elbow branches before laying pipes. |
| 61 | S&F and testing of cast iron/DI pipe fittings (specials) heavy duty for spigot and socketed pipes upto 200mm bore of any type such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \"Y\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed. |
| 62 | Supply and laying GI Pipe 80 mm dia Light gade with all fittings laid in road cutting for cable protection for pipe required for supporting the light fittings, complete all as specified and directed by the Engr-in-Charge. |
| 63 | Excavation in trenches not exceeding 1.5m and not exceeding 1.5m in depth for laying of electric cable and getting out in hard and dense soil, complete all as specified and directed by the Engr-in-Charge. |
| 64 | M&L for boring the holes under road pavements, hardstanding by trenches less technology, using ultrasound technique and necessary machine including DI/CI/GI/HDPE/PP-R Pipe of 25mm to 150mm bore suitable for 0.4 mpa working pressure complete all as specified and directed. |
| 65 | Returning, filling in excavated soil, including leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed by the Engr-in-Charge. |
| 66 | Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above gthe starting point complete all as specified and directed by the Engr-in-Charge |
| 67 | Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed by the Engr-in-Charge. |
| 68 | M&L for sand cushioning with ayer of sand 8cm thick before laying of cable and 15cm after laying, streching & testing of cable in trenches complete all as specified and directed by Engr-in-Charge. Note: Only punned thickness i.e 18cm shall be measured and paid complete all as specified and directed by the Engr-in-Charge. |
| 69 | S&F sluice valve class PN 1.6 heavy duty flanged ends drilled ISI marked confirming to IS: 14846, wheel operated (Handle with high tensile stainless steel spindle, including nuts, bolts and jointing with jointing materials etc. complete all as specified and directed for the 150 mm bore sizes. |