Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling plain or corrugatedsteel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings including scafoldings of any height, complete all as specified and directed. |
| 2 | Supply & fix Pre-painted galvalume aluminium zinc coating GI based trapezoidal/mangalore tile profile roofing sheets, chajjas,0.50 mm thick of any colour/length having tensile strength of 550 MPA as in roof coverings having effective & overall width 1015 mm &1072 mm respectively, profile hieght 28.5 mm and centre to centre distance between ribs 203 mm fixed with self tapping screws as directed by manufactureron wooden/steel membersincluding scafoldings of any height of the bldg, complete all as specified and directed. |
| 3 | Supply & fix Pre-painted galvalume aluminium zinc coating GI based plain sheet profile roofing sheets, chajjas,0.50 mm thick of any colour/length having tensile strength of 550 MPA as in roof coverings fixed with self tapping screws as directed by manufactureron wooden/steel membersincluding scafoldings of any height of the bldg, complete all as specified and directed. |
| 4 | M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application, complete all as specified and directed. |
| 5 | M&L Priming surfaces and applying normal treatment (formoderate conditions) using glass fibre base bitumen felt, grade 2, complete all as specified and directed. |
| 6 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 7 | S&F forRolled mild steel in joist, channel, angle or tee sections or MS Flats fixed independantly without connecting plates, etc Fe 410-W (Gde-E- 250) quality- A (cut to ordinary lengths i.e within 20mm of lengthindicated) as in frame work for Galvalume / CGI chajjas, complete all as specified and directed. |
| 8 | Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the primises, complete all as specified and directed. |
| 9 | M&L Light shade vitrified coloured Ceramic tiles 8-9 mm thick (Square/rectangular) polished area of each tile not exceeding 0.36 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed. |
| 10 | M&L Glazed tiles digital coloured ceramic tiles 300x450x7mm/300x600x7mm thick in vertical surfaces such as skirting and dados set and jointed in neat cement slurry pointed in coloured cement to match, complete all as specified and directed. Note:- Rate of designer border (Highlighter) tiles are included in this item. |
| 11 | M&L Non Skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed. |
| 12 | M&L Screed bed or bedding layer of mortar 15 mm thick in (1:4)for laying floor finishes like tiles etc, complete all as specified and directed. |
| 13 | M&L rendering 10 mm thick on fair faces of brick work in CM (1:4), complete all as specified and directed. |
| 14 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons,dados etc laid, bedded and pointed in any mortar and removal of rubbish off the site, complete all as specified and directed. |
| 15 | M&L for machine cutkota stone slab flooring 20-25mm thick over cement screedbase laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed. |
| 16 | M&L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with cement, complete all as specified and directed. |
| 17 | M & L for machine cut, polished cudappah stone work 20 to 25 mm thick (table rubbed and polished) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing as in kitchen platform, flooringand all other similar works, including laying over 15mm thick cement mortar (1:4), complete all as specified and directed. |
| 18 | M&L for granite (of any approved colour) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including 15mm thick screed bed including grindingand polishing as in kitchen platform, counter for WHB, flooring and all other similar works, complete all as specified and directed. |
| 19 | Taking up or down steel tubing and connection including cleaning for refixing or removed to store,15 mm dia bore, complete all as specified and directed. |
| 20 | Taking up or down steel tubing and connection including cleaning for refixing or removed to store,20 mm dia bore, complete all as specified and directed. |
| 21 | S/F GI tubing 15mm bore medium grade medium grde with all fittings and fixed complete to wall and ceilingor laid in floors, complete all as specified and directed. |
| 22 | S/F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors, complete all as specified and directed. |
| 23 | Cutting chases, pinning in making good to facing on brick walls where required and pointing in cement mortar (1:3) to ends for concealed water tubing and making good ,cutting n, exc. 10cm girth, complete all as specified and directed. |
| 24 | Demolition and breaking up drain pipesof dia 100 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and directed. |
| 25 | Demolition and breaking up drain pipes of dia 75 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and directed. |
| 26 | Demolition and breaking up drain pipes of dia 40 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and directed. |
| 27 | S&F PVC (SWR) pipes, 110 mm external dia double socketed in any length with rubber joints, fixed to walls withPVC brackets/clips, complete all as specified and directed. |
| 28 | S&F PVC (SWR) pipes, 75 mm external dia double socketed in any length with rubber joints, fixed to walls withPVC brackets/clips, complete all as specified and directed. |
| 29 | S&F PVC (SWR) pipes, 40 mm external dia double socketed in any length with rubber joints, fixed to walls withPVC brackets/clips, complete all as specified and directed. |
| 30 | S&Fin repairs 75mm dia PVC (SWR) bends, complete all as specified and directed. |
| 31 | S&Fin repairs 110 mm dia PVC (SWR) bends, complete all as specified and directed. |
| 32 | S&F in repair 40mm dia PVC (SWR) bends, complete all as specified and directed. |
| 33 | S&F in repairs 110mm dia PVC (SWR) vent cowl, complete all as specified and directed. |
| 34 | S&F in repair vitreous China wash down water closet pan (pedestal pattern) white, including trap, connection to drain and flushing pipe including seat cover for pedstal pan, complete all as specified and directed. |
| 35 | S&F in repair vitreous China wash basin white, flat back,size 580X450 mm including cutting for pinning in ends of brackets, complete all as specified and directed. |
| 36 | S&F in repairs 10 litre capacity PVC low level flushing cisternwith all accessories complete fixed with WC including syphone pipe, PVC flushing pipe of size, complete all as specified and directed. |
| 37 | S&F as in repair 15 mm bore fancy type angular valve cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed. |
| 38 | S&F in repair PVC connection 15 mm size with PTMT nuts of length 600 mm of approved quality suitable for hot and cold supply, complete all as specified and directed. |
| 39 | S&F as in repair 15 mm bore fancy type concealed stop cock (regular body) cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed. |
| 40 | S&F as in repair 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed screwed both ends for iron pipe or for unions, complete all as specified and directed. |
| 41 | S&F as in repair 15 mm bore fancy type bib taps long body cast copper alloy 15mm bore with fancy chromium plated screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed. |
| 42 | S&F as in repair 15 mm bore fancy type 2-in-1 bib taps long bodycast copper alloy 15mm bore with fancy chromium plated screwed down, screwed for iron pipe or for brass ferrule. with wall flange, complete all as specified and directed. |
| 43 | S & F in repair 15 mm bore, brass chromium plated, fancy type health faucet with SS connection pipe 1 mtr long, complete all as specified and directed. |
| 44 | S & F in repairs CP Towel Bracket (61 cm) long, complete all as specified and directed. |
| 45 | S&F sheet glass corner shelf assembly consisting of 5.50 mm thick sheet galss shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long, complete all as specified and directed. |
| 46 | Supply and fixing 15 mm bore overhead shower of size 200mm (square of circular) single flow (ABS body chrome plated with grey face plate) with rubit cleaning system including shower arm 200 mm long(stainless steel) square shape with wall flange, complete all as specified and directed. |
| 47 | S&F in repair 15 mm bore piller taps cast copper alloy with capstan heads, chromium plated, screwed down, fancy type high pressure, with or without lettred \"HOT or COLD\" with long screwed sunk and fly nuts, complete all as specified and directed. |
| 48 | S&F for mirror cabinet PTMT of 400mm x 500 mmwith magnetic looking arrangements fixed with and inclduling chromiplated brass screws and PVC rawl plugs, complete all as specified and directed. |
| 49 | S&F in repairs urinals half stall, flat back of size 355x340x535mm in snow white including each and all acessories, complete all as specified and directed.Make: Jaguar (Item code-URS-WHT-13261. HSN code-69109000) / Kerovit / Parko |
| 50 | S&F in repairs auto closing flushing valve for flat back urinals, complete all as specified and directed. Make:- Jaguar. (Item code-PRS-CHR-077. HSN code-84818020) / Kerovit / Parko |
| 51 | M&L in repair 75 mm dia PVC (SWR) floor trap with grating including jointing with solvent cement, complete all as specified and directed. |
| 52 | M&L in repair 110mm dia PVC (SWR) gully trap with including jointing with solvent cement, complete all as specified and directed. |
| 53 | Demolition of cement concrete in ground floor & paving n. exc 15 cm thick (belowor above GL) unreinforced, complete all as specified and directed. |
| 54 | Material and labour for PCC 1:4:8, type B-2 (using 40 mm graded stone aggregate) as in foundation filling, mass concrete and sunken floor treatments, complete all as specified and directed. |
| 55 | M&L for PCC 75 mm thick type C-1 (1:3:6) (20 mm graded stone aggregate) laid in alternative as in plinth protection including finished the surface even & fair without using extra cement & filling the joints with mastic filling i.e one part of bitumen 85/25 & 3 part of sand by weight, complete all as specified and directed. |
| 56 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demoletionof any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 57 | M&L reinforced cement concrete type B-0 (12.50mm graded crushed stone aggregate) for slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. |
| 58 | Use and waste flat Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed. |
| 59 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 60 | Supply & Fixing in repair vitreous China squatting pan, \" Orissa pattern, size 580 x 440 mm white, with integral footrests (excluding flushing cisteren and flush pipe) including taking down existing squating pan, complete all as specified and directed. Make : Cat Part No S3010104 of Cera or Equivalent in Hindware / Parryware. |
| 61 | Materials and labour for complete removal of existing treatment and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 1mm thick (average) Birla wall putty, complete all as specified and directed. |
| 62 | Demolition of ceiling boards of any description, and any thickness including cover fillets and frame work, complete all as specified and directed. |
| 63 | M & L for Powder coated aluminium snap grid having a size of605mm x 605mm and sections incorporated in frame work shall conform to IS 733, IS 737 and IS 1285 and snap grid frame work shall be fixed to ceiling with supporting hanger 6mm dia mild steel rod, J bolts with necessary bolts, nuts and washers all as per manufacturer\"s instruction. The main & cross tees shall be jointed at junction/crossings with anodized aluminum angle bracket of size 19.05mm x 19.05mm x 1.45mm, weighing 0.14 Kg per RM, fixed with suitable mild steel, bolts nuts and washer all as per manufacturer\"s instruction, the snap grid shall be supported at ends all along the wall with anodized aluminum angle of size38mm x 25mm x 2.18mm, weighing 0.358 Kg per running meter, complete all as specified and directed. |
| 64 | S & F of 8-9mm thick PVC laminated gypsum ceiling tiles size of 600mm x 600mm, square edge, front side laminated PVCand back side aluminium foil, complete all as specified and directed. |
| 65 | Demolition of brick work or stone /boulder masonrybuilt in cement mortar, including all quoins, arches, pillars, etc, complete all as specified and directed. |
| 66 | M & L for brick work with sub class \"B\" bricks straight or curved on plan exc 6 m mean radius and built in CM (1:6), complete all as specified and directed. |
| 67 | Taking downcement plaster ofany description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water etc including all necessary scaffolding arrangments of any height, complete all as specified and directed. |
| 68 | M & L for Ready mix plaster for external wall rendering 12-14 mm thick in two coats of 10 mm base coat and 5 mm finishing coat on brick wall or concrete surfaces and making groove of appropriate size and finishing sand faced finished using sponge, including use of scaffolding, complete all as specified and directed.Name of Manufacturer: M/s Ultratech Cement Ltd / M/s Accoplast / M/s CK Birla AEROCON |
| 69 | Supply only liquid water proofing compound, complete all as specified and directed. |
| 70 | M & L for Ready mix plaster for internal wall rendering 10-12 mm thick in two coats of 10 mm base coat and 5 mm finishing coat on brick wall or concrete surfaces and making groove of appropriate size and finishing sand faced finished using sponge, including use of scaffolding, complete all as specified and directed. Name of Manufacturer: M/s Ultratech Cement Ltd / M/s Accoplast / M/s CK Birla AEROCON |
| 71 | M&L for plastering 15-20 mm thick average Polymer modified mortar (ready mix pack) in two coat 15 mm base coat and 5 mm finishing coat with and including curing as per manufacturer\"s instruction, complete all as specified and directed.Make : Dr. Fixit Repair Pro Polymer Mortar, Fosroc RENDEROC S2 structural grade polymer mortar, ShaliFix FRM Polymer Modified Fiber Reinforced Mortar of STP or equivalent as approved by GE |
| 72 | M&L for preparing New surfaces of walls/ceilings and applying two coat of weather proof acrylic exterior paint (100% Acrylic) of Apex Ultima,over a coat ofprimer and scaffolding where required at any hieght for external painting, complete all as specified and directed. |
| 73 | M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primingpaint over 1mm thick (average) wall putty all as specified. |
| 74 | M&L for the prepration of wall including Complete removal of existing treatment and applying2mm thick (average) wall careputty, rubbing with sand paper for making the wall surface to receivetwo coats of distemper oil emulsion over a coat of alkali resistant priming paint, complete all as specified and directed. |
| 75 | M&L for preparing old surfaces of walls/ceilings and applying two coat of weather proof acrylic exterior paint (100% Acrylic) of Apex Ultima,over a coat ofprimer and scaffolding where required at any hieght for external painting, complete all as specified and directed. |
| 76 | M&L for preparation of new or previously untreated surfaces and applying two coats of synthetic enamel paint over a coat of primer red oxide, zinc chrome, complete all as specified and directed. |
| 77 | M&L for cleaning all loose laitance on the wall and concrete substrate and applying one coat of epoxy bonding agent of SBR latex on exposed concrete surface to ensure bond between old concrete & new concrete by brush application including scafolding at any height of bldg, complete all as specified and directed.Make: Shalicrete URP of STP Ltd or Nerolac perma SBR latex. |
| 78 | S&F in repairs Rotational moulded polyethylene water storage tanks 500 litres (cylindrical vertical with closed top) hoisted and fixed in position including all fittings all as per existing requirements, complete all as specified and directed. |
| 79 | S&F in repairs Rotational moulded polyethylene water storage tanks 1000 litres (cylindrical vertical with closed top) hoisted and fixed in position including all fittings all as per existing requirements, complete all as specified and directed. |
| 80 | Taking down Chowkhats or frames (without taking of shutters from frames) n exc 1.50 sqmeach, complete all as specified and directed. |
| 81 | Supply and fix solid PVC door frame of size 50mm x 47mm made out of 5mm single piece extruded PVC profiles reinforced with 19 x 19mm MS square tube provided with EPDM rubber gasket weather seal through out the frame and the profile mitre cut at two corners and joined by inserting 2 nos 150mm long brackets of 15 x 15mm MS square tube inside 19 x 19mm MS square tube suitably screwed, complete all as specified and directed. |
| 82 | Supply & fixfactory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes of size 15 x 15mm for top andbottom rails and 19 x 19mm for stiles, MS frame covered with 5mm thick single piece extruded PVC profile \"C\" channel having a 5mm thick PVC sheet strip of 20mm width struck inside with solvent cement, forming stiles, and 5mm thick single piece extruded PVC profile for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail; panelling of 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with PVC sheet beading, and joined together with solvent cement adhesive etc all as per manufacturer\"s instructions and drawings as shown in SSR Part-I 2009, complete all as specified and directed. |
| 83 | S&F 100 mm butt hinges medium weight cold rolled mild steel, complete all as specified and directed. |
| 84 | S&F aluminium anodised 200 mm barrel tower bolts of extruded section, complete all as specified and directed. |
| 85 | S&F in repair aluminium handle 150 mm cast type anodised, complete all as specified and directed. |
| 86 | S&F Powder coated aluminium frame of any colour (minimum thickness of powder coating 50 micron)for doors/windows/ ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and directed. |
| 87 | M&L for 5.50 mm thick sheet glass, ordinary quality and glazing with aluminium beads and rubber gaskitin square exc 0.5 sqm in each pane frosted on one side, complete all as specified and directed. |
| 88 | M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors, complete all as specified and directed. |
| 89 | M&L Screed bed or bedding layer of mortar 15 mm thick of CM 1:6 for laying floor finishes, complete all as specified and directed. |
| 90 | M&L Mild steel work for Framed work such as grills, gratings, etc. with ends of barsshouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed. |
| 91 | Material and labour for crushed sand filling under precast interlocking paver blocks and all other similar works, complete all as specified and directed. |
| 92 | M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment, complete all as specified and directed. |
| 93 | M&L for 100mm thick cement concrete type C-2, 1:3:6, 40 mm graded aggregate) in sub base, complete all as specified and directed. |
| 94 | Cutting into existing manhole for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC1:2:4 type B1, smooth finished and reforming benching as required for internal pipe of dia 150 mm, complete all as specified and directed. |
| 95 | Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m in deep for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil, complete all as specified and directed by Engineer-in-Charge. |
| 96 | Returning, filling including spreading leveling watering and well ramming in layers n. exc 25 cm in any type of soil, complete all as specified and directed. |
| 97 | Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point, complete all as specified and directed. |
| 98 | Demolition and breaking up drain pipes of diameter 200 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and directed. |
| 99 | S & F Reinforced concrete pipes, class NP3, 200 mm dialaid and jointed, complete all as specified and directed. |
| 100 | M & L PCC in 1:3:6 type C-2, 200mm dia using 40 mm graded aggregate Concrete bed to drain pipes including packing under and for hauching & Benchingagainst the sides of pipes after they are laid and tested, complete all as specified and directed. (Note :- (i) Thickness of bed below the barrel of pipes:15cm for pipes 200mm dia and over.(ii) Width of bed: Outer diameter of drain pipes (not of sockets/collars) plus 30 cm(iii) The rates include for any necessary shuttering and supports to concrete and for laying beds to falls. |
| 101 | S&F in repair precast reinforced cement concrete manhole covers of size 1000mm x 500mm, 100-125mm thick, including coping, complete all as specified and directed. |
| 102 | Excavating over areas, n exc 1.5 m deep and getting out any type of soil, complete all as specified and directed by Engineer-in-Charge. |
| 103 | Excavating over areas, exc 1.5 m deep and n.exc 3m getting out any type of soil, complete all as specified and directed by Engineer-in-Charge. |
| 104 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm in disintegrated rock, complete all as specified and directed by Engineer-in-Charge. |
| 105 | Removing surplus excavated material disintegrated rocks to exc 250 mtrs and n.exc 500 mtrs and depositing where directed at a level not exceeding 1..50 mtrs above the starting point, complete all as specified and directed by Engineer-in-Charge. |
| 106 | M/L Plain Cement concrete (1:3:6) type C-1 with 20 m graded stone aggregate in surface channel and drain, complete all as specified and directed by Engineer-in-Charge. |
| 107 | M & L for Cement concrete (1:2:4) type B-0 with 12.50 mm graded stone aggregate as in coping, complete all as specified and directed by Engineer-in-Charge. |
| 108 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, complete all as specified and directed. |
| 109 | M&L for Formwork tofaces (curved surface) of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter; curved and fair finished surfaces, complete all as specified and directed. |
| 110 | M & L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed. |
| 111 | Mild steel bars 6mm to 8mmdia, cut to length, bent to shape required, including cranking, bendingspirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confirming to Fe410 -S or Fe 410-O, complete all as specified and directed. |
| 112 | M&L for RCC M-30 as foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 113 | M&L for RCC M-30 walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresse, complete all as specified and directed. |
| 114 | Supply only integral water proofing compound, complete all as specified and directed. |
| 115 | M&L Rendering 10 mm thick on concrete surfaces in cement mortar 1:4 and finished even and smooth withou using extra cement, complete all as specified and directed. |
| 116 | M&L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled in layers 75mm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 117 | S&F Rolled mild steel for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., complete all as specified and directed. |
| 118 | M&L Rolled mild sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates,Fe 410-W (Gde E-250) quality A, complete all as specified and directed. |
| 119 | Preparation of New or old previously untreated surfaces including two coat of synthetic enamel (ordinary tint) paint over priming with red oxide, zinc of any description, over 10cm in width or girth, not otherwise described, complete all as specified and directed. |
| 120 | M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 300mm bore pipe, complete all as specified and directed by Engineer-in-charge. |
| 121 | M&L for 300mm bore reinforced concrete pipes, class NP3 (ISI marked) with collars, laid in trenches and jointed, complete all as specified and directed by Engineer-in-charge. |
| 122 | M&L for precast cement concrete solid block masonry exc 10cm in width and setting in CM 1:6 type C-1, 1:3:6, complete all as specified and directed. |
| 123 | M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and directed. |
| 124 | M&L Rendering 15mm thick in 1:4 cement plaster on of stone masonary surface other than fair faces is to be finished even and smooth (without using extra cement), complete all as specified and directed. |
| 125 | M&L for applying two coats of cement base paint over a coat of primer after preparation of newly plastered surfaces, complete all as specified and directed. |
| 126 | S & F for rotational moulded polythene water storage tank (cylindrical vertical with closed top, white colour) hoisted and fixed in position all as specified in SSR part I capacity of tank 2000 ltrs, complete all as specified and directed. |
| 127 | S & F 20mm Ball brass valves, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed. |
| 128 | S&F Gun metal globe or gate valves with iron wheel head screwed both end for iron pipe and fixed to 20 mm bore pipe, complete all as specified and directed. |
| 129 | S&F 300mm in bore reinforced concrete pipes, class NP2 with one collar per length of pipe, complete all as specified and directed. |
| 130 | S&F for 4mm dia galvanised steel wire, 150x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling, complete all as specified and directed. |
| 131 | S&F 100mm bore (sand cast pipe) soil, waste and vent pipesin any length with or without ears and jointing with cement & fixed to walls with MS clamp, complete all as specified and directed by Engineer-in-charge. |
| 132 | S & F 100 mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured), complete all as specified and directed. |
| 133 | S&F 150mm UPVC Pipes (SCH-40) including socketed in any length with rubber ring joints & fixed to walls/floors with MS clamp, complete all as specified and directed by Engineer-in-charge. |
| 134 | S&F 150 mm dia PVC (SWR) bends with access doors any radius, complete all as specified and directed. |
| 135 | S&F 50mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints & fixed to walls/floors with MS clamp, complete all as specified and directed by Engineer-in-charge. |
| 136 | S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes andfixed to walls, complete all as specified and directed. (Note : upto any height and including necessary scafolding) |
| 137 | S&F 110 mm dia PVC (SWR) bends with access doors any radius, complete all as specified and directed. |
| 138 | Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling, complete all as specified and directed. |
| 139 | Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceilingand incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable modular or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washersand making goodthe disturbed surfaces as per existingfor one light point controlled by one switch. Note :- Switch, socket and fan regulators to be measured and paid for separately . PVC Conduit confirming to IS 9537 part I & III Note (All chases will be cut by chase cutter only). |
| 140 | Description all as per Srl item No.139 here in before but for socket outlet point 5 Amp on same board. |
| 141 | Description all as per Srl item No.139 here in before but for socket outlet point 5 Amp on Independent board. |
| 142 | Description all as per serial item No 139 above but with 4 sqmm cablefor 3 pin 15 Amps switch socket outlet (Power point). |
| 143 | Supply and fixing modular switch 1 way 6A module 230/250 volt , AC supply,ISI Marked, with white cover plate with frame, complete all as specified and directed. |
| 144 | Supply and fixing modular switch 2 way 6 A module 230/250 volt , AC supply, ISI Marked, with white cover plate with frame, complete all as specified and directed. |
| 145 | Supply and fixing modular switch 1 way 16 A module 230/250 volt, AC supply, ISI Marked, with white cover plate with frame, complete all as specified and directed. |
| 146 | Supply and fixing modular sockets 6A 2/3 pin combined 2 module 230/250 Volts, 50 Hz, AC supply, ISI Marked, with cover plate, complete all as specified and directed. |
| 147 | Supply and fixing modular sockets 6A/16A 2/3 pin combined 2 module 230/250 Volts, 50 Hz, AC supply, ISI Marked, with white cover plate with frame, complete all as specified and directed. |
| 148 | Supply and fixing in repair ceiling rose surface bakelite 65x50mm, 3 terminal, complete all as specified and directed. |
| 149 | Supply and fixing in repair, LED lights fitting 1x 20W, 220V, AC decorative box type, warm white / white type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete pre wired fixed to wallwith 2 nos PVC block of suitable size, complete all as specified and directed. |
| 150 | S & F in repair Wall bracket decorative light down lighter Squre / round fitting warm white /Cool white / white type with lamp 18 Watt complete with necessary connection, complete all as specified and directed. |
| 151 | S&F Exhaust fan 230 volts, 250mm, plastic body includingmaking all electric connection complete all as specified and as directed including cutting of hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall, complete all as specified and directed. Note:- Old fan deposited to MES store. |
| 152 | Supply and fix MCB Distribution board, 240 volts single pole andneutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking down, complete all as specified and directed. |
| 153 | Supply and fix MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity \"C\" series, complete all as specified and directed including taking down old one. |
| 154 | Supply and fix in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB\"s, complete all as specified and directed. |
| 155 | Supply and fix in repairs MCCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified. (Note:-MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule.Note:-Copper thimble shall be used for connection of cable. |
| 156 | Supply and fix MCCB TPN, 240 Volts, 63to 100Amps, 10 kA rupturing capacity415 Volts, complete all as specified and directed including taking down old one. |
| 157 | Supply and fixing of hot water Geysers of 25 ltrs capacity 5 star rated vertical type includng fixing of bolts, nuts grouted into the wall, and necessary cement work, making good of disturbed surface of wall, giving electric, hot and cold water pipe, tab etc and water connection and testing after installation, complete all as specified and directed. Note:- Old geyser deposited to MES store. |
| 158 | Supply & laying galvanized steel tubing, medium grade laid in trenches/floor/wall and joined including necessary fittings such as bends, elbow, tees, sockets, etc for 15mm dia pipe, complete all as specified and directed. |
| 159 | Material & Labour for Sub main wiring with two run of 6 sqmm stranded copper conductor PVC unseathed FRLSH wire along with 6 sqmm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduite of adequate size (not less than 32 mm dia) for housing the wires for from Pannel / Main DB to house SPN DB including taking down old Unsv submain with all associated fixtures, complete all as specified & as directed by engr-in-charge. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note:- Mode of measurement two runs of 6 sqmm cable and one run of 6 sqmm cable with PVC conduite shall be measured as one length. |
| 160 | M & L Sub main wiring with two run single core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia Cassing cappingISI markedwith all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc, complete all as directed. Note: (i) Two runs of 4 sqmm and one run of4 sqmm cable and one run of PVC conduitshall be measured as one RM. |
| 161 | M & L Sub main wiring with two run single core 1.50 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20mm dia Casssing cappiingISI markedwith all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 1.50 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc, complete all as directed. Note: (i) Two runs of 1.50 sqmm and one run of1.50 sqmm cable and one run of PVC conduitshall be measured as one RM. |
| 162 | Material and labour and replacement for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways andone handle for lifting made out of 8 mm dia TMTbar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I. |
| 163 | M & L for repair galvanised iron strip 25x3mm earth continuity conductor or main earthing lead fixed to wall on batten or recess or chasesoror buried in ground or drawn in conduit/pipe or fixed to poles in roof ofhigh rise bldg and as required by sadles not more than distatance of 50 cm between two saddles with jointing nuts, bolts /washers to wall/surface or recess of high rised buildings or burried in ground or any situation for loop, complete all as specified and directed by the Engineer-in-Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail