| 1 | Wiring for surface/Concealed Light/Fan/Exhaust fan point with 2 x 1.5 Sq.mm PVC insulated FRLS wires copper conductorPolycab/Finolex/RPG make 1100Volts grade in PVC conduit pipe Asian/Diamond make or PVC Casing capping MODI/Asian/Diamond make &Modular switches MK Blenz PLUS/ Legrand Myrius Nex Gen make with MS/PVC surface box & modular plate complete with connection & holder/ ceiling rose. Also to run an earth wire of 1sqmm all along the length of the point. Rate should be inclusive of breaking the wall finishing the surfacefor fixing pipes & accessories requied.(Length of light point will be 4mtrs, length above 4mtrs will be measured extra as per item no.3.(Light Points in Biuilding) |
| 2 | Wiring for surface/Concealed Ceiling Fan point with 2 x 1.5 Sq.mm PVC insulated FRLS wires copper conductorPolycab/Finolex/RPG make 1100Volts grade in PVC conduit pipe Asian/Diamond make or PVC Casing capping MODI/Asian/Diamond make &Modular switches MK Blenz PLUS/ Legrand Myrius Nex Gen make with MS/PVC surface box & modular plate complete with connection & holder/ ceiling rose. Also to run an earth wire of 1sqmm all along the length of the point. Rate should be inclusive of breaking the wall finishing the surfacefor fixing pipes & accessories requied.(Length of light point will be 4mtrs, length above 4mtrs will be measured extra as per item no.3.(Ceiling Points in Biuilding) |
| 3 | Wiring for circuit wiring with 2x1.5sqmm + 1 x 1.5 sqmm as earth PVC insu.copper cond. FRLS wires Polycab/Finolex/RPG make, 1100V grade in PVC conduit pipe Asina/Diamondin surface or Concealed manner make or PVC Casing capping MODI/Asian/ Diamond make including accessories & connections at both ends. Rate should be inclusive of breaking the wall finishing the surfacefor fixing pipes & accessories requied. (For light points above 4mtrs.) |
| 4 | Wiring for circuit wiring with 2x2.5sqmm + 1 x 2.5 sqmm as earth PVC insu.copper cond. FRLS wires Polycab/Finolex/RPG make, 1100V grade in PVC conduit pipe Asina/Diamondin surface or Concealed manner make or PVC Casing capping MODI/Asian/ Diamond make including accessories & connections at both ends. Rate should be inclusive of breaking the wall finishing the surfacefor fixing pipes & accessories requied. (circuit mains for lighting) |
| 5 | Wiring for circuit wiring with 4x2.5sqmm + 2 x 1.5sqmm as earth cond, PVC insu.copper cond. FRLS wires Polycab/Finolex/RPG make, 1100V grade in PVC conduit pipe Asina/Diamond or PVC casing capping MODI/Diamond make including accessories & connections at both ends.(circuit mains for lighting) |
| 6 | Wiring for circuit wiring with 2 x 4 sqmm PVC insu.copper cond. FRLS wires Finolex/Polycab/ RPG make, 1100V grade in Surface/Recessed PVCconduit pipe/PVC Casing capping Asian/Diamond/Modi make on surface /concealed including connections at both ends& to run PVC insucu earth wire of 4 sqmm green colour all along the length.Rate is inclusive of all the material required for the job (circuit mains for power points) |
| 7 | Wiring for circuit wiring with 4x 4 sqmm PVC insu.copper cond. FRLS wires Finolex/Polycab/RPG make, 1100V grade in Surface/Recessed PVCconduit pipe/PVC Casing capping Asian/Diamond/Modi make on surface /concealed including connections at both ends& to run PVC insucu earth wire of 2x4 sqmm green colour all along the length.Rate is inclusive of all the material required for the job (circuit mains for power points) |
| 8 | Supplying, Installation, Testing & commissioning fullyprewired modular typeLegrand( Myrius NextGen )/MK Blenz Plus :- Make switchboard withfollowing specifications.a) Moulded front plate with 3 module Cat no 679503),:---01 no.b) Modular surface box mounting box suitable for 3module (Cat No 673303).---01 no. c) 6 A. S.P.switch ( w/o indicator), Code No.679200:-01 no.d) 6Amp 5 pin Module, universal type socket,Code No.679235 :- 01 no. |
| 9 | (SITC of Modular Switch & socket on Tables board/on wall)Supplying,fixing,connecting fully prewired modular system typeLegrand( Myrius NextGen) /MK Blenz Plus:- Make switch board with following specifications.a)Moulded front plate with 8 module Cat no 679508),:--01 no. b) Surface Box mounting box suitable ,for 8module (Cat No 673308).--01 no. c) 16 A. S.P.switch, Code No.679209:-01 no.d) 6Amp Modular, universal type socket,Code No.679235 :- 02no. |
| 10 | (SITC of Modular Switch board forpower point )Supplying,fixing,connecting fullyprewired modular system typeLegrand( Myrius NextGen )/MK Blenz Plus :- Make switchboard withfollowing specifications.a) Moulded front plate with 12/16 module Cat no 679512),:---01 no. b) Metal mounting box suitable, for 16 module front plate (Cat No 689021).--01 no.c) 6 A. S.P.switch ( w/o indicator), Code No.679200:-03 nos.d) 6Amp 5 pin Module, universal type socket,Code No.679235 :- 03 nos.c) 16 A. S.P.switch, Code No.679209:-01 nos.d) 16 Amp/6Amp 3Module, universal type socket,Code No.679229 :- 01 nos. |
| 11 | Supplying, fixing& connecting on ceiling prewiredLED light fitting Recess muonting type Philips make cat No.RC380B G6 LED36S-6500 G6 L60W60 PSD OD S1/ or Eq of Wipro/Havells make, 2\"x2\" complete with hanging support from ceiling & Driver. The LED Light fiting should have minumum 3 years replacement warranty (For Gypsum/Armstrong false ceiling in Hall) |
| 12 | Supplying, fixing& connecting on False ceiling prewiredDown Light LED fitting recessed Type, roundPhilips make cat No. DN172 15S LED DL G2 (WW), 5700K, 15W/ Wipro Make / Havells\" Makecomplete with fixing arrangement & Driver.The LED Light fiting should have minumum 3 years replacement warranty. (For Gypsum/Armstrong false ceiling in Conference hall) |
| 13 | Supplying, fixing& connecting on ceiling prewiredLED light fitting Surface 4\" x 1\" Type 30-36WattsPhilips make cat No.SM270C LED 30S 6500K PSU WH32 watts/ Wipro Make Cat No.AURA PLUSCRCO13S038HP57G1, 30Watts/Havells\" Make Cat.No.PLANO Surface, 5700k,4\"x1 with suspension kitupto 1.5 mtr, complete with Driver.The fitting should be hung from the ceiling by using suspension kit fixed to the ceiling.The LED Light fiting should have minumum 3 years replacement warranty. (For Laboratories) |
| 14 | Supplying, fixing& connecting on ceiling/wall with prewired LED tube light fitting with metal body Philips make cat No.BN021C LED40S-6500 PSU CW GR(4Ft)/ Havells make cat no. Lumiline Plus 24W/ Wipro make, Philips make 22W, 4\"complete with accessories.The LED Light fiting should have minumum 3 years replacement warranty(General purpose) |
| 15 | Supplying,Installation, testing and commissioningof BLDC type,Ceiling fan of 1200mm, (48\")sweep, .Model:-CROMPTON, Model RIVIERA, BEE 5STAR Rated,360rpm, Single phase,or equvalent of Havells/Automberg.The rate includes :- Supply of3-core PVC flex.copper cond. cable, Anchor fastner of suitable size. |
| 16 | Supplying,Installation, testing and commissioningof Modular type Fan regulator two module , Legrand Myrius make cat No.679240 or equivalemt of MK /LK. of suitable size. |
| 17 | Supplying,Installation, testing and commissioningofIndustrial type, heavy duty Exhaust fan of 380mm, (15\")sweep,1400RPM.Model:-Turboforce SP,Make:-Havells (or Equivalent model of GE/Crompton )The rate includes :- Supply of3-core PVC flex.copper cond. cable, Anchor fastner of suitable size,25mm thick waterproof plywoodfor fixing Ex.fan or by fabricating suitable size of M.S. angle / flat frame.(For laboratories) |
| 18 | Supplying & fixing Exhaustfan GEC/Orientmake, Medium duty metal body, 225mm sweep in window complete with frame,brackets & louvers.(For Washroom) |
| 19 | Supplying & fixing & connecting Legrand /Siemens/ L&T make DPMCB 32 A,cat no. 408636in a metal enclosure of same make. Rate is inclusive ofenclosure, MCBs & connections. |
| 20 | Supplying & fixing & connecting Legrand /Siemens/L &T make FPMCB 32 A,cat no. 408699 in a metal enclosure of same make. Rate is inclusive ofenclosure, MCBs & connections. |
| 21 | Supplying & fixing completely assembled Legrand/Siemens/L&T(LK) make main Power VTPN distribution board, 3 phase 12way with4 poleMCB 63A cat No.408702--1No as incomer & TPMCB 25-32A- 4Nos. & 24 Nos of 6-20A SPMCBs Legrand makeas O\G. The distribution box should be fixed on wall with Anchor fastners. Enclosure should be double door type with IP 43 potection Legrand make,Cat No.507728 with cable end boxes. Rate is inclusive of Lexicmake metal enclosure,MCBs & cable end boxes. (For raw Power) |
| 22 | Supplying & fixing completely assembled MDS make main Power VTPN distribution board, 3 phase 8way with4 pole Legrand make MCB 63A cat No.408702--1No as incomer & TPMCB 25-32A- 3Nos. & 15 Nos of 6-20A SPMCBs Lexic makeas O\G. The distribution box should be fixed on wall with Anchor fastners. Enclosure should be double door type with IP 43 potection Legrand make,Cat No.507727 with cable end boxes. Rate is inclusive of Lexicmake metal enclosure,MCBs & cable end boxes. (For raw Power) |
| 23 | Supplying,fixing and laying on wall/through cable tray /through trench/on ceiling with proper saddeling/fixing ofPolycab/Finolex /Asian-Make, 3 1/2 core, 35 Sq.mm.,Al..conductor, XLPE insulated,1100 V grade armoured cable. The rate includes supply & laying of 2x14 SWG bare copper earthing wire throughout the length of cable. (From Basement panel to the Distribuiotn Board.) |
| 24 | Supplying,fixing and laying on wall/through cable tray /through trench/on ceiling with proper saddeling/fixing of Polycab/Finolex /Asian-Make, 4core, 4 Sq.mm.,Copper conductor, XLPE insulated ,1100 V grade armoured cable. The rate includes supply, fixing and termination of 2x14 SWG bare copper earthing wire throughout the length of cable.( For three Ph Acs) |
| 25 | Supplying,fixing and laying in a provided Casing capping PVC insulated copper conductor 0.5mm , 2 pair telephone cable. |
| 26 | Supplying,fixing and laying in a provided Casing capping/ PVC Conduit/ Race ways, CAT-6 Data cable. |
| 27 | Supplying,fixing & connecting Modular type , Legrand , myrius make Telephone socket with surface box & front plate. |
| 28 | Termination of3 1/2 core, 35 Sq.mm., Al conductor ,XLPE insulated ,1100 V grade armoured cable.with suitable size of aluminium Crimping type lugs ,gland (wherever required as perthe site condition). (Each termination willmeasured separately) |
| 29 | Termination of4 core, 4 Sq.mm., Copper. conductor,XLPE insulated ,1100 V grade armoured cable. with suitable size of gland (wherever required as perthe site condition). (Each termination willmeasured separately) |
| 30 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25mm with accessories on wall/ceiling , MODI/Diamond/Asian make. |
| 31 | Supplying & erecting HMS PVC conduit 32mm dia. with necessary accessories in wall/floor with chiselling appropriatelyof Asian/Diamond make |
| 32 | Dismantling the existing light ,fan plug point& ckt mains with VIR/PVC wire in casing capping, PVC pipe or MS conduit complete with fittings such as batten holder, ceiling rose, switches, regulators & refilling the holes with cement morter & finishing inan approved manner. Extreme care should be takenwhile removing wiring.Rate is inclusive of returning the removed material to NCL stores & transport required for the same. |
| 33 | Dismantling the existing Armoured cable upto the size of 3.5core 35 sqmm. From the wall, ceiling withput damaging the same. |