| 1 | Excavating in posts holes (or similar holes) in hard/dense soil each n.exc 0.50 cu.m getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm watering, and removing surplus soil to a distance n.exc 50m and making good surface. |
| 2 | M&L for providing PCC 1:3:6 type C2 using (40mm graded stone aggregate) in foundation filling and mass concrete. |
| 3 | S&F mild steel work as in Roof trusses (framed) trusses purlins and fastening (etc.,angle, channel,tubular section,round pipe) or flat section including distance pieces, MS plates/ gussetplates, cleats, hold fast etc. conforming to Gde of steel Fe 410-0 or Fe 310-0 complete all as specified and directed. |
| 4 | M & L for Preparation of new painted surface of steel and iron surface of anydescription and in any position over 10 cm width or girth andapplying two coat of synthetic enamel paintover one coat of redoxide primer all as specified and directed by Engr-in-Charge. |
| 5 | S &F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550MPa as in roof covering / cladding to wall, fixed with L or J hooks all as specified and directed. |
| 6 | S &F for pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550MPa as in ridge etcfixed with L or J hooks all as specified and directed. |
| 7 | Roughening of old unservicable PCC floorsurface by picking, chipping and wire brush sweeping clean and washing down with water to remove dust outside to make it suitable for laying floor tile complete all as specified. |
| 8 | M & L Hard core gauge not exc. 63mm of broken bricks diposited spread and levelled in layers not exc. 15 cm watered and rammed to a true surface complete all as specified. |
| 9 | M&L PCC 1:3:6 type C2 using 40mm graded stone aggregate as100mm thick finished fair all as speificed and directed |
| 10 | M & L for 75 mm thick PCC 1:3:6mix type C2 using 40mm graded stone aggregate as in paving finishing cone surface (plinth protection) even and smooth without using extra cement. |
| 11 | M & L for Filleting in any position and to any shape n. exc. 25 sq. cm in cement mortar 1:4 including all mitres, stops, etc. |
| 12 | M & L for prepolished chequered cement concrete tiles machine pressed 30cm x 30cm x 25mm thick, over cement screed base 15 mm thick in cement morter 1:4, set, jointed and pointed in neat cement slurry in floors etc complete as directed. |
| 13 | M&L Sand Filling a layer of 50mm thick sand cushioning including filling the joints with sand as in floors/ paths including watering and consolidation complete all as specified and directed. |
| 14 | M & L for80 mm thick, machine made ,1st quality, precastcement concrete rubber moulded coloured interlockingpaver blocks,of triangular / Zigzag / Haxagone/I , in shapeor shap and design as approved, with grey cement and pigment , having M-40 Gradeand conforming to IS 15658-2006 specifications, complete all as specified and directed. |
| 15 | M&L for factory made precast machine pressed kerb stones of PCC grade M-15 design mix and of shape and size rected, set jointed and pointed cement and sand mortar 1:4 fixed in repairs with and including necessary excavation and earthwork and making good the disturbed surfacesto match with the existing surfaces including removal of dispodal of rubbish complete all as specified and directed. Sizes shall be as under :- Length (L) not less than 300mm, Height (H) 300mm to 350mm, Thickness (T) 100mm and radius (R) 75mm including painting on kerb stone of synthetic enamel paint yellow or white colour complete all as specified and directed. |
| 16 | Excavationin trenches not exc1.5 m wide and not exc1.5 mtr depth for foundation etc n.exe 10sqm on plan in and getting out in hard dense soil. |
| 17 | M&L for providing PCC 1:4:8 type D2 using (40mm graded stone aggregate) in foundation, filling and mass concrete, levelling course etc. |
| 18 | Returning filling in including spreading, levelling, watering and well ramming in layer nexc 25 cm in soil |
| 19 | Removing excavated material soil n.exc. 500m and depositing where as directed |
| 20 | M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 mmean radius built in CM 1:6 |
| 21 | M & L Rendering 15 mm thick onfair faces of brick work or concrete surfaces of wall in cement mortar 1:6 for finished even and smooth (without using extra cement) |
| 22 | M & L Rendering 15 mm thick on brick masonaryother thanfair faces of brick work or concrete surfaces of wall in cement mortar 1:6 for finished even and smooth (without using extra cement) |
| 23 | M & L for preparation of newplasteredsurfaces of walls and applying two coats of cement base paint over a coat of primer maching to existing of wall surface. |
| 24 | M&L for PCC 1:3:6 type C1 (using 20mmgradedstone aggregate) as in copingexposed surfaces finished even and smooth using extra cement including necessary form work complete all as specified and directed by Engr-in-Charge. |
| 25 | M&Lfor sub main wiring with two single core PVC FRLS insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size1.5 sqmm (for main current) drawn in & incl PVC conduit not less than 20mm dia ISI markedwith all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of01 Single core of size 1.50 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green |
| 26 | M&Lfor sub main wiring with two single core PVC FRLS insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size2.5 sqmm (for main current) drawn in & incl PVC conduit not less than 20mm dia ISI markedwith all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of01 Single core of size 2.50 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green |
| 27 | Supply and fixing LED lights fittingmade of Aluminium extrusion 1x 20W (4 feet) , input voltage 140-270 V AC,CCT 6500K, Lumin efficency 100 lm/watt ,surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 , connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed byEngr -in -charge. Make Havells Cat part NoLUMILINEPLUSPROBS20WLED865SPCSSIND /Bajaj cat part No BCLAB 20W LED P or equivant make of list of makes as specifid in PS. Note Warrenty on light should be of minimum 02 Years. |
| 28 | S&F ceiling rose, surface backlit,three terminal. all as specified and directed by Engr in charge. |
| 29 | S&F testing and commissioning of MCB SP 5 Amp to 32 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs. |
| 30 | S&F testing and commissioning of MCB SPN 240 volt 40 Amp10 KA capacity having C-curve characteristics connected with suitable lugs including taking down. |
| 31 | S&F sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 4 way, 240 V with 200 Amps rated bus bar including taking down. |
| 32 | Supply and fixof 100 Watt LED flood light new generation energy saving and environmental friendly, long life, exclusive innovative die-cast aluminium IP65 protection and IK07 with 10KV Built-in-Surge Protection Device ,lumens should be ≥120 lm/w ,OEM driver ,PF 0.9,CCT 5700K flood light,suitable for highlighting architectural facade and general purpose lighting |
| 33 | Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volt grade cross sectional area 10sqmm 2 core as specified and directed. |
| 34 | M & L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable all as specified.(Note-only Punned thickness ie 18 mm thick will be measured for payment) |
| 35 | M & L well burnt bricks sub class \"B\" as in protection of cable laid dry, flat abutting each other width wise all as directed |