| 1 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables or other items and getting out complete all as specifed and directed. |
| 2 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed. |
| 3 | Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting pointcomplete all as specified and directed. |
| 4 | M & L for Sand cushioning for under ground cable upto 8 cm before laying the cable and 15 cm after laying and stretching the cable and punned down to form a bed to a minimum 23 cm. The punning shall be done by hand complete all as specified in clause 19.75 of SSR Part-I of 2009 and directed. |
| 5 | Material and labour for sub class \"B\" bricks well burnt of size laid dry flat for protection of cable complete all as specifiedand directed. |
| 6 | Material and labour for removing the old gravels and sand from sand filter and old activated carbon from carbon filter, cleaning the vessels from inside complete and supply and set as per belowBottom layer : 100mm thick of gravel of 20-40 mm nominal size.Third layer : 100mm thick of gravel of 12-20 mm nominal size.Second layer: 100mm thick of gravel of 2-6 mm nominal size.Top layer : 150mm thick of silica sand (1-2 mm size.)Activated Carbon : As per Site requirment. Note: Work for Sand filter and carbon filter vessels are considered in single job. |
| 7 | M & L for Dismantling/taking out blower motor for rewinding of capacity 20 HP motor of3 phase by using best quality super enamelled copper winding wire of existing gauge and existing Nos of turns including varnishing for \"F\" class insulation and drying in heat chamber and refixing testing, commissioning complete so as to have same RPM, complete all as specified and directed. |
| 8 | M & L for Dismantling/taking out motor stator for rewinding of capacity 12 HP motor of monoblock set, 3 phase by using best quality super enamelled copper winding wire of existing gauge and existing Nos of turns including varnishing for \"F\" class insulation and drying in heat chamber and refixing testing, commissioning complete so as to have same RPM, complete all as specified and directed. |
| 9 | M & L for Dismantling/taking out to motor/pumpfor rewinding of capacity 7.5 HP submersible Arreator pump set 3 phase by using best quality super enamelled copper winding wire of existing gauge and existing Nos of turns including varnishing for \"F\" class insulation and drying in heat chamberandincluding repair/replacement for defective parts such as bearing, shaft sleeves, gland plate, impeller, including replacement of worn out nuts, bolts, greasing of bearing, replacement of gaskit/mechanical seal, rotor shaft job, shaft coupling, spider etc or any other part completerefixing testing, commissioning complete so as to have same RPM complete all as specified and directed. |
| 10 | M & L for dismantling/taking out motor stator for rewinding of capacity 5 HP motor of monoblock set, 3 phase by using best quality super enamelled copper winding wire of existing gauge and existing Nos of turns including varnishing for \"F\" class insulation and drying in heat chamber and refixing testing, commissioning complete so as to have same RPM, complete all as specified and directed. |
| 11 | Supply and use of polyelectrolyte chemical for disinfection of raw sewage water, ISI marked complete all as specified and directed. |
| 12 | Supply and use of alum (Aluminium Sulphate) chemical for disinfection of raw sewage water, ISI marked complete all as specified and directed. |
| 13 | Supply and use of sodium hypochloride liquid chemical 100 GPL for treated sewage water, ISI marked complete all as specified and directed. |
| 14 | M&L for earthing complete with galvanised steel earth plate, electrode, 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to galvanised earth strip of size 25 x 4 mm by means of nuts, bolts, & washers of GI as shown in electrical plate No. 5 of SSR Part-I. Connected to earthing test point all as specified and including necessary earth pit PCC 1:3:6 chamber be 50mm thick PCC 1:2:4 chamber cover with 8mm dia mild steel TMT reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 32mm dia upto 7.5metre from the earth plate electrode & refillling of soil etc including necessary excavation & earth work in any strata and PCC chamber complete all as specified and directed including demolishion of old and unservicableexisting earth pit and removing from site. |
| 15 | Supply, fixing, connecting and testing street light LED INVERTOR type suitable for working on 230 volts, 50 Hz, AC of 45 WattsIncluding taking down complete all as specified and directed. |
| 16 | Dismantling/taking out non clogg submersible sewage pump set complete 7.5 HP and carrying out including repair/ replacement for defective parts such as bearing, shaft sleeves, gland plate, impeller, including replacement of worn out nuts, bolts, filling of pump oil heavy grade, greasing of bearing, replacement of gaskit/mechanical seal, rotor shaft job, shaft coupling, spider etc or any other part and reassmebling, testing & commissioning complete making it smooth functioning complete all as specified and directed. Note : 1. Rates for making arrangement for lifting up the non clogg sewage pump from inside well shalldeemed to be included in quoted rates. 2. Once the motor pump set repaired, the contractor shall by default get the bearing, and other necessary parts changed and shall remain responsible for proper functioning of motor pump. 3. The contractor should get the repairing work done at the installation site in presence of MES rep and only the rewinding and rotor job to be done outside defence land. |
| 17 | Dismantling/taking out non clog centrifugal/monoblock sewage pump set complete 5 HP and carrying out including repair/replacement for defective parts such as bearing, shaft sleeves, gland plate, impeller, including replacement of worn out nuts, bolts, filling of pump oil heavy grade , greasing of bearing, replacement of gaskit/mechanical seal, rotor shaft job, shaft coupling, spider etc or any other part complete all as directed and reassmebling, testing & commissioning complete making it smooth functioning complete all as specified and directed.Note:- 1. Rates for making arrangement for lifting up the non clogg sewage pump from inside well shalldeemed to be included in quoted rates. 2. Once the motor pump set repaired, the contractor shall by default get the bearing, and other necessary parts changed and shall remain responsible for proper functioning of motor pump. 3. The contractor should get the repairing work done at the installation site in presence of MES rep and only the rewinding and rotor job to be done outside defence land. |
| 18 | Dismantling/taking out non clog centrifugal/monoblock sewage pump set complete 7.5HP and carrying out including repair/replacement for defective parts such as bearing, shaft sleeves, gland plate, impeller, including replacement of worn out nuts, bolts, filling of pump oil heavy grade, greasing of bearing, replacement of gaskit/mechanical seal, rotor shaft job, shaft coupling, spider etc or any other part complete all as directed and reassmebling, testing & commissioning complete making it smooth functioning complete all as specified and directed.Note:- 1. Rates for making arrangement for lifting up the non clogg sewage pump from inside well shalldeemed to be included in quoted rates. 2. Once the motor pump set repaired, the contractor shall by default get the bearing, and other necessary parts changed and shall remain responsible for proper functioning of motor pump. 3. The contractor should get the repairing work done at the installation site in presence of MES rep and only the rewinding and rotor job to be done outside defence land. |
| 19 | Material and Labour for dismantling the Blower unit complete from STP No-1, STP-2, Janglot STP & Bana singh STP and carrying out repair/replacement for defective parts such as bearing, shaft sleeves, gland plate, impeller, including replacement of worn out nuts, bolts, filling of blower oil heavy grade, greasing of bearing, replacement of gaskit, mechanical seal, rotor job etc complete all as directed and reassembling, testing & commissioning complete all as specified and directed. Note:- Once the blower unit repaired, the contractor shallremain responsible for proper functioning of blower assembly. |
| 20 | Repair and servicing of 2 HP motor of clarisetteler 3 phase 415 volt providing insulation including tightening of chain mechanism, varnishing, heating, replacement of suitable bearing, seals, gaskets, worn out carbon brushes, rotor job, couplings or any other part etc complete testing all as required for completion of JOB.Note:- 1. Rates for making arrangement for lifting up motor from site shall be deemed included in quoted rates. 2. Once the motor repaired, the contractor shall by default get the bearing, and other necessary parts changed and shall remain responsible for proper functioning of motor. |
| 21 | M & L for Cleaning of sewage incoming well of size 22 Ft X 22 Ft and depth 28Ftlocated at sewage treatment plant with man power and T&P (Tools and plants) such as pump set for De-watering and cleaning upto bottom of the well with all complete safety equipment and lifting of sludge by means of Hydra and taking out all clay/sludge/mud/stone pieces and other material deposited in the sewage well during course of time and removing deposited material to a distance from 250 mtr of the cantonment arera of the Basoli & Janglotin a four months interval complete all as specified and directed. (At MAP STP)Note: (i) Rates for arranging machineries for carrying out the job deemed to be included in quoted rates. |
| 22 | Cleaning of arreator well sump of size 10 mtrx 5 mtr x 3 mtr at sewage treatment plant STP-1) with all man power and T&P(Tools and plants) required to pump out existing water and removing the sludge and greet from deep water collector with all safety equipment and throwing it to place outside the STP area complete including painting properly inside complete all as specified and directed. |
| 23 | M & L for Cleaning of sewage Stilting Chamber by opening including sewage transfer pipes of mixing chamber near stilling tank, Bio Reactor -I, Bio Reactor-II,treated water & filter feed tank/sump, Rotating clarisettler chamber by removing and washing all fiber pens and resettling after cleaning complete located at sewage treatment plant with man power and T&P (Tools and plants) such as pump set for De-watering, tripod, chain pully, rope, steel bucket, phawara etc all required for completion of Job for cleaning upto bottom of the well and taking out all clay/sludge/mud/stone pieces and other material deposited in the sewage well during course of time and removing deposited material to a distance of 50 mtr from the site of well thereafter applying one coat of approved paint inside complete all as specified and directed.Note: (i). Rates for making arrangement of cleaning of 5.5m deep Stilling Chamber,Bio reactor I&II, 2.5m deep filter feed sump and treated water sump is considered as one job & including of painting inside shall deemed to be considered in quoted rates. |
| 24 | M & L for Cleaning of sewage drying bed of size 25Ft X 25 Ft and depth 4 Ft located at sewage treatment plant with man power and T&P (Tools and plants) cleaning upto bottom of the bed with all complete safety equipment and lifting of sludge by means of Hydra and taking out all clay/sludge/mud/stone pieces and other material deposited in the sewage well during course of time and removing deposited material to a distance of 100 mtr from the site of the well complete all as specified and directed.Note: Rates for arranging machineries for carrying out the job deemed to be included in quoted rates. |
| 25 | M & L for scrapping/cleaning of outer surfaces of Air Blower, Treated water pump, Pressure feed pump, Clarisetter motor gear set and other motors and spray painting with two coats of best qualitiy sythetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 26 | M & L for scrapping/cleaning of outer surfaces of Pipes of any size and any type and Headers and spray painting with two coats of best qualitiy MS sythetic anticorrosive bitumin paint over one coat of red oxide primer(colour as per approved by GE) complete including marking and writing details all as specified and directed. |
| 27 | Supply and fix in repair of bellow type PVC flexible pipe (heavy duty) of size 80 mm dia for sewage system, ISI marked complete all as specified and directed. |
| 28 | Supply and fix in repair star delta starter CE certified for 7.5HP motor 415 V, 50 Hz capacity and IS-13947-4-1 complete all as specified and directed. |
| 29 | Supply and fix in repair star delta starter CE certified for 5 HP motor 415 V, 50 Hz capacity and IS-13947-4-1 complete all as specified and directed. |
| 30 | Supply and fix in repair of contactor CE certified for 7.5/5 HP motor starter 415 V, 50 Hz capacity complete all as specified and directed. |
| 31 | Supply and fix in repair of overload and single phasing relay suitable for 6-10 Amp for 7.5/5 HP motor starter panel 415 V, 50 Hz capacity complete all as specified and directed. |
| 32 | Supply and fix in repair butterfly valve stainless steel shaft and CI body with cruch handle, PN-1.0 of following sizes :- |
| 33 | 80mm Size |
| 34 | 100mm Size |
| 35 | Supply and fix in repair pressure gauge 0-4 kg/cm²/0-60 Psi SS316 existing at site analog type complete all as specified and directed. |
| 36 | Supply and fix in repair pressure gauge 0-60 kg/cm² SS316 existing at site analog type complete all as specified and directed. |
| 37 | Supply and laying MS Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings/Sewage well etc of following sizes including taking down old unservicable existing pipe complete all as specified and directed.Note: (i) Fixing/laying includes welding works as persite requirement. (ii) The rates of proper welding in and including flanges and smoothing the surface deemed included in quoted rates. |
| 38 | 80 mm bore size |
| 39 | 100 mm bore size |
| 40 | S&F in repairs Dosing Pump, Capacity: 5.76 lph, Pressure: 10 kg/cm2, Make: Unichlor, Declibec,Milton Ray Type: Electronic, MoC of Head: PP, Mounting: Top Mounted, PowerSupply: 240 V Ac. Single - Phase, 54 W with standard accessory complete all as specified and directed. |
| 41 | Supply and laying or fixing of cable passing through pipe 1100 volts grade heavy duty submersible cable with PVC insulated 4 sqmm 3 core copper conductor unarmoured including connections including taking down old unservicable cable complete all as specified and directed. |
| 42 | Supply andlaying XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with standard aluminium conductor 10 sqmm 2.0 core complete all as specified and directed. (Note: necessary excavation, removal, returning filling, sand cushioning, brickshall be measured and paid under respective item of Sch/BOQ). |
| 43 | Supply andlaying XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with standard aluminium conductor 35 sqmm 3.50 core complete all as specified and directed. (Note – necessary excavation, removal, returning filling, sand cushioning, brickshall be measured and paid under respective item of Sch/BOQ.). |
| 44 | Supply and laying XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with standard aluminium conductor 50 sqmm 3.50 core complete all as specified and directed. (Note – necessary excavation, removal , returning filling, sand cushioning, brickshall be measured and paid under respective item of Sch/BOQ.). |
| 45 | S&F in repair of HDPE pipe PE 10 PN 8 as per IS 4984 complete of size 100mm dia complete all as specified and directed. |
| 46 | S&F in repair of GI pipe of \"Medium grade\" of size 50 mm with all fitting, laid in trenches complete all as specified and directed. |
| 47 | M&L for oiling and greasing of pump motor parts (any make any size) by means of greasing gun or manually by unbolting and separating the pump motor set complete for smooth operation of machinery complete making it leakage free and applying galnd packing of necessary quantity and making working noise and leakage free complete all as specified and directed. |
| 48 | Supply and fix in repair of FRP made Junction box of size 300mm x 200mm with provision of seprators and connectors for three phase motors connection/ for lights with closing arrangement and fixing on wall complete all as specified and directed. |
| 49 | S&F in repair indicator board of size 250mm x 100mm made of acrylic/PVC for indication of section of plant such as Main well, Aireator tank, settling tank, recycle tank, DG set room, Pump room etc in base of blue colour and writeup in white colour stencil cut duly pasted on it and size of letter as directed by Engr-in-Charge complete all as specified and directed. |
| 50 | M & L for testing of water sample at authorised government laboratory for BOD and COD of water including glass bottle for collection of sample. Note: Sample of water to be collected from wherever directed will be responsibility of contractor. (Water sample to be taken from STP) |
| 51 | Taking out the old unserviceable /burnt MCCBs of various capacity and make from different LT panels after proper shutdown from the respective sub station and supply and fix new MCCB 200 amps, 4 pole 415 volts, 3 phase, 50 Hz AC with Microprocessor Release MTX2.0 & iTRP3 suitable for 415 Volt & 25 kA breaking capacity. The MCCB should have Ics= 100% Icu for short circuit breaking capacity of minimum 36 kA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as standard feature of manufacturer, make of MCCBs: Siemens (3VL)/Legrand (DPX3)/ ABB (Tmax), Schneider Compact (NSX)/L&T CM92109OON1OG. |
| 52 | Supply and fix in repair single phase preventor suitable for 3 phase motor of any make any size all as per sample complete all as specified and directed. |
| 53 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty roundcable with PVC insulated copper conductor served with an inner sheathing of PVC tapeunarmoured overall PVC sheathed 6 sqmm nominal cross section 4 Core solid conductor including taking out old unservicable exising cable complete all as specified and directed. |
| 54 | M & L for Framed work for foundation frame of motors using angle or other section with gasket plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete with locking arrangement complete all as specified anddirected. |
| 55 | Supply and fixing of PVC water tank of heavy duty triple layers at existing placeof capacity 200 Litres incl fixing of nacessary arrangement such as inlet and outlet water connections of suitable size of pipes including dismentalling of old one complete all as specified and directed. |
| 56 | S & F of fan belt for compressor to motor of suitable size and type complete all asspecified and directed |