| 1 | Materials and Labour for flushing condenser, cooling coil and refrigerant pipe line of the window type AC of capacity 1.0TR/1.5TR including complete removal of dust, dirt, bugs, grease, oil etc., brazing the leakages if any in connection pipes of compressor, condenser, cooling coil, pressure testing, checking for leaks, dehydrating and vacumizing to the standard as per OEM\"s reccommendations, charging of referigerant as per OEM\"s reccommendations and including testing and commissioning, complete all as specified and directed. Note :- Spares will be measured and paid seprately under relevant items. |
| 2 | Supply, installation, testing and commissioning of sealed compressor suitable for window type AC of 1.0TR/1.5 TR capacity as per OEM\"s specifications including charging of Nitrogen gas, leak testing etc., including flushing condenser and cooling coil, complete removal of dust, dirt, bugs, grease, oil etc., brazing the lekages if any in condenser, cooling coil, pressure testing, checking for leaks, dehydrating and vacumizing to the standard as per OEM\"s reccommendations and including taking down carefully existing unserviceable compressor complete all as specified and directed. |
| 3 | Servicing/Cleaning of existing Window Type Air Conditioner 1.0TR/ 1.5TR capacity by removing the unit, cleaning of filters, removing of dust, checking of all parts etc. and refixing in the existing place complete all as specified and directed. Note :- Spares will be measured and paid seperately. |
| 4 | Supply only capacitor 4Mfd/6 Mfd, 230 Volt, 50 Hz suitable forwindow type AC as per OEM recommendation complete all as specified and directed. |
| 5 | Supply only running capacitor 45+5 Mfd, 230 Volt, 50 Hz suitable for window type AC as per OEM recommendation complete all as specified and directed. |
| 6 | Supply only copper stainer filter cum dryier made of copper suitable for window type AC as per OEM recommendation complete all as specified and directed. |
| 7 | Supply only, fan & blower motor, single phase, 230 Volts, 50Hz,1/4 HP / 1/6 HP suitable for 1.0TR/1.5TRwindow type Air Conditioner as per OEM\"s specifications complete all as specified and directed. |
| 8 | Supply, installation, testing and commissioning of sealed compressor, any type, including charging of Nitrogen gas, leak testing etc., suitable for outdoor unit of split type Air Conditioner of 1.0TR/1.5 TR capacity as per OEM\"s specifications including flushing inter connection pipes, condenser and cooling coil, complete removal of dust, dirt, bugs, grease, oil etc., brazing the lekages if any in connection pipe, condenser, cooling coil, pressure testing, checking for leaks, dehydrating and vacumizing to the standard as per OEM\"s reccommendations and including taking down carefully existing unserviceable compressor complete all as specified and directed. |
| 9 | Supply, installation, testing and commissioning of sealed compressor, rotary type, including charging of Nitrogen gas, leak testing etc., suitable for outdoor unit of split any type Air Conditioner of 2.0 TR capapicy as per OEM\"s specifications including flushing inter connection pipes, condenser and cooling coil with CO2/ Nitrogen, complete removal of dust, dirt, bugs, grease, oil etc., brazing the lekages if any in connection pipe, condenser, cooling coil, pressure testing, checking for leaks, dehydrating and vacumizing to the standard as per OEM\"s reccommendations and including taking down carefully existing unserviceable compressor complete all as specified and directed. |
| 10 | Supply,istallation,testing and commissioning of sealed compressor,reciprocating type,including charging of Nitrogengas, leak testing etc.,suitable for outdoor unit of split type Air Conditioner of 2.0TR capapicy as per OEM\"s specifications including flushing inter connection pipes,condenser and cooling coil with CO2/Nitrogen, complete removal of dust,dirt,bugs,grease,oil etc.,brazing the lekages if any in connection pipe,condenser,cooling coil, pressure testing,checking for leaks, dehydrating and vacumizing to the standard as per OEM\"s reccommendations and including taking down carefully existing unserviceable compressor,complete all as specified and directed. |
| 11 | Servicing/Cleaning of existing Split any type of Air Conditioner capacity 1.0TR/1.5TR/2.0TR by opening the indoor & outdoor units, cleaning of filters, removing of dust, checking of all parts etc. complete all as specified and directed. Note :- Spares will be measured and paid seprately under relevant items. |
| 12 | Supply Only, running capacitor, 45 Mfd, 440V AC, 50 Hz conforming to IS: 2993, suitable for split type AC, as per OEM\"s specifications complete all as specified and directed. |
| 13 | Supply Only, running capacitor, 50 Mfd, 440V AC, 50 Hz conforming to IS: 2993, suitable for split type AC, as per OEM\"s specifications complete all as specified and directed. |
| 14 | Supply Only, start capacitor 100 to 120 Mfd, 250 V AC, 50 Hzsuitable for outdoor unit of split type AC, as per OEM\"s specifications complete all as specified and directed. |
| 15 | Supply Only, fan & blower motor capacitor 6 Mfd440V AC 50 Hz for outdoor unit of Split type AC as per OEM\"s specifications complete all as specified and directed. |
| 16 | Supply Only, fan & blower motor capacitor 2.5 Mfd440V AC 50 Hz for outdoor unit of Split type AC as per OEM\"s specifications complete all as specified and directed. |
| 17 | Supply Only, universal control system kit with wireless remote and sensors for split type/window type air conditioner as per OEM\"s specifications. |
| 18 | Supply Only, PVC Fan Blade suitable for fan & blower motor of outdoor unit of split type air conditioner as per OEM\"s specifications complete all as specified and directed. |
| 19 | Supply Only, PVC Fan Blade suitable for fan & blower motor of indoor unit of cassette type air conditioner as per OEM\"s specifications complete all as specified and directed. |
| 20 | Supply Only, Starting Relay for compressor of Window/Split type AC of 1.5/2.0 TR capapicy as per OEM\"s specifications complete all as specified and directed. |
| 21 | Supply Only, copper pencil type stainer, 4mm wall thickness, suitable for window/ split type AC as per OEM\"s specifications complete all as specified and directed. |
| 22 | Supply Only, fan & blower motor of out door unit of 1.5 TR/ 2 TR capacity split type ACas per OEM\"s specifications complete all as specified and directed. |
| 23 | Supply Only, fan & blower motor of indoor unit of 1.5 TR/ 2 TR capacity split type ACas per OEM\"s specifications complete all as specified and directed. |
| 24 | Supply Only, EPDM rubber hose pipe, 20mm dia., pressure rating 0.3mpa-1.2mpa suitable for drain pipe connection for condensed water of split type/window type air conditioners complete all as specified and directed. |
| 25 | Supply Only, plunger contact suitable for window/split type AC of capacity 1TR/1.5TR/2TR as per OEM\"s specifications complete all as specified and directed. |
| 26 | Supply and Fix in repair, copper capillary tube 1/2\" complete with insulation as per OEM\"s specifications for interconnection of indoor and outdoor units of split type ACs complete all as specified and directed. |
| 27 | Supply and Fix in repair,copper capillary tube 5/8\" complete with insulation as per OEM\"s specifications for interconnection of indoor and outdoor units of split type ACs complete all as specified and directed. |
| 28 | Supply and Fix in repair,copper capillary tube 3/8\" complete with insulation as per OEM\"s specifications for interconnection of indoor and outdoor units of split type ACs complete all as specified and directed. |
| 29 | Supply and Fix in repair,copper capillary tube 1/4\" complete with insulation as per OEM\"s specifications for interconnection of indoor and outdoor units of split type ACs complete all as specified and directed. |
| 30 | Materials and Labour for flushing refrigerant pipe of the split type AC of capacity 1.0TR/1.5TR, pressure testing, checking for leaks, dehydrating and vacumizing hermetically sealed compressor to the standard as per OEM\"s reccommendations, charging of referigerant as per OEM\"s reccommendations and including testing and commissioning complete all as specified and directed. |
| 31 | Materials and Labour for flushing refrigerant pipe of the split type AC of capacity 2.0 TR, pressure testing, checking for leaks, dehydrating and vacumizing hermetically sealed compressor to the standard as per OEM\"s reccommendations, charging of referigerant as per OEM\"s reccommendations and including testing and commissioning complete all as specified and directed. |
| 32 | Supply and Fix in repair,condenser coil assembly complete suitable for 1.0TR/1.5 TR split type air conditioner as per OEM\"s specifications complete all as specified and directed. |
| 33 | Supply and Fix in repair,condenser coil assembly complete suitable for 2.0 TR split type air conditioner as per OEM\"s specifications complete all as specified and directed. |
| 34 | Dismantaling of fan & blower motor from outdoor unit of existing split type air conditioner of capacity 1.5/2.0 TR,removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding motor with super enamelled copper wires of existing size/gauge including provision of all insulating materials, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts, re-assembling to the existing place including testing and commissioning complete all as specified and directed. |
| 35 | Supply and Fix in repair,PCB for inverter type, suitable for outdoor unit of 1.0TR/1.5TR capacity split type air conditioner, as per OEM\"s specifications complete all as specified and directed. |
| 36 | Supply and Fix in repair, PCB for inverter type, suitable for outdoor unit of 2TR capacity split type air conditioner, as per OEM\"s specifications complete all as specified and directed. |
| 37 | Supply and Fix in repair, PCB, for inverter type, suitable for indoor unit of 1.5 TR capacity split type air conditioner, as per OEM\"s specifications complete all as specified and directed. |
| 38 | Supply and Fix in repair, PCB for inverter type, suitable for indoor unit of 2TR capacity split type air conditioner, as per OEM\"s specifications complete all as specified and directed. |
| 39 | Supply and Fix in repair, PCB for non inverter type, suitable for indoor unit of 2TR capacity split type air conditioner, as per OEM\"s specifications complete all as specified and directed. |
| 40 | Supply and Fix in repair, PCB for non inverter type, suitable for outdoor unit of 2TR capacity split type air conditioner, as per OEM\"s specifications complete all as specified and directed. |
| 41 | Supply and Fix in repair, PCB for non inverter type, suitable for outdoor unit of 1.5TR capacity split type air conditioner, as per OEM\"s specifications complete all as specified and directed. |
| 42 | Supply and Fix in repair, PCB for non inverter type, suitable for indoor unit of 1.5TR capacity split type air conditioner, as per OEM\"s specifications complete all as specified and directed. |
| 43 | Disconnecting all electrical and piping connections from existing window/split type air conditioner of capacity 1.0TR/1.5/2.0TR,taking down carefully the same including all accessories complete all as specified and directed. Note :- Existing window/split type air conditioner(s) obtained at site shall be deposited to MES Store Yard of AGE (E/M), GE (P) AF Digaru. |
| 44 | Supply and Fix in repair, voltage stabilizer for automatic operation, single phase, naturally air cooled designed for input voltage variation between 140V to 280V with output voltage stabilized at 230V with accuracy of + 2.5%,capacity 5 KVA complete all as specified and directed. |
| 45 | Supply and Fix in repair,voltage stabilizer for automatic operation, single phase, naturally air cooled designed for input voltage variation between 140V to 280V with output voltage stabilized at 230V with accuracy of + 2.5%,capacity 4 KVA, complete all as specified and directed. |
| 46 | M&L for shifting of split AC unit any type & capacity including dismantling of indoor and outdoor unit and mounting arrangement and refixing in new location by fixing mounting arrangement, topping up gas complete all as specified and directed. |
| 47 | Supply and Fix in repair,mild steel powder coated wall mounting bracket with load carrying capacity not less than 150 Kgs,suitable for installation of outdoor unit of split type air conditioner of capacity 1.0TR/1.5TR/ 2.0TR, including necessary nuts, bolts, washers and wall fasteners complete all as specified and directed. |
| 48 | Disconnecting electrical and water supply connections from the existing water coolers of any make, type and capacity including removing the same to and fro service centre for repairs complete all as specified and directed. |
| 49 | Material and Labour for repair to unserviceable storage type water cooler of any make and capacity by replacement of damaged legs with new legs fabricated out of mild steel sections as per existing pattern, painting of new mild steel surfaces with two coats of synthetic enamel paint (any tint) over a coat of red oxide zinc chromate primer, flushing refrigerant pipe, pressure testing, checking for leaks, dehydrating and vacumizing hermetically sealed compressor to the standard as per OEM\"s reccommendations, charging of referigerant as per OEM\"s reccommendations and including installation in original location, testing and commissioning, complete all as specified and directed.Note :- Spares for replacement will be measured and paid seperately under respective items of this BOQ. |
| 50 | Supply Only, water cooler thermostat assembly suitable for water cooler of any capacity, complete all as per OEM\"s specifications & directed. |
| 51 | Supply Only, concussive push button taps of cast copper alloy, chromium plated, screwed for outlet pipe of water cooler of any capacity, complete all as per OEM\"s specifications & directed. |
| 52 | Supply Only,water cooler motor with cooper winding, single phase AC, 230 Volts, capacity 1/8 HP suitable for water cooler of approx storage and nominal cooling capacity 40/80 Litres, complete all as per OEM\"s specifications & directed. |
| 53 | Supply Only, PVC fan blade of cooler motor suitable for water cooler of approx storage and nominal cooling capacity 40/80 Litres, complete all as per OEM\"s specifications & directed. |
| 54 | Supply Only, PVC connections 15 mm size with PTMT nuts of length 600 mm, complete all as specified & directed. |
| 55 | Supply Only, running capacitor, capacity 15/20 mfd, 240 Volt, AC, 50 Hz suitable for storage type water coolers, complete all as per OEM\"s specifications & directed. |
| 56 | Supply Only, start capacitor 60 to 80 Mfd, 240 V AC, 50 Hzsuitable for storage type water coolers, complete all as per OEM\"s specifications & directed. |
| 57 | Supply Only, start capacitor 80 to 100 Mfd, 240 V AC, 50 Hzsuitable for storage type water coolers, complete all as per OEM\"s specifications & directed. |
| 58 | Supply Only, compressor starting relay with overload protector suitable for storage type water coolers, complete all as per OEM\"s specifications & directed. |
| 59 | Materials and Labour for painting of water cooler of approx storage and nominal cooling capacity 40/80 Litres, complete with synthetic enamel paint by spraying including filling cavities with filler, onecoat after cleaning all dust etc. including writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30 cm high, stops commas, short lines, dashes, hyphens, brackets etc. for marking SM/MES No, Capacity etc., complete all as specified and directed. |
| 60 | Materials and Labour for painting of water cooler of approx storage and nominal cooling capacity 60/120 Litres, complete with synthetic enamel paint by spraying including filling cavities with filler, onecoat after cleaning all dust etc. including writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30 cm high, stops commas, short lines, dashes, hyphens, brackets etc. for marking SM/MES No, Capacity etc., complete all as specified and directed. |
| 61 | Supply, installation, testing and commissioning of sealed compressor suitable for 200/250 Liters capacity deep freezer as per OEM\"s specifications,including charging of Nitrogen gas, leak testing etc., flushing inter connection refrigerant pipes, brazing the lekages if any in connection pipe, condenser, cooling coil, pressure testing, checking for leaks, dehydrating and vacuumizing to the standard as per OEM\"s reccommendations and including taking down carefully existing unserviceable compressor, complete all as specified and directed. |
| 62 | Supply, installation, testing and commissioning of sealed compressor suitable for 210/215 Litres capacity refrigerator as per OEM\"s specifications, including charging of Nitrogen gas, leak testing etc., flushing inter connection refrigerant pipes, brazing the lekages if any in connection pipe, condenser,cooling coil, pressure testing, checking for leaks, dehydrating and vacuumizing to the standard as per OEM\"s reccommendations and including taking down carefully existing unserviceable compressor, complete all as specified and directed. |
| 63 | Supply, installation, testing and commissioning of sealed compressor suitable for 290/300/310/320 Litres capacity refrigerator as per OEM\"s specifications, including charging of Nitrogengas,leak testing etc., flushing inter connection refrigerant pipes,brazing the lekages if any in connection pipe, condenser, cooling coil, pressure testing, checking for leaks, dehydrating and vacuumizing to the standard as per OEM\"s reccommendations and including taking down carefully existing unserviceable compressor, complete all as specified and directed. |
| 64 | Supply, installation, testing and commissioning of sealed compressor, including charging of Nitrogengas, leak testing etc.,suitable for water cooler of approx storage and nominal cooling capacity 40/80 Litres as per OEM\"s specifications including flushing inter connection pipes, condenser and cooling coil, brazing the lekages if any in connection pipe, condenser, cooling coil, pressure testing,checking for leaks, dehydrating and vacuumizing to the standard as per OEM\"s reccommendations and including taking down carefully existing unserviceable compressor, complete all as specified and directed. |
| 65 | Supply, installation, testing and commissioning of sealed compressor, including charging of Nitrogengas, leak testing etc.,suitable for water cooler of approx storage and nominal cooling capacity 60/120 Litres as per OEM\"s specifications including flushing inter connection pipes, condenser and cooling coil, brazing the lekages if any in connection pipe,condenser, cooling coil, pressure testing, checking for leaks, dehydrating and vacuumizing to the standard as per OEM\"s reccommendations and including taking down carefully existing unserviceable compressor, complete all as specified and directed. |
| 66 | Supply and Fix in repair,ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for water inlet pipe of water coolers 40/60/80 Ltrs capacity, complete all as per OEM\"s specifications and directed. |
| 67 | Disconnecting electrical connections and taking down carefully existing unserviceable refrigerator/ deep freezer any make, type and capacity, removing & repairing the same item including re-installation of the same in original position complete all as specified & directed.Note :- Spares will be measured and paid seprately under relevant items of this BOQ. |
| 68 | Supply Only, compressor start relay, with overload protector suitable for refrigerators of capacities 165/300/320 Litres complete all as per OEM\"s specifications & directed. |
| 69 | Supply Only, transperant acrylic chiller door with lock compatible with refrigerators of capacities 290/300/310/320 Liters complete all as per OEM\"s specifications & directed. |
| 70 | Supply Only, thermostat with knob compatible with single door refrigerators of capacities 165/180/175/215 Liters complete all as per OEM\"s specifications & directed. |
| 71 | Supply Only, evaporator assembly (cooling chamber) compatible with refrigerators of capacity 290/300/310/320 Liters complete all as per OEM\"s specifications & directed. |
| 72 | Supply Only, refrigeration coil assembly (condenser coil) compatible with single door refrigerators of capacities 165/180/175/215 Liters, complete all as per OEM\"s specifications & directed. |
| 73 | Supply Only, refrigeration coil assembly (condenser coil) compatible with refrigerators of capacities 290/300/310/320 Liters complete all as per OEM\"s specifications & directed. |
| 74 | Supply Only, copper filter drier (pencil stainer) compatible with refrigerators and water coolers complete all as per OEM\"s specifications & directed. |
| 75 | Supply Only, thermostat assembly with knob compatible with deep freezer of capacity 320 Liters complete all as per OEM\"s specifications & directed. |
| 76 | Materials and Labour for flushing refrigerant pipe of the refrigerator of capacities 210/220/310/320 Liters, pressure testing, checking for leaks, dehydrating and vacuumizing hermetically sealed compressor to the standard as per OEM\"s reccommendations, charging of referigerant as per OEM\"s reccommendations and including testing and commissioning complete all as specified and directed. |
| 77 | Materials and Labour for flushing refrigerant pipe of the water cooler of approx storage and nominal cooling capacity 40/80 Litres, pressure testing, checking for leaks, dehydrating and vacuumizing hermetically sealed compressor to the standard as per OEM\"s reccommendations, charging of referigerant as per OEM\"s reccommendations and including testing and commissioning, complete all as specified and directed. |
| 78 | Materials and Labour for flushing refrigerant pipe of the water cooler of approx storage and nominal cooling capacity 60/120 Litres, pressure testing, checking for leaks,dehydrating and vacuumizing hermetically sealed compressor to the standard as per OEM\"s reccommendations, charging of referigerant as per OEM\"s reccommendations and including testing and commissioning, complete all as specified and directed. |
| 79 | Materials and Labour for flushing refrigerant pipe of the Deep Freezer of capacity 300/320/380/400 Liters, pressure testing, checking for leaks,dehydrating and vacumizing hermetically sealed compressor to the standard as per OEM\"s reccommendations, charging of referigerant as per OEM\"s reccommendations and including testing and commissioning, complete all as specified and directed. |
| 80 | Supply and Fix in repair, PCB for Refrigerator of capacity 165 Ltr to 200 Ltr, as per OEM\"s specifications, complete all as specified and directed. |
| 81 | Supply and Fix in repair, PCB for Refrigerator of capacity 300 to 320 Ltr, as per OEM\"s specifications, complete all as specified and directed. |
| 82 | Supply and Fix in repair, PCB for Deeep Freezer of capacity 200 Ltr to 260 ltr, as per OEM\"s specifications, complete all as specified and directed. |
| 83 | Supply and Fix in repair, PCB for Deeep Freezer of capacity 300 Ltr to 400 ltr, as per OEM\"s specifications, complete all as specified and directed. |
| 84 | Taking down carefully existing unserviceable sub main wiring of any size (2 runs single core including earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc. of any size complete all as specified and directed. |
| 85 | Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 4.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing and capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 4.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring, complete all as specified and as directed. |
| 86 | M&L forsubmain wiring with two single core FRLS PVC insulated multi strandedcopper conductor cable4 Sqmmincluding rigid heavy duty PVC conduit size 20/25 mm dia in existing surfaceincluding all accessories along with 4.0 Sq mm PVC insulated copper standard conductor earth wire connected to main wring system including taking down old unsv submain wiring complete all as specified and as directed. |
| 87 | Supply and Fix in repairs,single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 240V, complete all as specified and directed. |
| 88 | Supply and fixing in repair/replacement of Connection lead wire, two core with PVC insulated and sheathed copper cable size 2.5 Sqmm including earth wire complete all as specified and as directed. |
| 89 | Material & Labour in repair for unplasticised CPVC pipe of pressure rating100 Kg/Cm2 fixed complete to walls, ceilings or in floors etc of size 20mm dia (outer dia) AC drain out pipe including chase cutting on wall & making good as per existing complete all as specified and as directed. |
| 90 | S&F MCB, SPN DB, 4 ways double door, Metal door, 200A rated bus bars,earth bar, neutral links complete incl. blanking plates as required & fixed flush to wall and making good the disturbed surfaces including dismentling/taking down old unsvericeable one complete all as specified and as directed. |
| 91 | S&F MCB SPN 32 Amps 240, 50 Hz, breaking capacity 10 KA,\"C\" series. Including dismentling/taking down old unsvericeable one complete all as specified and as directed. |
| 92 | S&F MCB SP, 10KA, 230V, C-curve, 6-32 amps including dismentling/ taking down old unsv one complete all as specified and as directed. |
| 93 | S&F Plug top of three pin for capacity 15 Amp, 10KA,230V,including dismantling/taking down old unsv one complete all as specified and as directed. |
| 94 | S&F Plug top of three pin for capacity 5 Amp, 10KA, 230V, including dismantling/taking down old unsv one complete all as specified and as directed. |