| 1 | SCHEDULE-A Earth work excavation of foundation in hard soil within 50m initial lead and 1.5m lift |
| 2 | Filling F &P with sand well watered and rammed |
| 3 | CC(1:4:8) using 4 cm size h.g.crusher broken metal |
| 4 | Fly ash.Brick work in CM(1:6) in (25cm x12 cm x8cm) having crushing strength not less than 75kg/cm2 with dimensional tolerance +8% in F& P |
| 5 | RCC (1:2:4) using 12mm size c.b.h.g.chips including hosting and lowering,laying and compacting concrete watering and curring with cost conveyance royalty and taxes of all materials and all labour with T& P required for the work complete in all respect excluding the cost for centering & shuttering and M.S rod etc. |
| 6 | 12mm thick cement plaster over brick massonary in cm(1:6) |
| 7 | Filling F&P with excavated mateials,moorum including watering and ramming as directed by the Engineer-in-Charge |
| 8 | Cement Punning |
| 9 | Supplying fitting and placing uncoated HYSD bar reinforcement complete |
| 10 | Labour charges for laying and jointing of 160mm daia PVC pipe line including transportation charges to work site |
| 11 | Rigid samooth centering and shuttering for RCC works including false work and dismentalling then after casting including cost of materials complete (i) Walls and fins |
| 12 | ii) Lintel & chaja |
| 13 | iii)Roof |
| 14 | Writing of salient features and project data as per the instruction after 2 coats cement paint washing for base primer |
| 15 | Priming of MS Door |
| 16 | Painting of MS Door2 coat with approved shade of paint |
| 17 | Supplying and fitting of MD double door size 2mt x1mt made up with 18 gauge G.I. sheet with required hinges, W.I.clamps and locking arrangements etc. complete |
| 18 | Lowering of 6HP SU pumpset with requied accessorise labour charges and other mis. Charges |
| 19 | Electrification of pump chamber |
| 20 | 0 mtr. to 50 Mtr |
| 21 | Supply of all labour and T & P for lowering following size G.I./PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position including cutting and threading pipe and slotted pipe and fixing all joint materials, tools and plants etc. complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry to foreign materials from above excluding cost of fittings and jointing materials and packing gravels around the casing in the annular space as per the direction of the Engineer0 Mtr to 50 Mtr |
| 22 | Labour charges for cutting Transverse slot on 200 mm dia PVC pipe with slot size 1.5mm as per specification. charges to work site |
| 23 | Supply of all labour and T & P for packing the bore with washed grvel size (P-6) arround the wall screen and pipes in good quality including cost of gravel, conveyance, royalite etc complete as per direction Engineer-in-charge (500m depth)=0.786x(0.4Q-0.2Q)x50mtr=4.71 say 4.7cum |
| 24 | Cost of 200mm dia PVC bail plug |
| 25 | Cost of 200mm dia PVC threaded end cap PN-10 |
| 26 | Cost of 200mm x 12\" long PVC shot piece |
| 27 | Cleaning and developing the production well using own Air compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of the Engineer-in-Charge. |
| 28 | 200mm dia SCHEDULE 80 casing pipe ( As per EPM Rare order no 4415 dated 25.10.2024) |
| 29 | 6 HP/4.5 KW Energy efficiency submersible pump set of total head 25 mtr having 700 LPM discharge of reputed brand with BEE 3 star rated energy efficiency sutable for 200mm die tube well as per IS specifacation with 2 pair U- clamp & 30 mtr of 4.00 sqmm flat cable and Impeler Bronze grade LTB-2 of IS 318/1981 confirming to IS specifation including all cost , conveyeyance, cess etc. complite but excluding of GST. |
| 30 | Automatic Control Pannel wth sheet steel enclosure suitable for operation of squirrel cage induction motor for 10HP having full load current of 16 Amp at 415V +6%- 15%, 3phase,50Hz, AC supply with over load relay range 7 to 10 Amp and No volt coil suitable for operation at voltage range of 350-440 V. Control pannel with volt meter( 0 to 500V,) Ameter(0.to 30A) and RYB indicator.The control pannel should provide dependable protection against overload and single phasing of reputed brand having wide dealership network for easy availability of spares with ISI mark and guarantee |
| 31 | 3x10 sqmm Trapoder Cable XLPE (Cross link polyethylin) including laying below the ground and filling the excavated materials including watering and ramming with ISI mark and guarantee |
| 32 | 100 mm dia nominal bore G.I.Pipe having wall thichness 4.5mm electrical resistance welded of medium class fonfirming to IS-1239(Part-I/2004) with latest Amendments,screwed at both ends as per IS-554 socketed at one end and the other end protected with plastic threaded protector. The socket confirming to IS1239(Part-II/1992) with latest Amendments in random length of 4 to 7mtrs. Each pipe should bear ISI Certification and manufacturers name/trademark, for fitting in suction and delivery pipes. |
| 33 | 100mm dia G.I. flange IS No.6392/1971 |
| 34 | 100mm dia G.I. bend IS No.1239 (Part-II/1992) |
| 35 | Unplasticised rigid UPVC ivory gray in colour having specific gravity at 1.4 to 1.46 gms/cc of straight length of 6 (six) meter for portable water supplies confirming to IS-4985/2000 of BIS- Amendment-2 read with Table-1 of IS- specification bearing ISI marks for working pressure CL-II UPVC pipe to withstand pressure of 2.5 Kgf/sqcm and the specification and manufacturer name should be prominently marked on body of each pipe as per the latest Amendment of IS-4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be conducted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar/EPM, Orissa.Bhubaneswar for necessary approval of authority including transportation and laying at site all complete. (i) 160mm dia P.V.C.Pipe |
| 36 | 100mm dia G.I.socket |
| 37 | Main Switch 63 Amp including fitting and fixing as per IS No.4064(Part-I & II) with utilisation capacity category AC-22 |
| 38 | Cost of 200mm dia MS pipe |
| 39 | Cost of 160 x 160 x 110mm G.I raiser tee including closing & opening arrangement in complete |
| 40 | 160mm PVC end cap (6kgf/cm2) confirming to PL-R PVC -IS 2000F |
| 41 | 110 mm dia PVC FTA (6kg/cm2) confirming to IS 4985/2000 |
| 42 | 160x110mm dia PVC Reducting Socket confirming to IS 4985/2000 |
| 43 | 4KVAR Capacitor |
| 44 | 50mm dia CI A.R.release value( single action) confirming to IS 14845 (SI) |
| 45 | 100mm dia Sluice valve. Valve confirming to IS-5312(Pt.I) with ISI mark,GM fitting S/S hinge pin without by pass |
| 46 | 100mm dia M.S.clamp |
| 47 | Solvent Cement |
| 48 | 160x160x160mm dia PVC equal Tee (6kgf/cm2) confirming to PL-R PVC -IS 2000F |
| 49 | U clamp for wire rope ( 5 piece in 1 set) |
| 50 | Stainless steel nut & bolt |
| 51 | 12mm dia PVC cover steel wire rope |
| 52 | Post test of PVC Pipe |
| 53 | DE Spanner-1set & Hand Gloves-1Pair |
| 54 | SCHEDULE-B Installation of 25 KVA, 11/0.4 KV pole mounted Sub-station using 10 mtr. Long PSC pole with *** star rated transformer as per the specification and estimate of DISTCOM. |
| 55 | Construction of 11KV line 3 phase 3 wire with 10 mtr. Long 300 kg. PSC pole using 55sq. Mm AAA conductor 60 mtr. Span with all materials required for the same as per the specification & estimate of DISTCOM. |
| 56 | Construction of 180 degree cutpoint angle with 10mtr PSC polewith required materials like Disc insulater,pin insulater ,Polymer,angles & cross arm etc as per specification & estimate of TPCODL |
| 57 | 11 KVA line protecting Guarding for Road crossing/ River crossing as per estimateof TPCODL |
| 58 | Electrical installation with electrical materials such as PVC tape, ampere tape, 7/20 PVC copper wire, 3/20 PVC copper wire, G.I. flexible conduit pipe, no. 6 G.I. wire, copper cable socket, G.I. socket and flange and petty materials required for electrical installation. All materials should be as per IS. |
| 59 | Electrical earthing including all materials as per the direction of Engineer-in-charge Please Enable Macros to View BoQ information |