| 1 | SCHEDULE-A(NARADA-II) Earth work excavation of foundation in hard soil within 50m initial lead and 1.5m lift |
| 2 | Filling F &P with sand well watered and rammed |
| 3 | CC(1:4:8) using 4 cm size h.g.crusher broken metal |
| 4 | Fly ash.Brick work in CM(1:6) in (25cm x12 cm x8cm) having crushing strength not less than 75kg/cm2 with dimensional tolerance +8% in F& P |
| 5 | RCC (1:2:4) using 12mm size c.b.h.g.chips including hosting and lowering,laying and compacting concrete watering and curring with cost conveyance royalty and taxes of all materials and all labour with T& P required for the work complete in all respect excluding the cost for centering & shuttering and M.S rod etc. |
| 6 | 12mm thick cement plaster over brick massonary in cm(1:6) |
| 7 | Filling F&P with excavated mateials,moorum including watering and ramming as directed by the Engineer-in-Charge |
| 8 | Cement Punning |
| 9 | Supplying fitting and placing uncoated HYSD bar reinforcement complete |
| 10 | Labour charges for laying and jointing of 160mm daia PVC pipe line including transportation charges to work site |
| 11 | Rigid samooth centering and shuttering for RCC works including false work and dismentalling then after casting including cost of materials complete (i) Walls and fins |
| 12 | ii) Lintel & chaja |
| 13 | iii)Roof |
| 14 | Writing of salient features and project data as per the instruction after 2 coats cement paint washing for base primer |
| 15 | Priming of MS Door |
| 16 | Painting of MS Door2 coat with approved shade of paint |
| 17 | Supplying and fitting of MD double door size 2mt x1mt made up with 18 gauge G.I. sheet with required hinges, W.I.clamps and locking arrangements etc. complete |
| 18 | Electrification of pump chamber |
| 19 | Lowering of 6HP SU pumpset with requied accessorise labour charges and other mis. Charges |
| 20 | 6 HP/4.5 KW Energy efficiency submersible pump set of total head 25 mtr having 700 LPM discharge of reputed brand with BEE 3 star rated energy efficiency sutable for 200mm die tube well as per IS specifacation with 2 pair U- clamp & 30 mtr of 4.00 sqmm flat cable and Impeler Bronze grade LTB-2 of IS 318/1981 confirming to IS specifation including all cost , conveyeyance, cess etc. complite but excluding of GST. |
| 21 | Automatic Control Pannel wth sheet steel enclosure suitable for operation of squirrel cage induction motor for 10HP having full load current of 16 Amp at 415V +6%- 15%, 3phase,50Hz, AC supply with over load relay range 7 to 10 Amp and No volt coil suitable for operation at voltage range of 350-440 V. Control pannel with volt meter( 0 to 500V,) Ameter(0.to 30A) and RYB indicator.The control pannel should provide dependable protection against overload and single phasing of reputed brand having wide dealership network for easy availability of spares with ISI mark and guarantee |
| 22 | 3x10 sqmm Trapoder Cable XLPE (Cross link polyethylin) including laying below the ground and filling the excavated materials including watering and ramming with ISI mark and guarantee |
| 23 | 100 mm dia nominal bore G.I.Pipe having wall thichness 4.5mm electrical resistance welded of medium class fonfirming to IS-1239(Part-I/2004) with latest Amendments,screwed at both ends as per IS-554 socketed at one end and the other end protected with plastic threaded protector. The socket confirming to IS1239(Part-II/1992) with latest Amendments in random length of 4 to 7mtrs. Each pipe should bear ISI Certification and manufacturers name/trademark, for fitting in suction and delivery pipes. |
| 24 | 100mm dia G.I. flange IS No.6392/1971 |
| 25 | 100mm dia G.I. bend IS No.1239 (Part-II/1992) |
| 26 | Unplasticised rigid UPVC ivory gray in colour having specific gravity at 1.4 to 1.46 gms/cc of straight length of 6 (six) meter for portable water supplies confirming to IS-4985/2000 of BIS- Amendment-2 read with Table-1 of IS- specification bearing ISI marks for working pressure CL-II UPVC pipe to withstand pressure of 2.5 Kgf/sqcm and the specification and manufacturer name should be prominently marked on body of each pipe as per the latest Amendment of IS-4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be conducted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar/EPM, Orissa.Bhubaneswar for necessary approval of authority including transportation and laying at site all complete. (i) 160mm dia P.V.C.Pipe |
| 27 | 100mm dia G.I.socket |
| 28 | Main Switch 63 Amp including fitting and fixing as per IS No.4064(Part-I & II) with utilisation capacity category AC-22 |
| 29 | Cost of 160 x 160 x 110mm G.I raiser tee including closing & opening arrangement in complete |
| 30 | 160mm PVC end cap (6kgf/cm2) confirming to PL-R PVC -IS 2000F |
| 31 | 4KVAR Capacitor |
| 32 | 50mm dia CI A.R.release value( single action) confirming to IS 14845 (SI) |
| 33 | 100mm dia Sluice valve. Valve confirming to IS-5312(Pt.I) with ISI mark,GM fitting S/S hinge pin without by pass |
| 34 | 100mm dia M.S.clamp |
| 35 | Solvent Cement |
| 36 | 160x160x160mm dia PVC equal Tee (6kgf/cm2) confirming to PL-R PVC -IS 2000F |
| 37 | U clamp for wire rope ( 5 piece in 1 set) |
| 38 | Stainless steel nut & bolt |
| 39 | 12mm dia PVC cover steel wire rope |
| 40 | Post test of PVC Pipe |
| 41 | DE Spanner-1set & Hand Gloves-1Pair |
| 42 | SCHEDULE-B(NARADA-II) Electrical installation with electrical materials such as PVC tape, ampere tape, 7/20 PVC copper wire, 3/20 PVC copper wire, G.I. flexible conduit pipe, no. 6 G.I. wire, copper cable socket, G.I. socket and flange and petty materials required for electrical installation. All materials should be as per IS. |
| 43 | Electrical earthing including all materials as per the direction of Engineer-in-charge |
| 44 | SCHEDULE-A(JAYATALANGA-II) Earth work excavation of foundation in hard soil within 50m initial lead and 1.5m lift |
| 45 | Filling F &P with sand well watered and rammed |
| 46 | CC(1:4:8) using 4 cm size h.g.crusher broken metal |
| 47 | Fly ash.Brick work in CM(1:6) in (25cm x12 cm x8cm) having crushing strength not less than 75kg/cm2 with dimensional tolerance +8% in F& P |
| 48 | RCC (1:2:4) using 12mm size c.b.h.g.chips including hosting and lowering,laying and compacting concrete watering and curring with cost conveyance royalty and taxes of all materials and all labour with T& P required for the work complete in all respect excluding the cost for centering & shuttering and M.S rod etc. |
| 49 | 12mm thick cement plaster over brick massonary in cm(1:6) |
| 50 | Filling F&P with excavated mateials,moorum including watering and ramming as directed by the Engineer-in-Charge |
| 51 | Cement Punning |
| 52 | Supplying fitting and placing uncoated HYSD bar reinforcement complete |
| 53 | Labour charges for laying and jointing of 160mm daia PVC pipe line including transportation charges to work site |
| 54 | Rigid samooth centering and shuttering for RCC works including false work and dismentalling then after casting including cost of materials complete (i) Walls and fins |
| 55 | Writing of salient features and project data as per the instruction after 2 coats cement paint washing for base primer |
| 56 | Lowering of 6HP SU pumpset with requied accessorise labour charges and other mis. Charges |
| 57 | 6 HP/4.5 KW Energy efficiency submersible pump set of total head 25 mtr having 700 LPM discharge of reputed brand with BEE 3 star rated energy efficiency sutable for 200mm die tube well as per IS specifacation with 2 pair U- clamp & 30 mtr of 4.00 sqmm flat cable and Impeler Bronze grade LTB-2 of IS 318/1981 confirming to IS specifation including all cost , conveyeyance, cess etc. complite but excluding of GST. |
| 58 | Automatic Control Pannel wth sheet steel enclosure suitable for operation of squirrel cage induction motor for 10HP having full load current of 16 Amp at 415V +6%- 15%, 3phase,50Hz, AC supply with over load relay range 7 to 10 Amp and No volt coil suitable for operation at voltage range of 350-440 V. Control pannel with volt meter( 0 to 500V,) Ameter(0.to 30A) and RYB indicator.The control pannel should provide dependable protection against overload and single phasing of reputed brand having wide dealership network for easy availability of spares with ISI mark and guarantee |
| 59 | 3x10 sqmm Trapoder Cable XLPE (Cross link polyethylin) including laying below the ground and filling the excavated materials including watering and ramming with ISI mark and guarantee |
| 60 | 100 mm dia nominal bore G.I.Pipe having wall thichness 4.5mm electrical resistance welded of medium class fonfirming to IS-1239(Part-I/2004) with latest Amendments,screwed at both ends as per IS-554 socketed at one end and the other end protected with plastic threaded protector. The socket confirming to IS1239(Part-II/1992) with latest Amendments in random length of 4 to 7mtrs. Each pipe should bear ISI Certification and manufacturers name/trademark, for fitting in suction and delivery pipes. |
| 61 | 100mm dia G.I. flange IS No.6392/1971 |
| 62 | 100mm dia G.I. bend IS No.1239 (Part-II/1992) |
| 63 | Unplasticised rigid UPVC ivory gray in colour having specific gravity at 1.4 to 1.46 gms/cc of straight length of 6 (six) meter for portable water supplies confirming to IS-4985/2000 of BIS- Amendment-2 read with Table-1 of IS- specification bearing ISI marks for working pressure CL-II UPVC pipe to withstand pressure of 2.5 Kgf/sqcm and the specification and manufacturer name should be prominently marked on body of each pipe as per the latest Amendment of IS-4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be conducted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar/EPM, Orissa.Bhubaneswar for necessary approval of authority including transportation and laying at site all complete. (i) 160mm dia P.V.C.Pipe |
| 64 | 100mm dia G.I.socket |
| 65 | Main Switch 63 Amp including fitting and fixing as per IS No.4064(Part-I & II) with utilisation capacity category AC-22 |
| 66 | Cost of 160 x 160 x 110mm G.I raiser tee including closing & opening arrangement in complete |
| 67 | 160mm PVC end cap (6kgf/cm2) confirming to PL-R PVC -IS 2000F |
| 68 | 4KVAR Capacitor |
| 69 | 50mm dia CI A.R.release value( single action) confirming to IS 14845 (SI) |
| 70 | 100mm dia Sluice valve. Valve confirming to IS-5312(Pt.I) with ISI mark,GM fitting S/S hinge pin without by pass |
| 71 | 100mm dia M.S.clamp |
| 72 | Solvent Cement |
| 73 | 160x160x160mm dia PVC equal Tee (6kgf/cm2) confirming to PL-R PVC -IS 2000F |
| 74 | U clamp for wire rope ( 5 piece in 1 set) |
| 75 | Stainless steel nut & bolt |
| 76 | 12mm dia PVC cover steel wire rope |
| 77 | Post test of PVC Pipe |
| 78 | DE Spanner-1set & Hand Gloves-1Pair |
| 79 | SCHEDULE-B(JAYATALANGA-ii) Electrical installation with electrical materials such as PVC tape, ampere tape, 7/20 PVC copper wire, 3/20 PVC copper wire, G.I. flexible conduit pipe, no. 6 G.I. wire, copper cable socket, G.I. socket and flange and petty materials required for electrical installation. All materials should be as per IS. |
| 80 | Electrical earthing including all materials as per the direction of Engineer-in-charge |
| 81 | SCHEDULE-A(BHADILO) Earth work excavation of foundation in hard soil within 50m initial lead and 1.5m lift |
| 82 | Filling F &P with sand well watered and rammed |
| 83 | CC(1:4:8) using 4 cm size h.g.crusher broken metal |
| 84 | Fly ash.Brick work in CM(1:6) in (25cm x12 cm x8cm) having crushing strength not less than 75kg/cm2 with dimensional tolerance +8% in F& P |
| 85 | RCC (1:2:4) using 12mm size c.b.h.g.chips including hosting and lowering,laying and compacting concrete watering and curring with cost conveyance royalty and taxes of all materials and all labour with T& P required for the work complete in all respect excluding the cost for centering & shuttering and M.S rod etc. |
| 86 | 12mm thick cement plaster over brick massonary in cm(1:6) |
| 87 | Filling F&P with excavated mateials,moorum including watering and ramming as directed by the Engineer-in-Charge |
| 88 | Cement Punning |
| 89 | Supplying fitting and placing uncoated HYSD bar reinforcement complete |
| 90 | Writing of salient features and project data as per the instruction after 2 coats cement paint washing for base primer |
| 91 | Lowering of 6HP SU pumpset with requied accessorise labour charges and other mis. Charges |
| 92 | 100 mm dia nominal bore G.I.Pipe having wall thichness 4.5mm electrical resistance welded of medium class fonfirming to IS-1239(Part-I/2004) with latest Amendments,screwed at both ends as per IS-554 socketed at one end and the other end protected with plastic threaded protector. The socket confirming to IS1239(Part-II/1992) with latest Amendments in random length of 4 to 7mtrs. Each pipe should bear ISI Certification and manufacturers name/trademark, for fitting in suction and delivery pipes. |
| 93 | 100mm dia G.I. flange IS No.6392/1971 |
| 94 | 100mm dia G.I. bend IS No.1239 (Part-II/1992) |
| 95 | 50mm dia CI A.R.release value( single action) confirming to IS 14845 (SI) |
| 96 | DE Spanner-1set & Hand Gloves-1Pair |
| 97 | SCHEDULE-B(BHADILO) Construction of 3 phase 11KV line as per REC standard confirming to RE Rules 1956 with 300 kg 9mtr long PSC pole support in 60M span, with interposing of 300kg 9mtr long PSC pole-1no, 55 Sqmm AAA Conductor,11 KV \"V\" Cross arm,with required No.of 11 KV T& C Disc.Insulators & 11 KV Pin insulators,Couping & Padding of Poles. Danger Board at each Pole,Anti Climbing Devices,Stay Set at Bending point & double stay at end point with 18mm G.I.H.T. Stay, concerting of Pole & Stay with Anchor plate,guarding at Road Crossing etc. including cost of all materials,labour transportation, errection,inspection & commissioning etc. complete as per direction of Engineer-in -Charge |
| 98 | Construction and erection of 11/0.4KV ,25KVA D.P. Substation confirming RERules1956,mounted on 2.80mtr Long channel2nos,supported in 300 Kg 9mtr long PSC pole 2nos alongwith AB switch, HG fusemountingchannel, cantiliver channel, Tranaformer belting with 2.80mtr long angle 2nos,insulator, hard wire fitting, lightning arrestor-3nos , stay accessories danger board, provision for anti climbing devices to D.P. ,LT distribution box with kit kat fuse with MCCB 25 KVA *** rated tansformer ,35mm2 x3 1/2 core PVC cable and other materials required ,earthing with G.I. pipe , G.I. wire and G.I. flat and other materials like nut bolt, washer etc.,socket with concreting of poles and stay including barbed wire fencing(size 15\" x10\"),construction of retaining wall, errection of RCC fencing post, Sand filling and metal spreading around the S/S ,fixing of iron gate etc. including cost of all materials, labour, transportation ,errection, testing and commissioning & inspection etc. as per direction of Engineer-in -charge |
| 99 | Electrical installation with electrical materials such as PVC tape, ampere tape, 7/20 PVC copper wire, 3/20 PVC copper wire, G.I. flexible conduit pipe, no. 6 G.I. wire, copper cable socket, G.I. socket and flange and petty materials required for electrical installation. All materials should be as per IS. |
| 100 | Electrical earthing including all materials as per the direction of Engineer-in-charge |
| 101 | SCHEDULE-A(BANAKUNDA) Earth work excavation of foundation in hard soil within 50m initial lead and 1.5m lift |
| 102 | Filling F &P with sand well watered and rammed |
| 103 | CC(1:4:8) using 4 cm size h.g.crusher broken metal |
| 104 | Fly ash.Brick work in CM(1:6) in (25cm x12 cm x8cm) having crushing strength not less than 75kg/cm2 with dimensional tolerance +8% in F& P |
| 105 | RCC (1:2:4) using 12mm size c.b.h.g.chips including hosting and lowering,laying and compacting concrete watering and curring with cost conveyance royalty and taxes of all materials and all labour with T& P required for the work complete in all respect excluding the cost for centering & shuttering and M.S rod etc. |
| 106 | 12mm thick cement plaster over brick massonary in cm(1:6) |
| 107 | Filling F&P with excavated mateials,moorum including watering and ramming as directed by the Engineer-in-Charge |
| 108 | Cement Punning |
| 109 | Supplying fitting and placing uncoated HYSD bar reinforcement complete |
| 110 | Labour charges for laying and jointing of 160mm daia PVC pipe line including transportation charges to work site |
| 111 | Rigid samooth centering and shuttering for RCC works including false work and dismentalling then after casting including cost of materials complete (i) Walls and fins |
| 112 | ii) Lintel & chaja |
| 113 | iii)Roof |
| 114 | Writing of salient features and project data as per the instruction after 2 coats cement paint washing for base primer |
| 115 | Priming of MS Door |
| 116 | Painting of MS Door2 coat with approved shade of paint |
| 117 | Supplying and fitting of MD double door size 2mt x1mt made up with 18 gauge G.I. sheet with required hinges, W.I.clamps and locking arrangements etc. complete |
| 118 | Electrification of pump chamber |
| 119 | Lowering of 6HP SU pumpset with requied accessorise labour charges and other mis. Charges |
| 120 | 6 HP/4.5 KW Energy efficiency submersible pump set of total head 25 mtr having 700 LPM discharge of reputed brand with BEE 3 star rated energy efficiency sutable for 200mm die tube well as per IS specifacation with 2 pair U- clamp & 30 mtr of 4.00 sqmm flat cable and Impeler Bronze grade LTB-2 of IS 318/1981 confirming to IS specifation including all cost , conveyeyance, cess etc. complite but excluding of GST. |
| 121 | Automatic Control Pannel wth sheet steel enclosure suitable for operation of squirrel cage induction motor for 10HP having full load current of 16 Amp at 415V +6%- 15%, 3phase,50Hz, AC supply with over load relay range 7 to 10 Amp and No volt coil suitable for operation at voltage range of 350-440 V. Control pannel with volt meter( 0 to 500V,) Ameter(0.to 30A) and RYB indicator.The control pannel should provide dependable protection against overload and single phasing of reputed brand having wide dealership network for easy availability of spares with ISI mark and guarantee |
| 122 | 3x10 sqmm Trapoder Cable XLPE (Cross link polyethylin) including laying below the ground and filling the excavated materials including watering and ramming with ISI mark and guarantee |
| 123 | 100 mm dia nominal bore G.I.Pipe having wall thichness 4.5mm electrical resistance welded of medium class fonfirming to IS-1239(Part-I/2004) with latest Amendments,screwed at both ends as per IS-554 socketed at one end and the other end protected with plastic threaded protector. The socket confirming to IS1239(Part-II/1992) with latest Amendments in random length of 4 to 7mtrs. Each pipe should bear ISI Certification and manufacturers name/trademark, for fitting in suction and delivery pipes. |
| 124 | 100mm dia G.I. flange IS No.6392/1971 |
| 125 | 100mm dia G.I. bend IS No.1239 (Part-II/1992) |
| 126 | Unplasticised rigid UPVC ivory gray in colour having specific gravity at 1.4 to 1.46 gms/cc of straight length of 6 (six) meter for portable water supplies confirming to IS-4985/2000 of BIS- Amendment-2 read with Table-1 of IS- specification bearing ISI marks for working pressure CL-II UPVC pipe to withstand pressure of 2.5 Kgf/sqcm and the specification and manufacturer name should be prominently marked on body of each pipe as per the latest Amendment of IS-4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be conducted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar/EPM, Orissa.Bhubaneswar for necessary approval of authority including transportation and laying at site all complete. (i) 160mm dia P.V.C.Pipe |
| 127 | 100mm dia G.I.socket |
| 128 | Main Switch 63 Amp including fitting and fixing as per IS No.4064(Part-I & II) with utilisation capacity category AC-22 |
| 129 | Cost of 160 x 160 x 110mm G.I raiser tee including closing & opening arrangement in complete |
| 130 | 160mm PVC end cap (6kgf/cm2) confirming to PL-R PVC -IS 2000F |
| 131 | 4KVAR Capacitor |
| 132 | 50mm dia CI A.R.release value( single action) confirming to IS 14845 (SI) |
| 133 | 100mm dia Sluice valve. Valve confirming to IS-5312(Pt.I) with ISI mark,GM fitting S/S hinge pin without by pass |
| 134 | 100mm dia M.S.clamp |
| 135 | Solvent Cement |
| 136 | 160x160x160mm dia PVC equal Tee (6kgf/cm2) confirming to PL-R PVC -IS 2000F |
| 137 | U clamp for wire rope ( 5 piece in 1 set) |
| 138 | Stainless steel nut & bolt |
| 139 | 12mm dia PVC cover steel wire rope |
| 140 | Post test of PVC Pipe |
| 141 | DE Spanner-1set & Hand Gloves-1Pair |
| 142 | SCHEDULE-B(BANAKUNDA) Electrical installation with electrical materials such as PVC tape, ampere tape, 7/20 PVC copper wire, 3/20 PVC copper wire, G.I. flexible conduit pipe, no. 6 G.I. wire, copper cable socket, G.I. socket and flange and petty materials required for electrical installation. All materials should be as per IS. |
| 143 | Electrical earthing including all materials as per the direction of Engineer-in-charge Please Enable Macros to View BoQ information |