| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 5 | a)1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 6 | b) 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 9 | a)Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 10 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 11 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 12 | Cement mortar 1:3 (1 cement :3 coarse sand) |
| 13 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.ird course of half brick masonry. |
| 14 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer-in-Charge. |
| 15 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. |
| 16 | 30 mm thick plain PVC door shutters. |
| 17 | Providing and laying Ceramic glazed floor tiles (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete. |
| 18 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing the joints with white cement mixed with pigment of matching shade complete. |
| 19 | Providing and fixing PVC flooring sheets in flooring and skirting in approved pattern on a smooth and damp proof base using rubber based adhessives of approved quality and manufacture like Dunlop S - 758 , Fevicol SR 998 or equivalent , copper strip and other materials required at site including rolling with light wooden roller weighing about 5 Kg all complete as directed by the Engineer - in - charge in approved colour and shade (1 mm thick). (The rate includes the cost of materials , labour other materials required and transportation to various locations etc. complete.) |
| 20 | 12 mm cement plaster of mix : |
| 21 | a)1:6 (1 cement: 6 fine sand) |
| 22 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 23 | a)1:6 (1 cement: 6 fine sand) |
| 24 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
| 25 | a)Two coats. |
| 26 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 27 | a) With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. |
| 28 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 29 | Fixing available aluminium work forpartitions doors with available tubular sections/appropriate Z sections and other sectionsfixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,providing newAluminium snap beading wherever necessary for fixing available glazing / available paneling, new C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge |
| 30 | Laying available false ceiling tilesin position in the existing false ceiling grid including necessary cutting etc complete as per the direction of Engineer in charge. |
| 31 | Carefully Dismantling the existing transaction counter of dimension4500X600X750mm alongwith 3 Nos side tableof size 750X600X750mm with granite top and SS tube,8mm glass protective measures etc from its current position, transportation to the site and relocating in the ground floor of TE building as per the approved layout plan and as per the instructions of Engineer in charge. |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 33 | One or more coats on old work. |
| 34 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge. |
| 35 | With cement mortar 1:4 (1cement: 4 coarse sand). |
| 36 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 37 | a)Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 38 | b) Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 39 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 40 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. |
| 41 | In cement mortar |
| 42 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 43 | Of area 3 sq. metres and below |
| 44 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 45 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : |
| 46 | W.C. pan with ISI marked white solid plastic seat and lid |
| 47 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 48 | White Vitreous China Wash basin size 550x400 mm with a single 15 mm C.P. brass pillar tap |
| 49 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 50 | Flexible pipe32 mm dia |
| 51 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 52 | Rectangular shape 453x357 mm |
| 53 | Providing and fixing rigid unplasticised PVC pipe (pressure class of 10Kg/Sq.cm) complete with fittings and clamps, including cutting and making good the walls etc. (internal work) conforming to IS 4985-1988 Exposed on wall |
| 54 | a)20 mm nominal outer dia .Pipes. |
| 55 | a)25 mm nominal outer dia .Pipes. |
| 56 | Providing and fixing UPVC plastic ball valve of approved brand andquality etc complete as per the direction of Engineer in Charge. |
| 57 | 20 mm nominal bore |
| 58 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 59 | 30 cm length 15 mm nominal bore |
| 60 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 61 | 15 mm nominal bore |
| 62 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 63 | 15 mm nominal bore. |
| 64 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : |
| 65 | 15mm nominal bore |
| 66 | Providing and fixing CP Brass towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 67 | 600 mm long towel rail with 20mmdia |
| 68 | Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements. Weighing not less than 106 gms. |
| 69 | Providing and Fixing PVC Floor trap ( including Grating ) of self cleansing design including jointing with PVC Pipes etc. complete |
| 70 | PVC Floor trap 100x75mm |
| 71 | Providing and fixing unplasticisedPVCwaste water pipes of pressure class 4Kg/ Sqcm conforming to IS: 13592 including jointing with solvent cement solution . |
| 72 | a)110mm dia |
| 73 | b) 75mm dia |
| 74 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 75 | i)Bend 87.5°(a)75 mm bend |
| 76 | b) 110 mm bend |
| 77 | ii)Door Bend a) 110 mm Doorbend |
| 78 | b) 75 mmDoor bend bend |
| 79 | Providing and fixing PTMT grating of approved quality and colour. |
| 80 | Circular type.100 mm nominal dia. |
| 81 | Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 82 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 83 | Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer -in-charge. |
| 84 | Providingand fixing PVC inspection chambers100mm including covers of approved design and manufacture including fixing in position in required level and necessary cement concrete 1:2:4 alround etc as per the direction of Engineer in charge.{The rate included all cost of labour for fixing in level and excluding cost of cement concrete etc complete] |
| 85 | Providingand fixing PVC risers forinspection chambers100mm including fixing in position etc as per the direction of Engineer in charge.{The rate included all cost of labour for fixing in level and excluding cost of cement concrete etc complete] |
| 86 | Filling the soakpit with brick bats including all labour charges etc complete as per the direction of Engineer in Charge. |
| 87 | Credit for takingpossession and disposal of unservicable materials |
| 88 | a) scrap steel reinforcement, angles, M.S.pipes etc (Credit item) |
| 89 | b) Flush door shutter with frames (Credit item) |