| 1 | R.C.C. work M-20 grade using 20mm.and down grade HBG crusher broken chips including hoisting,laying, cost,conveyance and royality of materials curing including centering and shuttering etc. complete as per direction of Engg-in-Charge . |
| 2 | PRECAST SLAB |
| 3 | CHAJJA |
| 4 | column |
| 5 | Supplying,fitting and placing uncoated HYSD bar reinforcement as per drawing and technical specification including cost,conveyance and all taxes of steel and binding wire etc.complete as per direction of Engg-in-Charge . |
| 6 | Brick work with Fly Ash .Bricks having crushing strength between 100kg/sq.cm to 149kg/sq.cm in c.m. 1:6 in Sup.Str. including cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge . |
| 7 | Ground floor |
| 8 | First floor |
| 9 | Removing old lime or cement plaster form walls including raking out joints 12mm deep and removing the debris within 50 m lead |
| 10 | 12mm. thick cement plaster in c.m. 1:6 over brick masonry including cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge . |
| 11 | Enamel Painting two coats with enamel paint over one coat of primer of approved quality etc. complete as per direction of Engg-in-Charge . |
| 12 | Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T & P etc. complete as per direction of Engg-in-Charge . |
| 13 | Wall painting with premium acrylic emulsion paint of grade having VOC (volatile organic compound content less than 50 gm/ltr of approved brand and manufacture,including applying additional coats whrerever required to achieve even shade and colour )inside wall |
| 14 | Finishing walls with textured exterior paint of required shade |
| 15 | Ground floor |
| 16 | First floor |
| 17 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/ litre |
| 18 | Distempering two coats to walls with distemper of approved shade to give an shade excluding cost of distemper. |
| 19 | Dismantling Brick / Tile work in cement mortar including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres |
| 20 | Fixing granite tiles of 0.10 Sqm. & upto 0.4 Sqm. (10mm. thick) in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades includind cost for rubbing, poloshing complete excluding cost of tiles etc. complete as per direction of Engg-in-Charge . |
| 21 | Fixing colour Vitrified tiles in floors (Printed Series) of size 600mm x600 mm of approved make conforming IS:13755 laid on 20 mm thick cement mortar (1:1)and filling joints with white cement of approved quality including cost of all materials, labour T&P etc rrequired for the work all completeas per direction of Engineer-in-charge. |
| 22 | Ground floor |
| 23 | First floor |
| 24 | Fixing Ceramic Glazed wall tiles in dados skirting and risers of stepson 12 mm thick cement plaster(1:3) jointed with neat cement slurry mixed with pigments to matche shade of the tiles including rubbing and polishing complete as per direction of Engineer-in-charge. |
| 25 | Fixing of ceramic tiles in floors, treads or steps and landing of steps on 25mm thick cement plaster in mortar (1:1) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles per 1 sqm |
| 26 | First floor |
| 27 | Dismantling of Lime Concrete, cement concrete grade M-10 and below including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres etc. complete as per direction of Engg-in-Charge . |
| 28 | Supplying , fitting and fixing of two track UPVC sliding windowof approved make with 6mm thick glass of approved qualitycomplete with frame, shutters and all fitting and fixtures. |
| 29 | Supplying , fitting and fixing of openable UPVC doors with doorframe of approved make with 6mm thick glass of approved qualitycomplete with frame, shutters and all fitting and fixtures |
| 30 | 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete including Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement , including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer’s specification and direction of Engineer-in-charge. |
| 31 | Door shutter |
| 32 | door frame |
| 33 | Iron work wrought and put up in trusses and record racks |
| 34 | Supply fitting and fixing of 0.40mm GCI. Sheet in in roof drilling hole in wind ties including fixing of ridges valleys wind ties etc. including cost of fitting as per direction of Engineer-incharge. |
| 35 | Ground floor |
| 36 | First floor |
| 37 | Supply fitting and fixing MS grill with Iron work wrought and put up in window grating including drilling holes in choukathas etc. complete as per direction of Engg-in-Charge . |
| 38 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers,handles, including applying a priming coat of approved steel primer.handles, including applying a priming coat of approved steel primer. |
| 39 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. |
| 40 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 41 | Providing fitting and fixing of False ceiling with Aluminium anodised T section No. 3215 with 2\".0\"\" center ,L section no. 1705 upto 15 micron on walls to be fixed by means of steel crew and PVC plug and the Aluminium grid 2\".0\"\" X2\"-0\"\" suspended from ceiling etc complete. (WITH GYPSU BOARD) |
| 42 | Providing and fixing 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge |
| 43 | Fixing 600mm x 600mmbathroom mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with chromium plated brass screws and washers complete as ner specification. |
| 44 | Fixing 100mm size \"P\" or \"S\" trap (with horn or without horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1) as per specification. |
| 45 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 46 | Fixing of CP Shower with Arm of following nominal sizes as per specification complete. |
| 47 | Fixing wash basins with hole for pillar taps confirming to IS 2556: Part 4-2004 with Cast Iron or M.S. brackets painted white including cutting holes in walls and making good the damages etc. all complete as per specification including CP waste, Waste Pipe & 15mm dia connection pipe. |
| 48 | Fixing of Brass Screw-down Bib Cocks (Taps) polished bright conforming to IS:781-1995 of the following nominal sizes as per specification complete. |
| 49 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. |
| 50 | Double Layer Rotational Moulded Cylinderical Vertical water storage tanks (ISI marked) |
| 51 | Dismantling squatting type water closet and urinal plates etc and mending good the damages to the floors etc. |
| 52 | Fixing glazed earthenware l squatting urinal plate of size 600mm x 355mm conforming to IS:2556- Part-6-1995 with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:4:8) using 40mm hard granite metal all complete as per specification. |
| 53 | Porcelain Squatting Urinal (600x355mm) |
| 54 | Porcelain Flat back standing Urinal (Medium)380 x 580 x 350 |
| 55 | Fixing water closet, squatting pan (Indian type W.C pan) conforming to IS 2556 : Part- 3 2004 duly embedded in cement concrete (1:4:8) using hard granite metal 4cm nominal size all complete as per specification. |
| 56 | Providing and fixing on wall face unplasticised-Rigid PVC soil, waste & rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion..Single socketed pipe |
| 57 | 110MM DIA |
| 58 | 75MM DIA |
| 59 | Providing and fixing to wall or ceiling and floor C-PVC pipes and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification complete. |
| 60 | 50mm diameter |
| 61 | 32mm diameter |
| 62 | 75 mm diaP.V.C. SWR. pipe clip |
| 63 | 110mm diaP.V.C. SWR.pipe clip |
| 64 | Cleaning and develping the production well using their own compressor contineously worked till clear and adequate discharge is obtained from the tube well including supply and use of all equipments and labour as per the direction of the Engineer-in-Charge |
| 65 | Supply of all labour & T&P for lowering the following size GI/PVC pipes with or without slotted pipes as per necesity from ground level and fitted and fixed up in perfectly vertical position, including cutting and threading pipe and slotted pipe and fixing all jointing materials etc complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials from above excluding cost of fitting and jointing materials. |
| 66 | Supply,Installation,testing and commissioning 18 w LED Light etc directly in ceiling / wall,including connection with 1.5 sqmm FR PVC insulated copper conductor and earthing as required as per direction of engineer in charge.( make of wire Finolex/ L & T /Anchor/Havels/V Guard. |
| 67 | Installation,TestingandCommissioning of ceiling fan, includingwiringthedownrodsof standard length (upto30cm)with1.5sq.mmFRPVC insulatedsinglecoremultiatrandcopper conductor including providing and fixing phenolic laminated sheet steet cover on the fan box etc as required.etc. as required.( make of wire Finolex/ L & T /Anchor/Havels/V Guard. |
| 68 | Recessed wiring to submain with 2 x 2.5 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC flexible conduit along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required as per direction of Engineer in charge Make of wire Finolex/ L & T /Anchor/Havels/V Guard |
| 69 | Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/L&T/Anchor/Havels/V Guard) |
| 70 | Supplying and fixing of 16 / 18 SWG metal box of following sizes (nominal size) on surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required |
| 71 | 200mmx150mmx60mmdeep M.S. box |
| 72 | 75mmx 75mmx 60mmdeep M.S. box |
| 73 | S/F of 10Watt LED Bulb ( Make -Crompton/ Havells/ HPL /Philips/Polycab) |
| 74 | Supplying and fixing batten holder / BK angle holder ISI marked including connection etc. as required. |
| 75 | Supplying and fixing of following piano type switch / socket on the existing switch box / cover |
| 76 | 5/6 AMP Switch |
| 77 | 5 pin 5/6 amp socket |
| 78 | Supply of ceiling fan( make-crompton) Please Enable Macros to View BoQ information |