| 1 | M&L for surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out andsurface dressing soft and loose as specified and as directed. |
| 2 | Excavation in trenches n.exc 1.5m deep and n.exc 1.5m wide and n exc 1.5m in depth. For foundation, etc or for shafts, wells, cesspits, manholes, pierholes, etc n.exc 10 sqm on plan and n exc 1.5m in depth and getting out complete. |
| 3 | Excavating in trenches n.exc 1.5 m wide and exc 1.5 m and n.exc 3 m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in soft/loose soil complete all as specified and as directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils. |
| 5 | Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point. |
| 6 | M&L cement concrete type D2 1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete. |
| 7 | M&L for plain cement concrete 1:2:4, type B1 (using 20 mm graded agg) as inFoundation filling and coping as specified and directed. |
| 8 | M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m meanradius, built with 1:4 cement mortar complete all as specified and as directed. |
| 9 | M&L for Brickwork with fly ashbricks, straight or curved on plan to any radius in half brick thick wall , built with 1:4 cement mortar complete all as specified and as directed. |
| 10 | Use and waste form work flats sides to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work ; not exc 200 mm thick complete all as specified and directed. |
| 11 | M&L for RCC (nominal mix ) type B1 1:2:4 (20 mm graded aggregate) as inslab supported on wall beam and coloumn in floor roof landing balconies canopies deck slab and in shelves, etc complete all as specified and directed. |
| 12 | M&L for TMT steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 13 | M&L for 15 mm thick rendering in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and directed. |
| 14 | M&L for preparation of newly plastered surfaces and applying two coats of cement base paint complete all as specified and directed. |
| 15 | M&L for glazed ceramic tiles in vertical surface 450X 350X 7mm thick set and jointed in10 mm thick neat cementmortar 1:3 slurry and pointed in white or colour cement to match complete all as specified and directed. |
| 16 | M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles all as specified and directed. |
| 17 | M&L for 20 mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed. |
| 18 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161 - 1979 grade St - 240 complete all as specified and directed. |
| 19 | S&F Joist, channel, angle, or tee sections, fixed independently, withoutconnecting plates, etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated) conforming to IS Fe 410-W(Gde-E- 250) quality- A complete all as specified and directed. |
| 20 | S&F MS screw bolts (Machine made) 11 to 15 mm dia of neck, with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exc 5 cm long complete all as specified and directed. |
| 21 | S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed. |
| 22 | S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified. |
| 23 | M&L 75 mm thick, plain cement concrete 1:4:8, type D-2(using 40 mm gradedstone aggregate) as in sub base of flooring, etc all as specified and directed. |
| 24 | M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete ® |
| 25 | M&L for 15mm thick Screed bed or bedding layer of cement mortar (1:6) for laying floor finishes all as specified and directed. |
| 26 | M & L PCC 1:3:6 type C-2 (75 mm) thick ( 40mm graded aggregate) thick as in plinth protection/Hard standing , etc finishing cement concrete surface even & fair whthout using extra cementmaking joints with bitumastic filling in proportion of bitumen and sand 1:2 complete all as specified and directed. |
| 27 | M&L for preparation of newuntreated steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chromeall as specified and directed. |
| 28 | S&F 1000 Ltrs rotational moulded polythelene water storage tanks (Cylinderical vertical with closed top) hoisted and fixed in position all as specified |
| 29 | M&L for mild steelframed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 Gde (E-165) complete all as specified and as directed. |
| 30 | S&F20 mm Ballvalves high pressure of PTMT with epoxy coat ed Aluminium rod & highdensity plastic ball screwed for ironpipe and fixed.(Minimum weight 2 0mm-210gms) |
| 31 | S&F for 15mm dia Tubes, \"medium grade\" galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors , wall etc ( surface or concealed type) all as specified and directed. |
| 32 | S&F for 20mm dia Tubes, \"medium grade\" galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors , wall etc ( surface or concealed type) all as specified and directed. |
| 33 | S&F for 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls .. |
| 34 | S&F for 75mm bore PVC (SWR) bends any radious provided with access door . |
| 35 | S&F for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls .. |
| 36 | S&F for 110mm bore PVC (SWR) bends any radious provided with access door . |
| 37 | S&F for 15 mm Bib taps, cast copper alloy fancy type chromium plated with capstan head screwed down screwed for iron pipe of 15mm boreand fixed in repair. |
| 38 | S&F 15mm bore stop valve fancy type chromium plated with long shank and cup (Concealed type) cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed. |
| 39 | S&F in repair Brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges |
| 40 | S&F for Vitreous China wash basin, white, flat back, size 580 X 450mm, (for Hospital use) excluding taps, waste, chain and plug and porcelain stopper but including brackets including cutting for and pinning in ends of brackets or erecting stand complete as in repair all as specified and directed. |
| 41 | S&F 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated,fancy type screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed. |
| 42 | S&F600 mm x 450mm bevelled edge mirrorwith glass shelf assembly of selected quality glass , mounted on 6 mm thick Ac Building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete as in repairs. |
| 43 | S&F in repairsfor brass chromium plated shower rose 125mm size with swivel joint including fixing to 15mm dia steel pipe or union. |
| 44 | M&Lfor hard core of broken stones of guage not exceeding 63 mm deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 45 | M&L for 100 mm thick plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in sub base of floor, etc complete all as specified and as directed. |
| 46 | M&L for Chequered cement concrete tiles 20 cm x 20 cm x 25mm thick set jointed and pointed in neat cement slurry 1:4 in floors with white cement andpigment complete all as specified and as directed. |
| 47 | S&F solid PVC door frames of size 50mm X 47mm made out of 5mm plain color PVC sheet reinforced with MS square tube complete all as specified & directed |
| 48 | S&F factory made solid panel PVC door shutter, 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded, plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom railon either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement all as per specification anddrawing and as directed. |
| 49 | S & F 150 mm long alumiminumbarrel tower bolts, stove enamelled black, with bright bolt complete. |
| 50 | S & Faluminium bow handles, cast type, anodised size 100 mm. |
| 51 | S & F 100mm long butt hings medium weight cold rolled mild steel & fixed to chowkats 75mm size all as specified and as directed. |
| 52 | Material and labour for point wiring for the followings with 1.5 Sqmm single core, PVC FRLSH insulated unsheathed, multistranded copper conductor drawn through and includingPVC conduit of suitable size not less than 20mm (medium grade) fixed to wall/angels including necessary accessories like bends, tees, PVC square and elbow etc fixed on wall/ceiling with 1.5 Sqmm PVC FRLSH insulated unsheathed multi stranded copper conductor cable as earth conitinuity (green in colour) connected to common earth dolly including PVC Box white color of suitable size complete all as specified and directed as below :-(a)One light/fan point controlled by one,one way switch. |
| 53 | Supply and fixing of switch piano white color flush type 240 Volts 5 Amps, SP, one way complete all as specifed/directed. |
| 54 | Supply and fixing ofceiling rose surface PVC/Polycarbonate, 65x50 mm two to three terminals complete all as specified/directed. |
| 55 | S&F LED batten (1.2M) made of extruded aluminum housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 18/20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a colour temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete all as specified and directed. (Make: Philips Cat Part No. BN170C LED20S-6500 PSU L120or its equivalent in Crompron / Havells, Bajaj. |
| 56 | Supply and fixing in repair of MCB Distribution board SPN 8 Way for mountingSPN/ SP MCBs as Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossyfinished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smoothfinish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and directed by Engr-in-charge. |
| 57 | Supply & fix of MCB SPN 32 Amps\"B\" Series 10 KA 240 volts complete all as specified/directed. |
| 58 | Supply & fix of MCB SP 6-10 Amps\"B\" Series 10 KA, 240 volts complete all as specified/directed. |
| 59 | Material and labour for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised wire of dia 4 mm as earthing lead by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar,funnel, wire mesh 20 mm bore galvanised (light grade) for watering, charcoal and salt in alternate layers including necessary execuation and eath works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I including taking out the old earthing material complete all as specified and directed.Note:No extra payment will be for the earthing GI wire of size 4 mm dia |
| 60 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with impact and corrosion resistant including thermalmanagement in multiple optics complete with IP 65/66 protection complete. |
| 61 | S&F street light bracket fabricated out of GI Tubing light grade 32 mm bore Bend to the shape as directed and of length 1.5 mtrcomplete with mounting MS clamp of flat iron size 40X5mm of suitable length 02 pairs incl nut bolts etc of suitable size, including taking down old corroded one all as specified and directed. |
| 62 | Supply and spread sand in trenches as sand cushioning to underground cable for protection with fine river sand and provide required cover after punning down complete all as specified and directed. (Note: Thickness of sand cushion after punning down will be measured and paid.) |
| 63 | Supplying and laying un-reinforced precast concrete cable cover, classClass LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and directed. |
| 64 | Supply, laying & testing cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of size 16 sqmm 2 core, 1100 volts grade complete all as directed. |
| 65 | S & F GI pipe`Lightgrade\", 32 mm Bore dia includingall fitting; laid in trenches or fixed on wall. |
| 66 | Material & labour for Sub main wiring with two runs of single core 4 Sqmm (Nominal Area) FRLSH PVC insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn thorugh and including PVC conduit of adequate size fixed on surface of wall/ceiling with all necessary fittings and accessaries and 1 run of FRLSH PVC insulated and unsheathed insulated single core cable with multi standered copper conductor of size 4 Sqmm as earth wire (green in colour) run through PVC Conduit and connected common earth dolly including taking out the old sub main wiringfor connection to DBs/dolly shall be deemed to be included in this item and Two runs of 4 Sq mm as current carrying conductor and one run of4 Sq mm as earth conductor PVC conduit shall be measured as one run for measurement, complete all as specified and directed.(For solar water heater connection) |
| 67 | Supply and lay Tubes, \"medium grade\", galvanised, with all fitting; laid in trenches or fixed on wall of 25 mm bore complete all as directed. |
| 68 | All as per item No 67 here in before but using tube size 40mm bore |
| 69 | Supply and fix Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for ironpipe and fixed of size 25 mm complete all as directed. |
| 70 | All as per item No 69 here in before but using valve size 40mm bore |
| 71 | M&L for Cutting existing pipe of any size for inserting of TEE for connection of GI Pipe of 40mm dia complete all as directed. |
| 72 | M&L construction of brick masonry valve chamber of size 400mm x 400mm x 400mm (Internal dimension) with PCC 1:3:6 foundation 150mm thick, brick work 23cm thick built in CM 1:6, PCC 1:3:6 coping 50 mm thick, plastering 15mm thick in CM 1:4 to all internal and exposed surfaces including excavation earth work in any type of soil, MS sheet cover 3mm thick fixed with angel iron frame 30x30x4 mm including hinges of size 125mm with locking arrangement embedded in PCC and painting ot MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified and directed. |
| 73 | Supply, Install, Testing and Commissioning of \"Solar Hot Water System\" (Flat Plate Collector) with electric heating system based on indirect transfer of heat of capacity 500 LPD |
| 74 | Supply and fix rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) capacity 1000 Litres hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed. |
| 75 | S&F Cross arms, bracings, supports, clamps, MS Plain black sheets and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed. |
| 76 | Cutting existing steel tubing of 40/50mm for alterations or additions for insertion of TEEs complete all as specified and directed |
| 77 | Supply & fix for 3-layer PP-R (Polypropylene random copolymer) pipe of size 32mm SDR 7.4 & SDR 11 UV stablised and Antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed with repair and finishing of damaged walls, ceilings or in floors etc complete all as specified and directed. |
| 78 | Supply & fixing of Tube of 25 mm, \"Medium grade\" galvanised, with all fitting and laid in trenches complete all as specified and directed. |
| 79 | Supply & fix PP-R Gate valve of size 32 mm (brass insert) as per requirement of the site complete all as specified and directed. |
| 80 | Supply & fix Stop valves 25mm, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for ironpipe or for unions and fixed complete all as specified and directed. |
| 81 | Supply and fix 25mm ball valves high pressure of PTMT with epoxy with epoxy coated aluminium rod &high-density plastic ball screwed for iron pipe and fixed.(Minium weight 25mm-455gms. |
| 82 | M&L for Cement concrete type B-2, 1:2:4 (40 mm graded aggregate) 100 mm thick as in floor complete all as directed. |