| 1 | M&L for preparing old undecorated surface of wall etcincluding cleaning with broom and applying one coat of exterior weather proof paint complete all as specified and as directed by Engr-in-Charge. Note:-1.The work shall be executed in multistoried buildings upto 10.00 mtr height by providing necessary scaffolding duly adhering all safety precaution while carrying out the works. 2.The cost of scaffolding shall be deemed into the quoted rate and nothing shall be extra payment to contractor. |
| 2 | M&L for preparing old undecorated surface of wall etcincluding cleaning with broom and applying two coat of exterior weather proof paint complete all as specified and as directed by Engr-in-Charge.Note:-1.The work shall be executed in multistoried buildings upto 10.00 mtr height by providing necessary scaffolding duly adhering all safety precaution while carrying out the works. 2.The cost of scaffolding shall be deemed into the quoted rate and nothing shall be extra payment to contractor. |
| 3 | M&L forpreparation of old surfaces of walls by complete removal of existing treatment and applying Wall carewhite ( Putty) thickness not less than 2-3mmand sand papering surfaces to achieve smooth surfaces complete all as specified . Note:-1.The work shall be executed in multistoried buildings upto 10.00 mtr height by providing necessary scaffolding duly adhering all safety precaution while carrying out the works. 2.The cost of scaffolding shall be deemed into the quoted rate and nothing shall be extra payment to contractor. |
| 4 | Taking down cement plaster on Brickor concrete surfaces incl racking out joints hacking for key scrubbing downwith water etcand M & L rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finishing even and smooth without using extra cement in patches as in roof top parapet, ceiling of facia and wall complete all as specified and as directed by the Engr-in-charge. |
| 5 | M&L for preparing of new surface of wall and applying two coat of exterior weather proof paint complete all as specified and as directed by Engr-in-Charge. |
| 6 | M & Lfor one coat of white wash after preparation of decorated old plastered or unplastered surfaces of ceilings by brooming down or steel wire brushing , scrapping down smoke soot , moulds, moss and efflorescent salts and treating oil and greasy spots complete all as specified and directed. |
| 7 | M&L for one coatof oil bound distemper after preparation of old decorated distempered surfaces on ceiling surfaces of approved tint and make all as specified and directed by Engineer in charge |
| 8 | M&L for two coatof oil bound distemper after preparation of old decorated distempered surfaces on ceiling surfaces of approved tint and make all as specified and directed by Engineer in charge |
| 9 | M & Lfor two coat of white wash after preparation of decorated old plastered or unplastered surfaces of wall by brooming down or steel wire brushing , scrapping down smoke soot , moulds, moss and efflorescent salts and treating oil and greasy spots complete all as specified and directed. |
| 10 | M&L for one coatof oil bound distemper after preparation of old decorated distempered surfaces on walls surfaces of approved tint and make all as specified and directed by Engineer in charge |
| 11 | M&L for two coatof oil bound distemper after preparation of old decorated distempered surfaces on walls surfaces of approved tint and make all as specified and directed by Engineer in charge |
| 12 | Taking down cement plaster on Brickor concrete surfaces incl racking out joints hacking for key scrubbing downwith water etcand M & L rendering 10 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finishing even and smooth without using extra cementcomplete all as specified and directedby the Engr-in-charge |
| 13 | M&L for two coatof oil bound distemper after preparation of new surface of walls of approved tint and make all as specified and directed by Engineer in charge |
| 14 | Preparation of old painted surfaces of wood and wood based surafces of any description, not otherwise described over 10 cm width or girth complete and applying a coat of synthetic enemal paint all as specified and as directed by Engr-in-Charge. |
| 15 | Preparation of old painted surfaces of wood and wood based surafces of any description, not otherwise described over 10 cm width or girth complete and applying two coat of synthetic enemal paint all as specified and as directed by Engr-in-Charge. |
| 16 | Preparation of old painted steel surfaces of any description, not otherwise described over 10 cm width or girth and applying a coat of synthetic enemal paint complete all as specified and as directed by Engr-in-Charge. |
| 17 | Preparation of old painted steel surfaces of any description, not otherwise described over 10 cm width or girth and applying two coat of synthetic enemal paint complete all as specified and as directed by Engr-in-Charge. |
| 18 | M&L for preparation of new/old plastered surface and applying priming coat and providing heritagefinish ( Texture finishin any design) in any shade to colour as approved by Engineer-in-Charge and as per manufacture instructions complete all as specified and directed. |
| 19 | S&F 3.0 mm thick plain sheetin square n exc 0.5 sqm each pane with oil putty comp/pins complete all as specified and directed by Engr-in-charge and hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/ spring clips. |
| 20 | Repairs to broken edges of roof projection , chajja, facia, Fins and simillars worksgirth n exc 45 CM with 15 mm thick plaster including cutting of reinforcement as required , dubbing coat in CM 1:3, required PCC 1:2:4using 12.5 mm stone aggregateup to 4th storey bldgs complete all as specified and directed by EIC. |
| 21 | Cleaning and removing all scale and dirt etc from tanks exc 250 ltr and n.exc 500/1000 ltr capacity and from mouths of circulating pipe date of cleaning to mentioned completed all as specified. |
| 22 | M&L Rolled MS Joist, channel, angle, grill or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe 410 -W (Gde- E-250) quality A for water tank caging etc upto 10.00 mtr height of bldgs. |
| 23 | M&L for Welded steel wire fabric supplied and fixed completeto steel membersincl necessary welding n exc 4 Kg complete all as specified and as directed for water tank caging etc upto 10.00 mtr height of bldgs. |
| 24 | Preparation of old painted steel surfaces of any description, not otherwise described over 10 cm width or girth and applying two coat of synthetic enemal paint complete all as specified and as directed by Engr-in-Charge. |
| 25 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings heads, shoes, bends, swan-necks, etc., incl cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) |
| 26 | S&F 110 mm borePVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall incl necessary clamp etc complete all as specified. |
| 27 | S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall incl necessary clamp etc complete all as specified. |
| 28 | S&F in repair 110mm PVC (SWR) bends any radius |
| 29 | S&F in repair 75mm PVC (SWR) bends any radius |
| 30 | S & F in repair MS cover 0.56 mm sheet cover over PVC tank circular top cover for 300/500 ltr capacityand clip type bolt for locking arrangement for side openingand suitable on over 50mm long nail withsnap edge on top cover for protection from monkey complete all as specified and directed by Engr-in-charge. |
| 31 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa of AZ150 as in roof covering/cladding to walland rain water gutter fixed with self tapping screws including dismantling plain or corrugated Asbestos cement (Corrugated, semi corrugated etc) sheet complete all as specified and directed. |
| 32 | S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples. |
| 33 | Note:-1.The work for Srl No 01 to 32 shall be executed in multistoried buildings upto 10.00 mtr height by providing necessary scaffolding duly adhering all safety precaution while carrying out the works.2.The cost of scaffolding for srl item No 1 and 31 shall be deemed into the quoted rate and nothing shall be extra payment to contractor.3. Removing of Nails, making good holes, cracks etc.4. Work in patches and in narrow / widths, bands, cornices, pilasters etc and cutting in edge of line where necessary.5. Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes. |