| 1 | M & L for wiring for circuit /sub main wiringwith earth wire of size 2x 2.5sqmm + 1 x2.5sqmm of FRLS PVC insulated copper conductor, single core cable in surface / recessed as required drawing in and including rigid PVC medium grade cunduit concealed / on ceiling as per site required or directed by Engr-in-Charge. Including taking down old unserviceable/damaged Sub main wiring of any type and size including continious earth wire, conduit/casing capping / Batten etc,making good disturbed surfaces of walls/ceiling with CM 1:3 andmatching surfaces with existing colour. |
| 2 | M & L for wiring for circuit /sub main wiringwith earth wire of size 2x 4.0sqmm + 1 x4.0sqmm of FRLS PVC insulated copper conductor, single core cable in surface / recessed as required drawing in and including rigid PVC medium grade cunduit concealed / on ceiling as per site required or directed by Engr-in-Charge. Including taking down old unserviceable/damaged Sub main wiring of any type and size including continious earth wire, conduit/casing capping / Batten etc,making good disturbed surfaces of walls/ceiling with CM 1:3 andmatching surfaces with existing colour. |
| 3 | M & L for wiring for circuit /sub main wiringwith earth wire of size 2x 6.0sqmm + 1 x6.0 sqmm of FRLS PVC insulated copper conductor, single core cable in surface / recessed as required drawing in and including rigid PVC medium grade cunduit concealed / on ceiling as per site required or directed by Engr-in-Charge. Including taking down old unserviceable/damaged Sub main wiring of any type and size including continious earth wire, conduit/casing capping / Batten etc,making good disturbed surfaces of walls/ceiling with CM 1:3 andmatching surfaces with existing colour. |
| 4 | S & F sheet metal enclosures (double door) for DBs where MCBs to be used triple pole and neutral 4 way 415 V with rated bus bar fixed on wall (flush/surface as ordered). Including taking down DBs/Main switches / Busbar box of any type and capacity and removing from site. |
| 5 | S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 12 way 240 V with 200 ampsrated bus bar fixed on wall (flush/surface as ordered). Including taking down DBs/Main switches / Busbar box of any type and capacity and removing from site. |
| 6 | S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 8 way 240 V with 200 ampsrated bus bar fixed on wall (flush/surface as ordered). Including taking down DBs/Main switches / Busbar box of any type and capacity and removing from site. |
| 7 | S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 4 way 240 V with 200 ampsrated bus bar fixed on wall (flush/surface as ordered).Including taking down DBs/Main switches / Busbar box of any type and capacity and removing from site. |
| 8 | S & F sheet metal enclosures (single door) for DBs where MCBs to be used single pole and neutral 2 way 240 V without bus bar fixed on wall (flush/surface as ordered).Including taking down DBs/Main switches / Busbar box of any type and capacity and removing from site. |
| 9 | Supply and fix CRCA sheet metal enclosures distribution board double door,TPN vertical DB 4 way suitable for fixing of Four pole MCCB as in commer & MCBs SP as out going and duly fitted with Bus bar, neutral link, blanking plates, conforms IS 8623-1 & 3, IEC 61439-1 & 3, IK 09 etc complete.The DB shall be included with one No MCCB, 4 pole, 415/430 Volt, 50 Hz, Ics=100% of Icu, having rupturing capacity 16 kA on 415 V icu of capacity 100 Amps complete all as specified and directed.Encloser & MCCB shall preferably of same make. ( MCB s required for out going shall be measured and paid seperately) |
| 10 | S & F incl connecting MCB single pole, having rupturing capacity 10kA,6 amps to 32 amps as ordered 240 Volts complete all as specified and directed |
| 11 | S & F MCB Single pole and neutral (SPN), having rupturing capacity 10kA, 240 V 20 Amps to 32 amps as ordered complete all as specified and directed |
| 12 | S & F MCB Single pole and neutral (SPN), having rupturing capacity 10kA, 240 V 40 Amps to 63 amps as ordered complete all as specified and directed |
| 13 | S & F MCB triple pole (TP), having rupturing capacity 10kA, 240 V 25 to 63 amps as ordered complete all as specified and directed |
| 14 | S & F MCB triple pole and neutral (TPN), having rupturing capacity 10kA, 240 V 16 to 32 amps as ordered complete all as specified and directed |
| 15 | S & F MCB triple pole and neutral (TPN), having rupturing capacity 10kA, 240 V 40 to 100 amps as ordered complete all as specified and directed |
| 16 | M & L for earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6.0 mm burried directly in ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected to and including galvanised iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No. 5 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, cast iron cover with lifting handle, funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 40 mm bore light grade 7.5 m long test point etc complete including taking down old U/S earthing.Note :- (i) Cost of earth strip and GI protection pipe up to a distance 7.5 metre shall be included inthe quoted rate. (ii )On testing after completion if the desired earth resistance less than 2 ohm is not obtained the earthing will be redone at no extra cost. |
| 17 | Taking down carefully existingunserviceable copper/aluminiumpoint wiring (light, fan, socket orpower point etc)completewith fittings/fixures such asswitches sockets, ceiling rose, fan regulators, etc ( except tube light fittings), removing materials for taking credit and making good disturbedsurface of wall, floors, etc complete all asdirected by Eng-in-Charge. |
| 18 | M & L Point wiring complete with 1.5 sqmm single core PVC insulated (FRLS) andunsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVCConduit 20 mm dia and all accessoriesConcealedinwalls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for the following: - Make :- Polycab / Havells / RR kabels |
| 19 | One light / ceiling fan / exhaust fan / call bell point controlled by one switch |
| 20 | One 3 pin socket outlet 5 Amps independent board. |
| 21 | One 3 pin socket outlet 5 Amps on the same board with other switch. |
| 22 | All as per item No.18 here-inbefore but with 2.5 sqmm PVC insulated multistranded flexible unsheathed copper conductor inclusive of 2.5 sqmm PVC insulated multistranded flexible copper conductor for one independent 6 pin 16 Amp socket. |
| 23 | All as per item No 18here-in-before but for one light point controlled by two 2 way switches , with cable 1.5 sqmm. |
| 24 | M & L for point wiring with 1.5 sqmm PVC insulated (FRLS) multistranded fiexible unsheathed copper conductor drawn in and including 1.2mm thick PVC casing capping inclusive of one PVC insulated stranded copper conductor of size 1.5 sqmm as earth continuity conductor and terminated in common earth dolly incl provn of pressed steel boxes(fixed flush to wall) for mounting switches, sockets, regulator etc along with2.8mm thick bakelite sheet duly making opening for fixtures for the following points:- Make :- Polycab / Havells / RR kabels |
| 25 | One light / ceiling fan / exhaust fan / call bell point controlled by one switch |
| 26 | One 6 Amp socket outlet point independent |
| 27 | All as per item No 21here-in-before but one 3 pin socket out let 6 Amps on same board with other switches, with cable 1.5 sqmm. |
| 28 | All as per item No 21 here-in-before but for one light point controlled by two 2 way switches , with cable 1.5 sqmm. |
| 29 | All as per item No.21 here-inbefore but with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor inclusive of 1.5 sqmm PVC insulated flexible copper conductor as in continiousearth forone independent 6 pin 16 Amp socket. |
| 30 | S & F switch piano flush type SP one way 6 Amp. |
| 31 | S & F switch piano flush type 2 way 6 Amp. |
| 32 | S & F for switch socket combination 2 in 1, 3 pin, 6 and 16 amp flush typeuniversal. |
| 33 | M & L for switchSocket combination outlet 2 in 1 , 5 pin, 6 Amps flush type. |
| 34 | M & L for Socket outlet 2 in 1 , 3 pin, 6 Amps flush type. |
| 35 | S & F lamp holder,Polycarbonate type with back plate for batten angle fitting for B22 bulb complete all as specified and directed |
| 36 | S & F Bell Push, flush type, 6 Amps complete all as specified and directed |
| 37 | S & FDing Dong call bell AC, 230 Volt, single Pole complete all as specified and directed |
| 38 | S & F electronic fan regulator 230 voltsflush mounted 200/300 watt stepped type complete all as specified and directed |
| 39 | S & F ceiling rose surface polycarbonate body three terminal complete all as specified and directed |
| 40 | Supply and fixing for replacement of Modular type switch 1 way 6A, 1module, 230 V,AC50Hz ISI Marked with valid CML No. complete all as all as specified and directed |
| 41 | Supply and fixing for replacement of Modular type switch 1 way 20A, 1module, 230 V,AC50Hz ISI Marked with valid CML No. complete all as all as specified and directed |
| 42 | Supply and fixing for replacement of Modular type socket outletmultipurpose having provision for 3 pin 16A and 3 pin 6A, 2 module, 230 V,AC50Hz ISI Marked with valid CML No. complete all as specified and directed |
| 43 | Supply and fixing for replacement of Modular type Fan step regulator electronic type, 230V,120W- 1 module ISI marked with suitable CML No and connecting upto complete all as specified and directed |
| 44 | Supply and fixing for replacement of Modular type Fan step regulator electronic type, 230V,120W- 2 module ISI marked with suitable CML No and connecting upto complete all as specified and directed |
| 45 | Supply & Fix for replacement of modular White cover platefor followingmodule complete all as specified and directed :- |
| 46 | 2 module |
| 47 | 3 module |
| 48 | 4 module |
| 49 | 6 module |
| 50 | 8 Module |
| 51 | 12 Module |
| 52 | 16 Module |
| 53 | Taking out damaged sunken box from its position by cutting Brick wall and supply and fixing of new modular Metal flush box of following sizes duly cutting grooves, making good disturbed surfaces of wall with CM 1:3 and finaly finishing the wall with colour wash as per existing tint complete all as specified and directedNote:- All fixtures such as switches,sockets,regulator , modular cover plates etc shall be measured and paid seperately. |
| 54 | 1/2 Module |
| 55 | 3 Module |
| 56 | 4 Module |
| 57 | 6 Module |
| 58 | 8 Module |
| 59 | 12 Module |
| 60 | 16 Module |
| 61 | Supply & Fix for replacement of modular PVC board surface mounted box with plate , of 3 module for 6/16 Amp switch and socket,complete all as specified and directed |
| 62 | Supply & Fix for replacement of modular PVC board surface mounted box with plate , of 3 module for 6 Amp switch and socket,complete all as specified and directed |
| 63 | S & F in repair ceiling fan capacitor of capacity2.5 MFD , 440 V , all as specified and directed |
| 64 | Taking down old existing tube rod and Supply and fixing new ultra bright LED Tubelight 20 watt (single side connection) with very high efficacy & THD <15% best suited for installation in existing tubelight luminaire with G13 lamp holders to give glare free light. , input voltage 140-270 V AC,CCT 6500K, Lumin efficency 100 lm/watt , complete all as specified and directed byEngr -in -charge. Note Warrenty on light should be of minimum 02 Years. |
| 65 | Supply and fixing LED batten lights fittingmade of Aluminium extrusion 1x 20W (4 feet) , input voltage 140-270 V AC,CCT 6500K, Lumin efficency 100 lm/watt ,surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 , connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed byEngr -in -charge. Including Taking down old Tublight fittingsNote :-Warrenty on light should be of minimum 02 Years. |
| 66 | Supply and fixing LED batten light fitting made of Aluminium extrusion mirror type with high out put diffuser 1x10 watt(2 feet) , input voltage 140-270 V AC,CCT 6500K, Lumin efficency 100 lm/watt ,surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 with driver including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed by Engr in charge.Including Taking down old Tubelight fittingsNote:-Warrenty on light should be of minimum 02 Years. |
| 67 | Taking down old existing fitting any type and S & F of recess / surface mounting LED flat panel 2\"X2\" made of sheet steel housing duly powder coated with high efficient LEDs & glare free full opal diffiuser, IP20 of capacity 36 watt ,input voltage 140 -270 V AC , CCT 5700 K,lumin efficency 120lm/watt, surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 ,complete all as specified and directed. Note Warrenty on light should be of minimum 02 Years. |
| 68 | S & F of LED street light fitting 20 Watt 230 V ACCCT 5700K Lumens ≥100 lm/wattoutdoor type with high pressure die cast Aluminium housing high power led as lighting source and lens embedded pc cover having top opening seperate driver compantment and impact resistance of IK 07 WITH 10KV,OEM driver,PF 0.9, built in surge protection deviceheat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection .including bracket made out of GI pipe light grade 32mm bore not less than 1.20m long bent to shape required fixed to pole with suitable size 2 Nos clamps made out of 25X3mm flat iron with nut, bolts and washers completecomplete all as specified and directed.Note :- The warranty on light should be minnimum of 2 Years . |
| 69 | S & F LED light fitting 1x15 W bulkhead luminaires Pressure die cast aluminium housing crystal white lumens 100lm/watt IP-65 including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr in charge.Note Warrenty on light should be of minimum 02 Years. |
| 70 | Taking down old existing any type of lamp & Supply and fix of 9 W LED lamp suitable for B22 capacity all as specified and directed. |
| 71 | Supply & fix of exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50Hz, RPM 1200, copper winding of sweep 250mm including exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV exhaust fan complete all as specified and directed.Note :1) Old unserviceable Exhaust fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. |
| 72 | Supply & fix of exhaust fan steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers, voltage 230V, 50Hz, RPM 1200, copper winding complete including exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV exhaust fan complete all as specified and directed.Note :1) Old unserviceable Exhaust fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. |
| 73 | Supply & fix of ceiling fan complete with blades, down rod from existing roof / trus to fall ceiling, electronic regulator and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV ceiling fan complete all as specified and directed.Note :1) Old ceiling fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. |
| 74 | Supply & fix for replacement of metal clad box with plug and socket 20 Amps with one MCB SPN of 20 Amps complete all as specified and directed |
| 75 | Supply & fix for replacement ofplug for metal clad box complete all as specified and directed |
| 76 | Supply & fix for replacement of socket for metal clad box complete all as specified and directed |
| 77 | S&F\"Modular AC Box With 20A SP MCB,Metal Enclosure & Unbreakable Heavy Duty With ISI Plug Top\" flush mounting enclosure complete all as directed by Engineer-in-Charge |
| 78 | Taking down old existing fitting any type and S & F of LED Recess mountedDown Light Round type with independent electronic LED driver ,made from cast aluminium housing and opaue polymer diffuser for optimum light output as per site requirementround light fitting of capacity 12 Watt, input voltage 140 -270 V AC , CCT 5700 K,lumin efficency 120lm/watt, surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 suitable for mounting with Armstrong/Grid ceiling with complete flexibility,complete all as specified and directed.Note :- Warrenty on light should be of minimum 02 Years. |
| 79 | Taking down old existing fitting any type and S & F of LED Recess mountedDown Light Square type with independent electronic LED driver ,made from cast aluminium housing and opaue polymer diffuser for optimum light output as per site requirementSquare light fitting of capacity 18 Watt, input voltage 140 -270 V AC , CCT 5700 K,lumin efficency 120lm/watt, surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 suitable for mounting with Armstrong/Grid ceiling with complete flexibility,complete all as specified and directed.Note :- Warrenty on light should be of minimum 02 Years. |
| 80 | S&F PVC conduit of size 20mm dia including fixing on wall/ceiling with suitable clamp/saddles for wiring wire all as required at site. |
| 81 | S&F PVC conduit of size 25/32 mm dia including fixing on wall/ceiling with suitable clamp/saddles for wiring wire all as required at site. |
| 82 | S&FPVC casing caping of size 1\" x 1/2\" including fixing on wall/ceiling with clamp/saddles for wiring wire all as required at site |
| 83 | M & L for single core 1 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked |
| 84 | M & L for single core 1.5 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked |
| 85 | M & L for single core 2.5 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked |
| 86 | M & L for single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked |
| 87 | M & L for single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked |