| 1 | Taking down cement plaster, terrazzo dado in any thickness from brick or stonewalls etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish, vegitation outside complex (MOD land), complete all as specified. |
| 2 | M&L for rendering 15mm thick in CM 1:4 on fair faces or other than fair faces of brick work or concrete surfaces, man holesfirnished een and smooth without using extra cement with water proofing treatment. (wpc measured seperately.) |
| 3 | M&L for rendering 15mm thick in CM 1:6 on fair faces or other than fair faces of brick work or concretesurfaces of walls, man holes firnished even and smooth without using extra cement. |
| 4 | M&L for preparation of newly plastered surfaces of walls and providing and applying putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified as directed by Engr-in-charge. |
| 5 | Demolition of brick work built in cement mortar incl all quoins, arches, pillars etcComplete all as specified. |
| 6 | M&L PCC 1:4:8 type D2 using 40mm graded stone aggregates as in foundation of manholes, posts etc completeall as specified. |
| 7 | M&L for brick work with sub class \"B\" bricks old size bricks strainght or curved on plan exc 6m mean radius built in CM 1 : 4complete all as specified. |
| 8 | M&L for PCC 1:2:4 type B2 using 20mm graded aggregates as in surfaces channels and drains complete all as specified. |
| 9 | M&LProviding pre cast RCC type B1 20mm graded aggregate 1:2:4in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces |
| 10 | M&L for 75 mm thick cement concrete 1:3:6type C2(using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished fair and even without using extra cement, complete all as specified. |
| 11 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for |
| 12 | M&L for providing cement concrete coping with plain fair faces incl chamferes, weathering,throating etc type B1, 1:3:6using 20mm graded aggregate and set in CM 1 : 4 complete all as specified. |
| 13 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete. |
| 14 | M&L formachine pressed precast concrete interlocking paver block with gray cement and no pigment, any shape and size confirming to IS- 15658 -2006 of 60mm thickness, M-40 Gde,Over and including 20mm thick layer of sand completeall as specified and directed. |
| 15 | M&L for 100mm thick PCC (1:4:8) Ty D2 as in sub base over rammed earth. |
| 16 | M&L for 50mm thick PCC 1:3:6 type C2 using 20mm graded stone agg as in sub base complete all as specified. |
| 17 | M&L for 22 to 25mm chequered ultra tiles over 15 mm thick screed bed in cm 1:6 and jointed and pointed in white cement mixed with pigment to match the shade of tiles of flooring all as directed. |
| 18 | S&F Exterior Endura Chequered cement concrete colour tiles 30cm X 30cm x 10mm thick set, jointed and pointed in neat cement slurry in floors with grey cement and pigments incl 15 mm thick screed bed or bedding layer for laying floor finishes of tiles CM 1:6 Complete all as specified and directed by Engineer-in-Charge. |
| 19 | S & F in replacement for precast fibre reinforced cement concreteManhole cover (Ist quality) including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 1000mmx500mmx80mm omplete all as specifiedand as directed. |
| 20 | S & F in replacement for precastplastic fibre reinforced cement concrete Manhole covers with frame medium duty of overall size 450mmx900mmx50mm factory made all as specified and directed by Engineer-in-Charge. |
| 21 | S & F in replacement for precast fibre reinforced cement concreteManhole cover (Ist quality) including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 900mmx900mmx80mm omplete all as specifiedand as directed. |
| 22 | Dismantling fencing wire mesh, any type |
| 23 | Dismantling wrought iron or mild steel work of any description not otherwise provided for roof trusses and purlins complete all as specified and as directed. |
| 24 | M&L for cement concrete type D2 1:4:8(40mm graded aggregate) as in foundations, filling and mass concrete. |
| 25 | S&F mild steel as in hand rail, balusters, noising to steps, post and struts in fencing including cutting tops to shape as directed, driliing holes, notching for wire, drilling, bolting or riveting etc, conforming to Fe-290, Gde-E-165 including two coats of synthetic enamel paint over a coat of red oxide primer compete all as specified and as directed by Engineer-in-charge. |
| 26 | Supply only 3.15 mm dia galvanised steel chain link fencing, 50x50 mm mesh, made up to into mattrsses or cages, lapped, wired a all as specified. |
| 27 | Fixing only chain link fencing including line wires any mesh, size and type to any to any type of standard, rail, straining bolts, etc provn of winding wire all as specified. |
| 28 | M&L Mild steel Round 10mm dia conforming to FE-410-W (Gde-E-250) qualility A or FE-290 (Gde E-165) for use in chain link fencing as wind tie all as specified. |
| 29 | Mild steel screw bolts (machine made) with hexagonal or square heads at one end screwed the other, the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 30cm and dia of neack exc 12mm but not exc 20mm complete all as specified and as directed by Engineer-in-charge. |
| 30 | Dismantling corrugated steel sheeting, any gauge, thickness complete all as specified and as directed. |
| 31 | S&F in repair 2mm thick fibre glass reinforced translucent plain sheeting withside lap fixed with srew. |
| 32 | S&F Steel work in tubular trusses including special shaped washer etc. complete usingERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 ® |
| 33 | S&F Pre-painted galvalume aluminum Zinc coating GI based Corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 34 | M&L for Preparation of new or previously untreated steelsurfaces of any description, over 10 cm width or girth, not otherwise described, and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified. |
| 35 | Schedule of Credit |