| 1 | ACCESS PLATFORM / WORKING PLATFORM: Providing, fabricating, erecting, and maintaining temporary access/working platform above water level using approved steel or wooden supports for carrying out surface preparation, drilling, shuttering, and associated repair works.Including cost of all materials, labour, T&P, staging, scaffolding, pontoons, boats, barges, hire and running charges of machineries, safety arrangements, supervision, and all incidental charges, complete as directed by the Engineer-in-Charge. |
| 2 | TEMPORARY BOTTOM SUPPORT BELOW SLAB (FOR RETROFITTING) :Providing, fabricating, erecting, maintaining, and dismantling temporary bottom support below slab for retrofitting, consisting of 2 Nos. ISMB 250 per 4.00 m span with 3 Nos. vertical steel supports, complete with base plates, bolts, welding, bracing, and alignment. Includes all materials, fabrication, erection, lifting arrangements, labour, equipment hire, dismantling, and removal after completion, complete as directed by the Engineer-in-Charge. |
| 3 | CUTTING & REMOVING OF EXISTING CANTILEVER RCC Handrail: Dismantling and demolition of existing RCC walkway/slab using chain saw or non-vibratory chipping system, including removal of debris, stacking of serviceable materials, and disposal of unserviceable waste to approved dumping area.Including cost of labour, tools, machinery, boats, barges, loading, unloading, transportation, and all incidental charges, complete as directed by the Engineer-in-Charge. |
| 4 | CONDUCTING NDT PRE & POST REPAIR SURVEY: Conducting Non-Destructive Testing (NDT) including Half-Cell Potential and Ultrasonic Pulse Velocity (UPV) tests on selected short columns, diagonal bracings, deck beams, and deck slabs — minimum six (6) locations per component in five (5) stages — as per relevant standards.Including cost of instruments, calibration, operation, data recording, hire and running of boats/barges, labour, mobilisation, demobilisation, data analysis, and report submission, complete as directed by the Engineer-in-Charge. |
| 5 | SURFACE PREPARATION: Carefully chip and remove cover concrete up to the rear face of reinforcement using electric chippers and hand tools, followed by thorough cleaning of exposed surfaces and rebars with high-pressure water jet to remove loose particles, rust, and marine growth.Including cost of all materials, labour, T&P, compressor, pneumatic tools, water jet equipment, barge/boat access, and all incidental charges, complete as directed by the Engineer-in-Charge. |
| 6 | CORE DRILLING: Core drilling of 77 mm dia holes through RCC deck slab to the required depth for facilitating micro-concrete pouring, using an electrically operated core drilling machine with proper alignment and marking. The drilled holes shall be cleaned and refilled with non-shrink micro-concrete after grouting to restore integrity. Including cost of all labour, T&P, core drilling machine, drill bits, accessories, and all incidental charges, complete as directed by the Engineer-in-Charge. |
| 7 | ANCHORING OF MAIN / SECONDARY REINFORCEMENT: Anchoring reinforcement bars of specified diameters using Lokfix / Hilti RE10 / RE100 resin grout, including drilling holes at required positions with low-vibration rotary hammer, cleaning with air/water, filling resin to two-thirds depth, and inserting bars to specified embedment.Including cost of all materials, labour, T&P, drilling machine hire, consumables, and all incidental charges, complete as directed by the Engineer-in-Charge. |
| 8 | ANCHORING OF SHEAR CONNECTORS: Anchoring 10 mm dia shear connectors at specified locations by drilling holes with 10 mm pilot and 16–18 mm final drill bits using low-vibration hammer drill, cleaning thoroughly with air/water, and fixing using Lokfix / Hilti RE10 / RE100 resin grout filled up to two-thirds depth.Including cost of all materials, labour, T&P, drilling equipment hire, consumables, and all incidental charges, complete as directed by the Engineer-in-Charge. |
| 9 | FIXING OF GROUTING NIPPLES: Supplying and fixing non-return type grouting nipples at 300 mm c/c spacing using polyester resin anchoring grout along identified cracks between pile–pile cap and pile cap–deck beam junctions, including surface preparation, positioning, and secure fixing to withstand grouting pressure.Rate includes cost of all materials, resin grout, labour, T&P, hire charges of compressor, pneumatic tools, diving equipment, and all incidental expenses, complete as directed by the Engineer-in-Charge. |
| 10 | LOW VISCOUS EPOXY GROUTING: Providing and injecting low-viscosity epoxy grout into cracks of concrete members after surface preparation and sealing using suitable epoxy sealing compound for bonding of nipples, spaced 200–500 mm c/c based on crack width and depth.Epoxy components shall be mixed mechanically and injected through a grout pump under controlled pressure to ensure full penetration.Rate includes cost of all materials, grout pump, mixing tools, labour, safety gear, supervision, and all incidental charges, complete as per specification and direction of the Engineer-in-Charge. |
| 11 | STRENGTHENING OF CORE CONCRETE FOR PILES / DECK BEAM / DECK SLAB BY GROUTING WITH MICROFINE CEMENT: Providing and injecting microfine cement grout (particle size 6–12 microns) into piles, deck beams, and deck slabs using a water–cement ratio of 1.2, modified with expanding additive @ 225 g per 25 kg MFC and SBR polymer @ 3 L per 25 kg MFC.The mix shall be mechanically prepared and injected under controlled pressure through pre-fixed nipples using an electrically operated grout pump.Rate includes cost of all materials, additives, polymers, equipment hire, labour, scaffolding/working platform, and all incidental charges, complete as per specification and direction of the Engineer-in-Charge. |
| 12 | ADDITIONAL REINFORCEMENT: Supplying, cutting, bending, and placing in position MS/RTS reinforcement bars of approved grade and diameter as per approved drawings and IS 1786, including tying with 16-gauge binding wire, providing necessary supports, chairs, and spacers to maintain proper alignment and cover.Rate includes cost of steel, wastage, fabrication, labour, tools and plants, welding (if required), transportation, loading, unloading, and all incidental charges, complete as per specification and direction of the Engineer-in-Charge. |
| 13 | PROVISION OF SACRIFICIAL ANODE (GALVASHIELD XPI OR EQUIVALENT) : Providing and fixing sacrificial anode type corrosion protection system such as GALVASHIELD XPI or equivalent(2 Nos per structural member), over the main and bracket reinforcements, in accordance with the manufacturer’s specifications and approved drawings. The work shall include preparation of reinforcement surface, ensuring electrical continuity, fixing of anodes using conductive connectors, testing of installed system, and submission of relevant documentation. The rate shall include the cost of all materials, consumables, labour, tools, scaffolding/working platform, equipment, and all incidental charges, complete as directed by the Engineer-in-Charge. |
| 14 | PROVISION OF ANTICORROSIVE TREATMENT TO OLD AND NEW REINFORCEMENT: Providing and applying two coats of zinc-rich epoxy primer (such as NITOZINC Primer or approved equivalent) on old and new reinforcement after thorough surface preparation, including removal of rust, scale, and other impurities by mechanical wire brushing or sand blasting, as directed by the Engineer-in-Charge. The primer shall be epoxy-based, two-component, zinc-rich, conforming to relevant standards, and applied to achieve a minimum total DFT of 80 microns (40 microns per coat) to ensure galvanic protection and uniform coverage. The rate includes cost of all materials, consumables, tools and tackles, equipment, labour, scaffolding/working platform, surface preparation, and all incidental charges, complete as per specification and direction of the Engineer-in-Charge.Note: Consider Anti corrosive Treatment for Existing Reinforcements as 50% of Proposed additional reinforcement quantity. |
| 15 | PROVISION OF EPOXY BONDING AGENT: Providing and applying epoxy bonding agent such as NITOBOND EP or approved equivalent over the prepared concrete surface prior to placing micro concrete or fresh concrete to ensure monolithic bonding between old and new concrete surfaces. The work includes surface preparation by mechanical cleaning to remove laitance, grease, and loose particles, mixing of base and hardener components using a slow-speed heavy-duty drill (400–600 RPM) for uniform consistency, and uniform brush or roller application immediately before concreting.The rate includes cost of all materials, consumables, tools and plants, mixing and application equipment, hire charges of machinery, labour, scaffolding, safety appliances, and all incidental charges, complete as per specification and direction of the Engineer-in-Charge. |
| 16 | FORM WORK: Description:Providing and fixing slurry-tight formwork of required shape and profile using steel sheets or marine-grade plywood, suitably stiffened with angles or channels to withstand grout pressure. Includes surface coating with mould release agent, proper alignment, bracing, staging, provision for grout ports, sealing of joints, and removal after curing. Rate includes all materials, hire charges of barge/pontoon, scaffolding, labour including divers, tools, and incidental charges, complete as directed by the Engineer-in-Charge. |
| 17 | SELF COMPACTING CONCRETE OF M40 GRADE (THICKNESS 100–125 MM): Providing and placing self-compacting micro-concrete of M40 grade using RENDROC RG (or approved equivalent) mixed with 12 mm down-graded chips (1:0.5–0.75 by weight) and water as per manufacturer’s recommendation. Mixing to be done mechanically and poured continuously through PVC tremie pipes to ensure dense, non-segregated flow. Includes supply of all materials, mixing, placing, curing, hire charges of barges, pontoons, boats, mixers, compressors, diving equipment, labour including divers, and all incidental and safety arrangements, complete as per specification and direction of Engineer-in-Charge. |
| 18 | MEMBRANE CURING AGENT:Providing and applying membrane-forming curing compound (NITOBOND AR or approved equivalent) diluted with water in 1:1 ratio over exposed concrete surfaces immediately after removal of formwork or completion of repair works, using low-pressure spray equipment to form a continuous film ensuring proper curing. Includes cost of materials, labour, tools, spraying equipment, scaffolding, and all incidental charges, complete as per specification and direction of Engineer-in-Charge. |
| 19 | PROTECTIVE COATING USING MCU SYSTEM: Providing and applying protective coating to exposed RCC and steel members such as short columns, diagonal bracings, deck beams, deck slabs, and caisson walls (inter-tidal zone) using MCU coating system comprising two coats of MCU-Miomastic (moisture-cured polyurea primer/intermediate coat) and one coat of MCU-Topcoat, applied as per manufacturer’s specification and during low-tide conditions. Includes surface preparation, materials, consumables, scaffolding, hire charges for boats and machineries, labour, and all incidental expenses, complete as directed by the Engineer-in-Charge. |
| 20 | CORROSION MONITORING BOX: Supplying and fixing corrosion monitoring box as per manufacturer’s specifications for monitoring corrosion activity in selected structural members at designated locations, including provision of all electrodes, sensors, connectors, wiring, instrumentation, and protective housing, complete as per specification and direction of the Engineer-in-Charge. The rate includes cost of all materials, labour, equipment, transportation, hire charges of boats, pontoons, fuel, and all incidental charges, complete. |
| 21 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, bufing, polishing andmakingcurvature(wherever required)andfittingthesame with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 22 | CONDUCTING NDT POST REPAIR SURVEY: Conducting Half-Cell Potential and Ultrasonic Pulse Velocity (UPV) tests on selected structural members such as short columns, diagonal bracings, deck beams, and deck slabs at specified locations in multiple sequences, as per relevant standards.Including cost of instruments, calibration, data recording, report preparation, hire of boat/pontoon, labour, and all incidental charges, complete as directed by the Departmental Officers. |
| 23 | Post Repair Survey |
| 24 | After 6 Months |
| 25 | After 1 Year |
| 26 | After 1 ½ Years |
| 27 | After 2 Years |
| 28 | After 2 ½ years |
| 29 | After 3 Years |
| 30 | After 3 ½ Years |
| 31 | After 4 Years |
| 32 | After 4 ½ Years |
| 33 | After 5 Years |
| 34 | STRENGTHENING OF THE CANTILIVER PORTION OF THE BRIDGE :Providing and fixing additional structural supports consisting of ISMB 450 sections placed in transverse direction with 16 mm thick base plates (600 mm × 250 mm) and ISMB 250 sections placed in longitudinal direction with 10 mm thick plates throughout the walkway length for micro-concrete seating, including supplying all structural steel sections and plates, cutting, fabrication, drilling, welding, bolting, alignment, erection with necessary lifting arrangements, provision of temporary supports, staging, testing and alignment, and dismantling of temporary works; including all labour, materials, tools and plant, equipment hire, transportation and disposal of debris, complete as directed by the Engineer-in-Charge. |
| 35 | PROTECTIVE COATING ON STRENGTHENING WORKS FOR THE CANTILEVER PORTION OF THE BRIDGE BY MCU SYSTEM: Providing and applying protective coating on the RCC cantilever slab using MCU coating system, consisting of one coat of MCU-Miozink 100 microns, two coats of MCU-Miomastic 75 microns (moisture-cured polyurea primer/intermediate coats), and one coat of MCU-Topcoat 75 microns, applied strictly as per the manufacturer’s specifications and during low-tide working conditions; including surface preparation, cleaning, materials, consumables, scaffolding, staging, hire charges for boats and machinery, labour, tools and plants, and all incidental charges, complete as directed by the Engineer-in-Charge. |
| 36 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. |
| 37 | All kind of soil |
| 38 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 39 | All kind of soil |
| 40 | Extra rates (%) for quantities of works, executed: Note for item no. 2.24:- The extra percentage rate is applicable in respect of each item but limited to quantities of work executed in these dificult conditions. The unit, namely, metre depth, to be considered for payment, shall be the depth measured from the sub soil water level up to the centre of gravity of the qty executed in dificult conditions. The depth shall be reckoned correct to 0.10 m, 0.05 m or more shall be taken as 0.10 m and less than 0.05 m ignored. |
| 41 | In or under water and/or liquid mud, including pumping out water as required |
| 42 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lif. |
| 43 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 44 | 1:2:4 (1Cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 45 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor fivelevel,excludingcost of centering,shuttering, finishingand reinforcement: |
| 46 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 47 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 48 | Foundations,footings,basesof columns,etc.formass concrete |
| 49 | Walls (anythickness)includingattachedpilasters, butteresses, plinth and string courses etc. |
| 50 | Extra for shutteringincircular work (20%of respective centering and shuttering items) |
| 51 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. |
| 52 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 53 | Collection, carriageand filling of stone boulder as filter media on rear side of the walls as per the direction of Engineer-in-Charge. |
| 54 | Supplying of PVC insulated and PVC sheathed aluminium conductorarmoured XLPE power cable of 1.1KV grade of following sizes etc as required.Make; Havells or equivalent in Polycab/Finolex/RR cables /Anchor |
| 55 | 4 Core x 25 Sqmm |
| 56 | Supplying and laying offollowing size DWC HDPE PIPE along with all accessories like socket, couplers etc confirming to IS: 14930 PART- II Complete with necessary HDPE fittigs for protection of 1.1 KV grade on surface etc as required. |
| 57 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 58 | Supplying and laying of following sizeDWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc. conforming toIS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 59 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 60 | Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required |
| 61 | 80 mm dia |
| 62 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 63 | Above 35 sq.mm and upto 95 sq.mm |
| 64 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 65 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 66 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required. |
| 67 | 4 X 25 sq. mm (28mm) |
| 68 | Supplying of 200W LED Flood light fittings best in class lens design & optical integration is a flood lighting luminarie with single die ceramic base highpower LED PDC housing & integrated flood optics (SWB, NB, AMB, SMB, SWB) to ensure unifrom distribution maintenance free system, ideal for ports lighting area lighting and high mast lighting Make :- PhilipsTango LED Cat.No. BVP483 LED210 CW SWBPSU GRor equivalent in Bajaj/Crompton/Havells complete with all accessories etc as required. |
| 69 | Installation, testing and commissioning of LED flood light fittings including connection etc as required. |
| 70 | Providing and fixing out door feeder box made of 18 SWG CRC sheetof size 1.5 Mtrs x 1.00 Mtrs x 0.5 Mtrs welded construction with sloping roof and double leaf type hinged door at frontwith locking arrangementinstalled on25mm x 25mm x 3mm M.S. Angle of length 1.00 Mtr eachand25mm x 6mm M.S. Flat suitable for mounting 250A four pole 35 kA breaking capacity MCCB01 No. for INCOMING with aluminium bus bar of suitable size and OUTGOING with 100A four pole 25 kA breaking capacity MCCB03 Nos. including connection, paintingetc as required. |
| 71 | Fabrication of 7 Mtrs GI Octagonal pole part as per dimension top dia-70mm, Bottom Dia 130mm, section-1(section length-7000mm ) thickness-3mm, base plate-225mm x 225mm x 12mm, standard single arm bracket of length 1000mm, foundationbolts set of M20 x 700mm includingsintex box of size insidedimension 140mmx140mmx95mm GSJB 1414 containing 1 No. MCB 6A includingFRLS PVC insulated copper cable 1.5 Sqmm,painting & connectionetc as required |
| 72 | Supplying Hybrid AIO Gen 2 powerd by solar energy and at the same time connected to the electric grid in case of abundant sunlighat, it uses solar energy and otherwise Make:- Philips CaT.No. BRP 111 LED 120/757 M Solar HY or equivalent in reputed make. |