| 1 | Repair and maintenance of street light, perimeter light, security light, flood light, post top light, bollard light fitting any type and make, junction box connection including MCB, MCCB, street light timer connection, cable to overhead lines, overhead conductor jumper and other connected items of street light of any type and any capacity fixed in any position i.e. on wall/pole/gate/garden/watch tower/High mast for repairing in presence of MES rep to ascertain defective parts of the fitting and preparing list of defective parts to be replaced for making the fitting fully functional testing and re fixing the fitting etc in its originalposition after repairs and keep the light fitting working condition complete all as specified & directed. Notes :-(a) Contractor will depute daily two Nos electrician with T&P in MES office/complain cell for received of the complaint and rectified the same. In case of absence of any electrician the penalty @ Rs 100.00 per day per electricians shall be imposed on the contractor. (b) The rate inclusive all the T&P i.e ladder, Veh required for execution of works shall be arranged by the contractor included in quoted rate.(c) Any complaint will be measured one time in same location/pole/light during contract period(d)Items required for repair / replacement work will be measured and paid for separately as \"S&F in replacement\". (e) Scope of work includes for minor stores e.g. PVC insulation tapes, screws, insulation sleeves, nuts, bolts, washers etc as required at site included in quoted rate |
| 2 | S&F LED street light fitting 35 Watt, and efficacy > 110 LPW 240 Volts, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover with IP66 protection and impact resistance of IK07 connected with and including 0.5 sqmm flexible copper multistranded conductor cable including fixed on wall / pole and unsl light to be deposited in E&M storeall as specified and directed. Make : Crompton Cat No CRP-409-45-57-SL-GL-NSG, Surya Cat No SLE UL 36W IP66 NGN, Orient Cat No LSFS-045-C or equivalent |
| 3 | S&F LED street light fitting 45 Watt, and All description as per item No 02 above and unsl light to be deposited in E&M store all as specified and directed . Make : Crompton Cat No CRP-409-45-57-SL-GL-NSG, Surya Cat No SLE UL 36W IP66 NGN, Orient Cat No LSFS-045-C or equivalent |
| 4 | S&F LED Street light fitting 60 Watt, and All description as per item No 02 above and unsl light to be deposited in E&M store. all as specified and directed. Make : Crompton Cat No CRP-409-60-57-SL-GL-NSG, Orient Cat Part No LSFS-060-C, Surya Cat No SLE UL 60W IP66 NGN, or equivalent |
| 5 | S&F LED street light fitting 90 Watt, and All description as per item No 02 above and unsl light to be deposited in E&M store all as specified and directed. Make: Crompton Cat Part No CRP-404-90-57-SL-GL-NSG, Surya Cat No SLE UL 90W IP66 NGN, Orient Cat No LSFS-090-C ofor equivalent. |
| 6 | S&FLED flood light fitting 70Watt,230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp 240 Volts, and efficacy_> 110 LPW with accessories, pre-wired upto a terminal block and mounting attachment and unsl light to be deposited in E&M store complete all as specified and directed. Make: Crompton Cat Part No. TFS-504-70-57-60D-SL-GL-NSG, Surya Cat No SLE FL 80W IP66 LMS NEO, Orient Cat No LFSMP-070-C or equivalent |
| 7 | S&FLED flood light fitting 100 Watt, and All description as per item No 06 above and unsl light to be deposited in E&M store all as specified and directed. Make : Crompton Cat Part No. TFS-504-100-57-60D-SL-GL-NSG, Surya Cat No SLE FL 100W IP66 LMS NEO, Orient Cat No LFSMP-100-C or equivalent |
| 8 | S&F LED flood light fitting 120 Watt, and All description as per item No 06 above and unsl light to be deposited in E&M store all as specified and directed. Make: Crompton Cat Part No. TFS-504-120-57-60D-SL-GL-NSG, Orient Cat Part No. LFSMP-120-C, Surya Cat No SLE FL 120W IP66 LMS NEO or equivalent |
| 9 | S&F in replacement Post top LED lantern 40 Watt complete, 230 V AC outdoor type with decorative post for 360 degree indirect light IP-65 protection and efficacy > 110 LPW 240 Volts with impact and corrosion resistant complete with driver and LED lamp all as specified & as directed.Make: Crompton Cat Part No. CBP-610-40-57-SL-CA-NBK, Havells Cat Part No. RUBYPT40WLED757PSYMTOPC, Orient Cat Part No. LLOP-45-C Surya Cat No SLE PT 40W ETPP or equivalent |
| 10 | S&F in Replacement Post top LED lantern 20 Watt complete, 230 V AC outdoor type with decorative post for 360 degree indirect light IP-65 protection and efficacy > 110 LPW 240 Volts with impact and corrosion resistant complete with driver and LED lamp all as specified & as directed. Make Crompton Cat Part No. LPTH-20-CDL, Havells Cat Part No. RUBYPT25WLED830 SSYMTOPC, Orient Cat Part No. LLAS-20-C, Surya Cat No SLE PT 30W ETPP or equivalent |
| 11 | S&F in replacement LED drivers suitable for capacity 30 to 100 watt andany make street light complete all as specified and directed. |
| 12 | S&F in replacement surge protection device 10 KV for LEDlight fitting complete all as specified & directed. |
| 13 | S&F in replacement street light bracket made to shape out of GI pipe 40 mm bore light grade, 1.5 meter length fixed with & including necessary MS Clamps of size 40x5mm includingnuts, bolts and washers on poleetc complete all as specified and directed. |
| 14 | S&F in replacement 20mm rigid non-metallic PVC conduit inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, locknuts, saddles, pipe hooks etc. complete all as specified & directed. |
| 15 | S&F in replacement FRLS PVC insulated and PVC sheathed 1.5 sqmm 3 core multistranded copper conductor cable from for street light including PVC wire connectors for making connection complete all as specified and directed. |
| 16 | Prunning / trimming the branches of trees if any along overhead line, 3 mtr on all side below/ above/ sides of overhead line and removing the same upto 150 mtr away each span not exceeding 70 mtr etc complete all as specified and directed.Note :- The above is to be ensured for the entire contract period by cutting/trimming of trees any number of times as required. |
| 17 | M&L for preparation of old painted surface of steel tubular LT poles 9m/11m long and applying two coats of synthetic enamel paint with black and white or yellow strips 30cm wide each upto 1.5m height from top of PCC foundation block and on remaining surface of steel pole applying one coat of aluminium paint after preparation of old steel surfaces including marking of numbering of poles with synthetic enamel paint white in colour in 80mm high letters over 150mm x 230mm yellow base and applying one coat of cement base paint on PCC pedestal complete all as specified and directed. |
| 18 | Labour only for disconnecting, taking out defective under ground LT cable of length not more than3 meter and of size 10 sqmm to 25 sqmm including excavation, taking out bricks cover andrelaying the old cable in loopand making connection with proper newthimbles with cut out boxes,Feeder pillar box, MCBs etc including refillingofsand, relaying old bricksand returning, filling in soil etc complete all as specified and directed. |
| 19 | S&F in replacement PVC junction box suitable for street light of size not less than internal dimention 300mm x 250mm x 150mm, made out of polycarbonate having front side openable shutter duly provided with locking arrangement and provided with 04 Nos aluminium bus bar of rating 32 Amp alongwith 01 No MCB 6 Amp SP and provision of 04 Nos cable entries, fixed on street light pole with proper size MS clamp with nut & bolt and connected assessories complete all as specified and directed. |
| 20 | Re-stringing / Re-stretchingincluding jointing in situ of each span not more than 45 Mtrs between two electric poleshaving 3 to 5 Nos of ACSR conductors including GI earth continuity wire, with/ withoutguarding wires onelectric poles of any size at different locations all as ordered manually or by telephonically means to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete as ordered. |
| 21 | Taking out the old unserviceable LT underground cable upto 16 Sqmm 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors from trenches/wall/floor/road/ culverts or pole etc including brick cover complete all as specified and directed.Note : Excavation and earth work, duct work, GI pipe for laying of cable and sand cushing/cable protection covers etc are beyond the scope of this item and shall be measured & paid for separately under relevant items of BoQ. |
| 22 | Supply , laying,jointing, testing and commissioningof size 6 sqmm 4 core LT UG cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified and directed.Note : Excavation, earth work, sand cushion & brick protection shall be paid separately. |
| 23 | All as per item No 22 above but of size 10 Sqmm 4 core |
| 24 | All as per item No 22 above but of size 16 Sqmm 4 core |
| 25 | S&F in replacement twin core flat 6 Sqmm size 1100 volt grade heavy duty cable PVC insulated with aluminum solid conductor over all PVC sheathed complete all as specified and directed. |
| 26 | S&F in replacement twin core flat 10 Sqmm size 1100 volt grade heavy duty cable PVC insulated with aluminum solid conductor over all PVC sheathed complete all as specified and directed. |
| 27 | S&F in replacement twin core flat 16 Sqmm size 1100 volt grade heavy duty cable PVC insulated with aluminum solid conductor over all PVC sheathed complete all as specified and directed. |
| 28 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 m deep in soft/loose soil for laying of cables, GI pipe or filling of earth resistance enhance compound and getting out including levelling of bottom suface to required level complete all as specified and directed |
| 29 | Supply and laying double wall corrugated (DWC) pipeconforming to IS 19430 Part - I of size 50mm outer dia and 38 mm inner dia complete all as specified and as directed |
| 30 | Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified. |
| 31 | Removing excavated material (ie soil) from site to a distance n. exc 50 m away and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed |
| 32 | Returning filling in including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and as directed. |
| 33 | S&F in replacement MCBSPN of capacity 6A to 32A , 10 KA, type \"C\", 240 volts complete all as specified and directed. |
| 34 | S&F in replacement MCB TPN of capacity 40A to 100A,10 KA, type \"C\",240 volts complete all as specified and directed. |
| 35 | Supply & fixing nature switch panel ( using infra Red sensor technology ) based automatic street light control. The panel should be suitable enough to take three load of 5 kW with 3 Nos contactors, 3 Nos incoming MCB & 3 Nos outgoing MCB of rating 20-25 Amps & main load circuit wiring of 10sqmm. The system should be enclosed in IP 54 enclosure with angle frame to mount on it with PCC foundation complete all as specified and directed. Make: Healer enterprises/BHUPAL digital timer/ Legrand |
| 36 | Supply, install, testing and commissioning of LT Feeder pillar distribution panel board CPRI approved outdoor type, horizontal type, double door system, weather proof, dust and vermin proof, made out of 40x40x6mm angle iron frame and 3.15mm thick CRCA sheet duly powder coated of suitable size with push type locking arrangement, factory assembled cubicle pattern modular and compartmentalized construction, floor mounted free standing type, 3 phase 4 wire system including wiring with suitable size rated current carrying capacity aluiminium bus bar with epoxy insulated coating with colour code and insulated support, complete with following accessories and suitable for accomodate the following MCB\"s etc complete and mounting the panel board on ground with PCC(1:3:6) bedding upto height of 30 cm above ground level complete all as specified and as directed(a)150 Amps aluminium bus bar for all three phases and 100 Amps for neutral - 01 set.(b) MCB 63A TPN as incoming - 01 No(c) MCB SPN 32 upto 05 Nos(d) Internal All links with copper conductor or solid aluminum bus bar of adequate capacity -01 |
| 37 | S&F in replacement GI tubing, 40mm bore light grade, ISImarked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately. |
| 38 | Dismantling unserviceable concrete pole/struts of any size removing from site etc complete all as specified and directed. |
| 39 | Supply, erecting & fixing true vertical position pre-stressed concrete pole conforming to IS-1678 of9 mtr long, 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class 10 etc complete all as specified and directed.Note :- (i)The rates quoted shall deemed to include taking out conductors, earth wire from existing pole and refixing on new pole.(ii)Earth work & PCC shall be measured and paid separately in respective items. |
| 40 | Dismantling insulator any type / any size from LT pole etccomplete, all as directed. |
| 41 | Supply and fixing pin type insulators LT 1100 Volts grade porcelain vitreous white or brown including one galvanized mild steel spindle, two galvanized iron washers, one galvanised iron nut, 100 mm height, 65 mm diaall as specified and directed. |
| 42 | Supply & fixing shackle type insulator LT 1100 volt grade porcelain vitreous white or brown including galvanised insulator bolts, nuts 12 mm dia and washer including 31x3mm galvanised mild steel straps, 75 mm height and 90 mm dia of insulator complete all as specified and directed. |
| 43 | M/L for Demolition of path /concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) .complete all as specified and as directed. |
| 44 | M/L for cement concrete type B-2, 1:2:4 (40mm graded aggregate) 150mm thick complete all as specified and as directed. |
| 45 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 40mm dia complete Note :- GI pipe shall be measured and paid separately |
| 46 | M&L for PCC (1:4:8) type D-2 using 40 mm crushed graded stone aggregate as in for pole foundations etc complete all as specified and directed. |
| 47 | M&L for PCC (1:2:4) type B-1 using 20 mm crushed graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles etc for poles complete all as specified and directed. |
| 48 | S&F in replacement of MCCBs of capacity100 Amps, FP, 25 KA, 415 Volts 50 Hz, AC, with adjustablethermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as directed |
| 49 | Description all as per ser item No 48 above but rating of MCCB63 Amp, 16 KA |