| 1 | Taking down carefully Window Type / Split Type / Cassate Type Air Conditioner 1.50 / 2.00 Ton capacity, from its location and removing dirt and dust from Indoor and outdoorunit of the Air Conditioner and washing the condensor and evaporator with varmi clean solution and other areas by soapsolution, spraying pressurised water on condensor and evaportor with proper protection of electrical fixtures and connection, drying by blowing air, andInstalling and testingin same positionWindow Type / Split Type / Cassate Type Air Conditioner complete all asdirected by Engr-in-Charge. |
| 2 | Taking down unserviceable Rotary/reciprocatory Compressor from Air Conditioner Window Type / Split type 1.5 Ton capacity of any make & type and Supply and Fixing NewRotary Compressorincluding startingrelay assembly withOver Load Protectorof air conditioner ofwindow Type / Split type 1.5 Ton capacity along with newfoundation rubber pads, nut and bolts including testing on full loadcomplete all as directed by Engineer-in-Charge.Make : Hitachi / Tecumseh / GMCC/copeland/LG.Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. |
| 3 | All as per serial item No. 02 above but for air conditioner ofwindow Type / Split type 2.0 Ton capacity. Make : Hitachi / Tecumseh / GMCC/Copeland/LG.Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. |
| 4 | S&F in repair Fan motor suitable for Window Type/ Split type Air Conditioner outdoor unit of capacity 1.5 Ton / 2.0 Toncomplete all as directed. |
| 5 | S&F in repair Fan Blade suitable for Window Type/ SplitType Air Conditioner outdoor unit of capacity 1.5 Ton / 2.0 Ton complete all as directed. |
| 6 | S&F in repair Running/starting Capacitor for Air Conditioner compresser of any make and model for 1.5/2 Ton window/split AC compressor complete all as directed by Eng-in-Charge.Make : EPCOS / ASIAN / SIEMENS/Havells/Tibcon |
| 7 | S&F in repair Running/starting Capacitor for Air Conditioner fan motor of any make and model for 1.5/2 Ton window/split AC complete all as directed by Eng-in-Charge.Make : EPCOS / ASIAN / SIEMENS/Havells/Tibcon |
| 8 | S&F in repair Thermostat Switch with knob suitable for Window Type Air Conditioner of any type and capacity complete all as directed by Engineer-in-charge. |
| 9 | S&F in repair Plastic Front Grill assembly alongwith PVC filter complete suitable for any make of window type 1.5 / 2.0 tone Air Conditioner complete all as directed by Engineer-in-charge. |
| 10 | S&F in repair Condensor cooling coil made out of copper tubing and fins at appropriate spacing complete in all respects suitable for Window Type / Split type Air Conditioner of capacity 1.5 Ton including brazing/welding etc. complete all as directed by Engineer-in-charge. Make : LG/Sansui/Voltas/hitachiNote:(i) Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. (ii) Cost of newfoundation rubber pads, nut and bolts including testing on full loadcomplete is icluded in this item |
| 11 | S&F in repairEvaporator cooling coil made out of copper tubing and fins at appropriate spacing complete in all respects suitable for Window Type / Split type Air Conditioner of capacity 1.5 Ton including brazing/welding etc. complete all as directed by Engineer-in-charge. Make : LG/Sansui/Voltas/hitachiNote:(i) Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. (ii) Cost of newfoundation rubber pads, nut and bolts including testing on full loadcomplete is icluded in this item |
| 12 | All as per serial item No. 10.00 above butfor Window Type / Split type Air Conditioner of capacity2.00 Ton. |
| 13 | All as per serial item No. 11.00 above butfor Window Type / Split type Air Conditioner of capacity2.00 Ton. |
| 14 | M&L for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and gas charging by R-22/R-134/R-32/R-410/R-600 upto the required pressure for 1.5 / 2.0 Ton Window Type / Split TypeAir Conditioner complete all as approved and directed by Engineer-in-charge.Note :- (i)The cost ofgas is included in this item and nothing extra shall be paid on this account.(ii) The cost of capillary/drier/flare nut if required is included in this item item and nothing will be paid extra on this account |
| 15 | S&F in repair PCB including Remote Control for remote sensing and operation suitable for Window Type/ Split Type Air Conditioner 1.5 Ton/ 2.0 Ton make as approved by Engineer-in-charge. |
| 16 | S&F in repair invertor PCB including remote control for remote sensing and operation suitable for window / split type (indoor and outdoor complete)air conditioner1.5/2.0 ton make as approved by Engineer-in-charge. |
| 17 | S&F in replacement of indoor unit kit 3 star rated with complete fittings like copper coil, temperature display, blower motor, PCB etc suitable for existing 1.5 ton capacity Split type Air conditioner complete all as specified and directed. |
| 18 | &F in replacement of outdoor unit kit suitbale 3 star rated ODU with complete fittings like condenser assembly, fan motor, suitable for existing 1.5 ton capacity Split type Air conditioner complete all as specified and directed by Engg-in-charge. |
| 19 | S&F in repair Metal clad Earth plug 20 A 2pin and earth, 230V AC complete all as directed.. |
| 20 | S&F in repair Metal clad Earth Socket 20 A 2pin and earth, 230V AC complete all as directed. |
| 21 | Providing labour only for attending complaints and removing of split type AC/Water Coolers/Refrigerators/Deep Freezer/any summer applianceslocating at ground floor / first floor /second floor/ third floor installed in Messes,offices/ Labs /Bldgs at any locationof Hisar cantt and placing at its original position after repairingthecomplaintscomplete all as directed by Engr-in-Charge.Note ;- (i) The spares required for repairing the compalints shall be measured and paid sepertely under respective items. (ii) Contractor will appoint 01 Technician and 01 helperin the AGE E/M Sub Division for attending the complaints and supply and fixing items.(iii) Contractor will provide complaint register and complaint slip for Complaint record. (iv) Contractor will stick sticker of GE Hisar of minimum size 30mm width x 80mm length on Complaint equiment . |
| 22 | Taking out unserviceable Blower motor from the indoor unit split TypeAir Conditionerof any make / type / capacity and supply and fixing new Blower motor of same make / type / capacity including nut and bolts if required complete all as directed by Engr-in-Charge. |
| 23 | S&F in repair PVCinsulated three core multi stranded copper conductor, 2.5 sq.mm, as in wiring including connecting up and testing complete all as directed by Engineer-in- charge . |
| 24 | Disconnecting, taking down and Shifting Air Conditioner, Window Type/ Split Type up to 2 TR from existing location and fixing in other location and installing, connecting up and testing complete all as directed. Note: (i) Cost of gas charging and making surface good if required is included in this item and nothing will be paid extra on this account.(ii) Cost of copper piping and drain pipe if required will be paid under appropriate item of schedule. |
| 25 | S&F in repair Copper tube, 15 mm / 18 mm dia, superior quality suitable for refrigeration and suction lines of split ACs, and copper tube9 mm diadischarge line drawn trough pipes / fixed to walls / laid on floor or roof complete all as directed by Engineer-in- Charge.Note : (i) Copper tube, 15 mm / 18 mm dia and copper tube 9mm diadischarge line -1.00 Running Metre bothcopper tubes shall be measured and paid in single lengthPer Running Metre.(ii) Contractor will make surface good at its own cost during currency of work |
| 26 | S&F in repair MCB SP 20 to 32 A \"C\" curvecomplete all as directed. |
| 27 | Material and labour for taking down PCB including remote sensing unit for window/Split type AC of capacity 1.5TR/2TR and doing necessary repair/fixing electronic circuit complete and making it fully functional and testing it full load complete all as specified and directed by Engg-in-Charge. |
| 28 | Supply and Fixing in replacementold unservicable chassis body unit made out of MS sheet suitable for 1.5 Ton Window Type Air Conditinor with remote sensing system complete , duly spray paintedwith two coats of synthietic enamel paintcolour (shade of colour as approved by Engineer-in- Charge) , including heavy duty copper tubing and copper fins evaporator coil, condenser coil ,copper wounded fan motor, blower and fan blade and suitable front grill etc. complete all as directed by Engineer-in-charge. Make and sample as approved by Engineer-in- Charge. |
| 29 | Disconnecting the electrical and water connections of desert cooler and taking down from its position installed at any floor of the building, opening the side pannels and remove the unserviceable/dirty wood wool pad/ khas khas pad, dismantled the front grill including piano type swiches, regulators, rotary switches, etc. Scratching out the old paint from inner and outer surfaces of cooler with sand emery paperand cleaning to make smooth surface and painting the inner side of the body with two coats of anticorrosive black paint and outer surface with two coats of silver ash hammerton paint with spray gun machine with office name including painting the air direction change grill and fixing the desert cooler and its parts complete as original and at original place including making water and electrical connection, fixing khas khas grass pad set and testing etc complete all as directed by Engineer-in-Charge. Note : The spares required for repairingshall be measured and paid sepertely as supply only under respective items. |
| 30 | S&F in replacement New fan motor of copper winding 1/6 HP single phase 230v three speedcomplete all as specified & directed. |
| 31 | S&F in replacement Desert cooler air direction changing front grill complete heavy duty having minium weight 3kg made out of GI sheet including fixing plate complete all as specified & directed |
| 32 | Supply and fixingPVC connection pipe 450 mm long and 15mm dia with PTMT nuts including PVC washer complete all as directed by Engineer-in-Charge. |
| 33 | Supply and fixingcapacitor 4 mfd complete all asdirected by Engineer-in-Charge. . |
| 34 | Supply and fixing PVC distributor three way superior quality complete all as specified and as directed by Engineer-in-Charge.Make and sample as approved by Engineeer-in-Charge. |
| 35 | Supply and fixingPVC Eblow superior quality suitable for desert cooler of any capacity complete all asdirected by Engineer-in-Charge. |
| 36 | Supply only PVC flexible pipe minimum 15mm bore superior quality heavy duty suitable for desert cooler of any capacity complete all asdirected by Engineer-in-Charge. |
| 37 | S&F in repairwater pump for desert coolers 230 Volts, 50 Hz speed not less then 1300 RPM includingnut and bolts complete all asdirected by Engineer-in-Charge. |
| 38 | Taking down usserviceable fan motor includingfan blade ,MS legs and rubber pads from the desert cooler including supply and fixingMS legs (set of four) and rubber pads complete all as directed by Engineer-in-Charge. |
| 39 | Supply onlywood wool pads (Set of three) weight not less than 500gms superior quality complete all asdirected by Engineer-in-Charge. |
| 40 | S&F in replacement of complete GI body of desert cooler of capacity 5000 CFM with min tank capacity of 100 ltr duly painted with two coats of synthetic enamel paint hammer tone paint over a coat of red oxide primer externally and one coat of anti-corrosive paint internally complete all as specified & directed.. The body of desert cooler shall be fabricated as under:- (a) Top and bottom shall be made out of 1.25mm thick GI sheet.(b)Side Panels shall be made of 1mm thick GI sheet.(c)Breadth and width size should not be less than 26 inch.(d)Height of Cooler should not be less than 42 inch (including tank height )GE Hisar should e painted in front of cooler and size of word together should not be less than 1 feet length wise and 40mm breadth wise |
| 41 | S&F in repair aluminium fan blade 21\" dia suitable for desert cooler any make and any type complete all asdirected by Engineer-in-Charge. |
| 42 | S&F in repairply wood board of size 8\" x 4\"12mm thich in cut sizes as required at site for desert cooler with and including support for fixing of ply wood including painting with one coats of synthetic enamel paint over a coat of pink primer complete all asdirected by Engineer-in-Charge. |
| 43 | S&F in repairpiano switch, flush type 5 Amp, 240 Volts, single pole, one way complete all as directed by Engineer-in-Charge. |
| 44 | S&F in repairrotary switch regulator with PVC knob single pole to operate cooler 5 Amp, 240 Volts, single phase including testing and commissioning complete all asdirected by Engineer-in-Charge. |
| 45 | S&F in repair PVC float valves, high pressure, with polythene float and fly-nut (PTMT) complete,screwed for iron pipe of brass ferrule, suitable for Desert cooler of size 15mm bore pipe complete all as specified and as directed by Engineer-in-Charge. |
| 46 | S&F in repair3 pin, 5 Amp top plug, 240 Volts, single phase complete all as specified and as directed by Engineer-in-Charge. |
| 47 | S&F in repaircopper cable 3 core round of size 23/0.0076 ,2.5 Mtr long with 5 Amp top plug including making connection all as specified and as directed by Engineer-in-Charge. |
| 48 | M&F for repairs of automatic voltage stabilizer of any make for 4 to 5 KVA capacity by dismantling and taking out old cabinet and replace it with new cabinet of same size incl varnishing, cleaning, servicing, tighteningof loose connection/ joints of all the controls/components to make the voltage stabilizer in serviceable condition complete. Note :- Any component/control if replaced shall be measured & paid separately. |
| 49 | M&F for repairs of automatic voltage stabilizer of any make for 2 to 3 KVA capacity by dismantling and taking outold cabinet and replace it with new cabinet of same sizeincl varnishing, cleaning, servicing, tighteningof loose connection/ joints of all the controls/components to make the voltage stabilizer in serviceable condition complete. Note :- Any component/control if replaced shall be measured & paid separately. |
| 50 | S&F in replacement of main transformer of 4 to 5 KVA capacity voltage stabilizer complete. |
| 51 | S&F in replacement of main transformer of 2 to 3 KVA capacity voltage stabilizer complete. |
| 52 | S&F in replacement of relay assembly suitable for single phase 2 to 5 KVA capacity voltage stabilizer complete. |
| 53 | S&F in replacement of volt meter 0-300 volts, square/dial or digitaltype as per existing voltage stablizer all as specified and directed by Engg-in-charge. |
| 54 | S&F in replacement of time relay suitable for 2 to 5 KVA capacity voltage stabilizer complete all as specified and directed. |
| 55 | S&F in replacement of electronic printed control card suitable for any make of capacity 2 to 5 KVA voltage stabilizer complete all as specified and directed. |
| 56 | S&Fsheet metal enclosure Single pole and neutral with a two pin and earth plug and socket complete with and including one 20 Amp SPN MCB\"C\" curve complete all as specified. |
| 57 | S&F in repair TK foam heat insulation tube of size 1/2 inch x 3/8 inch (inner dia x thickness) for AC piping hot and cold duly covered with EBP heavy duty high bond insulation tape heat resistant tapecomplete all as directed by Engineer-in-Charge. |
| 58 | S&F in repair TK foam heat insulation tube of size 1/4 inch x 3/8 inch (inner dia x thickness) for AC piping hot and cold duly covered with EBP heavy duty high bond insulation tape heat resistant tapecomplete all as directed by Engineer-in-Charge. |
| 59 | Supply and fix in repair heavy duty outdoor stand suitable for capacity of 1.5/2TR mountable on wall or horizontal place made out of GI steel and can bear 160 kg load all as specified and directed by Engg-in-Charge.Note:- (i) cost of all clamps,nut, bolts etc is included in this item and nothing shall be paid extra on this account.(ii) Contractor will make surface good at its own cost during currency of work |
| 60 | Opening and removing the Compressor, Condensor coil of the Refrigeratorof any capacity of any make, cutting the rusty unserviceable lower portion of the body cover including supply, fabrication and fixing the lower portion made out of MS sheet as per original size and shape, reassembling the refrigerator, scratching out the old paint with emery paper and making the surface smooth and applying two coats of synthetic enamel paint of original shade / coulor on full body of refrigerator by using spray gun and applying anti corrosive black paint with spray maching to compressor and condenser coil complete all as directed. |
| 61 | Servicing of Refrigerator 165 to 350 litres capacity including cleaning with vermin clean solution complete and checking of electrical connections etc. as in preventive maintenance complete all as directed. |
| 62 | All as per serial item No. 61.00 above but for Deep Freezer of Capacity 200 to 400 litres all as specified and directed. |
| 63 | S&F in repairCompressor (sealed unit ) of refrigeratorof capacity 160 / 175 / 220 ltrs AC 230 Volts single phase refrigratorprocured directly from manufacturer or authorised dealer alongwith test certificate from the manufacturer (with Two years guarantee) including startingrelay assembly withOver Load Protector , commissioning and testing on full load of compressor including supply and charging of refrigerant gas in the system its rated capacity and including replacement of copper filter single capilary complete all as directed. |
| 64 | All as per serial item No 63.00 above but for Refrigerator of (any make) of capacity 286 / 310 / 350 ltrs capacity . |
| 65 | All as per serial item No 63.00 above but forDeep Freezer of (any make) of capacity 250 / 300 / 350/400 ltrs capacity. |
| 66 | All as per serial item No 63.00 above but for Refrigerator Invertor type technolgy of capacity 160 / 175 / 220 ltrs of any make and type.Make ; LG / Whirlpool / Godrej/ Copeland |
| 67 | All as per serial item No 63.00 above but for Refrigerator Invertor type technolgy of capacity 286 / 310 /350 ltrs of any make and type.Make ; LG / Whirlpool / Godrej/ CopelandNote for serial item No. 63 and 67.00:(i) The rate of Supply and Fixing of NewCompressor of suitable capacity,startingrelay assembly withOver Load Protectoris inclueded in this item and nothing shall be paid extra on this account.(ii) The rate of Supply and charging of Gas is not included in this item and will be paid under appropiate item of schedule.(iii)The unit rate quoted by the contrcator also includes cost ofreplacement offoundation rubber bushes, nuts, and bolts , necessary electrical connection for making the appliances functional and cleaning of condenser etc.and nothing shall be paid extra on this account. |
| 68 | Material and Labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and charging R-22/R-134/R-32/R-410/R-600 suitable gas for Referigerator/Deep Freezer/Water Cooler upto the required pressure complete all as approved and directed.Note :- (i)The cost ofgas is included in this item and nothing extra shall be paid on this account.(ii) The cost of capillary/drier/flare nut if required is included in this item item and nothing will be paid extra on this account |
| 69 | S&F in repair Thermostat Switch with knob for any capacity of Refrigerator complete all as directed. |
| 70 | S&F in repair Starting Relay Assembly with Over Load Protector any model. Complete all as directed. |
| 71 | S&F in repair Freezer Door completeincluding Bracket suitable for 165/175 ltrs capacity Refrigerator. |
| 72 | S&f in repair Freezer Door completeincluding bracket suitable for 286 / 310 ltrs capacity Refrigerator. |
| 73 | S&F in repair AluminiumFreezer Shellsuitable for 165/175 ltrs capacity refrigerator. |
| 74 | S&F in repair AluminiumFreezer Shell 286/310/350 ltrs capacity refrigerator . |
| 75 | S&F in repair Plastic Vegetable TrayHeavy duty suitable for Refrigerator165to 280 ltrsof capacityof any make any typecomplete all as directed. |
| 76 | S&F in repair Plastic Vegetable TrayHeavy duty suitable for Refrigerator 286/310/350 ltrs of capacityof any make any typeand as approved by Engineer-in-Charge. |
| 77 | S&F in repairCondenser suitable forRefrigerator 160 to 280 ltrs capacitycomplete all as directed. |
| 78 | S&F in repairCondenser suitable for Refrigerator 286 to 340 ltrs capacity complete all as directed. |
| 79 | S&F in repair Defrost Timer 230 Volts, 50 Hz C/S suitable for single door Refrigerator of 160 / 175 / 220 ltrs capacity of make Whirlpool/LG complete all as directed. |
| 80 | S&F in repair Defrost Timer 230 Volts, 50 Hz C/S suitable for double door Refrigerator of 225 to 340 ltrs capacity of make Whirlpool/LG complete all as directed. |
| 81 | S&F in repair Cooling Fan Motor suitable for Double Door Refrigerator of 225to 340 ltrs capacity and make Whirlpool / LG complete all as directed. |
| 82 | S&F in repairCooling Fan Motor suitable for Deep Freezer 250 to 400 ltrs capacity complete all as directed. |
| 83 | S&F in repairPCB Module 230 Volts, 50 Hz C/S suitable for Single/Double Door inverter Refrigerator of make Whirlpool / LG complete all as directed. |
| 84 | S&F in repair Bimetal 230 Volts, 50 Hz C/S suitable for double door refrigerator of make Whirlpool/LG Make complete all as directed. |
| 85 | Taking out the unserviceable compressor (Sealed unit) from water cooler 40 liters capacity of any make and type and repalacement of new compressor obtained from the factory out let make Copeland/Tecumseh/Whirlpool/LG model KCE 444, AE 4440 YGS including suitable relay, over load and starting/running capacitor, flushing out the old bunt condensite from the gas systemby vacuumisation, cleaning the system by CTC solution, pressure testing of the system, gas charging with R-134 gas upto the desired pressure, testing & commissioning the water cooler complete all as directed. |
| 86 | Taking out the unserviceable compressor (Sealed unit) from water cooler 60/120 liters capacity of any make and type and repalacement of new compressor obtained from the factory out let make Copeland/Tecumseh/Whirlpool/LG model KCE 443, AKR 4460 including suitable relay, over load and starting/running capacitor flushing out the old burnt condensafe from the gas system by vacuumisation, cleaning the system by CTC solution , pressure testing of the system, gas charging with R-134a gas upto the desired pressure, testing & commissioning the water cooler complete all as specified and directed. |
| 87 | Taking out the unserviceable compressor (Sealed unit) from water cooler 150 liters capacity of any make and type and repalacement of new compressor obtained from the factory out let make Copeland/Tecumseh/Whirlpool/LG, model ACJ 513, AW 1000, including suitable relay, over load and starting/running capacitor flushing out the old burnt condensafe from the gas system by vacuumisation, cleaning the system by CTC solution , pressure testing of the system, gas charging with R-134a/22 gas upto the desired pressure, testing & commissioning the water cooler complete all as specified and directed. Note for item 85,to 87(i) The rate of Supply and Fixing of NewCompressor of suitable capacity,startingrelay assembly withOver Load Protectoris inclueded in this item and nothing shall be paid extra on this account.(ii) The rate of Supply and charging of Gas is not included in this item and will be paid under appropiate item of schedule.(iii)The unit rate quoted by the contrcator also includes cost ofreplacement offoundation rubber bushes, nuts, and bolts , necessary electrical connection for making the appliances functional and cleaning of condenser etc.and nothing shall be paid extra on this account. |
| 88 | S&F in repair blower fan motor 1/10 or 1/35 HP suitable for water cooler of capacity 40/80 ltr, 60/120 ltr and 150/150 ltr, single phase 230 Volts including mounting ring/washer complete all asdirected. |
| 89 | S&F in repair Fan blade plastic suitable for fan motor 1/10 or 1/35 HP of water cooler of capacity 40/80 ltr, 60/120 ltr and 150/150 ltr, single phase 230 Volts including mounting ring/washer complete all asdirected. |
| 90 | S&F in repair stainless steel taps push button type, 15mm dia for water cooler of any capacity suitable for Usha/Blue Star water/voltas/sidhwal coolers complete all as directed. |
| 91 | S&F in repair Relay & overload set suitable for water cooler of capacity 40/80 ltr, 60/120 ltr and 150/150 ltr, single phase 230 Volts complete all as directed. |
| 92 | S&F in repair Starting/Running capacitor suitable for water cooler of capacity 40/80 ltr, 60/120 ltr and 150/150 ltr, single phase 230 Volts complete all as directed. |
| 93 | S&F in repair Thermostate valve uitable for water cooler of capacity 40/80 ltr, 60/120 ltr and 150/150 ltr, single phase 230 Volts complete all as directed |
| 94 | S&F in repair copper condesor for 40/80 and 60/120 ltr capacity water cooler complete all asdirected. |
| 95 | S&F in repair copper condesor for 150/150 ltr capacity water cooler complete all asdirected. |
| 96 | S&F in repair3 pin, 15 Amp top plug, 240 Volts, single phase complete all asdirected. |
| 97 | S&F in repair PVC float valves, high pressure, with polythene float and fly-nut (PTMT) complete,screwed for iron pipe of brass ferrule, suitable for water cooler of any capacity of size 15mm bore pipe complete all asdirected. |
| 98 | S&F in repair drain hose pipe not less than 1.5 metre length and 30mm diawith clamping arrangment complete all as directed. |
| 99 | S&F in repair drain hose pipe not less than 1.5 metre length and 40mm diawith clamping arrangment complete all as directed. |
| 100 | Supply and fixing in replacement Deep freezer Stainless Steel body of size not less than 3FeetX2FeetX2.5 Feet (lengthxbreadthxHeight) unit with Cooling Coil, and complete tank of GI sheetincluding heavy duty copper tubing and PUF insulation, condensor coil unit, condensor cooling fan motor with suitable size fan blade and elcetrical connection, capacitor,thermostate switch complete all as approved and as directed by Engineer-in-charge. Note :- (i)Compressor of Deep Freezershall be measured and paid separately under appropriate item of this BOQ as Supply and Fixing .(ii) The rate of Deep freezer Stainless steel body unit , New copper cooling coiland complete GI tankincluding heavy duty copper tubing, fan motor with blade,capacitor,condensor coil unit, nuts , bolts & washers and all connection and fixtures is included in this item and nothing shall be paid extra on this account. |
| 101 | S&F in replacement of refrigertordoor gasket and magnet for double door refrigerator ofanymake and capacitycomplete all as specified and directed. |
| 102 | S&F in replacement ofpigmy lamp (bulb) suitable for any make and capacity refrigerator complete all as specified and directed. |
| 103 | S&F in replacement ofdoor lock with two keys suitable for any capacity refrigerator complete all as specified and directed. |
| 104 | S&F in Replacement of receptacle tray as per existing suitable for water cooler of capacity 40/80 ltr, 60/120 ltr and 150/150 ltr, single phase 230 Volts complete all as directed |
| 105 | Cleaning of water coolers body internally and externally including scraping and removing all scales and dirt etc, repairing the body to check leakage and unserviceable screws, nut, bolt, washers etc complete all as specified and directed. |
| 106 | M&L for half/ yearly maintenance/ repair/ servicing of water purifier of any type and brand by taking down, dismantling, cleaning and replacing worn out/damaged parts such as carbon filter, UV lamp etc., including reassembling, refixing, connecting up and testing complete all as specified and directed.Note: (i) Cost of spare parts replaced during the process of repair/servicing shall be measured and paid separately as supply only under relevant item herein after.(ii) Labour charges for replacement of spares parts if any required during repair/ servicing deemed to be included in the quoted rate. |
| 107 | Supply only following spares required for replacement during the process of servicing/ repairing of water purifier herein before. RO Membrane |
| 108 | UF Membrane |
| 109 | Inline Carbon filter |
| 110 | Inline Sediment filter |
| 111 | Activated carbon filter |
| 112 | Post carbon filter |
| 113 | Solenoid Valve |
| 114 | Pre filter |
| 115 | UV lamp assembly |
| 116 | Pump Assembly |
| 117 | S&F in repair Fan blower suitable for Window Type/ SplitType Air Conditioner outdoor unit of capacity 1.5 Ton / 2.0 Ton complete all as directed. |
| 118 | S&F in drain pipe spring type 15 mm dia suitable forWindow Type/ SplitType Air Conditioner unit of capacity 1.5 Ton / 2.0 Ton complete all as directed. Note: Cost of necessary clamps and screws is included in this item and nothing will be paid extra on this account |