| 1 | M&L for 18/19mm thick prelaminated particle board, exterior grade, prelaminated both sides with decorative choice lamination, fixed with screws to timber frame work complete all as specified and directed. |
| 2 | S&F Continuous (piano) hinges, 30mm width of flaps (when open) mild steel, bright finish or electrogalvanised complete all as specified and directed. |
| 3 | S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and directed. |
| 4 | S&F brass locks, cupboard, grade I, size 50 mm, 2-levers complete all as specified and directed. |
| 5 | S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed. |
| 6 | S&F hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 7 | M&L for cutting holes in brick walls built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete of superfacial area exceeding 150sqcm but n exc 400 sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and directed. |
| 8 | M&L for 35 mm thick factory made Second class hardwood glazed and skeleton shuttersopen rebated and prepared to receive glass, gauze etc without sash bar any number fitted with cut and mitered beads for securing glass gauze etc , sizes of members of shutters as specified in SSR Part I section 8, Section 8.24(a) and fitted to chowkats complete all as specified and as directed. |
| 9 | S&F butt hinges medium weight cold rolled mild steel 100 mm long, complete all as specified and directed. |
| 10 | S & F 200 mm long aluminium anodized barrel tower bolts of extruded sections and fixed complete all as specified and as directed. |
| 11 | S & F 150 mm long Aluminum alloy handles, fabricated type, anodizedcomplete all as specified and directed. |
| 12 | S&F aluminium (extrude section body) door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and directed. |
| 13 | S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1mm fixed with tinned tacks or wire staples complete all as specified and as directed. |
| 14 | M&L for twocoats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or grith complete all as specified and directed. |
| 15 | M&L for twocoats of synthetic enamel paint over a coat of pink primer including preparation of new wood or wooden base surface over 10cm width or grith complete all as specified and directed. |
| 16 | Excavating over areas, n exc 1.5m deep and gettingout in hard/ dense soil complete all as specified and directed. |
| 17 | Removing excavated material exc 250m but n.exc 500 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 18 | M&L for PCC (1:4:8) Type D2 (40 mm graded aggre-gate) as in foundations, filling and mass-concretecomplete all as specified and directed. |
| 19 | M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. |
| 20 | M&L for 15mm thick rendering on fair faces of brick work or block masonary or concrete surface in cement plaster (1:4) finished the surface even and smooth without using extra cement complete all as specified and directed. |
| 21 | M&L for preparing newly plastered surfaces of wall and applying two coats ofcement base paint over a coat of cement primer complete all as specified and directed. |
| 22 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 23 | Dismantling of floor, hearth, or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store yard complete all as specified. |
| 24 | M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed. |
| 25 | M&L for PCC 1:2:4 type B-0, using 12.5mm graded stone aggregate as in window cill or similar work complete all as specified and directed. |
| 26 | M&L non skid ceramic digital tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over and including 15 mm thick screed bed in CM 1:6complete all as specified and directed.. |
| 27 | M&L Coloured Glazed digital ceramic tiles (350 x 250) x 7 mm/ (450 x 350) x 7mm thick or as required size as in vertical surface or dado/skirting, set andjointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 10 mm thick plaster in CM 1:4 complete all as specified and directed. |
| 28 | S&F mild steel , plain, black sheet, 1.6 mm thickin wall cladding, steel gates, and similar work cut to size, holes punched including round headed screws, clouts nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams including bending or turning up mitred angle etc as required complete all as specified and directed. |
| 29 | S&F mild steel , plain, black sheet, 1 mm thickin wall cladding, steel gates, and similar work cut to size, holes punched including round headed screws, clouts nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams including bending or turning up mitred angle etc as required complete all as specified and directed. |
| 30 | S & F mild steel rag or lewis bolt, 12 mm dia, screwed one end with hexagonal or squre nuts and washers the other end enlarged and jagged or lewised, n exc 15 cm long complete all as specified and directed. |
| 31 | M&L for writing letters or figures (block/roman/italic/indian, hindi or english) n exc 30cm hight with synthetic enamel paint complete all as specified and directed. |
| 32 | Excavating in post holes in hard/dense soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed. |
| 33 | M&L for PCC 1:3:6 type C-2, using 40 mm graded stone aggregate as in pillars, boundary pillars and fencing post or similar work complete all as specified and directed. |
| 34 | S&F for rolled section as main and cross beam, hip and jak rafters, purlins where connected to common rafters and running, rails, vertical members and guides for sliding doors, fixed with angle creats or other connecting plates etc confirming Fe-290, Gde E-165 complete all as specified and directed. |
| 35 | S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self tapping screws complete all as specified and directed. |
| 36 | S&F 16mm dia of neck mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed. |
| 37 | S&F rolled mild steel in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe 410-W(GdeE- 250) quality A complete all as specified and directed. |
| 38 | S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self tapping screws complete all as specified and directed. |
| 39 | Material and labour for point wiring for One 3 pin 5 amps socket outlet on independent board with using 1.5 Sqmm (nominal area) multistranded copper conductor, FR single core, PVC insulated & unsheathed cable, 1100 volts grade in non metallic rigid PVC oval conduit/PVC casing caping (Medium grade) of suitable size not less then 20 mm dia including necessary accessories like bends, tees, elbow etc fixed on wall/ceiling all as directed with using 2nd class hard woodedn board/new sunken type pressed MS box/terminal boxes of suitable size with plastic laminated white coloured sheet top cover 3mm thick for mounting fittings wiring accessories with and including all accessories andusing 1.5 Sqmm (nominal area) stranded copper conductor FR single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. |
| 40 | S&F Exhaust Fan, Steel body AC single Phase 230 V of size 300 mm sweep with blades, frame and louvers complete all as directed and specified. |
| 41 | Supply and fixing ceiling fans of 1200mm sweep, complete with blades, down rods, electronic regulator and accessories, 230 V, Minimum air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as directed. |
| 42 | Supply, installation, testing and commissioning of UL listed Addressable Fire Alarm/control Panel with single Loop (expandable up to four loops) and maximum 254 devices of any combination in a loop (maximum 1016 Devices of any combination per panel), microprocessor based panel suitable for wall/floor mounting fabricated from 18 SWG CRCA sheet, Touch Keypad for user friendly operation, 40 X 4 Characters LCD display, Day / Night Mode facility, front panel programmable with Loop redundancy, operating voltage of 24V DC, power supply, batterty, charger including interconnections of all zones complete all as per specifications and directed. NOTE:- System should comply with Indian Manufacturer – International standard. Auxiliary relay 1 set of changeover contacts operate in event of fire condition. |
| 43 | Supply, installation & testing of UL Listed sounder cum storb havingaudibility level of 85dB, 4 Candela setting 15/30/75/110cd flashing capacity at 1HZ for Visual indications, integrated with Control Modules with necessary auxiliary voltages, working on 24VDC auxiliary power supplies, two audible tone settingsand comply withinternational standards such as NFPA72 (2016 edition) complete all as specified and directed. The sounder shall be addressable electronic type and shall give discontinuous/ intermittent audible alarm whenever any detector or call box operates. |
| 44 | Supply, installation & commissioning of Manual Call point made of CRCA sheet (corrosion resistant) comes with a factory fitted back box for Surface or Semiflush mounting on the wall, metal hammer attached by chaina for glass break, Red dual LED indication at fire /Alarm condition, Input Supply :24VDC, Standby Current :150mA, Alarm current :60mAcomplete all as specified and directed. |
| 45 | S&FMulticriteria smoke detector sensors with operatingvoltage range of 24V DC +/- 2Volts, protectiongrade IP-32 operating teperature 0 to 60 degree C, humidity range <95% RH, made of whitePolycarbonate/ABS FR material, Dual LED design provides 360° viewing angle for indications complete with base of detector etc complete all as specified and directed. |
| 46 | S&F response indicators with operating voltage 24 V DC +/- 2V, Alarm current :100mA, Operating current :6-10mA, 2 nos. RED color LED, made out of white color powder coated18 SWG MS CRCA sheet complete all as specified and directed. |
| 47 | Supply, laying and testing of 2C x 1.5 sq.mm, Multi Stranded copper conductor twisted pair, shielded, FRLS armored fire alarm cable with RED insulation, type A ST1, 650 V as per IS 1554, with GI saddle spacers every 0.3 meter with single compression cable glands, ABS Junction Boxes (wherever required), terminals, Ferruling complete for centralizes monitoring panel complete all as specified and directed. |