| 1 | Excavation in post holes (or similar holes) each n exe 0.5 Cum getting out, returning, filling in and ramming earth or broken rubble mixes with earth around, in layers not exceeding 25 cm in soft/loose soil. |
| 2 | Supply and fix Hand rail, half round or other steel section or core for wooden hand-rail straight portion, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc., flat iron fillets (for securing wire mesh etc., ) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290, Gde E-165, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc., wind ties for roof including securing bolts. |
| 3 | S&F polycarbonate roofing sheet 6 mm thick white/coloured sheet as in roof covering/cladding to wall, fixed with self-tapping screws all as specified and directed by Engineer-in-Charge. |
| 4 | S&F steel work in tubular trusses including special shaped washer etc., complete using ERW or including butt welded tubes conforming to IS 1161-1979 grade St-240 |
| 5 | M&L Plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete all as specified. |
| 6 | M&L for preparation of new steel surface of any description, over 10 cm in width or girth when unconnected with two coat synthetic enamel paint over a coat of red oxide complete. |
| 7 | Point wiring with 1.5 Sqmm multistrand, FRLS copper conductor cable, PVC insulated and unsheathed, drawing in and including PVCconduit 20 mm dia medium grade ISI marked with all accessories such as bends, elbows reducers, pressed steel/ MS terminal boxes factory made 1.6 mm thick dully painted in rectangular shape appropriate size (having wall thickness of conduit not less than 2.00 mm) for one light/ fan point controlled by one 5 Amps switch one way, covered with 3 mm thick plastic laminated sheet top cover for mounting switches, sockets requlators etc and continous PVC insulated and unsheathed 1.5 Sqmm copper conductor cable multistrand as earth wire, complete all as specified. |
| 8 | S&F switch piano 6 amps flush type single pole one way |
| 9 | Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 core |
| 10 | Supply and fixing single pole neutral Sheet metal enclosure for 02 way DBs when SPN to be used single phase 240 volts, single door complete all as specified and as directed. |
| 11 | S&F MCBs of\"C\" series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of SPN 32 amp. |
| 12 | Supply and fixing LED lights fitting 1x 20W, 220V,AC aluminium body decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.make-philips,havells ,crompton |
| 13 | Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connecting with galvanizing iron & steel GI earth wire 4 mm dia by means of bolt nut check nuts and washers of galvanised iron, 15 mm dia GI Pipe for protection to earth lead including PCC with 1:2:4 type B1 using 20mm graded stone aggregate CI frame and cover of angle iron 25 X 25 X 3 mm with 6 mm dia MS bar made to shape GI medium 20 mm bore pipe for watering in any type of soil returning filling in and removal of surplus soil to a distance n.exc 5.0 mm all as per electric plate no.3OF SSR 2009 Part I connected to earth test point all as specified and indicated including testing on completion. |
| 14 | M&L point wiring for modular switches with4 Sqmm, PVC insulated, unsheathed, multistranded,copper conductor Cable, FRLS, 1100 Volt grade, drawn throughand including concealed, rigid non-metallic PVC Conduit of minimum 25mm dia orasper site requirement with all fittings, including cadmium plated screws as per IS, including 2.5 Sqmm size, PVC insulated, unsheathed, copper earth continuity conductor, connected to earth dolly, suitable for one Geyser point controlled by sigle ple MCB completeall as specified and as directed. |
| 15 | S&F sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one MCB of capacity 20 Amps , 240 Volts complete all as specified and directed. |
| 16 | Supply and Fixingof five star rated Geysers white blue in colour capacity 25 Ltr, Electric Driven, Single phase, 240 V, Storage vertical type and heating element 2 KW, inner shell made up of copper, automatic cutoff,manual tempreture setting , maintaining 8 bar pressue including electrical and water connection with hot and cold water connection pipe (PVC type) and fixed on the wall with mild steel fastner 150 mm long and 10 mm dia with pin and bolts complete all as specified and directed. |
| 17 | S&F MCB SP, 240 Volts, 25 Amps complete all as specified and directed. |