| 1 | Demolition of Stone slabs and tiles laid in any mortar of any description or thickness in floors, aprons etc |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level)all as specified and directed. |
| 3 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out as soft soil all as specified and directed. |
| 4 | Removing excavated material exc. 250m but n exc 1.5 KM and depositing where directed complete all as specified. |
| 5 | M & L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. |
| 6 | M&L Cement concrete type D2 1:4:8 (40 mm graded aggregate) in foundations, filling and mass-concrete complete all as specified and directed. |
| 7 | Formwork to flat Rough finished surfaces of concrete sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to better complete all as specified and directed. |
| 8 | Formwork square, rectangular or polygonal to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed |
| 9 | Formwork to flat Rough finished surfaces of concrete sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed |
| 10 | Formwork to flat Rough finished surfaces of concrete soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping)complete all as specified and directed |
| 11 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide |
| 12 | S&F for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns,Beams,footing, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 13 | S&F for TMT steel bars5mm dia and over upto and including 10mm dia in stirrups, spacers and binder, cut to length, bent shape required, including cranking , bending, hooking etc and binding with MS wire 0.9mm dia(annealed as directed by Engineer-in-Charge. |
| 14 | M & L for Design Mix RCC M-25using 20mm graded crushed stone aggregate asin foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete. |
| 15 | M & L for Design Mix RCC M-25 using20mm graded crushed stone aggregate asin columns,pillars etc complete. |
| 16 | M & L for Design Mix RCC M-25using 20mm graded crushed stone aggregate asinroof slabs, etc complete. |
| 17 | M & L for Design Mix RCC M-25 using 20mm graded crushed stone aggregate asinlintels beams and roof beams etc complete. |
| 18 | M&L for 10 mm thick rendering in CM 1:3 over concrete surfaces (Roof) mixed with water proofing compound @ 3% by weight of cement complete all as specified.NOTE :Water proofing compound shall be measured and paid for separately as “Supply only” |
| 19 | M&L for preparation of new plastered surfaces and applying two coats of Polyurethene(PU) acrylic based water proofing liquid compound over one coat of diluted self priming with reinforcing fabric sheet as per manufacturer instruction to stop leakage/seepage from roof/wall complete all as specified and directed for work in building/structure of any height. |
| 20 | Supply only integral water proofing compound |
| 21 | Earth filling under floor spreading and leveling in layers n.exc 25cm thick including welll ramming including watering as required all as specified and as directed. |
| 22 | M&L for 150 mm thick Hard core of gauge n.exc 63mm of branch stone, and leveled in llayers n. exc 15 cm thick watered and rammed to true surface all as specified as directed. |
| 23 | M & L for 100 mm thick PCC 1:4:8 type C2 ( Using 40 mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 24 | M&L machine cut Kota stone slab flooring 20-25mm thickas in floor, laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab incl. Rubbing and polishing with mirror polish including15 mm thick screed bed or bedding layer in CM 1:6 completeall as specified and complete. |
| 25 | Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed withgrey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 10 mm thick as baching coat in CM 1:4 , complete all as specified and directed |
| 26 | M & LforPre-cast cementconcrete blockmasonry, 1:3:6 Type C1 (20 mm graded ) withsolid blocks, exc. 10cm in width andsettingbuilt in CM 1:6complete all as specified and directed |
| 27 | M&L for cement plaster 1:6 Rendering 10 mm thick on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed |
| 28 | M&L for cement plaster 1:3 Rendering 5mm thick on ceiling complete all as specified and directed |
| 29 | M&L for cement plaster 1:4 rendering 15 mm thick on external surfacefinished even and smooth (without using extra cement) complete all as specified and directed |
| 30 | M & L for preparing of new surfaces, plastered or unplastered and applying three coat of white wash on ceiling complete all as specified and directed. |
| 31 | M & L for preparing of new surfaces, plastered or unplastered and applying two coat of oil emulsion distemper on walls over one coat of1 mm thick putty complete all as specified and directed |
| 32 | M & L for preparing of new surfaces, plastered or unplastered two coat of cement base paint over one coat of primer on external walls complete all as specified and directed |
| 33 | S&F Aluminium window and ventilator powder coating shutters of any colour ( thickness of powder coating not less than 50 micron), side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) completeallasspecified and directed by Engineer-in-Charge |
| 34 | S&F Powder coated aluminium (minimum thickness of powder coating 50micron) work for doors, windows, louver type ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge complete all as specified and as directed Note :- S& F of 4mm thick glass & SS wire meshpayment will be made seprately) |
| 35 | M&L 4 mm thick sheet glass, ordinary quality n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 36 | S&FAluminium anodised powder coatinggrill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin- charge. |
| 37 | S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore plastic ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic plastic ball screwed for iron pipe and fixed. (Minimum weight of ball valve - 210 gms)as directed by Engineer-in-Charge |
| 38 | S& F 20 mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed. |
| 39 | S & F 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed as directed by Engineer-in-Charge. |
| 40 | S&Fvitreous china wash basin, white, flat back/Angle Back , size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/ fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32mm bore and of suitable length,15mm borepillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipePVC connection 15 mm size withnuts of length 450 mm.complete all as specified and as directed by Engineer-in-Charge |
| 41 | S & F for Steel rolling shutters 1.25 mm thick sheet, with out ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indi cated, complete: push pull or manual type all as specified and directed by Engr-in-Charge |
| 42 | S & F for safety lever locks mild steelwith 4 levers forrollingshutters all as specified and directed by Engr-in-Charge |
| 43 | M & L for preperation of new steel surfaces of any description, over 10cm in width or girthwithtwo coat synthetic enamel paint over a coat of red oxide complete. |
| 44 | M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 45 | M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of60 mm thickness, M-35Grade with grey cement and pigment complete all as specified and directed |
| 46 | M & L for at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete |
| 47 | M&L for preparation of new concrete surfaces as in road side kerbs and applying two coats of synthethic enamel paint of approved different tints and pattern over a coat of primer etc complete all as specified and directed. |
| 48 | M&L for glazed ceramic tiles, coloured, 450x350x7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointedin neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:6 on fair faces of concrete or brick surfaces as directed by Engineer-in-Charge. |
| 49 | Dismantting of AC/CGI/Fibre glasssheet corrugated/ semi corrugated sheet & ridge in roof covering Complete all as specified. |
| 50 | Dismantling wrought iron or mild steel work of any description not otherwise provided for and removing from site all as specified and directed. |
| 51 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft /loose soil |
| 52 | Supply and fixmm dia Hand rails, half round or othersteel section or core for woodenhand-rail straight portion, posts and struts in fencingincluding cutting tops to shapeas directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire meshetc.) including all necessarydrilling,boltingor riveting, etc.,and similar work conforming toFe-290 Gde E-165 → drilled and countersunk forbalusters running bars, fordoors, balusters,nosingtostepsincludingembedinginconcreteand screwing etc. wind ties forroofincluding securing bolts |
| 53 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour havingtensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with selftapping screws as specified |
| 54 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confrming to IS 1161-1979 grade St-240 |
| 55 | Demolition of Brickwork of stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles |
| 56 | Cleaning of lined/pucca drain of any description or any shape etc exceeding 0.50 sqm in cross section area by excavating mud in any situation including cutting and cleanign all shurbs , grass vegetation, plants etc from in side portion fo drain as well as on both side of drain (at ground level) to a distance of 1.5m on both side and removing the same to a distance upto 500m and disposting where directed at a level n exc. 1.5m above the starting point complete all as specified. |
| 57 | Taking down mud plaster on brick or stone wall etc including raking out joints wall etc including raking out joints , hacking for key , scrubbing down with water etc |
| 58 | 100 m thick PCC 1:2:4 type B-2 (using 40MM graded aggregate) as in surfacechannel and drains all as specified |
| 59 | Material & labour for precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cover slab for manhole etc with plane faces complete all as specified and directed by Engineer-in-Charge. |
| 60 | Supply & fixing Reinforced Cement Concrete pipes 150mm dia, class NP2, laid & jointed complete with collars complete all as specified and directed by the Engineer-in-Charge. |
| 61 | Material & labour for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in bed to drain pipes of size 150 mm bore, including packing under & haunching against the sides of pipes after they are laid and tested complete all as specified and directed by the Engineer-in-Charge. |
| 62 | M & L for Granite (of any type) tiles 18mm to 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment tomatch the shade of granite stone including grinding and polishing over 15 mm thick Screed bed or bedding layer for laying floor finishes in CM 1:6 completed all as directed by Engineer-in-Charge |
| 63 | M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as specified and directed |
| 64 | M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core,FRLSH, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in concealed conduit heavy duty (HMS Grade), GI terminal boxes not less than 1.0mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover or including modular plates of required size for mounting switch and sockets etc. complete all as specified and directed for following : -Note : Quoted rates deems to be included cost of modular plate for mounting switches, sockets & regulators as required at site. |
| 65 | One light / fan point controlled by one switch one way. |
| 66 | One 3 pin 5 Amp switch & socket outlet on Independant board. |
| 67 | All same as per item ser No 64.00 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, FRLSH, single core, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independant board. |
| 68 | M&L for celing rose single phase /pvc/polycorbonate ,isolated bodycomplete all as specified and as directed. |
| 69 | S&F modular switches 6 amps single pole one way |
| 70 | S&F modular switches 16 Asingle pole one way |
| 71 | S&F modularsocketes outlet6 amps 5 pin |
| 72 | S&F modularsocket 16 A 5 pin combined |
| 73 | S&F modular Step fan Speed regulator 5 steps |
| 74 | S&F in single pole and neutral enclosure with a two pin and earth plug and socket complete one single pole MCB 20 Amp complete all as specified and directed. |
| 75 | Supply and draw in submain wiring with two single core 6 sqmm FRLS PVC insulated copper cable 1100 volts grade multistrand, unseathed conductor drawn into PVC conduit and all necessary fittings including 6 sqmm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dully complete all as specified and directed. |
| 76 | Supply and fixing in High garde aluminium housing for better light and heat dissipation,6500K cool white LED 4 feet tube light fitting 1x 20W lumen up to 4000, 220V,AC batten type connecting up withflexible copper conductor cable of suitable size from ceiling rose complete Make:- Orientor equivalent approved in Philips/ Havells/ Wipro |
| 77 | Supply and fixing LED flood light 50 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection,complete with driver and lamp complete all as specifiedby Engr-in-Charge. |
| 78 | Supply and fixing Elegant white colour base model ceiling fan of size 1200 mm sweep, 3 blades, five speed, noise level up to 65 dB,single phase 230 Volts, 50 HZ complete all as specified and directed. Make:- Havells Model no. FHCHM5SWHT48or equivalent approved in Philips/ Bajaj/ Usha |
| 79 | M&L for fixing Anti suicide fan down rod 10 inch (off white color), hanging fan and making necessary electrical connectinons, testing fan for its smooth functioning. Antisucide Fan rod shallmanufactured with inbuilt spring so as to brake and hang on spring when load on fan exceeds 20 kg. Fan rods shall be tested and approved by Govt of India MSME Labotary all as specified and directed. Make- GOLD LIFE manufactured by Safe soluction, Mumbai or equivalen in similar specification in approved makes |
| 80 | Supply, installations, testing and commissioning factory made indoor cubical wall mounted type panel box for fixing energy meter, 4 each separate compartment for each energy meter, frabricated using 2.0mm thick MS sheet, duly provided with 8 mm thick flame proof backelite/hylem sheet for mounting Enegry meters in each compartment, and provision pre-wiring and fixing of incomming and outgoing control MCCB/MCBs, each meter comapartent shall provided with front opening hinged door with internal or external locking arrangment. MS box duly paintedwith two coats of powder coated Semense gray paint over a coat of red oxide primer. The meter box shall designed and fabricated for fixing 01 x MCCB 100 Amps 4 pole as incommer and vertical or horizontal copper busbar chamber for taking connection to incommer MCB of each meter by using 10 Sqmm, PVC insulated multistranded copper conduction wire single core in proper color codes all as specified to accomodated as under :-(a) MCCB 100 Ams, 4 pole, 16 kA,(Ics=100 % of Icu) -as incommer(b) Copper Busbar 200 Amps duly sleev insulated for set of 3 phase, 4 wire system - 01 Set(c) 2 runs of PVC insulated single core multistraded FRLS grade copper wire for conncetion from busbar to input supply of Each energy meter by using necessary copper alloy lugs/thimbles.(d) MCB SPN 63 Amps on each meter incomming pre-wired-4 Nos (One each meter)(e) MCB SPN 40 Amps on each meter outgoing pre-wired-1Nos (one outgoing for security light/staircase light)(f)LED Indicator lamp (R,Y,B)- Set of Three.Note : Quoted rate includes the cost of all necessary clamp, wall fasters for fixing meter box on wall surface and re-fixing energy meters & making all incomming and outgoing electrical connections with existing input cable and outgoing wires. |
| 81 | Supply and fix sheet metal enclosure distribution board for 240 volts, 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completioncompleteall as directed. |
| 82 | M&L for MCB SPN 40Amps To 63 amps 240 volts, 10 kA,C curve rupturing capacity providing in DB completeconnection & testing all as specified. |
| 83 | Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA C curverupturing capacity providing in DB complete connection & testing all as specified. |
| 84 | S&F of XLPE insulated ,armoured heavy duty electric cable with aluminium conductor ,1100 volts grade cross sectional area 25 Sqmm4 core complete all as specified and as directed. |
| 85 | S&F of single Phase digital Electric Meter |
| 86 | Material and labuor for earthing complete with Galvanized Steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level and filled with 15cm thick alternate layers of charcoal and salt, connected & including GI wire earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron protected by 15mm dia GI Pipe (light grade). Earth plate shall be surrounded by alternate layers of charcoal or coke and common salt in 15cm thick in layers & 15cm of widht all aurround of earth plate including 20mm dia GI light grade pipe for watering and including funnel, wire mesh, necessary earth work in any type of soil, Pre-cast RCC cover duly re inforced with 8mm dia TMT Bar @150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar embedded in cover slab, Earth Pit of PCC (1:3:6) type C2 (using 20mm graded crushed store aggrgate)complete all as specified and as shown in electrical plate No-3 of SSR Part-I including testing on completion.Note:- (i)PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate. |
| 87 | Supply and fix air cooled split unit air conditioner electric driven single phase of capacity of 1.5 TR, BEE 5 star rated complete all as specified and as directed |
| 88 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and as directed. |
| 89 | Supply and Fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one doublepole MCB 20 Amp, 240 V complete all as specified and as directed. |