| 1 | Material and labour Inspection, Servicing and Maintenance of 380/ 400 KVA DG Set, of any make /model of Kirloskar /Greaves/Cummins byInspection and Schedule\"B\" checkas per OEM/ manufacturerf\"s mannual and testing of DG Set all as directed by Engineer-in-Charge. Note :- Spare parts shall be measured and paidseparately under respective item of this sch . |
| 2 | S&F following spares parts for DG set of capacity 380/400 KVA :- |
| 3 | (a) S&F Lubricating oil filter (Primary & Secondary) for 380/400 KVA DG Sets |
| 4 | (b) S&F Fuel filter elementmicro assy for 380/400 KVA DG Sets |
| 5 | (c) S&F Fuel filter element pre for 380/400 KVA DG Sets |
| 6 | (d)S&F Primary air cleaner element complete for 380/400 KVA |
| 7 | (e)S&F safety air cleaner element complete for 380/400 KVA |
| 8 | All as per Serial Item No. 01 here in before butof320 KVADG Sets of existing Cummins/Greaves/Kirloskar make. |
| 9 | S&F following spares parts for DG set of capacity320 KVA :- |
| 10 | (a) S&F Lubricating oil filterfor 320 KVA DG Sets |
| 11 | (b) S&F Fuel filter element micro 320 KVA DG Sets |
| 12 | (c) S&F Fuel filter elementpre for320 KVA DG Sets |
| 13 | (d)S&F Primary air cleaner element complete for320 KVA DG Sets |
| 14 | (e) S&F safety air cleaner element complete for 320 KVA DG Sets |
| 15 | All as per Serial Item No. 01 here in before butof250 KVADG Sets of existing Cummins/Greaves/Kirloskar make. |
| 16 | S&F following spares parts for DG set of capacity250 KVA :- |
| 17 | (a) S&F Lubricating oil filter (Primary & Secondary) for 250 KVA DG Sets |
| 18 | (b) S&F Fuel filter element micro 250 KVA DG Sets |
| 19 | (c) S&F Fuel filter elementpre for250 KVA DG Sets |
| 20 | (d)S&F Primary air cleaner element complete for250 KVA DG Sets |
| 21 | (e) S&F safety air cleaner element complete for 250 KVA DG Sets |
| 22 | All as per Serial Item No. 01 here in before butof 200 KVADG Sets of existing Cummins/Greaves/Kirloskar make. |
| 23 | S&F following spares parts for DG set of capacity 200 KVA:- |
| 24 | (a) S&F Lubricating oil filter (Primary & Secondary)for 200 KVADG Sets |
| 25 | (b) S&F Fuel filter element micro for 200 KVADG Sets |
| 26 | (c) S&F Fuel filter elementpre for 200 KVADG Sets |
| 27 | (d)S&F Primary air cleaner element complete for 200 KVADG Sets |
| 28 | (e) S&F safety air cleaner element complete for 200 KVADG Sets |
| 29 | All as per Serial Item No. 01here in before butof 125 KVADG Sets of existing Cummins/Greaves/Kirloskar make. |
| 30 | S&F following spares parts for DG set of capacity 125 KVA :- |
| 31 | (a) S&F Lubricating oil filter (Primary & Secondary) for 125 KVA |
| 32 | (b) S&F Fuel filter element micro for 125 KVA |
| 33 | (c) S&F Fuel filter element pre for 125 KVA |
| 34 | (d)S&F Primary air cleaner element complete for 125 KVA |
| 35 | (e) S&F safety air cleaner element complete for 125 KVA |
| 36 | All as per Serial Item No. 01here in before butof100 KVADG Sets of existing Cummins/Greaves/Kirloskar make. |
| 37 | S&F following spares parts for DG set of capacity100 KVA :- |
| 38 | (a) S&F Lubricating oil filter (Primary & Secondary)for 100 KVA |
| 39 | (b) S&F Fuel filter element micro for 100 KVA |
| 40 | (c) S&F Fuel filter element pre for 100 KVA |
| 41 | (d)S&F Primary air cleaner element complete for 100 KVA |
| 42 | (e) S&F safety air cleaner element complete for 100 KVA |
| 43 | All as per Serial Item No. 01here in before butof 82.5 KVADG Sets of existing Cummins/Greaves/Kirloskar make. |
| 44 | S&F following spares parts for DG set of capacity 82.5 KVA :- |
| 45 | (a) S&F Lubricating oil filter(Primary & Secondary) for 82.5 KVA |
| 46 | (b) S&F Fuel filter element micro for 82.5 KVA |
| 47 | (c) S&F Fuel filter element pre for 82.5 KVA |
| 48 | (d)S&F Primary air cleaner element complete for 82.5 KVA |
| 49 | (e) S&F safety air cleaner element complete forr 82.5 KVA |
| 50 | All as per Serial Item No. 01here in before butof 62.5 KVADG Sets of existing Cummins/Greaves/Kirloskar make. |
| 51 | S&F following spares parts for DG set of capacity 62.5 KVA :- |
| 52 | (a) S&F Lubricating oil filter (Primary & Secondary) for 62.5 KVA |
| 53 | (b) S&F Fuel filter element micro for 62.5 KVA |
| 54 | (c) S&F Fuel filter element pre for 62.5 KVA |
| 55 | (d)S&F Primary air cleaner element complete for 62.5 KVA |
| 56 | (e) S&F safety air cleaner element complete for 62.5 KVA |
| 57 | All as per Serial Item No. 01 here in before butof 50 KVA to 55 KVADG Sets of existing Cummins/Greaves/Kirloskar make. |
| 58 | S&F following spares parts for DG set of capacity 50 KVA to 55 KVA:- |
| 59 | (a) S&F Lubricating oil filter (Primary & Secondary) for 50 KVA to 55 KVA |
| 60 | (b) S&F Fuel filter element micro for 50 KVA to 55 KVA |
| 61 | (c) S&F Fuel filter element pre for 50 KVA to 55 KVA |
| 62 | (d) S&F Primary air cleaner element complete for 50 KVA to 55 KVA |
| 63 | (e) S&F safety air cleaner element complete for 50 KVA to 55 KVA |
| 64 | All as per Serial Item No. 01 here in before butof for 35/40 KVADG Sets of existing Cummins/Greaves/Kirloskar make. |
| 65 | S&F following spares parts for DG set of capacity35/ 40 KVA :- |
| 66 | (a) S&F Lubricating oil filter(Primary & Secondary) for 35/40 KVA |
| 67 | (b) S&F Fuel filter primary & secondary complete for 35/40 KVA |
| 68 | (d) S&F main air cleaner element complete for 35/40 KVA |
| 69 | All as per Serial Item No. 01 here in before butof for upto 20 KVADG Sets of existing Cummins/Greaves/Kirloskar make. |
| 70 | S&F following spares for DG set of capacity upto 20 KVA :- |
| 71 | (a)S&F Lub Oil Filter |
| 72 | (b) S&F Fuel filter element |
| 73 | (c)S&F Air cleaner element |
| 74 | Note for item No. 1,3,5,7,9,11,13,15,17,19,21:1.Spare parts shall be measured and paid separately under respective items 2. Minor spare parts, which are essential for carrying out servicing but specifically not included in the description of item with a comutative cost up toRs. 500/- shall also deemed to be included in the unit rate.3.The spare parts shall be of reputed brand / make and shall be of same type, design, specifications etc to match with the existing and as per the recommendation of OEM. |
| 75 | M&L for repair and servicing the radiator for DG set of capacity 250 KVAfor repairing and descaling with suitable chemical as per OEM recomendation,toremove radiator internally deposit scale from ,tube and soldering the copper/Al/steel tubes and tank etc for arresting leakage and re-fixing after leak test through authorised Original equipment manufacturer\"s service centre engineers or throuigh OEM certified agencies as approved by GE complete all as specified and directed. |
| 76 | All as per Serial Item No 23 here-in-before but for DG Capacity 72/82.5/100 KVA. |
| 77 | All as per Serial Item No 23 here-in-before but for DG Capacity 50 to 62.5KVA. |
| 78 | All as per Serial Item No 23 here-in-before but for DG Capacity20/30 KVA |
| 79 | All as per Serial Item No 23 here-in-before but for DG Capacity320 to 400 KVA |
| 80 | S &F in repair electronic Govrerner -24DC suitable for 250 KVA DG set including repalcement of electronic governer acutator-24VDC and relay card and necessary items to make the governor functional complete all as specified and as directed. |
| 81 | M&L for repairing of fuel shut off valve 12/24 V assy for DG set including testing after repair for smooth operation complete all as directed. |
| 82 | M & L for repair ofSelf starter of 24 Volts capacity for DG Setby replacing unserviceable carbon brushes, brush holder,bearings, solenoid coil , replacement of pinion gears, replacement of burnt armature etc including refixing , testing and commissioning complete all as specified and directed |
| 83 | M & L for repair ofSelf starter of 12 Volts capacity for DG Setby replacing unserviceable carbon brushes, brush holder,bearings, solenoid coil , replacement of pinion gears, replacement of burnt armature etc including refixing , testing and commissioning complete all as specified and directed |
| 84 | Supply and fix in repair Benjo bolts . |
| 85 | Supply and fix in repair fuel pipe, filter to FIPwire braided complete all as specified and directed |
| 86 | Supply and fix in repair Water outlet and inlet hose pipe from radiator to Engine and backfrom Engine to radiator for any make/model DG set |
| 87 | Supply and fix in repair Lub oil pipe suitable for DG set of any make/Model complete all as specified and directed |
| 88 | Supply and fix in repair Anti vibration rubber pad forradiator. |
| 89 | Supply and fix in repair Lub oil pressure gauge0 to 10 kg / sq cm. |
| 90 | Note for item Sl No. 35 to37:The spare parts shall be of reputed brand / make and shall be of same type, design, specifications etc to match with the existing and as per the recommendation of OEM. |
| 91 | M&L for repairing/servicing of alternator ofGen set of capacity 320/380/400 KVA and heat varnishing including replacement ofball bearing/bushes and other electronic parts and coupling and refixing after repair including testing complete all as specified and directed by Engr-in-charge Note :- For item Ser No 39,40,41,42 u/s parts replaced willbe measured under respective item seperately. |
| 92 | All as per Serial Item No 38 here in before butfor of size 200/250 KVA |
| 93 | All as per Serial Item No 38 here in before butfor of size 82.5/100/125 KVA |
| 94 | All as per Serial Item No 38 here in before butfor of size 40/50/62.5 KVA |
| 95 | All as per Serial Item No 38 here in before butfor of size upto 20 KVA |
| 96 | Supply only following spares parts :- |
| 97 | Supply Only Bearings / bushes for DG set capacity 320/380/400 KVAMake : Tata/SKF/NBC |
| 98 | Supply Only Bearings / bushes for DG set capacity 200/250 KVA |
| 99 | Supply Only Bearings / bushes for DG set capacity 82.5/100/125 KVA |
| 100 | Supply Only Bearings / bushes for DG set capacity 20/40/50/62.5 KVA |
| 101 | Supply Only Bearings / bushes for DG set capacity 7.5 to 20 KVA |
| 102 | Supply Only Rectifier,diode plate etc suitable for DG set of capacity 320/380/400 KVAMake : kirloskar or equivalent |
| 103 | Supply Only Rectifier,diode plate etc suitable for DG set of capacity 200/250 KVAMake : kirloskar or equivalent |
| 104 | Supply OnlyRectifier,diode plate etc of suitable for DG set of capacity 82.5/100/125 KVAMake : kirloskar or equivalent |
| 105 | Supply Only Rectifier,diode plate etc of suitable for DG set of capacity 20/40/50/62.5 KVAMake : kirloskar or equivalent |
| 106 | Supply Only Rectifier,diode plate etc of suitable for DG set of capacity 7.5 to 20 KVAMake : kirloskar or equivalent |
| 107 | M & L for Dismantling and taking out fuel injection pump and injector assy set from DG set of any type/make and capacity upto 63 KVAfor carrying repairing, servicing/overhauling and caliberation of fuel pump and replacement of DV value, plunger as per manufaturer instruction , assembling the same with DG set properly in original position, checking the alignment, making proper fuel connectionfrom authorised dealers workshop including refixing and testingand testingof DG Set for smooth operation complete all as directed by Engineer-in-Charge. |
| 108 | All as per serial item no. 44 here in before but of size 100/125 KVA |
| 109 | All as per serial item no. 44 here in before but of size 200/250 KVA |
| 110 | All as per serial item no. 44 here in before but of size 320/380/400 KVA |
| 111 | M & L fordismantling of water pumpfor repairingof DG of capacity upto 62.5 KVA by necessary descalling including repairing/replacingof suction and discharge pipe bynecessary welding and lath work,replacement of water pump kit including refixing and testing complete all as directed by Engineer-in-Charge. |
| 112 | All as per item Sl No. 48 above but DG set of capacity 82.5 to 125 KVA |
| 113 | All as per item Sl No. 48 above but DG set of capacity 200 to 250 KVA |
| 114 | All as per item Sl No. 48 above but DG set of capacity 320 to 400 KVA |
| 115 | Supply and filling Engine oil of 15W40 grade of DG Set of capacity 15 KVA to 380 KVA DG Set , Make : GREAVES MAXTHERM SAE or equivalent Make from IOC/HPL/kirloskar |
| 116 | Supply and fix in repair premixcoolent suitable for DG set radiator in plastic container all as specified and as directed. Make : K Cool Super/Greaves/Waxpool |
| 117 | Repairs/Adjusting to automatic voltage regulator (AVR) of DG set of any capacity complete all as specified and directed. |
| 118 | M&L for replacement of faulty automatic voltage regulator (AVR) including electronic printed circuit board (PCB)for upto 100 KVA DG capacity of existing make/model and as approved by Engr-in-charge complete all as specified and directed. |
| 119 | same as above item no 55 but for DG Set of 200/ 250 KVA capacity complete all as specified and directed. |
| 120 | same as above item no 55 but for DG Set of 400 KVA capacity complete all as specified and directed. |
| 121 | M & L for Removal of old painted surface of DG Set of any size/capacity complete by scraping with emry paper and cleaning by thinner and finishing the surface smooth for new paiting of two coat of spray painting with synethetic enamel paint complete including writing of SM/MES No and colour code for DG set upto 62.5 KVA all as directed by Engineer-in-Charge. |
| 122 | same as above item no 58 but for DG Set of 82.5 to 125 KVA capacity complete all as specified and directed. |
| 123 | same as above item no 58but for DG Set of 200 to 400 KVA capacity complete all as specified and directed. |
| 124 | Supply and fix in repairbattery lead in red and black colour for 180 AH, 12V battery copper conductor PVC insulated multi stranded single core 1.50 Mtr long (two Nos) duly fixed with terminals and lugs complete all as directed. |
| 125 | Supply and fixBrass connector for battery terminal positive and negative. |
| 126 | Supply and fix in repair ignition switch with key. Make : kirloskar or equivalent |
| 127 | Supply and fix in repair off load change over switch415 volt 50 Hz confirm to IS-13947-3 with enclosure and side handle of cap 63 Amp four pole including taking down old one Make Havells or equivalentin L&T/Schnieder |
| 128 | Supply and fix in repair off load change over switch415 volt 50 Hz confirm to IS-13947-3 with enclosure and side handle of cap 200 Amp four pole including taking down old one Make Havells or equivalentin L&T/Schnieder |
| 129 | Supply and fix in repair off load change over switch415 volt 50 Hz confirm to IS-13947-3 with SS enclosure and side handle of cap 630 Amp four pole, fixing to wall/panel including making existing connection complete all as specified and directed. Make Havells IHCCFE0630 equivalentin L&T/Schnieder |
| 130 | S & F in repair MCCB, 4 pole, 400 Amps, 415 Volts , 36 KA adjustable thermal and magnetic setting complete all as directed by Engineer-in-Charge including taking down old and unserviceable one. Make : HAVELLS, Model No. IHLLSEB40400 or equivalent model from /L&T/LEGRAND. |
| 131 | S & FMCCB enclosure suitable for 4 pole MCCB400 Amp fixing on wall/panel including shifting existing connections and necessary fixing arrangment to make the system functional complete all as specified and directed Make : Havells , model- IHELFP or equivalent in L& T /C&S |
| 132 | M & L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25m depth below ground level) with top edge of the plate not less than 1.5 m below ground level connected to galvanised earth strip of size 25x4mm by mean of bolt, nuts, check nuts and washer of galvanised iron steel all as shown in electrical plate No 3 of SSR Part - I, connected earthing test point and testing on complete all as specified and directed. |
| 133 | Supply & fixing in replacement of earth continuity conductor GI strip 25x4 mm complete all as specified and directed. |
| 134 | Taking down unserviceable/ burntoutalternator of DG set, capacity 7.5 to 15 KVA from the engine, rewinding the armature with the best quality super enamelled copper wires as per existing gauge and including insulation materials, tape, varnishing, heating the same upto rated tempaerature, includingrepair/remetaling of alternator shaft andlathe work, replacing ball bearing/bushes and coupling and refixing in position after repair including testing through authorised Original equipment manufacturer\"s service centre engineers or throuigh OEM certified agencies as approved by GE complete all as specified and directed by Engr-in-charge.Note: Test need to carry out by technician at site for confirming burnt out of field coil or armature in presence of Engr-in-charge. |
| 135 | All as per Serial Item No 70 here in before but of capacity 20 to 40KVA |
| 136 | All as per Serial Item No 70 here in before but of capacity 50 kVAto 62.5/63 KVA |
| 137 | All as per Serial Item No 70 here in before but of capacity 100 KVA to 125 KVA |
| 138 | All as per Serial Item No 70 here in before but of capacity 200 KVA |
| 139 | All as per Serial Item No 70 here in before but of capacity250 KVA |
| 140 | All as per Serial Item No 71 here in before but of capacity380/400 KVA |
| 141 | Supply and fix emergency push switch in repair including taking out old one complete all as specified and directed |
| 142 | M&L for servicing and cleaning of injector nozzel ofDG set of capacity63 KVA DG Set bydisconnection and opening of fuel injector assembly, carrying complete overhauling/servicing fuel injection system with including replacement of injector repair kit ,including calibration of injector, checking of pressure complete for each injector and re-assembling the same, testing for smooth opreation complete all as directed. |
| 143 | All as per Serial Item No 78 here in before but of size82.5/ 100 KVA |
| 144 | All as per Serial Item No 78 here in before but of size 125KVA to200 KVA |
| 145 | All as per Serial Item No 78 here in before but of size 250 KVA |
| 146 | All as per Serial Item No 78 here in before but of size 300 KVA to 400 KVA. |
| 147 | M&L forrepair to non functioning AMF panel for DG set for capacity upto 250 KVAcomplete by replacement of non functioning relay/Contactor/control wire/fuse etc to make AMF functional all as specified and directed. |
| 148 | All as per Serial Item No 83 here in before but of size 300 KVA to 400 KVA |
| 149 | Supply and fix radiator fan with blade in complete with fan drive of existing shape and size with fixing bolts,including taking out u/s fan drivefor 250 KVADG set |
| 150 | Supply and Fixing in repair Hand lock with Catcher for Canopy of DG Set and all as per directed |
| 151 | Supply and Fixing in repair SS hingefor Canopy (LHS/RHS door) ofDG Set and all as per directed |
| 152 | S & F, in replacement, higher crank power , high charge retention, superior spill resistant,12V, 180 AH DC electrical charge storage unit complete all as specified and directed. Note : Old Bty to deposited to store(Brand-Exide Express or equivallent inHBL/OKAYA) |
| 153 | Repair in re[placement62.5/100/ 125/250/400 KVA DG Engine control unit with KG 645 controller , interface and changing of faulty connector complete all as directed.Make : Kirloskar, Model : KG 645 or equivallent in Cummins/ Greaves |
| 154 | Material & labour for carefully dismentaling and taking out of turbo charger of DG set of30 KVA to 100 KVA capacity complete overhauling,servicing of turbo charger by replacement of turbo charger repair kit complete and re-assembling the same with new gaskets.Fit it to DG set properly in original position, checking the allignment, making proper all connection, testing for smooth opreation complete all as directed. |
| 155 | All as per Serial Item No 90 here in before but suitable for 125 KVA to250 KVA. |
| 156 | All as per Serial Item No 90 here in before but suitable for 300 KVA to 400KVA. |
| 157 | M & L for repair/Servicing of Governer Hydraulic/electronic type speed controller governer and calibrating complete including supply and replacement of repair kit for DG set of capacity of200 KVA to 400 KVA ofmakeGreaves/Kirloskar/Cummins complete all as sprecified and as directed. |
| 158 | Supply and filling of distilled water for filling in battery .Note: The Distilled water brought in sealed pack condition as per approved make. |
| 159 | M & L for repair of unserviceable charging alternator/Dynamo havingoutput of 12 Volts by rewinding inluding any other minor parts required all as specified and directed. |
| 160 | All as per Serial Item No 95 here-in-before but ofcharging alternator/Dynamohaving output of 24V all as specified and directed. |
| 161 | M & L for replacement of unsv thermostat sensor alongwith complete assy for DG set capacity upto 400 KVA including connection testing complete all as specified and directed. |
| 162 | Supply and fixing, in replacementof Old unserviceable water temp sensor for DG Set. |
| 163 | Supply and fixing, in replacementof Old unserviceable OIL Pressure sensor for DG System |
| 164 | Supply and installed Battery charger 12 & 24 volts output option suitable for 180 AHbattery complete all as specified and as directed. (Make : IRI or equivalent as approved) |
| 165 | M&L for carrying out repairing of DG setcontrol panel, by replacement of relay, contactor,MCB,fuse including rewiring faulty electrical circuit using 1.5 sqmm FRLS copper conductor, for DG Set of any type /make/capacity,making all electric connections and testing for smooth operation, complete all as dorected. (Note: Quoted rate is exclusive of CTs ,KW meter, volt meter , Ammeter are required, will be measured and paid seperately as supply only under relevant items) |
| 166 | Supply & fixing in replacement of CTs coil as per existing |
| 167 | S&F in replacement volt meter, 3 phase(0-500) volt of size 96 x 96 mm. |
| 168 | S&F in replacement Ammeter, 3 phase of size 96 x 96 mm. |
| 169 | M&L for radiator fan with fan drive of exisiting shpe and size with fixing bollts including taking out exisisting u/s fan drive suitable for 100 to 250 KVA DG set complete all as specified and directed. |
| 170 | Supply and fixing, in replacement radiator cap suitable for DG set of any type/ make and capacity complete all as specified and directed. |
| 171 | S & F 0.50 mm thick pre -painted galvalium aluminium zinc coating GI based corrugated steel colour sheet having tensile strength of 550 Mpa as in roof covering with self tapping screws complete all as specified and directerd. |
| 172 | S & F roof trusses (framed), trussed, purlins, crane gantries , rails and fastenings and heavy bracket framing (Beam, tee, angle, channel of flat sections) including diastance pieces, cleats etc with Fe-410-W(Gde - E-250) quality - B complete all as specified and directed. |
| 173 | S&F galvanised Iron pipe 50 mm bore (dia) \" Light Grade\" for protection of earth laid in floors/Road crossing , fixing to pole with mild steel clamps of suitable size and thickness,nuts,bolts etc. complete all as specified and directed. |
| 174 | Supply and fix in repair stopping solenoid 12Vfor75/82.5/100 KVA DG set. |
| 175 | Supply and fix in repair stopping solenoid12V for50/62.5 KVA DG set. |
| 176 | M&L for cement concrete PCC 1:3:6 type C-2 using 40 mm graded stone aggregate in filling fonundations and mass concrete complete including necessary form work foundation complete all as specified and directed. |
| 177 | M & L for repair/replacement of unserviceable digital electronic Controller starting /controller panel for any existing make ofDG Set for capacity upto 62.5/ 63 KVA complete all as directed. |
| 178 | M & Lfor top overhauling of200 KVA DG Set make : Kirloskar model No. 6SL1500TA by opening and dismantling Engine and transporting to auth worshop and removingof Cylinder head, cylinder liner, lubrication oil pump, pistons, connecting rods, piston rings, crankshaft, camshaft ,FIP, injector,turbo charger and other connectedparts foroverhaulingand replacing all unserviceable parts andreassemblying transporting the engine and accessories fromworkshop to work site including calibration of FIP,lath work of cylinder head,turbocharger and water pump, radiator repairing, testing and commissioningall as specified anddirected by Engineer-in-Charge. |
| 179 | Note :-(i)Spare parts shall be measured and paidseparately under respective item of this sch .(ii) The work shall be done as per OEM recommendation.(iii) Minor spare parts, which are essential for carrying out repair works but specifically not included in the description of item shall alsodeemed to be included in the unit rate.(iv) The rate quoted shall be deemed to be inclusive ofcleaning using chemicals, cutting, grinding, rematling, polishing, and lathe work required to any part of the engine(A)Supply only the following spare parts for capacityof 200 KVA DG Set |
| 180 | Piston Assy |
| 181 | Cylinder Liner Assy |
| 182 | Set of Joints |
| 183 | Set of O ring |
| 184 | Set of copper washer |
| 185 | Valve Seal |
| 186 | Cylinder head gasket 1.25 mm thick |
| 187 | Main Bearing |
| 188 | Connecting Rod Bearing |
| 189 | Bearing T/W |
| 190 | Inlet & Exhaust valve pair |
| 191 | Valve Guide |
| 192 | Valve Collete |
| 193 | Bearing Bush S/E |
| 194 | teflon oil Seal GE |
| 195 | Valve seatinsert inlet |
| 196 | Valve seatinsert Exhaust |
| 197 | Spin on filter |
| 198 | fuel filter element pre |
| 199 | fuel filter element micro |
| 200 | Engine Oil |
| 201 | Oil spray Assy |
| 202 | lube oil Pump |
| 203 | centrifuge filter 0.3 |
| 204 | water pump Assy |
| 205 | Connecting Rod |
| 206 | Injector |
| 207 | starter ring |
| 208 | tappet |
| 209 | Cylinder head bolt long |
| 210 | Cylinder head bolt short |
| 211 | rocker cover |
| 212 | thermostat element |
| 213 | sub Assy of vent tube |
| 214 | leak off pipe with flex element |
| 215 | Stop solenoid |
| 216 | AVR |
| 217 | hose radiator to water pump |
| 218 | Cogged belt AX44 or equivallent |
| 219 | Cogged belt AX 57 or equivallent |