| 1 | Taking down point wiring(light, fan, socket and power complete including fixtures andfittings such as switches ceiling roses, pendents , regulators, sockets etc. removing materials to store for keeping in safe custody for refixing or for taking credit (credit for above items should be made as per conditions separately) and making good distrubed surfaces of walls, floors, etc.complete all as specified and as directed by Engineer-in-Charge. |
| 2 | M&L Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC casing caping of suitable size with all accessories including PVC box /fabricated MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets,regulator etc or modular GI boxes of suitable sizes including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earthand connecting to earth dolly for one light or fanpoint controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan /call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.Note: Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. |
| 3 | All as per item No. 02 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge. |
| 4 | All as per item No. 02 here-in-before but one 3 pin 5 ampsswitch socket commbination on the independent board with other switch complete all as specified and directed by Engineer-in-charge. |
| 5 | M&L fo Point wiring surface type with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC casing caping with all fittings and accessories of casing caping(like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point (including supply & fixing of PVC boxes of suitable size /1.6 mm thick pressed mild steelterminal boxes of suitable size with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. or modular GI boxes of suitable size for mounting sockets for 5 pin, 16 Amp Switch socket combination on independent board complete all as specified and directed.Note: Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. |
| 6 | M&L fo Point wiring surface type with 4.0 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC casing caping with all fittings and accessories of casing caping(like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 4.0 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point (including supply & fixing of 1.6 mm thick pressed mild steelterminal boxes of suitable size with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. or modular GI boxes of suitable size for mounting sockets for 5 pin, 16 Amp Switch socket combination on independent board complete all as specified and directed.Note: Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. |
| 7 | M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium dutywith all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets,regulator etc or modular GI boxes of suitable size including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fanpoint controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Chase cutting deemed to be included in quoted rate. |
| 8 | All as per item No. 07 here-in-before but one 3 pin 5 ampsswitch socket commbination on the independent board with other switch complete all as specified and directed by Engineer-in-charge. |
| 9 | All as per item No. 07 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge. |
| 10 | M&L fo Point wiring surface type with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC concealed conduit with all fittings and accessories of conduit pipe(like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point (including supply & fixing of 1.6 mm thick pressed mild steelterminal boxes of suitable size with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. or modular GI boxes of suitable size for mounting sockets for 5 pin, 16 Amp Switch socket combination on independent board complete all as specified and directed.Note: Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board..(ii) Chase cutting deemed to be included in quoted rate. |
| 11 | S&F switch piano, flush type, Single pole one way, 5/6 Amps 230/240 Volts, white/ivory finish complete all as specified and directed. |
| 12 | S&FSocket outlet 3/5 pin, 6 Amps, 240 volt flushtype complete all as specified and as directed. |
| 13 | S&FSwitch socket combination multipurpose 2 in 1, 3 pin 6 Amps 230/240 volt flushtype complete all as specified and as directed. |
| 14 | S&F Switch socket combination multi - purpose 3 pin, 15 amp and , 5 amp controlled by one switch flush type complete all as specified and as directed. |
| 15 | Supply & fixing stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified . |
| 16 | S&FModular type switch6 Amps 230V AC single module one way complete all as specified and as directed. |
| 17 | S&F Modular socket out let 3 pin 10 Amps shuttered type 230V AC 2 module complete all as specified and as directed. |
| 18 | S&F Modular socket out let 3 pin 16 Amps shuttered type 230V AC 2 module complete all as specified and as directed. |
| 19 | S&FModular type switch16 Amps 230V AC single module one way complete all as specified and as directed. |
| 20 | S&F Modular type fan regulator Step type,100 Watt, one module/ two module, 230V AC complete all as specified and as directed. |
| 21 | S&F Modular bell push, 10 Amps 230V AC single module complete all as specified and as directed. |
| 22 | S&FCeiling rose, surface bakelite, 65 x 50 mm,three terminals complete all as specified and directed. |
| 23 | S&FBell/buzzer push 5/6 amps, flush type, white/ivory finish complete all as specified and as directed. |
| 24 | S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittingscomplete all as specified and as directed. |
| 25 | S&FCall bell, ding dongAC 230 volts, single pole completeall as specified and as directed. |
| 26 | S&F in repair switch piano, flush type, Single pole one way, 5/6 Amps 230/240 Volts, white/ivory finish complete all as specified and directed. |
| 27 | S&F in repair socket outlet 3/5 pin, 6 Amps, 240 volt flushtype complete all as specified and as directed. |
| 28 | S&Fin repair switch socket combination multipurpose 2 in 1, 3 pin 6 Amps 230/240 volt flushtype complete all as specified and as directed. |
| 29 | S&F in repair switch socket combination multi - purpose 3 pin, 15 amp and , 5 amp controlled by one switch flush type complete all as specified and as directed. |
| 30 | Supply & fixed in repair stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified . |
| 31 | S&F in repair Modular type switch6 Amps 230V AC single module one way complete all as specified and as directed. |
| 32 | S&F in repair Modular socket out let 3 pin 10 Amps shuttered type 230V AC 2 module complete all as specified and as directed. |
| 33 | S&F in repair Modular socket out let 3 pin 16 Amps shuttered type 230V AC 2 module complete all as specified and as directed. |
| 34 | S&Fin repair Modular type switch16 Amps 230V AC single module one way complete all as specified and as directed. |
| 35 | S&F in repair Modular type fan regulator Step type,100 Watt, one module, 230V AC complete all as specified and as directed. |
| 36 | S&F in repair Ceiling fan regulator electronic Step type, solid state, 240 volts,complete all as specified and as directed. |
| 37 | S&Fin repair Call bell, ding dongAC 230 volts, single pole completeall as specified and as directed. |
| 38 | S&F in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittingscomplete all as specified and as directed. |
| 39 | Supply and fixing in repair modular white cover plate with frame 2 modules complete all as specified and as directed. |
| 40 | Supply and fixing in repair modular white cover plate with frame 3 modules complete all as specified and as directed. |
| 41 | Supply and fixing in repairmodular white cover plate with frame 4 modules complete all as specified and as directed. |
| 42 | Supply and fixing in repairmodular white cover plate with frame 6 modules complete all as specified and as directed. |
| 43 | Supply and fixing in repair modular white cover plate with frame 8 modules complete all as specified and as directed. |
| 44 | Supply and fixing in repair modular white cover plate with frame 12 modules complete all as specified and as directed. |
| 45 | Supplying and fixing in repair two single core, 4 sqmm nominal cross sectional areamultistrandedcopper conductor FRLS cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including suitable size PVC casing and caping/conduit (ISI marked) including4 sqmm nominal cross sectional areamultistrandedcopper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earthwirecomplete all as specified. Note : Two run of 4 sqmm wire with one run of 4 sqmm and one run of casing capaing / conduit pipe shall be measured against one unit. |
| 46 | Supply and fixing in repair 18 W LED light fitting wall mounted batten 4\"ft ,minimumm lumen output 100 lumen/Wat, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6500K including necessary connection complete all as specified and directed. |
| 47 | Supply and fixed in repair 09 W LED light fitting wall mounted batten 2\"ft ,minimumm lumen output 100 lumen/Wat, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 09 watt,6500K including necessary connection complete all as specified and directed. |
| 48 | Supply and fixed in repair recessed/ surface mounted 2\" x 2 \" LED luminaireminimum 36 wattsminimumm lumen output 110 lumen/Watt, pre-treated CRCA frame powder coated with diffused Profied including necessary connection complete all as specified and directed. |
| 49 | Supply and fixed in repair security light fittings minimum 30 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete including 25mm dia light grade GI bracket with nut bolt and clamp complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed. |
| 50 | Supply and fixed in repair 12 W Surface panel mounted round LED downlight, aesthetically designed aluminium die-cast enclousers, with seperate replaceable constant current driver 12 watts, including necessary connection complete all as specified and directed. |
| 51 | Supply & fix in replacement of LED bulb 10 watt 6500 k complete all as specified and as directed. |
| 52 | Supply and fixing in repair LED 9 W decorative wall light made up of high grade engineering plastic material suitable for LED 9W complete as per manufacturer\"s instructions all as specified and directed. |
| 53 | Taking down and Refixing at site ceiling fans 1200/1400 mm sweep including opening of fans and cutting down burnt winding, and rewinding with new super enameled copper winding of same gauge as per existing winding, varnishing, drying, replacement of ball bearing, replacement of condenseretc and re-assembling the same including necessary transportation etc complete including taking down all as specified and directed. |
| 54 | Supply & fixing in repair of 3.15 Mfd Capacitor for Fan complete all as specified and directed. |
| 55 | Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed. |
| 56 | Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door, Triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed. |
| 57 | Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel ,neutral link and incoming contact complete all as directed. |
| 58 | Supply and fixed in repairsMCB SP,6 to 32 Amps, \"C\" series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed. |
| 59 | Supply and fixed in repairs MCB SPN 6-32 Amps,\"C\" series 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. |
| 60 | Supply and fixed in repairs MCB TPN 63 Amps,\"C\" series 10kA, 415 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. |
| 61 | Supply and fix in replacement of Surface mounting plastic box 4X4 inch size including all fixing accessories complete all as specified and directed. |
| 62 | Supply and fix in replacement of Surface mounting plastic box 4X7 inch size including all fixing accessories complete all as specified and directed. |
| 63 | Supply and fix in replacement of Surface mounting plastic box 8X6 inch size including all fixing accessories complete all as specified and directed. |
| 64 | Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased inand including 40 mm dia GI \"lightgrade\" pipe from upper end of earth plate upto equipments,20 dia bore GI pipe \"light grade\" as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I completeall as specified and directed and testing on completion. |
| 65 | NOTES:1.The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.2.The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule \"A\" notes for details. |