| 1 | Air ConditionerM&L for taking out u/s air conditioner window/ split type in capacity 1.5 TR and 2 TRfor replacing to u/s spare parts / carrying out neccessary repairing works/ shifting location/ gas re-filling etcin any make /modelall as site with connecting accessories from existing location after removing of all connections safely and transportation from site to work shop and back (if required)at same after repairing work complete all specified andas directed.Note :- (i) Connecting accessories will be taken in safe custody by contractor for re-using at same. (ii)All spare parts shall be measured and paid separatelyunder relevant items. |
| 2 | Supply and re- filling/ charging of refrigerant gas of R-134A,R-32, R-410A, R-22in original towindow or split type air conditioner upto 2 TR capacity with speicific pressure grade complete all as specified and asdirected.Note : Grade of refrigerant shall be supplied as permodel /make requirement in original. |
| 3 | Supply only rotary DC compressor unit for invertor window type cap upto 1.5 TR 230 V, Single Phase as required in origional manufactures complete all as specified and directed. |
| 4 | All as per item No 03 above butrotary DCcompressor unit for invertorsplit type cap upto 1.5 TR.230 V, Single Phase Complete all as specified and directed. |
| 5 | All as per item No 3 above but reciprocating / rotaryAC compressor unit for window type cap upto 2.0 TR.230 V, Single Phase Complete all as specified and directed. |
| 6 | All as per item No 3 above but reciprocating / rotaryAC compressor unit forsplit type cap upto2.0 TR.230 V, Single Phase Complete all as specified and directed. |
| 7 | All as per item No 3 but above but Starting/Running Capatior for Existing model of split/ window AC complete all as specified and directed. |
| 8 | Flushing and leak testing of complete system with Nitrogen gas and topping up compressor oil complete all as specified and directed. |
| 9 | M&L for servicing,oiling, greasing, cleaning, dusting ,overhauling etc all as site requirementfor air conditioner in all make/type/ model /cap upto 2 TR etcfor making serviceable with satisfactions including disconneting, removing, re-fixing ,and re-connecting complete all as specified and directed. |
| 10 | Water cooler/ refiregator and Deep- freezer :- Labourfor taking out u/s water cooler/ refrigerator and deep- freezerof any make/ model/ capacity etc for replacing to u/s spares /servicing/ carrying out neccessary repairing works/ shifting location/ gas re-filling etcin any type/ cap/ make /modelall as site with connecting accessories from existing location after removing all connections safely and transportation from site to work shop and back (if required)at same after repairing work complete all as specified and directed. Note :- (i) Connecting accessories will be taken in safy custody by contractor for re-using at same.(ii) All spare shall be measured and paid against respective items . |
| 11 | M&L for servicing,oiling, greasing, cleaning, dusting overhauling to water cooler/refrigerator and deep- freezerin any make/ model/ capacity etc complete all as site requirement works forin all make/type/ model /cap etcfor making serviceable with satisfactions including disconneting, removing, re-fixing ,and re-connecting all as same at siteand directed. |
| 12 | Supply only in replacement of compressore unit for 40 to 80 ltr storage capacity suitablefor refrigerator/ water cooler/deep- freezer in any capacity / make/ model/ type etcas site in origional manufactures complete all as specified anddirected.Note :-(i) All spares shall be hold original manufacture tag with cat no.(ii)Spare will be suitable for all capacity and MakeLG / Voltas/ Blue star/ Usha/ Vidiocon/ Usha/ Sumsang / Annapurna / whirlpool/ Gojrej/ Danfoss / Tecumseh etc as site. |
| 13 | All as per item No 12 but compressor unit for 80 to 150ltr storage capacity complete all as specified and directed. |
| 14 | All as per item No 12 but compressor unit for 165 to 250 ltrs capacity complete all as specified and directed. |
| 15 | All as per item No 12but compressor unit for 260 to 405ltr capacity complete all as specified and directed. |
| 16 | Taking down of old Submain wiring upto 10 sqmm any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed. |
| 17 | M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through PVC Conduit complete all as specified and directed. |
| 18 | All as per items No 17 above but 6 Sqmm complete all as specified and directed. |
| 19 | All as per items No 17 above but 4 Sqmm complete all as specified and directed. |
| 20 | Taking down MCB & DB from existing location with connection of any size and any type complete all as specified and directed. |
| 21 | Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , Tripplepole and neutral (TPN) 415 Volt , double door, suitable for 4 way with dim rail earth and neutral bar complete all as specified and directed. |
| 22 | S&F sheet metal enclosure for DB\"S 12 Way when MCBs to be used single pole neutral 240 Volts with 200 ABus Bar complete of following sizes complete all as specified and directed. |
| 23 | All as per items No 22 above but 8 Way complete all as specified and directed. |
| 24 | Supply and fixing in proper position MCB TPN 63 AMP capacity , 415 Volts with 10 kA breaking capacity complete all as specified and directed. |
| 25 | S&F MCB Single pole and neutral 240 Volt 20 to 40 Amp capacity complete all as specified and directed. |
| 26 | S&F MCB Single pole 240 Volt 6 to 32 Amp capacity complete all as specified and directed. |
| 27 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including provision of fan hook complete all as specified and directed |
| 28 | M&L complete for pvc exhaust fan of size 250 mm sweep, single phase,230volts Ac with louver shutter /grill and connection complete incl cutting hole and making good disturbed surface and necessary fixing arrangements complete all as specified and directed. |
| 29 | M&L complete for metal body exhaust fan of size 300 mm sweep, single phase,230 volts Ac with louver shutter /grill and connection complete incl cutting hole and making good disturbed surface and necessary fixing arrangements complete all as specified and directed. . |
| 30 | Supply & Fix electric storage heater of 25 Ltr capacity, 5 Star in replacement with heating element 2000 W,thermostat, inlet, outlet connection pipe and air vent connections including all fixing arrangement for mounting on wall and necessary water inlet and outlet connections complete all as specified and directed. |
| 31 | Supply and fixingwall mounting hi-flow and heavy duty fan with all accessories of Size 400 mm sweep, 230 volt Acwith connection from existing celing roseall as specified and as directedMake :- Crompton/Polar/Havells/Bajaj. |
| 32 | Supply and fix Chimney Faber 90 cm, 1500 cum/hr Auto- Clean curved glass kitchen Chimney including necessary fitting and cutting/hole in roof/wall suitable size complete all as specified and directed. |
| 33 | S&F metal clad socket out let with MCB single pole and nutral 20-32 Amp, 240 V including sheet metal enclosure complete fixed on flat iron 32x6 mm or 2nd class hard wood wooden board including complete electrical connection by proper size of copper lugs complete all as specified and directed. |
| 34 | Excavation in trenches, in any type of soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth , laying of cable or pipes (where provided for protection of cable) etc and getting out trimming the sides, forming bottom surfaces to required level complete all as specified and all as directed. |
| 35 | M&L for 40 mm dia GI tubing light grade with all necessary fittings laid in trenches, fixed to walls/ poles/ under road/ floor etc for cable protection, complete all as specified and directed. |
| 36 | M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated ( punned) upto 180mm thickness, complete all as specified and directed. |
| 37 | Supply and laying of well burnt bricks, sub class \"B\" laid flat in trenches for protection of cable complete all as specified and directed. |
| 38 | Returning and filling including spreading, levelling, watering and well rammingin layers not exceeding 25 Cm thick complete all as specified and directed. |
| 39 | Removing of surplus soil to a distance not exceeding 50 Mtrs and depositing where directedat a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 40 | Supply /laid/ fixing/ connecting and testing in replacement ofthe following LT under ground XLPE insulated ,armoured heavy duty electric power cable with aluminium conductor , 1100 volts grade (earthed) cross section area 95 Sqmm x 3.5 core complete all as specified and directed. |
| 41 | All as per Item No-40 but for 50 Sqmm x 3.5 core complete all as specified and directed. |
| 42 | All as per Item No-40 but for 25 Sqmm x 4 core complete all as specified and directed. |
| 43 | All as per Item No-40 but for 16 Sqmm x 4 core complete all as specified and directed. |
| 44 | Supply and fixing and connecting in replacement of fully automatic single phase naturally air cooled indoor type wall mounting type digital voltage stabilizervoltage variation between 130 to300 voltswith output voltage stabilizer at 230 v with accuracyof +/- 2.5% of capacity 5 KVA(suitable up to 2 Ton or 24000 Btu/Hr) W TDR complete all as specified and directed. |
| 45 | All as per item No 44 but of capacity 4 KVA(suitable up to 1.5 Ton or 24000 Btu/Hr) W TDR complete all as specified and directed. |
| 46 | M & L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.5 of SSR Part I and including testing on completion all as specified locations and as directed by the Engineer-in-Charge.Note: 1.The above quoted rate shall include cost of main earthing lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia light grade GIwater pipe including GI protection pipe 40mm dia light grade for earth strip etc.2. The cost of earth pit is deemed to be included in the unit rate. |
| 47 | Supply, install, testing & commissioning of LTPanel CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15mm thickness, angle iron of size 40X40X6mm thick of length 0.9 m from pcc, frame work and tee section (frame) of suitable sizedouble door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and makingcomplete including PCC foundation 800 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and complete with internal wiring with the following items :-(A) I/G : - MCCB 4 pole,250 Amps, breaking capacity 36 kA .microprocessor type - 01 Nos (B) O/G : - MCCB 4 pole,100 Amps, breaking capacity 25 kA . - 03 Nos (C) O/G : - Changeover 250 Amp 415 volt 4 Pole - 01 Nos (D)Three Ph Digital Volt Meter(0-500)Volt with selector switch. - 01Nos(E) Three Ph Digital Ammeter with CT\"s with appropriate Ratio along with selector switch. - 01 Nos(F) Digital frequency meter 40-60 Hz.-01 Nos(G) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set |
| 48 | NOTES:1.The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.2.The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule \"A\" notes for details. |