| 1 | Supply only High strength Calcium based granular chlorination chemical as per IS: 10500: 2012 for treated and disinfectant water of following specifications for Water treatment in sealed packing of 45 Kgs HDPE Jars to MES store yard as directed by Engr-in- Charge. Make : Altoch GP/Rayalseema/Aquafit or as approved by E-In-Cs Br /Zonal CEs.:(a) Chemical analysis & physical observations: (i) Description: Whitish granules (ii)Granular size (Mesh passing through - 100 BSS): 1.1 (± 0.1) % (iii)Water / moisture: 5.00 (± 0.2) % (iv)Other insoluble Calcium salts: 1.1 (± 0.1) % (v) Mercury & other Heavy Metal contaminants: BDL (vi)The chlorination chemical must contain appropriate quantities of dispersants / corrosioninhibitors to prevent encrustation / scaling in distribution systems.(b) Strength in terms of quantity of chlorination chemical required to obtain free chlorine of 1 ppm per lakh liters of water requirement must be 140 - 160 gm per one lakh liter of water to achieve 1 ppm Av. Cl. at injection point ( contains not less than 60 to 70% active chlorine ).(c) Stability: Projected shelf life of chlorination chemical must be one year with minimal loss of chlorine.(d) Handling of chlorination chemical for regular chlorination:(i) Operational considerations: Must be safe to use in terms of level of insoluble components. There must be no risks relating to encrustations in equipment and pipelines, no sludge generation, no hard water scaling in supply water. (ii) Operator health considerations: Chlorination chemical must contains acceptable levels of granular size to avoid risks to operators from health safety point of view. |
| 2 | Notes for item No. 1:(i)Supply shall be made by the contractor based on the reuirement / piecemeal manner as directed by the AGE E/M and shall be delivered in the store yard of AGE E/M. No claim whatsoever on account of extra charges of transportation shall be entertained by the Deptt.(ii)Contractor shall provide the original purchase vouchers alongwith test certificate of entire quantity of each lot at the time of delivery.(iii) Testing of every lot ofHigh strength Calcium based granular & Bleaching powder shall be gotcarried out by the contractor from NABL accreded lab at his own cost and report shall be submitted to Engr-in-Charge.(iv) Material shall be brought by the contractor in packed plastic containers/baggs as per OEM packing in sealed position.(v) The brand and make of the chlorination chemical must be recommended and certified by All India Institute of Hygiene & Public Health (Govt. of India), confirming compliance to all the above specifications with a declaration from the laboratory that from the technical, strength, stability, health, safety, and operational point of view, as well as the fact that this product is used for drinking water applications for consumption by humans, the brand and make of Calcium based granular chlorination chemical, bleachig powder & Ferric Alum are suitable for drinking water chlorination and are recommended for use. |
| 3 | Material and labour for disconnecting of monoblock pump set and motor of capacity up 0.5HP to 1HP, burnout winding wire, servicing and repairing/ replacement of impeller, shafts, shafts keys, bushes, fan blade, replacement of burnout winding wire with new winding wire of same gauge, cotton tape, varnish, ball bearing, bushes, gland packing, rubber gasket, capacitor, nuts & bolts complete and refixing the same on MS base frame on place and connecting to MS/GI piping line testing and commissioning all as specified and directed. Note: Rates for opening, transportation to workshop & back after necessary repairing works required such as welding, grinding and chamfering be included in the items rates. |
| 4 | Material and labour for disconnecting of monoblock pump set and motor of capacity2 HP, burnout winding wire, servicing and repairing/ replacement of impeller, shafts, shafts keys, bushes, fan blade, replacement of burnout winding wire with new winding wire of same gauge, cotton tape, varnish, ball bearing, bushes, gland packing, rubber gasket, capacitor, nuts & bolts complete and refixing the same on MS base frame on place and connecting to MS/GI piping line testing and commissioning all as specified and directed. Note: Rates for opening, transportation to workshop & back after necessary repairing works required such as welding, grinding and chamfering be included in the items rates. |
| 5 | Taking out centrifugal electric5 HP Motor3 phase, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed. Note- All T&P required shall be supplied by contractor without extra cost. |
| 6 | Taking out centrifugal electric7.5 HP Motor3 phase, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed . Note- All T&P required shall be supplied by contractor without extra cost. |
| 7 | Taking out centrifugal electric10 HP Motor3 phase, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed . Note- All T&P required shall be supplied by contractor without extra cost. |
| 8 | Taking out centrifugal electric25 HP Motor3 phase, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed . Note- All T&P required shall be supplied by contractor without extra cost. |
| 9 | Taking out centrifugal electric40 HP Motor3 phase, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed . Note- All T&P required shall be supplied by contractor without extra cost. |
| 10 | Taking out centrifugal electric50 HP Motor3 phase, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed . Note- All T&P required shall be supplied by contractor without extra cost. |
| 11 | Taking out centrifugal electric100 HP Motor3 phase, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed . Note- All T&P required shall be supplied by contractor without extra cost. |
| 12 | Dismantling the Monoblock centrifugal Pump assembly any type or make for carrying out repair and replacement of worn out parts by strip opening of all parts such as impellers, pump shafts, lock collers, bearing/ bushes, gland rings , nuts & bolts etc and machine work such as welding turning, re-facing where required and replacing of defective parts up to pump capacity of 100 HP. |
| 13 | Dismantling the Monoblock centrifugal Pump assembly any type or make for carrying out repair and replacement of worn out parts by strip opening of all parts such as impellers, pump shafts, lock collers, bearing/ bushes, gland rings , nuts & bolts etc and machine work such as welding turning, re-facing where required and replacing of defective parts up to pump capacity of 50 HP. |
| 14 | Dismantling the Monoblock centrifugal Pump assembly any type or make for carrying out repair and replacement of worn out parts by strip opening of all parts such as impellers, pump shafts, lock collers, bearing/ bushes, gland rings , nuts & bolts etc and machine work such as welding turning, re-facing where required and replacing of defective parts up to pump capacity of 40 HP. |
| 15 | Dismantling the Monoblock centrifugal Pump assembly any type or make for carrying out repair and replacement of worn out parts by strip opening of all parts such as impellers, pump shafts, lock collers, bearing/ bushes, gland rings , nuts & bolts etc and machine work such as welding turning, re-facing where required and replacing of defective parts up to pump capacity of 15 to 25HP. |
| 16 | Supply and fix rubber Insertion Sheet flange of thickness 4mm where required as per site requdirement, including cutting and making holes of sutable size complete all as specified and directed. |
| 17 | Supply and fix rubber coupling suitable for up to 25 HP motor including CI outer coupling and nuts & bolts including machiningwork for making shaft size complete all as specified and directed |
| 18 | Supply and fix rubber coupling suitable for 40 HP to 100 HP motor including CI outer coupling and nuts & bolts including machiningwork for making shaft size complete all as specified and directed |
| 19 | Supply and fix Star coupling including CI nuts andbolts suitable up to 15 HP Motors complete all as specified and directed. |
| 20 | Taking down existing old Non returning valve and supply and fix new NRV of size 150mm dia for suction complete all as specified and directed. |
| 21 | Taking down existing old Non returning valve and supply and fix new NRV of size 100mm dia for suction complete all as specified and directed. |
| 22 | Taking down existing old Stainer Valve and supply and fix new Stainer Valve of size 150mm dia for suction complete all as specified and directed include replacement of rubber sheet and nuts and bolts. |
| 23 | Taking down existing old Stainer Valve and supply and fix new Stainer Valve of size 200mm dia for suction complete all as specified and directed include replacement of rubber sheet and nuts and bolts. |
| 24 | Taking down existing old Stainer Valve and supply and fix new Stainer Valve of size 100mm dia for suction complete all as specified and directed include replacement of rubber sheet and nuts and bolts. |
| 25 | Repairing of existing starter/panel by disconnecting existing burn out cable/ wiring complete and replaced with 1.5 Sqmm single core copper conductor or suitable size as per existing cable include replacement ofDigital Volt meter, Digital Amp Meter alongwith CTs, relays, making connection, replacement of cable lugs of suitable size, repair/replacement of locking arrangement include painting with two coat of synthetic enamel paint complete all as specified and directed. Note : Repalcement of contractor, relay, MCCBs will be measured and paid seperately. |
| 26 | Material and labour forMCB SP LT 230 volt 50 Hz, C Series AC 16-32 Amps 16 KA with thermal magnetic release for OL and SC protection complete all as specified and directed. |
| 27 | Material and labour for MCB TPN LT 415 volt 50 Hz, C Series AC 16-32 Amps 16 KA with thermal magnetic release for OL and SC protection complete all as specified and directed. |
| 28 | Material and labour for MCB TPN LT 415 volt 50 Hz, C Series AC 40-63 Amps 16 KA with thermal magnetic release for OL and SC protection complete all as specified and directed. |
| 29 | Material and labour forMCCB TP NL LT 415 volt 50 Hz, AC 63 amps 25 KA with thermal magnetic release for OL & SC protection complete all as specified and directed. |
| 30 | Material and labour for MCCB TP NL LT 415 volt 50 Hz, AC 125 amps 25 KA with thermal magnetic release for OL & SC protection complete all as specified and directed. |
| 31 | Material and labour for MCCB TP NL LT 415 volt 50 Hz, AC 630 amps 50 KA with thermal magnetic release for OL & SC protection complete all as specified and directed. |
| 32 | Material and labour MCCB TP NL LT 415 volt 50 Hz, AC 250 amps 25 KA with thermal magnetic release for OL & SC protection complete all as specified and directed. |
| 33 | Supply only Thermal Over load relay ofrating 10- 40 Amps, 415 Volts, complete all as specified and directed |
| 34 | Supply only Thermal Over load relay ofrating 20- 63 Amps, 415 Volts, complete all as specified and directed. |
| 35 | Material and labour for replacement of watering pipe of 1 mtr length 8mm dia PVC threaded pipe both end nuts as per sample. |
| 36 | Supply and fixsubmersible flat cable of size 6 Sqmm 3 core 1100 volt grade copper conductor conforming to IS 694/1990 with latest ammendments from starter to motor complete all as specified and directed. |
| 37 | Supply and fixSubmersible flat cable of size 10 Sqmm 3 core 1100 volt grade copper conductor conforming to IS 694/1990 with latest ammendments from starter to motor.complete all as specified and directed. |
| 38 | Supply and fix in repair single corecable with copper conductor PVC round sheathed (flexible) industrialcable of size 16 Sqmm 1100 volt grade copper conductor conforming to IS 694/1990 with latest ammendments from starter to motor. complete all as specified and directed. |
| 39 | Supply and fix in repair single corecable with copper conductor PVC round sheathed (flexible) industrialcable of size 10 Sqmm 1100 volt grade copper conductor conforming to IS 694/1990 with latest ammendments from starter to motor.complete all as specified and directed. |
| 40 | Supply andFix in repair Automatic Mains failure Panel (AMF) AMF panel suitable for 200 KVA DG Set fabricated out of sheet steel 2.0 mm thick indoor type factory made suitable for floor mounting hinged from panel for easy asessibility with suitable rated bus bar internal wiring and with provision for connecting incomming/outgoing and bypass system and leads with the folowing accessories :-(a) HRC fuse ( - 06 Nos) of proper rating for Both in coming + MCCB 100 Amps4 pole - (02 Nos-) for incoming (b) Auxillary contactors 100 Amps ,415 Volt , 3 Phase, 4 Pole with timer (on delay)- 02 Nos (c) Voltmeter digital of range 0 to 500 Volt, AC with selector switch - 01 No (d) Ammeter digital of range 0 to 200 Amps with selector switch - 01 No ( e) Frequency meter digital with selector switch - 01 no (f) Powerfactor meter digital type - 01No (g) Twoset of indicator lamps 6 Nos LED Type for main and DG indication (h) Master switch for auto/manual/test/off (j) One set of lamps for indicating \"load on set\" \"load on mains\"set fails to start\" low oil pressure\" high cylinder tamp\" \" battery low\" (k) Alarm/Hooter (l) Bty charger connected to main supply side to charge bty comprising the following :-(m) DC ammeter & voltmeter digital type (n) Charge rate selection for trickle or high charge (o) Indicator lamp for bty (p) Set for easily accessible control fuses (q) Set for relays to auto-start the engine on main failure and low voltage.(r) Emergency trip etcNote: Quoted rate is inclusive for the following:-(i) any fittings/fixtures which are necessary for properfunctioning of the DG set/AMF Panelshall also be deemed include in the unit rate quoted and shall be provided by the contractor without any extra cost to the Deptt.(ii)Drawings/cataloge for AMF Panel of DG Set got approved by the Accepting Officerbefore ordering to the manufaturer.(iii) PCC for fixing arrangement if reqd at site. |
| 41 | All as peras item No 111, but 160 KVA |
| 42 | All as peras item No 111, but 100 KVA |
| 43 | Supply and fix in repair Water Level ControllerPCB-5 Level. Voltage - 5 V DCMake:- SPLASH/RDS/ICS |
| 44 | Supply and fixin repairWater Level ControllerPCB-10 Level. Voltage- 5 V DCMake:- SPLASH/RDS/ICS |
| 45 | Supply and fixin repairSolenoid Valve10mm/15mm/25mm 230 VAC. Direct acting/Pilot Operated complete all as specified and directed .Make: ROTEX/AVCON/JOHNSON CONTROLS/ DANFOSS |
| 46 | Supply and fixin repairCoil for Solenoid Valve 10mm/20mm 230 V AC.complete all as specified and directed . |
| 47 | Supply and fixin repair electronic Pressure switch 0-10 Kg/sqcm , as existing230V, 50Hz complete all as specified and directed |
| 48 | Supply and fixin repair Electric motor typeSynchronous, Input Voltage - 230 V AC, suitable for actuator of size 100 mm dia. complete all as specified and directed . |
| 49 | Supply and fixin repairElectric motor typeSynchronous, Input Voltage - 230 V AC, suitable for actuator of size 150 mm dia complete all as specified and directed |
| 50 | Supply and fixin repairElectric motor typeSynchronous, Input Voltage - 230 V AC, suitable for actuator of size 200 mm dia complete all as specified and directed . |
| 51 | Supply and fix Electric motor typeSynchronous, Input Voltage - 230 V AC, suitable for actuator of size 300 mm dia complete all as specified and directed . |
| 52 | Supply and fix MSspiral gear for gear box or actuator for Butterfly valve of size 100/150/200/250/300 mm dia complete all as specified and directed . |
| 53 | Supply and fix MSsectorgear for gear box or actuator for Butterfly valve of size 100/150/200/250/ 300 mm dia complete all as specified and directed . |
| 54 | Supply and fix Butterfly valve for rating 10 kg/sqcm, Disc material,CI with nylon coating, operating angle - 90 degrees of size 100 mm dia complete all as specified and directed . |
| 55 | Supply and fix Butterfly valve for rating 10 kg/sqcm, Disc material,CI with nylon coating, operating angle - 90 degrees of size 150 mm dia complete all as specified and directed . |
| 56 | Supply and fix Butterfly valve for rating 10 kg/sqcm, Disc material,CI with nylon coating, operating angle - 90 degrees of size 200mm dia complete all as specified and directed . |
| 57 | Supply and fix Butterfly valve for rating 10 kg/sqcm, Disc material,CI with nylon coating, operating angle - 90 degrees of size 250 mm diacomplete all as specified and directed . |
| 58 | Supply and fix Motorized actuator without motor suitable for 150 mm/200mm dia size Butterfly valve, Protection - IP 65 with Space Heater, Local Position Indicator, Adjustable mechanical stoppers complete all as specified and directed . |
| 59 | Supply and fix Motorized actuator without motor suitable for 250/300 mm dia size Butterfly valve, Protection - IP 65 with Space Heater, Local Position Indicator, Adjustable mechanical stoppers. complete all as specified and directed . |
| 60 | Supply and fix Capacitorfor Actuator suitable for 50/80/100/150/200/250/300mm dia Butterfly Valve of capacity 3.5 Mfd/6 Mfd/8 Mfd complete all as specified and directed . |
| 61 | Supply and fix Resistor(R C Circuit) for Actuator suitable for 50/80/100/150/200/250/300 mm dia Butterfly Valve with capacity 470 Ohms, 100 Watt/235 Ohms, 200 W/100 Ohms complete all as specified and directed . |
| 62 | Supply and fix Limit switch for Actuator suitable for100/150/200/250/300mm dia Butterfly Valve complete all as specified and directed . |
| 63 | Supply and fix SMPS input230 V/AC, Output 24V DC, rating 5 Amp complete all as specified and directed . |
| 64 | Supply and fix Selector switch 2 Pole, 2 Position/3 Position contact rating 6 A/230 V AC complete all as specified and directed . |
| 65 | Supply and fix joint kit complete all as specified and directed . |
| 66 | Supply only Inorganic polymerised liquid primary coagulant for drinking water tretment with the following specifications:- (a)Appreance : Clear to slight hazy liquid (b)Odour : odourless (c) Specific gravity : 1.3300-1.3500, (d)pH (30%) : 4.00-4.40 (e)Evaporation rate : 50-75% (Water) (f) Viscosity< 50cps complete all as specified and directed . |
| 67 | Supply only aluminum sulphate (Alum ferric) grade II superior quality suitable fortreatmentof drinking water in the form of solid lumps of 20 kgs. Complete all as specified and as directed. |
| 68 | Checking of Dosing Pump regurlarly basis for a period of six months installed at different locations for entire period of completion for smooth fucntioning of plants, find out defect and rectify the defect immediately when found in plants all specified as directed for complete contract period. Dosing pump will be any make & model as existing completeNote :-(i)Spare parts shall be ,easured and paid for separately.(ii) In case, payment shall be made in part period, rate shall be worked out on proportional basis |
| 69 | Supply and fix as in repairs 20mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches with all fittings fixed to walls complete all as specified and directed . |
| 70 | Taking down / up unserviceable XLPE LT cable of size up to 400 Sqmm 3-1/2core complete all as specified and directed. (Note: Earth work to be measured and paid under relavent item of this schedule) |
| 71 | Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade corss-sectional area 400 Sq mm 3.5core complete all as specified and directed. (Note: Excavation & Thimbles to be measured and paid under relavent items of this schedule) |
| 72 | Supply and fixing in repair water tight IP-66 swimming pool LED water proof light fittings Metal body LED light fittings 15W, 12V DC complete having CE certification include making connection with water proof wire alongwith driver as existing complete all as specified and directed. |