Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | E/M PORTION |
| 2 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, taking out/alying UG cableetc. n exc 10 sq m on plan and n exc1.5 m in depth and getting out in soft/ loose soilcomplete all as specified & directed. |
| 3 | Excavating in trenches. n exc 1.5 m wide anddepth exc 1.5m and not exc 3m, for foundation, etcn exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and as directed. |
| 4 | Returning filling in including spreading, levelling, watering and well ramming in layers notexceeding 25 cm thick in soft/loose soil, completeall as specified and directed. |
| 5 | Removing excavated surplus materials (Soils) to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 6 | Supply and layingdry river sand cushioning for cable protection with a layer of 8cm deep before laying and 15cm after layinggentlypunned down to 10 cm on top of the cable as per SSR Part-I complete all as specified and as directed. (Note : Punned thickness shall be measured). |
| 7 | Material and Labour for bricks common burnt clay, building brick, sub class B designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed. |
| 8 | Supply, laying, jointing including testing in replacement, connecting, testing and commissioning of LT under ground cable sectional area 240Sqmm x 3.5 Core, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed :Note : Manufacturer\"s test certificate shall be submitted alongwith RAR/FB to Engr-in-Charge. |
| 9 | Supply, laying, jointing including testing in replacement, connecting, testing and commissioning of LT under ground cable sectional area 25Sqmm x 3.5 Core, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed. |
| 10 | Supply, laying, jointing including testing in replacement, connecting, testing and commissioning of LT under ground cable sectional area 16Sqmm x 4.0 Core, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed. |
| 11 | Material & labour for making hole by suitable means for insertion of GI pipe 80 mmbore for passing cable across the road withoutcutting the road complete all as specified& directed. |
| 12 | Supply fixing as in repair steel tubular swaged pole 9.00m long Type -410 SP-31 conforming to IS-2713 part I to III 1980 with and including cast iron base plate, finial taper plug,nuts, bolts and washers etc. and fixed into plain cement concrete foundation duely painted with two coats of aluminium paint over one coat of red oxide primer including preparetion of surfaces and making strip 150mm wide upto 1.50m( above PCC coping) by black, yellow paint in alternate layers and pole nos.including dismantling of old poles of any descriptionincluding demolition of concrete foundation complete all as specified and directed. NOTE: Earth work, cement concrete will be measured and paid seperately. |
| 13 | M&L for PCC 1:3:6 type C-2using 40 mm graded stone aggregate as in foundations, filling and mass concrete etc complete all as specified and as directed. |
| 14 | M&L forPCC 1:2 :4 type B-1 using 205 mm graded aggregate as in leveling course inroof padding etc complete all as specified and as directed. |
| 15 | Material and labour for 80mm bore galvanized mild steel/ tubes, \"light grade, complete with all fittings; fixed to poles for protection of cable from junction box to street light with mild steel clamps, bolts, nuts and washersas required for pipe for fixation of pipe alongwith pole complete all as specified and as directed. |
| 16 | Material and labour for timer switch, 250 volt, single phase, 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed. |
| 17 | Supply and fixing in repair PVC insulated and PVC round sheathed, copper conductor industrial cable 2.5Sqmm, three core of copper conductor for connection of street light/ flood light/ posttop lantern/ garden light etcfittings on pole/wall/ pillar from over head conductor/ junction box/ DB including termination clip etc complete in all respect including through GI pipe of size 15/20mm dia complete all as specified and as directed. |
| 18 | Supply and fixing as in repair LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 19 | Supply and fixing in replacement Cable Junction Boxes IP 66 “halogen free and weather proof” for outdoor installation (with metric knockouts for cable entry - Black Colour) size 200 x 160 x 98 mmsuitable for 16/25 sq.mmfixed to pole /wall with suitable FI clamp 20X3 mm nuts , bolts and washers including provision of 01 No miniature circuit breaker (MCBs) single pole , 240 volts 10 KA 10 Amps and includingsuitable capacity aluminium bus bar (minimum 100Amps-04Nos) mounted on insulator complete all as specified and as directed, Note: Quoted rate deemed to be included taking down of old UNSV junction box and depositing to MES store yard. |
| 20 | Supply, installation, testing and commissioning of LT Panel board, TPN 415 Volts, 50 Hz,out door cubical type floor mounted CPRI approved factory made,double doordust and vermin proofIP-54, fabricatedout of CRCA sheet not less than 3.15 mm thickwith 2mm thick for internal compartment duly powder coated fixed on angle iron pedestalmade out of 50x50x6 mm with cable chamberfor individual feeders for incommingand outgoing connections,one set of LED indicator lampRYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley aluminium bus bar suitable for carrying of current 400 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB\"s (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator ITEM CINTINUED AS 20.01 |
| 21 | ITEM CONTINUED FROM 20.00including necessary PCC foundation of minimum 0.50 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :- (a) MCCB 400 Amps 4 Pole 50 Hz 415 V with thermal magnectic& adjustable Magnetic type capacity 36 KA - 1Nos (Incoming). (b) MCB 250 Amps 4 pole, 50 Hz, 415 Volt ith adjustable thermal & Fixed magnetic type, 36 KA - 01 Nos (Outgoing).(c)MCB 160 Amps 4 pole, 50 Hz, 415 Volt ith adjustable thermal & Fixed magnetic type, 36 KA - 02 Nos (Outgoing).(d) 3Ph digital multi function meter modelA, class 1, 5A with relay Vega Series - 1Nos(e) Indicating lamp 240 volts LED type - set of three. |
| 22 | Supply, installation, testing and commissioning of LT Panel board, TPN 415 Volts, 50 Hz,out door cubical type floor mounted CPRI approved factory made,double doordust and vermin proofIP-54, fabricatedout of CRCA sheet not less than 3.15 mm thickwith 2mm thick for internal compartment duly powder coated fixed on angle iron pedestalmade out of 50x50x6 mm with cable chamberfor individual feeders for incommingand outgoing connections,one set of LED indicator lampRYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley aluminium bus bar suitable for carrying of current 400 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB\"s (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulatorITEM CONTINUED AS 21.01 |
| 23 | ITEM CONTINUED FROM 21.00 including necessary PCC foundation of minimum 0.50 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :- (a) MCCB 400 Amps 4 Pole 50 Hz 415 V with thermal magnectic& adjustable Magnetic type capacity 36 KA - 1Nos (Incoming). (b) MCB 160 Amps 4 pole, 50 Hz, 415 Volt ith adjustable thermal & Fixed magnetic type, 36 KA - 01 Nos (Outgoing).(c)MCB 63 Amps 4 pole, 50 Hz, 415 Volt ith adjustable thermal & Fixed magnetic type, 36 KA - 03 Nos (Outgoing).(d) 3Ph digital multi function meter modelA, class 1, 5A with relay Vega Series - 1Nos(e) Indicating lamp 240 volts LED type - set of three. |
| 24 | Material and labour for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SI Part I all as specified and testing on completion includingprovisionof earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work, PCC pit with RCC cover, char coal, salt, funnel etc including taking down old earthing complete all as specified and as directed.Note:- Rate quoted by tenderers shall be deemed to include for following provisions-ITEM CINTINUED AS 22.01 |
| 25 | ITEM CONTINUED FROM 22.00[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 m. [ii].PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore medium grade & copper lugs, charcoal & salt as reqd .[v]. GI protection pipe of size 15 mm bore light grade 7.5m. |
| 26 | Supplying, installing, commissioning and tastingin repair factory made outdoor type LT Kiosk box with canopyof size 1000mmx600mmx450mm made out of 3.15mm thick CRCA sheet duly powder coatedwith 4 nos 300 Amps copper busbar and 4 nos Mild steel legs of size 40mmx40mmx5mm of length 1000 mmand locking arrangement with one Nos of MCCB of 160 Amp 4 pole 36 KAas incomming includinggroutingin PCC 1:3:6 type C-1complete all as specified and directed. |
| 27 | Supply and fixing House service bracketcomplete with 1.5m long G.I. pipe 40mm dia light. grade, two nos 90/45 degreebends, M.S.hook and stay or guy and fixed with 25mm x 4mm MS flat with necessary nuts, bolts, washers etc, as required and painting with two coats of synthetic enamel paint over a coat of primer and fixed to pole complete all as specified & as directed. |
| 28 | Supply and fixing PVC tank, double layer of capacity 5000 ltrs for collection tank, sedimendation tank, filteration tank and clean water tank for rain water harvesting and including necessary fittings and fixtures complete all as specified and as directed. |
| 29 | Supply and fixing 3- layer PP-R (Polypropylene random copolymer) pipes 40 mm outer dia ,SDR 11 (PN-10)UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random, jointing complete including laid in trenches/floor at places where directedcomplete all as specified and directed. |
| 30 | Supply and fixing PP-R (Polypropylene random copolymer) ball valve (brass inlet) for 40mm bore pipe complete all as specified and directed. |
| 31 | Supply, installation, testing and commisioning of2.5 HP/1.1 KW, 230 volt, 50 Hz, 1500 RPM water pump and motor including necessary fittings and fixtures complete all as specified and as directed. |
| 32 | M&L for pebbles matte gravel for water filtration solid packing type complete all as specified and as directed. |
| 33 | M&L for filling of gravel in tank for filtration of size 6mm to 10mm upto height of 0.5m and including all necessary materials complete all as specified and as directed. |
| 34 | M&L for filling of gravel in tank for filtration of size 2mm to 4mm upto height of 0.5m and including all necessary materials complete all as specified and as directed. |
| 35 | M&L for filling of black hardwood charcoal for water filtration 0.5 mtr and including all necessary materials complete all as specified and as directed. |
| 36 | M&L for supply and fixing / Laying in replacement, connecting, testing and commissioning of LT under ground cable sectional area 10Sqmm x 4.0 Core, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed. |
| 37 | Material and labour for 50mm bore galvanized mild steel/ tubes, \"light grade, complete with all fittings; fixed to poles for protection of cable from junction box to street light with mild steel clamps, bolts, nuts and washers complete all as specified and as directed. |
| 38 | Supply and fixing factory made board distribution in sheet steel enclosure double door glazed with 200 Amps ratedbus bar, SPN, 4 ways, 240 Volts suitable for housing MCBs.complete all as specified and as directed. |
| 39 | Supply and fixing MCB, SPN, 240 volts, C Curve, 32 Amps 10 KA complete all as specified and as directed. |
| 40 | Supply and fixing MCB, SP, 240 volts, C Curve, 10-32 Amps 10 KA complete all as specified and as directed. |
| 41 | M&L for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in wall/floor PVC medium grade conduit not less than 20 mm as per IS with all fittings such as bends, tee, junction boxes,etc of suitable sizeincluding 1.5 Sqmm PVC (FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed. Note - Chase Cutting and making good of chasis in wall/roof/floor is included in the qtd rates. |
| 42 | Supply and fixing switch socket combination outlet 5 pin 6 Amps 16 Amps 2 in 1 flush type complete all as specified and as directed. |
| 43 | M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathedFRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC Concealed conduit medium grade minimum 20 mm dia ISI marked and conduit accessories fixed on recesses of wall/ceiling/roof and chisselling on wall complete andmaking good the disturbed surfaces of wall / ceiling by cement mortar 1:4 including painting to existing surfaces etc with sunken type pressed steel/welded MS terminal boxes made out of 1.25 mm MS sheet for mounting of fittings like switch, socket and fan regulator with 3mm thick hylum laminated sheet cover including cutting chases pining in for concealed conduit wiring amd making good of disturbed surface complete for the following srl items :- |
| 44 | One light/fan/ Bell point controlled by one one way switch complete all as specified and as directed. |
| 45 | One 3 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed. |
| 46 | One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size complete all as specified and directed. |
| 47 | All as per item No. 40.00 above but wiring with 2.5 sqmm multistranded copper conductor unsheathed and 2.5sqmm copper conductor unsheathed cable as earth continuity conductor for 6 pin 6/16 Amps switch socket combinationon independent board complete all as specified and as directed. |
| 48 | Supply and fixing Modular switch one way 10 Amp, single pole, 240 Voltscomplete all as specified and as directed. |
| 49 | Supply and fixing Modular socketoutlet 2/3 pin plug, 6 Amps, multi socket240 Voltscomplete all as specified and as directed. |
| 50 | Supply and fixing Modular switchone way modular type, 16 Amp, 240 Voltscomplete all as specified and as directed. |
| 51 | Supply and fixing Modular socket 6A/16A, 5 in one modular typoe, 240 voltscomplete all as specified and as directed. |
| 52 | Supply and fixing ceiling rose surface bakelite two to three terminal65 x 50 mm three terminal 250/230 volts ISI markedcomplete all as specified and as directed. |
| 53 | M&L for Lamp holder, PVC/Polycarbonate type with back plate strainght or angular suitable for batten fitting complete all as specified and as directed. |
| 54 | Supply and fixing as in repair LED invertor lights fitting 1x18W/20W, 220V, AC decorative box type with CRCA body precotaed white & pre wired fordriver, holder connecting up with LED down rodthree core flexible copper conductor cable of suitable size from ceiling rose including 1x18/20 w LED tube lightcomplete allas specified and as directed. |
| 55 | Supply and fixing as in repair LED invertor luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 56 | M&L for sub main wiring using two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade (FRLS) ISI marked drawing in and including 20mm dia rigid non metalic PVC concealed conduit & accessories like bends, tee, etc fixed on recess of wall and ceiling and connecting to earth dolly and including 4 Sqmm earth wire, PVC insulated & unsheathed including taking down old submain wiring of any type, complete allas specified and as directed. NOTE: 2 runs of main wire, 1 run of earth wire, 1 run of concealed conduit with accessories shall be measured as one length. |
| 57 | Supply and fixing factory made board distribution in sheet steel enclosure double door glazed with 200 Amps ratedbus bar, SPN, 8 ways, 240 Volts suitable for housing MCBs.complete all as specified and as directed. |
| 58 | Supply and fixing MCB, SPN, 415 volts, B Curve, 40 Amps 10 KA complete all as specified and as directed. |
| 59 | Supply and fixing exhaust fan, heavy duty, metal body, complete with three blade and louvers shutter, voltage 230V, 50Hz, AC, single phase, copper winding 300mm sweep complete all as specified and as directed.The quoted rate deemed to be included cutting suitable hole and making good the surface after cutting the hole, painting plastering etc. complete all as specified and as directed. |
| 60 | Supply and fixing electric water heater (Geyser), storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.vertical type, digital temperature displayed with suitable size of fastener and including provision and connected up up of SS braided pipe with adoptor for inlet and outlet water connection, copper element corrosion resistant antisaling magnisium anode, having adjustable knob for temperature control and inner tank material of supirior glass line coating/coating with single weld line tank and outer body material, ABS with high pressure withstand capacity upto 8 bar pressure, multiple safety system for protection against dry heating, over heating and over pressure, IPX4 water proof technology for longer product life having heating element 2 KW and minimum 2 year warranty on product and minimum three year warranty of heating element and 5 year warranty of tank including fixing bolts, nuts grouted into the wall and necessary cement work, making good of disturbed surface of wall, including necessary electric and water connection and testing after installation complete all as specified and as directed. |
| 61 | Supply and installation, testing and commissioning of 1200mm sweep BEE 5 star rated ceiling fan complete with brushless direct current (BLDC) motor class of insulation B, power factor not less than 0.9, service value (CMM/W) minimum 6.85 air delivery not less than 230 cum/min, 350 RPM (tolerance as per IS 374-2019), THD less than 10% including remote and electronic regulator unit for speed control and all remaining accessories including safety pin, nuts, bolts, washer, temparturerise =75 degree C (maximum), insulation resistance more than 2 megha ohm suitable for 230V, 50Hz, single phase AC, complete all as specified and directed. |
| 62 | Supply and fixing LED security light fitting 35 Watt, new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP-66 roadway luminaire with high power LED source with acrylic cover complete all as specified and as directed. |
| 63 | Material and labour for 40mm bore light grade GI pipe fixed as bracket, on wall any type, not less than 1.5 m long and bent to shape as required complete with sutiable clamp made out of 25x4mm Flat iron dulyfixed 12mm dia nuts, bolts, washers etc fixed to pole complete with two coats of aluminium paint over a coat of red oxide complete all as specified and as directed |
| 64 | Material and Labour Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 mtrs deep below normal ground level ) with the top edges of plate not less than 1.5 mtrs below normal ground level connected to GI strip of 25X4 mmby means of GInuts, bolts check nuts and washers earth lead protected by 15mm dia GI pipe light grade and connected to main distribution board/earthing test pointall as shown in electrical plate No 3 of SSR part 1 and all as specified including testing on completion. Notes:-The unit rate also including for excavation, earth work in any type of strata, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix , type B1 cover reinforced with 8mm dia TMT bars @150mm C/C both ways ,GI funnel with GIwatering pipe 20mm dia med grade, wire mesh, protection pipe 15 mm dia GI pipe light grade for earth lead upto 7.50m long, charcoal & salt complete all as specified and as directed. |
| 65 | B/R ITEMS |
| 66 | Excavation over areas depth exc 1.5m and not exc 3m and getting out in soft/loose soil complete all as specified and directed. |
| 67 | M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and as directed. |
| 68 | M&L for rendering 10mm thick in cement mortar (1:4) on fair faces of brick masonry or concrete surfaces of walls for fixing tiles to wall complete all as specified. |
| 69 | Material and labour preparation of newly plastered surface of walls & applying two coats of cement base paint complete all as specified and as directed |
| 70 | M&L for mild steel sheet of 1mm thickness and 100mm dia eaves gutters, galvanised class 3, half round with rounded edges including fixing clamps etc complete all ass specified and as directed. |
| 71 | M&L for 100mm dia angles (internal or external) or nozzle pieces (Out lets) complete all ass specified and as directed. |
| 72 | Supply and fixing 110mm bore PVC (SWR) rainwater pipes, double socketed in any length with rubber ring joints fixed laid in trenches or in floor etc complete all as specified and as directed. |
| 73 | S&F 110 mm bore PVC (SWR)bends any radiuscomplete all as specified and directed. |
| 74 | S&F 110mm dia PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed. |
| 75 | S&F 110mm dia PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 76 | S&F mild steel framed work as in doors / gates / steel frames etc. of angle or other section with gusset plates, rails, braces, etc., complete of Fe 410-w (Gde E-250) quality-A, drilled for fixing of steel sheeting or other covering door etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening including necessary welding etc and fixing in position complete complete all as specified and as directed. |
| 77 | S&F Mild steel framed work in tubular trusses and tubular posts using ERW or induction butt welded tubes conforming to I.S 1161-1979 Grade St-240 including necessary welding, bolting, special shaped washer, clamps, cleats etc. with and including one shop coat of zinc chromate primer paint complete all as specified & as directed. |
| 78 | M&L preparing new steelsurfaces of any description, not otherwise describe over 10cm width or girth and applyingtwo coats of synthetic enamel paintcomplete all as specified and as directed. |
| 79 | M&L for Brick work with sub class \"B\" bricks straight or curved on plan exc 6.00 m mean radius built in CM 1:6 complete as specified and directed. |
| 80 | M&L for reinforced cement concrete (nominal mix) in (1:2:4) type B1 (using 20mm graded stone aggregate) as in foundations, including rafts, footings and mass concretecomplete all as specified and as directed. |
| 81 | M&L reinforced cement concrete (nominal mix) (1:2:4) type B1 using 20mm graded granite stone aggregate in columns, pillars, piers, posts, struts and the like complete,all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under relevant item of this schedule. |
| 82 | M&L for reinforced cement concrete (nominal mix)(1:2:4) type B1 using 20mm graded aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. Note:- Reinforcements formwork will be measured and paid seperately under appropiate item. |
| 83 | Use and waste of flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete complete all as specified and as directed. |
| 84 | M&L formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal for fair finished flat surfaces of concrete complete all as specified and as directed. |
| 85 | M&L formwork to rough finished surfaces of flat concrete, sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified. |
| 86 | Materials and labour for Brick work with sub class \"B\" bricks straight or curved on plan exc 6.00 m mean radius built in CM 1.:4 complete as specified and directed. |
| 87 | Material and Labour for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips,complete all as specified and directed. |
| 88 | M&L for mild steel TMT bars 5mm to 10mm dia as in stirrups, spacers and binders cut to length bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and bending with and including MS wire (annealed) not less than 0.9 mm dia, complete,all as specified and directed. |
| 89 | M&L for 15mm thick rendering with cement mortar (1:4)on fair faces of brick work in two layers (10mm& 5mm) seperately mixed with water proofing compound in top layer as per manufacturer\"s instructions and finishing the surface even and fair without using extra cement complete all as specified and as directed.Note:- WPC shall be measured and paid seperately under appropiate item. |
| 90 | M&L rendering 10mm thick plaster on other than fair faces of brick or concretesurfaces in CM (1:6) finished the surface even and smooth without using extra cementcomplete all as specified and directed . |
| 91 | Supply only Liquid water proofing compound complete all as specified and directed. |
| 92 | M&L preparation of new surfaces of wall and applying two coats of weather exterior acrylic emulsion paint over acoat of 1.5mm thick wall care putty including priming coat of exterior primer complete all as specified and directed. |
| 93 | M&L for preparation of new surfaces of walls and distempering two or more coats with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colourcomplete, as per manufacturer\"s specification over a coat of 1.5mm thick wall care putty including primer complete all as specified and directed. |
| 94 | Material and Labour for broken stone or boulders hard core of gauge n.exc. 63 mm, deposited, spread and leveled in layers n.exc 15 cm thick, watered and well rammed to a true surface complete all as specified and directed. |
| 95 | M&L for 75 mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base, finished the surface fair and even complete all as specified and as directed. |
| 96 | M&L for 75 mm thick PCC (1:3:6) type C2 using 40mm graded stone agg as in plinth protection, finished even and smooth w/o using extra cement complete all as specified and as directed. |
| 97 | Supplyand fixing Prepainted galvalume aluminium zinc coating GI based corrugated/semi corrugated steel sheet crimped type 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 98 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and as directed.. |
| 99 | Supply and fixing anodized aluminium snap grid frame work for false ceiling, size of grid 605mm x 605mm complete all as specified & as directed. |
| 100 | M & L for 4 mm thick, Non asbestos fibre cement building boards fixed in ceiling or laid/ inserted to timber/GI/Aluminium frame work with screws, etc complete as specified and as directed. |
| 101 | M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15mm thick for laying floor finishes withCM (1:6) complete all as specified. |
| 102 | M&L Coloured glazed ceramic tiles 300 x 450 x 7 mm/450 x 350 x 7mm thick in vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing with CM (1:3) complete all as specified and as directed. |
| 103 | M&L for 15 mm bore tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed |
| 104 | M&L for 20 mm bore tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed |
| 105 | S&F Mild steel framed work such as grills,gratings,etc.with ends of bars shouldered and/or riveted,or forged into spikes,framed guard bars, barred iron doors,ladders, framed balusters, walk ways,railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 106 | M&L for Preparation of new or previously untreated steel and steel based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified & as directed. |
| 107 | Supply and fixing 1000 liters rotational moulded polyethylene water storage tank, triple layered (cylindrical vertical with closed top cover) as per IS-12701-1996, hoisted and fixed in position including necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I complete all as specified and as directed. |
| 108 | S&F factory made Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed. |
| 109 | Material and Labour for 3 mm thick sheet glass ordinary qualityand glazing with oil putty/wooden beads in squares not exc. 0.5 Sqm in each pane complete all as specified and as directed. |
| 110 | S&F stainlesssteel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 111 | Supply and fixing200 mmlong Aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and as directed. |
| 112 | S&F 150 mm Extruded aluminium alloy handles, cast type, anodised complete all as specified and as directed. |
| 113 | S & F 100 mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 &ISI marked complete all as specified and directed. |
| 114 | S&F tubular towel rail, aluminium anodized, 20mm dia, ‘D’ type, 60cm long between flanges, fixed to PVC rawl plugs with chromium plated brass screws, complete all as specified. |
| 115 | Supply and fixing 600 x 450mm bevelled edge mirror of selcted quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified complete all as specified and as directed |
| 116 | S&F vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe)complete all as specified and as directed. |
| 117 | S&F 10 ltr capacity PVC valve less, symphonic action type,flushing cistern, low level, withinlet ball valve, float and brackets includingflush pipe and PVC connection pipe 15mm bore with PTMT nuts of length 450mm, complete all as per directed byEngr-in-charge. |
| 118 | S&F in repair Hand shower (health faucet) (ABS Body) with 8mm dia, 1.2 meter long flexible tube & wall hook all as specified and as directed Make-JAQUAR CAT No-ALD-573 or equivalent make as specified in particular specification |
| 119 | S&F in repair toilet paper holder all as specified and as directed Make-JAQUAR CAT No-AKP-35751P or equivalent make as specified in particular specification |
| 120 | Supply and Fixing vitrious china full stall type, white including 40mm dia waste coupling chromium plated (excluding flushing cistern, flush pipe and waste pipe) etccomplete all as specified and directed. |
| 121 | S&F urinal spreader of PTMT any colour for fixing with 15mm bore pipe (Minimum weight 60 gms) as per sample approved by the GE. |
| 122 | M&L for Vitreous china urinal partition white of size 310x700 mm with necessary fixing arrangement as per manufacturer instruction complete all as specified and as directed. |
| 123 | S&F 15 mm dia Bib cock fancy type with chromium plated screwed down,screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 124 | Supply and fixing cast Copper alloy, chromium plated, fancy type, 15 mm bore angular stop valve with wall flange,screwed down, high pressure with crutch handle, screwed both ends for iron pipe or for union complete all as specified and directed. |
| 125 | Supply and fixing soap dish chromium plated brass alloy, any type, fix to plugs with chromium plated brass screws complete all as specified. |
| 126 | S&F 15mm bore PVC connections, with PTMT nuts of length 450mm complete all as specified and as directed. |
| 127 | Supply and fixing factory made soild PVC double door frame of size 50mm x 95mm made out of 5mm plain colour PVC sheet but single side prelam PVC sheet used instead of plain colour PVC sheet reinforced with MS tube, supplying & fixing in opening as per specification and drawing complete all as specified and as directed. |
| 128 | Supply and fixing Factory made solid PVC moulded door shutter, 28 to 30 mm thick (style), with 2, 4 or 6 raised panel design with 2mm thick moulded prelaminated PVC sheet on the front face & 2mm thick plain colour PVC sheet on back face, supplying and fixing in frame at site as all as per specifications and drawings as applicable to item 08101 given in SSR Part – II complete all as specified and as directed. |
| 129 | S&F 150 mm long aluminum alloy handle, febricated type anodised complete all as specified and directed. |
| 130 | S&F 250 mm aluminium alloy sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy fixed complete all as specified and as directed. |
| 131 | S&F 25 mm dia mild steel decorative type curtain rod, PVC coated with brackets complete as per sample including necessary brass srewscomplete all as specified and directed. |
| 132 | S & F for Steel windows with side hung shutters including projecting type hinges with handle and steel peg stay complete with glazing bars, dovetailed or welded including one shop coat of Red Oxide Zinc chromate primer complete all as specified and directed.(Note :- Glassshall be measured and paid for separately). |
| 133 | S& F 75 mm dia PVC (SWR) floor trap plain with gratingincluding jointing with solvent cement complete all as specified and directed. |
| 134 | Supply and Fixing PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 135 | S&F 75mm bore PVC (SWR) Pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 136 | S&F 110mm bore PVC (SWR) Pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 137 | S & F 110mm bore PVC ( SWR) vent cowl complete all as specified and directed. |
| 138 | Supply and fixing 32 mm bore low density poly ethylene pipes (LDPE) of pressure rating 6 kg/ cm2 as in waste pipe laid in trenches complete all as specified and as directed. |
| 139 | M&L for 100 mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base, finished the surface fair and even complete all as specified and as directed. |
| 140 | M&L for prepolished chequered cement concrete, colouredtiles,textured finished of size 200mm x 200mm x 25mm thickset jointed in neat cement slurry and pointed with grey cement and pigment in floors to match with colour of tiles, including 15mm thick screed bed in CM (1:6) complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |