| 1 | Labour attending day to day complaints from 0800 hrs to 1800 hrs be deploying manpower for checking of electric items including carried out of minor defects and carrying out tightining of loose electric connection, nuts, bolts, screwes, washers,etc as required to make the item functional and to ensure continuous electric supply complete all specified and diredted. Note : (a) Replacement of electric fitting shall measure and paid for seperately under respective items.(b)Rate quoted deemed to be inlusive of T&P etc.(c)The safety and insurance of persons/helper engaged in execution shall be responsibility of contractor.(d)As the Nos of complaint shall be on required basis the financial effect to this is deemed to be included in the rate quoted.(e)Penalty Rs 100/- per complaint per day be charged if complaint not rectified wihin 24 hrs. |
| 2 | Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc all as directed. |
| 3 | Taking down carefully UNSV main switch and DB\"s including MCBs of any size make, type and capacity and depositing at site as directed. |
| 4 | M & L for concealed point wiring complete with multistranded copper conductor (FRLS)1.5 Sqmm size PVC insulated unsheathed cable 1100 volt grade, conforming IS 694 & color code in conduit system of wiring, drawn in includingPVC conduit not less than 20 mm dia concealed duly fixed with U-Clips, including cutting chases, finising of slote by means of cement mortormakinggood to the existing surface of the wall & touching with the existing colour of wall with three coats and making good disturbed surface complete, sunk in pressed steel terminal boxes of required size not less than 1.2 mm thick factory made and factory painted with top cover 3 mm thick plastic laminated sheet fixed with brass screw and washer with all accessories including single core multistranded copper conductor 1.5 sqmm size solid PVC insulated unsheathed cable (FRLS) as earth wire to common earth and connected to earth dolly drawn in same conduit complete all as specified. |
| 5 | One light point controlled by one one/way switch. |
| 6 | One Fan point controlled by one one/way switch. |
| 7 | One 3 pin 5 Amps socket outlet on same board with other switch. |
| 8 | One 3 pin 5 Amps socket outlet on independent board. |
| 9 | One light point controlled by two way switches |
| 10 | One bell point controlled by one way switches |
| 11 | All as per item No. 4 above but using 2.5 Sqmm PVC insulated, unsheathed cable for one 3 pin socket outlet 15 Amps on independent board |
| 12 | M & L for point wiring complete with multistranded copper conductor 1.5 Sqmm size PVC insulated unsheathed cable 1100 volt grade, conforming IS 694 & color code includingPVC casing caping.the existing colour of wall with three coats and making good disturbed surface complete, sunk in pressed steel terminal boxes of required size not less than 1.2 mm thick factory made and factory painted with top cover 3 mm thick plastic laminated sheet fixed with brass screw and washer with all accessories including single core multistranded copper conductor 1.5 sqmm size solid PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit complete all as specified. |
| 13 | One light point controlled by one one/way switch. |
| 14 | One Fan point controlled by one one/way switch. |
| 15 | One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size. |
| 16 | All as per item No. 6 above but using 4 Sqmm PVC insulated, unsheathed cable for one 3 pin socket outlet 15 Amps on independent board |
| 17 | M & L forsub main wiring using two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 4 Sqmm earth wire, PVC insulated & unsheathed all as directed. Note : (i) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length |
| 18 | M & L forsub main wiring using two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 2.5 Sqmm earth wire, PVC insulated & unsheathed all as directed.Note : (i) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length |
| 19 | S&F switch piano flush type single pole one way 5 Amp 240 Volts. |
| 20 | S&F switch piano flush type single pole two way 5 Amp 240 Volts. |
| 21 | S&F switch socket combination 2 in 1, 3 pin, 5 Amps flush type 240 Volt. |
| 22 | S&F switch socket combination3 pin 5 and 15 Amp 2 in one flush with inbuilt indicating lamp. |
| 23 | S & F Bell switch including Bell ding dong type, one way, 240 volts, AC, ISI marked. |
| 24 | S&F ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked. |
| 25 | S&F ceiling fan capacitor 2.5 MFD. |
| 26 | S&F Modular switch 1 way 6A, 1module. |
| 27 | S&F Modular Socket, 6A - 2/3 pin combined 2module, |
| 28 | S&F Modular Socket 6A/16A - 2/3 pin combined 2 module, |
| 29 | S&F Modular Bell push 6A 1 module |
| 30 | S&F Modular Fan step regulator, 120W - 2 module |
| 31 | S&F Modular White cover plate with frame,1 module |
| 32 | S&F Modular White cover plate with frame,2 module |
| 33 | S&F Modular White cover plate with frame,4 module |
| 34 | S&F Modular White cover plate with frame, 6 module |
| 35 | S&F Modular White cover plate with frame,8 module |
| 36 | S&F Modular Metal flush box 1/2 module |
| 37 | S&F Modular Metal flush box 4 module |
| 38 | S&F Modular Metal flush box 6 module |
| 39 | S/F in repair TPN DBs Vertical type 4 way with provision for FP as incomer and SP as outgoing all as directed. |
| 40 | S/F in repair sheet metal enclosure for single pole and neutral 08 way 240 voilts, 100 Amp rated bus bar. |
| 41 | S & F MCB SPN 32 Amps 10 KA rupturing capacity. |
| 42 | S&F MCB SP 6 to 32 Amps 240V, 10 KA \"B\" curve Complete with connection testing and commissioning. |
| 43 | M & L for single core 1 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked |
| 44 | M & L for single core 1.5 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked |
| 45 | M & L for single core 2.5 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked |
| 46 | M & L for single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked |
| 47 | M & L for single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked |
| 48 | M & L for PVC conduit 20 mm dia |
| 49 | M & L for PVC conduit 25 mm dia |
| 50 | M & L for PVC Cassing & capping of size 20x12mm |
| 51 | M & L for PVC cassing & capping of size 25x16mm |
| 52 | S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd. |
| 53 | Taking down old existing fitting any type andSupply & Fix in replacement of 35 Watt LED security Light fitting New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection nominal voltage 240 volts, mains current 0.400 luminous efficiency >II3 lux/watts, potted electric LED dimmer (5MPS based constant current supply) with loner THD , CCT 5700 and impact resistance of IK07 with 10KV Built-in Surge Protection Device other safety tests as per IS 15885 Part-2/sec-13 Including bracket with clamp for fixing street light fitting made out of GI pipe of suitable size light grade including bending. |
| 54 | Taking down old existing fitting any type andS&F of 4\" 20W LEDTube With Batten with system lumen output of 1800 lumens. System Efficacy should be > 115lm/ W. The Luminaire Should have Cool Daylight Color temp of 6500K & CRI>80.Life 40K burning hrs with 70% lumen maintenace. PF>0.95 Surge Protecton of 3KV.All the Photometrical & Electrical parametrs must be supported by LM79-08 test report from NABL Accridiated LAB OR UL, R9 Value > 0. Lamp starting time is not more than 1 Sec. The LED tube light conforms to applicable IS. |
| 55 | Taking down old existing fitting any type andS&F of 2\" 10W LEDTube With Batten with system lumen output of 1800 lumens. System Efficacy should be > 115lm/ W. The Luminaire Should have Cool Daylight Color temp of 6500K & CRI>80.Life 40K burning hrs with 70% lumen maintenace. PF>0.95 Surge Protecton of 3KV.All the Photometrical & Electrical parametrs must be supported by LM79-08 test report from NABL Accridiated LAB OR UL, R9 Value > 0. Lamp starting time is not more than 1 Sec. The LED tube light conforms to applicable IS. |
| 56 | Taking down old existing fitting any type andSupply and fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 57 | Taking down old existing fitting any type andSupply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, IP-20 with and system lumen output 120 lm/W,220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |