| 1 | Sppply & LayingXLPE insulated, screened,PVCbedded, galvanised steel strip of wirearmoured electric power cable (heavy duty) with aluminium conductor 11000 volts grade cross section area 95 Sqmm 3 Coreas ordered including provision of necessary lugs and glands&makingnecessary connection complete all as specified and as directed |
| 2 | Excavation in trenchesnot exceeding 1.5mwidth and not exceeding 1.5 mdepth in hard / dense soil and getting out complete all as specified & directed. |
| 3 | Excavation in trenches in hard/dense soil not exc 1.5 m wide and depth exceeding 1.5m but not exc 3metc complete all as specified and as directed. |
| 4 | Material and labour for Plaincement concreate (1:4:8)type D2using40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed. |
| 5 | Material and labour for Cement concrete(1:2:4) type B1 using 20mm graded stone aggregate as incoping of pole rounded or chamfered on edges including necessary form work complete all as specified and as directed. |
| 6 | Supply and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolt, nuts and screwstype 410 SP-55, 11 meter longall as specified and direced, |
| 7 | Material and labour for Mild steel cross arm bracing, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicatedincluding applyingone coat of red oxide primer and two coat of synthetic enamel paint all as specified and direced. |
| 8 | Returning filling in trenchesincluding spreading, leveling,watering and well ramming in layers not exceeding 25 cm thick in soil all as specified and direced, |
| 9 | Removingof surplus excavated soilto a distance exc 500m but not exc 1000m anddepositing where directed all as specified and direced, |
| 10 | Supply & fillingsand in trenches for sand cushionof cables all as per para 19.75 of SSR Part-Iall as specified and as directed. |
| 11 | Supplying and laying un-reinforced precast concrete cable cover, class HV, Type-1, flat, size 300mm x 180mm x 40mm, ISI marked, laid flat across the cable length all as per specification and directed. |
| 12 | S & F in repairG I tubing light grade 80 mm dia bore including fittings like bend, socket etcfor protection of cableall as specified & directed. |
| 13 | Supply and fix cable jointing kit for 11KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminiumconductor cable of size 95 sq mmand testing complete all as specified & directed. |
| 14 | Supply and fix cable jointing kit for 11 KV grade cable for out door terminationheat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 Sqmm and testing after jointing all as directed. |
| 15 | M & L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique usingnecessary machine including driving HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressurecomplete all as specified & directed. |
| 16 | Earthing complete with galvanised steel earth plate electrole 60cmx60cm x 6.00mm thickburied directly in ground (earth pit depth not less than 2.25m deep below the ground level) with top edge of earth plate at a depth not less than 1.5m below ground level connected to GI Strip 32 mm x 6 mm diaby means ofof nuts, bolts and washer and check nuts of GI or steel connected to main DB/Panel including necessary earth work and excavation including PCC chamber 1:3:6type C1and RCC cover all as specified and or shown in electrical plate No 5 of SSR-I. |
| 17 | Supply and fix cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 sq mmand testing after jointing all as directed. |
| 18 | Dismantlingand taking up the existing HTUG cable of any descripiton & sizeall as directed |
| 19 | supply and fix in repair out door type triple pole switch (gang operated) each pole consisting of galvanised steel base HT insulators as per BSS/ISS , non ferrous knife and spring loaded contactmechanically operatedHorizontal/vertical type mounted etc., current rating upto 400 amps complete all as specified & directed. |
| 20 | S & F in repairs of lighting arrestor expulsion type complete with all fittings tansmission class discharge capacity 65 Kilo Amps suitable for 11000Volts grade completeall as directed at site. |
| 21 | S & F inrepairs of explusion fuse unit 11 KV drop out up to 100 Amps all as specified and directed at site. |
| 22 | Supply and fixingHT Cable route indicator marking PCC Block in PCC (1:3:6) type C1 using20mm grade stone aggregate of size0.3 x0.3 x0.6 Mtr ,and marking cable size on the top of the block and laying 40Mtr intervals all as specified and directed. |
| 23 | Dismantling unserviceableGOD with all fittings all as specified and directed. |
| 24 | Dismantling unserviceableLightning arrester with all fittingsall as specified and directed. |