| 1 | S/I/T/C of IP 66 double door cubical panel board along with canopy fabricated 14 SWG CRCA sheet of approx size 1.5 mtr X 1.5 mtr X 0.40mtr deep with provision of vertical adopter box on both sides & cubical boxes for fixing MCCB of various rating the vertical bus bar of 4 strip AI600 mm long 250 Ampinterconneclions with copper conductor cable with suitable size of thimbles lugs etc& powder coated as required I/c P/f following mounting & placing the panel on a stand 45 cm above the ground fabricated with channel iron (100 X 40 mm)/angIe iron (50x 50x 5mm) i/c sheet covering with 16 SWG sheet etcas required along with uninstallation and reinstallation of cables and dismantling and removal of the old panel from the site. The panel should include 1) 01 nos of 200Amp,36kA FPMCCB for incoming cable.2) 05 nos of 63 Amp,10 kA FPMCCB for outgoing cables.3 01 nos of 100 Amp, 26 KA FPMCB for outgoing cables.4) 02 nos of 32Amp DPMCB for outgoing cables.5) It should be supplied with voltmeter ammeter and necessary switches |
| 2 | Supply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required. 4 x 35 sq mm |
| 3 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. ,Including Laying complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)(DSR 2025-Item no. 15.16.1) |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. upto 35 sq. mm (DSR 2025 -Item no.10.5.1) |
| 5 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 35sq. mm (32mm) (DSR 2025 -Item no.11.1.34) |
| 6 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and 85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C- 100 W DSR 2025- Item no. 8.16.3 |
| 7 | Supply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required. 2 x 10 sq mm. |
| 8 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)(DSR 2022 -Item no.10.7.1) |
| 9 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 x 10 (19 mm) (DSR 2022 -Item no. 11.1.2) |
| 10 | 45 Watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver asper the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz,Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle asper IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report,\ CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and\ Fixture shall be of relevant BIS standard completein all respect i/c external connections with 1.5sq.mm FRLS/HFFR, PVC insulated copperconductor single core cable and earthing etc. asrequired with Minimum 5 year OEM warranty.System lumen efficacy ≥105 <120 lm/Watt output.LM79 & LM80 Test report and all testingrequired for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be asapproved by Engineer-in-Charge as perrequirement. (Thermal management: heat sink ofaluminium housing such that LED junction temperature shall not rise above 90°C).(DSR 2025 8.12.11) |
| 11 | Supplying and fixing 32 mm dia x 2 meters long G.I. (medium class) bracket for mounting of fluoroscent /HPMV/HPSV street light fitting on pole including bending the pipe to required shape , 2 nos40 mmx 3 mm flat iron clamps with nuts bolts and washer painting the flat iron with primer and finish paint etc as required (DSR 2025 13.34) |
| 12 | Less Credit for Old Dismantled Panel including transportation from site. |