| 1 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm (32mm) |
| 2 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 50 sq. mm (35mm) |
| 3 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 70 sq. mm (38mm) |
| 4 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 120 sq. mm (45mm) |
| 5 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 185 sq. mm (57mm) |
| 6 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 Amp, 16 KA, TPMCCB |
| 7 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 Amp, 16 KA, TPMCCB |
| 8 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 250 Amp, 36KA, FPMCCB |
| 9 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required a) Single pole |
| 10 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required a) Double pole |
| 11 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 12 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 13 | Providing and laying earth connection from earth electrode with 6 SWG gia G.I. wire in 15 mm dia G I Pipe from earth eletrode including connection with G.I. thimble excavation and filling as required |
| 14 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 15 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm |
| 16 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 50 sq. mm |
| 17 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 120 sq. mm |
| 18 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 185 sq. mm |
| 19 | SITC of various sizes water protected outdoor (Water proof)huttype compartmentalized type double door cubical panelboth side opening havingdepth up to 600 mmsuitable for 415 Volt, 3 phases, 50 Hz made out of 2mm thick CRCA sheet with required hardware duly painted with powder coated .Panel having separate detachable gland plate, end terminaion as per cable of size,angle iron base frame made out of 50mmx50mmx5mm angle iron of suitable size of the feeder pillar (minimum height 60cm), hinged door, both side opening with locking arrangement, earth bar/stud, led pilot light for phase indicator (R,Y,B) on top, 400A/415V 4 strip aluminum bus bar duly PVC sleeved, connection inter–connection with 25% extra current carrying capacity busbars to MCCBs spreader links and with solid copper conductor cable 10 sqmm/ solid aluminium rodfor connection toMCBs and heavy duty connectors of required current carrying capacity to be fixed back side including incoming/Outgoing cables connection for three and single phaseMCBs where as required, testing on loadand marking of location for incoming and out going distribution i/c grouting the legs in existing floor with 1:3:6 cement concrete foundation and dsimantling the existing panel, incoming/outgoing cable connections etc complete as required i/c dismentling the existing feeder pillar and UG cable. (Panel should beas per design &drawing approved by Engg in charge).LED light min 5 watt with on/off switch to be provided in the panel. |
| 20 | Providing And Fixing Of40 Amp MCCB three pole Breaking Capacity10 ka with spreader for ACThreephase, 415 vIcs=100% Icu, EZC Fixed thermal Magnetic trip unit (TMD) as per details specification in the LT panel and making inter connections with busbar as per the detail specifications mentioned inabove new panel item etc as required |
| 21 | Providing And Fixing Of63 Amp MCCB three pole Breaking Capacity10 ka with spreader links for ACThreephase, 415 vIcs=100% Icu, EZC Fixed thermal Magnetic trip unit (TMD) as per details specificationin the LT panel and making inter connections with busbar as per the detail specifications mentioned inabove new panel item etc as required. |
| 22 | Providing and laying of 3.5 C x 35 sqmmone number PVC insulated and PVC sheathed / armoured XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Make- KEI/Havells/Polycab |
| 23 | Providing and laying of 3.5 x 35 sqmmone number PVC insulated and PVC sheathed / armoured XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Make- KEI/Havells/Polycab |
| 24 | Providing and laying of 3.5 C x 35 sqmmone number PVC insulated and PVC sheathed / armoured XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct/open laying as required. Make- KEI/Havells/Polycab |
| 25 | Fabrication, Supplying, Installation, Testing and commissioning of outdoor type totally enclosed weather proof cable junction box of suitable size (minimum size 600mm x 600mm x 450mm) to accommodate following switchgears and accessories, fabricated from 14 SWG/2 mm thick CRCA sheet suitable for 415/500 volts, 50 Hz A.C. supply with gland plate, hinged front openable double leaf doors and locking arrangement, suitable size 4 strip Al. busbar of rating 400 Amp. Including providing and fixing followingswitchgears and accessories, treated with 7 tank process, powderpainted with approved shade, including connection / interconnections with FRLS PVC insulated copper conductor single core cable of suitable sizeetc. complete as required grouting the legs in existing floor with 1:3:6 cement concrete foundation and dsimantling the existing panel, incoming/outgoing cable connections etc complete as required i/c dismentling the existing feeder pillar and UG cable. (Panel should beas per design &drawing approved by Engg in charge). |