| 1 | Excavation in trenches, not exceeding1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cables/pipes etc. and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Returning filling including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft soil complete all as specified and directed. |
| 3 | Removing excavated surplus soil not exceeding 50 Mtr and depositing where directed ata level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 4 | M&L for sand cushioning with dry local sand for cable protecting under ground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenches including punning the sand upto 18 cm thick and consolidated complete all as specified and directed. |
| 5 | M&L for sub class ‘B’ common burnt, bricks old size, designated \"75\", laid dry, flat with length of bricks laid across the length ofcable to give mechanical protection to under ground cable complete all as specified and directed. |
| 6 | S&F for GI pipe 40 mm bore \"light grade\" ISI marked including fittings such as bends, tees, sockets etc fixed on wall/pole or laid in trenches under road crossing including taking down existing pipe complete all as specified and directed. |
| 7 | S&F for GI pipe 50 mm bore \"light grade\" ISI marked including fittings such as bends, tees, sockets etc fixed on wall/pole or laid in trenches under road crossing including taking down existing pipe complete all as specified and directed. |
| 8 | S&F for 80 mm dia GI pipe \"light grade\" ISI marked including fittings such as bends, tees, sockets etc fixed on wall/pole or laid in trenches under road crossing/hardstandingcomplete all as specified and directed. |
| 9 | Supplying ,laying, commissioning, jointing& testing 10 Sqmm , 4 core XLPE cable insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cablecomplete all as specified & directed. |
| 10 | All as per item No. 9 above but Cable 3.5 core 35 Sqmm. |
| 11 | All as per item No. 9 above but Cable 3.5 core 25 Sqmm |
| 12 | All as per item No. 9 above but Cable 3.5 core 50 Sqmm |
| 13 | All as per item No. 9 above but Cable3.5 core 95 Sqmm |
| 14 | All as per item No. 9 above but Cable 3.5 core 120 Sqmm |
| 15 | All as per item No. 9 above but Cable 3.5 core 240 Sqmm |
| 16 | Boring holes for Insertion of 80/50/40 mm dia GI pipe under PCC Road/ Taxi track/ hard standing not more than 12mm deep complete all as specified and directed. Note: - (i) Cost of equipments tools & plants, material required for boring shall be deemed to be included in the rates quoted above.(ii) GI Pipe shall be measured and paid separately. |
| 17 | Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m complete all as specified and directed. |
| 18 | Dismantling insulators any type, any size complete all as specified and directed. |
| 19 | Dismantling / disconnecting existing unserviceable ACSR conductoron overhead lines on LT/HT poles, of any size complete all as specified and directed. |
| 20 | Dismantling/disconnecting existing unserviceable earth wireon overhead lines on LT/HT poles, of any size complete all as specified and directed. |
| 21 | Taking out old/unsv/rusted including S&Fof steel tubular pole 410-SP 31(9.0m long pole) complete with cast iron base plate, pole cap, mild steel bolt, nuts and screws complete including dismantling of exsiting pole alongwith PCC foundation of pole all as specified including consisting of following works:- (a) Excavation in trenches not exceeding 1.5 mtr wide & 1.57 mtr deep for pole foundation & getting out in soft/loose soil, returning filling in the excavated of soil after fixing the pole in foundation ramming earth around in layer not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 mtrs complete all as specified and directed.(b) M&L for PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregate) in foundation 900mmx600mm cross section and planting depth 1.5 mtr for concrete encasing the pole upto GL complete all as specified and directed. |
| 22 | (c) M&L for providing PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) for plinth block/collar above GL 500mm high and 450mm dia complete all as specified and directed.(d) M&L for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminium paint over a coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto the height of 1.5mm above plinth block.(e) M&L for writing letter or figures (Block Roman, Italic as Indian) with thick synthetic enamel paint of apprised shade not exceeding 5 cm height including numbering of pole complete all as specified and directed.Note : Manufacture\"s test certificate of the pole will be produced before execution work.MAKE:National tubing Co., Kanpur or BCW Kanpur or M/s Sohan Lal & Sons or United Engineers, Kanpur. |
| 23 | Supply, fixing ( in replacement ), connecting to electrical system & testing of LT panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, totally enclosed of suitable size and supported with 4 NosMS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gaket and sealed mounted on PCC blocks double door type with locking arragnedment with handle at front and openable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- (a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of suitable rating ,(RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set.(b) Phase indication lamp, LED type(set of 3) -1 Set.(c) Digital multifunctional panel meterwith CTs etc.Make: L&T/Seimens/Schnieder. |
| 24 | (d) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sandetc complete.(e)ACB 4 Pole 630 Amp 415 volt manual drawout typewith 50 KA breaking capacity & spreader both side as Incomming control device :01 Nos. (L&T/ABB/C&S).(f)MCCB 4 Pole 400 Amp 415 voltwith microprocessor release 36 KA breaking capacity & spreader both side as outgoing cotrol device :01 Nos. (L&T/C&SABB).(g)MCCB 4 Pole 250 Amp 415 volt with microprocessor release 36 KA breaking capacity & spreader both side as outgoin cotrol device :02 Nos. (L&T/ABB/C&S).(h)MCCB 4 Pole 160 Amp 415 volt with adjustable thermal magnetic release 36 KA breaking capacity & spreader both side as outgoin cotrol device :02 Nos. (L&T/ABB/C&S). |
| 25 | Supply, fixing ( in replacement ), connecting to electrical system & testing of LT panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, totally enclosed of suitable size and supported with 4 NosMS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gaket and sealed mounted on PCC blocks double door type with locking arragnedment with handle at front and openable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- (a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of suitable rating ,(RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. |
| 26 | (b) Phase indication lamp, LED type(set of 3) -1 Set.(c) Display multi functional panel meterwith CTs etc: L&T/Seimens. (d) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sandetc complete. (e)INCOMMING: MCCB 4 Pole 400 Amp 415 voltwith microprocessor release, 36 KA breaking capacity & spreader both side as Incomming cotrol device :01 Nos. (L&T/ABB/C&S)(f) OUTGOING: MCCB 4 Pole 250 Amp 415 volt with microprocessor release, 36 KA breaking capacity & spreader both side as outgoing cotrol device :03 Nos. (L&T/ABB/C&S). (g)MCCB 4 Pole 160 Amp 415 voltwith adjustable thermal magnetic release 36 KA breaking capacity & spreader both side as outgoin cotrol device :02 Nos. (L&T/ABB/C&S). (h)MCCB 4 Pole 125 Amp 415 volt with adjustable thermal magnetic release release, 16 KA breaking capacity & spreader both side as outgoin cotrol device :01 Nos. (L&T/ABB/C&S). |
| 27 | Supply, install,test and commissioning of LT out door type kiosk pedastal panelboard of sige 60 cm x60 cm x30cm for 3 phase 4 wire 415 volts 50 HZ system, made out of 3.15 mm thick CRCA sheet with powder coated mounted on PCC platform, hinges with locking door arrangement,suitable cable enteries holes at bottom,and consisting of the following:-(a) Aluminium bus bar of rating 200 Amps capacity 4 Nos(TPN) mounted on DMC/epoxy supporters with shrouded by PVC insulated and arrangements for incoming / outgoing connections. -01 set(b) MCCB 4 Pole 160 Amp 415 voltwith adjustable thermal magnetic release 16 KA breaking capacity & spreader both side as outgoin cotrol device :01 Nos. (L&T/ABB/C&S). |
| 28 | Supply, install,testof LT out door type kiosk pedastal panelboard of sige 60 cm x60 cm x30cm for 3 phase 4 wire 415 volts 50 HZ system, made out of 3.15 mm thick CRCA sheet with powder coated mounted on PCC platform, hinges with locking door arrangement,suitable cable enteries holes at bottom,and consisting of the following:-(a) Aluminium bus bar of rating 400 Amps capacity 4 Nos(TPN) mounted on DMC/epoxy supporters with shrouded by PVC insulated and arrangements for incoming / outgoing connections. -01 set(b) MCCB 4 Pole 160 Amp 415 volt with adjustable thermal magnetic release, 36 KA breaking capacity & spreader both side as outgoing cotrol device :01 Nos. (L&T/ABB/C&S). |
| 29 | Supply & fixing in repair of automatic street light switch using infrared sensor based on nature switch for automatic switching of street lights. Nature switch operation should be based on nature light lux level. Required illumination level for switching ON is <30 lux and for switching OFF >10 lux.The nature switch along with suitable power contactors , incoming and outgoing MCBs should be enclosed in a pole/ wall mountable enclosure make of rust proof , electric shock proof and FR grade SMC junction box confirming to IP 65/66 suitable for three phase load of 5 kw with contactors (single phase 3Nos), incoming & Outgoing MCB SP (6 Nos),rating of 20-25 Amp & circuit wiring of min 10 sqmm complete all as specified and directed.Make -Swadeep Cat No. swadeep -02EC 5kw3P or equivalent in siemens /Indoasian |
| 30 | Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum heat resistant housing with driver,bracket with impact and corrosion resistant rectifierwith IP 65/66 protection complete all as specified. |
| 31 | Supply and fixing LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant rectifier and with inbuilt SPD and potted driver complete all as specified and directedMake : Syska Cat Part No. SSK-FLN-70W or equivalent in Philips Bajaj/Cropmpton/Havells. |
| 32 | M&L for errect, test and commissioning of High Mast pole systemconsisting of two section suitable for 55m/s wind speed alongwith head frame, made out of hot dip galvanised steel structure 15 Mtrs long, steel wire rope6mm dia 97/19 guage, double drum winch, luminiaries carriage suitable for 08 LED flood light in symmetrical arrangement and other accesories manufactured in factory with raising lowering system comprising double drum winch, trailing cable, connector, integral power tool motor, manual handle, junction box, lightining finial, (Wiring material from JB to individual luminiare & MCB in base compartment are not included and are a part of installation), with supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template and outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminiaries, power tool control with 2 No 9A contactors and raise lower push button, Incoming 25 sq. mm and out going 2.5sq. mm terminals. 16M High mast of BAJAJ Make or equivalent in Crompton, Philips, Havells.Note : Foundation bolts manufactured from special steel along with nuts, washeres, anchor plates and templates complete as recommeded by manufacturer or all as dircted by Engri-in-Charge.(i) The cost ofAviation light, feeder piller box,copper cable 5 core,2.5 Sqmmfrom feeder piller box to 250 Watt LED light deemed to be included in the quoted rate.(ii) The cost for RCC foundation shall be born by the contractor and design should be as per manufacturer recommendations & no extra amount will be paid to the contractor on this account.(iii) Design/drawing for foundation is as per manufactrer approval.(iv) The excavation of soil for RCC work for the foundation deemed to be included in the quoted rate(v) LED Flood light 200W shall be measured and paid separately. |
| 33 | Supply & fix in repairs cable looping box shock & rust proof of external dimension 230mm x 170mm x 105 mmincluding provision of 4 way heavy duty PVC insulated connector of suitable sizeall as directed by Engineer-in-Charge. MAKE: Sintex cat No. GSJB-2014 or equivalent inLegrand/Havells/Hensel. |
| 34 | S&F in repair1.5 Sq mm 3 core FR PVC insulated stranded copper conductor wire for 1100 V gradecomplete all as specified and directed. |
| 35 | Supply & Fixing GI pipe electrode earthing of high conductive, corrosion, CPRI tested manitenance free earthing pit toachive earth resistance value less than or equal to 3 Ohm & EN Voltage <2V, pipe in pipe technology based in which primary conductor(GI Pipe) having 40MM dia is inserted into secondary conductor having 80mmdia GI pipe. The primary conductor is inserted into secondory conductor are space between secondary and primary conductor of earthing electrode should be filled with crystalline compound. The length of this electrodes is min 3000mm (3 meters) and earth pit\"s bore hole should be of dia 200 to 250 mm and and min depth 3.50 meters and connecting with 25x 4 mm GI Strip. Around teh earth electrode earth pit borehole should be backfilled with minimum 50 Kg of ground enhencement compound ERIC contains mixture of Silica Sulphate, Alumina, Iron Oxide, Titanium Oxide, Calcium Oxide, Sodium Oxide, Zink Oxide etc) including RCC earthing pit of size 450x450x450mm (external) with PCC chamber cover complete all as directed by Engineer-in-Charge. Make Remedies/ MRS agency. Model G-80 (Note: if earth result not found less than 3 Ohm at site, the contractor will redo the earthing to achieve the desired result and no extra payment shall be made to the contractor) complete all as specified and directed. |