| 1 | Supply, laying and testing, in replacement XLPE cable, insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core, in trenches or passing through pipe or fixed to wall / pole and duct etc, including taking down of old unserviceable cable completeall as specified and as directed. |
| 2 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm, 2 core nominal cross section in service connections including taking down of old unserviceable cable completeall as specified and as directed. |
| 3 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm, 2 core nominal cross section in service connections including taking down of old unserviceable cable completeall as specified and as directed. |
| 4 | Excavation intrenches in soft/loose soil not exceeding 1.5 mtrdeep and not exceeding 1.5 mtrwide for laying of cables, pipes, RCC poles / stays and struts etc and getting out including trimming sides and forming levelledbottom surface all as specified and directed. |
| 5 | Returning, filling in, including spreading, watering and well ramming in layers notexceeding 25 cm thick each, in soft /loose soil complete all as specified and directed. |
| 6 | Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 7 | M&L for DWC pipe of 75 mm dia for electrical ducting laid in trenches and jointed including necessary jointing material, tees/ union/ socket etc completeall as per manufacturer\"s instructions including taking out old pipe complete all as specified and directed. |
| 8 | M&L for repairs to existing outdoor LT panel, removing the unserviceable hinges from doors (1.6mm thick MS), grinding the welded portion, denting and levelling the door, welding suitable new hinges (Approx. 0.50 Kg) to doors including locking arrangement and one coat of synthetic enamel paint as that of existing colour complete all as specified and as directed. |
| 9 | Material and labour for replacement ofearthing completewith galvanizedearth plateelectrode in 60 cm x 60 cmx6 mm thick buried directly in ground verticallyat a depth not less than 2.25 meterbelowgroundlevel with top edgeof earth plateat depth not lessthan 1.5 mtrbelow ground level connecting to and including GI strip32 mm x 6 mmby means of GI bolts, nuts, check nuts and washerlight grade40 mm dia GI protectionpipeandconnected to equipment, GIpipe medium grade20 mmdia forwatering an includingfunnel wire mesh, RCCpitcoverand PCC 1;2:4type B-1 including Rocksalt, charcoal, excavationand earth workdisposalof surplussoil shown as plateNo 3 of SSR Part - I2009 completeall as specified and directed.Note:Theunitrate quoted shalldeemed to have included for GIprotection pipe, GIearth stripup to 7.5mtr, GI waterpipe, wiremesh , funnel , excavation, RCC pitcover complete. |
| 10 | M&L for lowering of High Mast lantern to carry out repairs for lights and cables, fittings,gear box servicing, greasing of motor etc. and raising the lantern to its original position after replacement of items such as LED Flood light, LED driver etc, completeall as specified and directed.Note: LED flood light, LED driver etc will be measured and paid seperately as supply only items. |
| 11 | Supply only LED driver suitable for flood light 180 watt to 250 watt , out door type of existing make and model as approved by accepting officer. |
| 12 | Supply only LED flood light 200 watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, impact and corrosion resistant complete with driver and lamp. |
| 13 | S&F in repairs AC power contactor of rating 32 Amps AC3, 3 Pole complete all as specified and as directed. |
| 14 | S&F in repair MCCB, 160 Amps, four pole, 36 KA, 415 volt adjustable type completeall as specified and directed. |
| 15 | S&F in repair MCCB, 100 Amps, four pole, 16 KA, 415 volt adjustable type completeall as specified and directed. |
| 16 | S&F in repair MCCB, 63 Amps, four pole, 16 KA, 415 volt adjustable type completeall as specified and directed. |
| 17 | S&F in repair MCCB, 40 Amps, four pole, 16 KA, 415 volt adjustable type completeall as specified and directed. |
| 18 | Supply and fixing in repairs LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, impact and corrosion resistant including thermal management in multiple optics with IP 66 protection, fixing on existing brackets complete all as specified and directed. |
| 19 | M&L for taking down street light fitting from steel/PCC pole, supply & fixing of new LED driver of exisiting make and model of rating 50 to 70 Watt by taking out unserviceable LED driver and refixing the street light at its original position complete all as specified and as directed. Note: Work shall be done after switching off power supply from main LT panel. |
| 20 | Supply & Fixin replacement LED CONE BOLLARD light IP 65, 8 watt , maximum illumination aspect in surrounding, PCC foundation 20x20x30 cm including demolition of old PCC foundation complete all asspecified and directed. |
| 21 | Supply & Fixin replacement LED new generation, IP 65 LED post-top lantern 15 watt, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Opal Cover for soothing uniform illumination complete all asspecified and directed. |
| 22 | Supply and fix in repairs, LED driver suitable for LED post-top lantern and bollard lights 15 watt of existing make and model as approved by accepting officer. |
| 23 | M&L for GI post for garden light made of GI pipe light grade 50 mm dia 1.5 mtr long 30cm in foundation and 1.2 mtr above ground duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, PCC foundation 30x20x20cm including dismantling old foundation and taking out old rusted GI post complete all asspecified and directed. |
| 24 | S&F astronomical digital timer switch 16 amp, LCD display, astronomical programmable by entering longitude and latitude, also adjustable up to plus/minus 2hrs turning on later and off earlier than sunset and sunrise, with battery backup,suitable for connection with three phase supply including taking down old unserviceable timer switch of any type complete all as specified and as directed. |
| 25 | S&F in replacement FRP based outdoor type Junction box pole Hinged (L) mounted with clamps and including MCB SP, 6 Amps complete all as specified and as directed. |
| 26 | M&L for preparation of old surfaces of steel swan neck tubular poles and making strip white and blue colour up to 1.5 mtr height from top of PCC foundation block with synthetic enamel paint and painting the complete pole with one coat of aluminium paint above 1.5 mtr heightincluding numbering of poles with synthetic enamel paint black colourin 80 mm high letters completeall as specified and directed. |
| 27 | M&Lfor preparation of old surface of PCC poles and applying two coats of synthetic enamel paint over a coat of red oxide primer with black & white or yellow colour strips 30cm each up to1.5 mtr height from top of PCC foundation block and numbering of poles with synthetic enamel paint white in 80 mm high lettersabove 150 mm the top strip completeall as specified and directed. |
| 28 | M&L for painting of GI pipe bracket and clamp any size on pole security lights applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified and as directed. |
| 29 | M&L forServicing of DG Set 10 kVA Make:- Greaves cotton Model:- GPWII-10 at ICGS Jakhau by carrying out \"B\" check including draining out the lubricating oil, replacement of the following spares and testing complete all as specified and directed:- Note: Parts to be replaced will be measured and paidseparately under supply only items. |
| 30 | Supply only ofLub oil filter. |
| 31 | Supply only of Fuel filter |
| 32 | Supply only air filter paper element type. |
| 33 | Supply only of Lubricant oil 15W/40 premium blue. |
| 34 | Supply only coolant fluid for radiator. |
| 35 | M&L forServicing of DG Set 30 kVA trolly mounted Make:-Kirloskar Engine No:- APL-02051605 at ICGS Jakhau by carrying out \"B\" check including draining out the lubricating oil, cleaning of air cleaner etc and replacement of following spares and testing complete all as specified and directed:- Note: Parts to be replaced will be measured and paidseparately under supply only items. |
| 36 | Supply only ofLub oil filter. |
| 37 | Supply only of Fuel filter |
| 38 | Supply only air filter paper element type |
| 39 | Supply only of Lubricant oil 15W/40 premium blue |
| 40 | Supply only coolant fluid for radiator |
| 41 | M&L forServicing of DG Set 62.5 kVA trolly mounted Make:-CG Engine No:- 1308041507936 at CGRA Naliya by carrying out \"B\" check including draining out the lubricating oil, and replacement of the following spares and testing complete all as specified and directed:- Note: Parts to be replaced will be measured and paidseparately under supply only items. |
| 42 | Supply only ofLub oil filter. |
| 43 | Supply only of Fuel filter |
| 44 | Supply only air filter paper element type |
| 45 | Supply only of Lubricant oil 15W/40 premium blue |
| 46 | Supply only coolant fluid for radiator |
| 47 | M&L forServicing of DG Set 82.5 kVA Make:-Kirloskar, Engine No.:- 411-3545/1120116 at CGRA Naliya by carrying out \"B\" check including draining out the lubricating oil, and replacement of the following spares and testing complete all as specified and directed:- Note: Parts to be replaced will be measured and paidseparately under supply only items. |
| 48 | Supply only ofLub oil filter. |
| 49 | Supply only of Fuel filter |
| 50 | Supply only air filter paper element type |
| 51 | Supply only of Lubricant oil 15W/40 premium blue |
| 52 | Supply only coolant fluid for radiator |
| 53 | M&L forServicing of DG Set 125/100 kVA Make:-Greaves cotton , Engine No.:- 1308041606393 at ICGS Jakhau by carrying out \"B\" check including draining out the lubricating oil, and replacement of the following spares and testing complete all as specified and directed:- Note: Parts to be replaced will be measured and paidseparately under supply only items. |
| 54 | Supply only ofLub oil filter. |
| 55 | Supply only of Fuel filter |
| 56 | Supply only air filter paper element type |
| 57 | Supply only of Lubricant oil 15W/40 premium blue |
| 58 | Supply only coolant fluid for radiator |
| 59 | M&L for servicing of self starter assembly of DG sets 24/12 volts of 125 /100 KVA Gen set located at ICGS Jakhau by disconnecting the self starter assembly from the engine and dismantling, cleaning all accessories, replacing worn-out parts like carbon brushes, bushes, contact plates, jumping levels etc and rewinding the field coil and varnishing all as directed by Engr-in-charge. |
| 60 | M&L for servicing of self starter assembly of DG sets 24/12 volts of 82.5/62.5 KVA Gen set located at CGRA Naliya by disconnecting the self starter assembly from the engine and dismantling, cleaning all accessories, replacing worn-out parts like carbon brushes, bushes, contact plates, jumping levels etc and rewinding the field coil and varnishing completeall as specified and directed. |
| 61 | M&L for cleaning and descaling of 62.5 to 125 KVA radiator assembly by using suitable chemical and blower fan, injecting water with high pressure in water tubings so as to remove all dirt in the fins, taking downthe copper bottom portion of tank for welding / brazing and refit the same after replacing the unserviceable anddamaged fins, tank cap, rubber bush and refix the same at the engine of DG sets complete all as per manufacturer\"s instructions and as directed. |
| 62 | M&L for replacement of battery 12 V, 150 AH and making all electical connections completeall as specified and directed. |
| 63 | M&L for replacement of battery 12 V, 80 AH and making all electical connections completeall as specified and directed. |
| 64 | Supply only aluminium ladder of 10 ft height as sepcified by Engineer- in-Charge. |
| 65 | Supply only Set of Rubber Hand gloves and Rain Shoes of sizes as specified by Engineer-in-charge. |
| 66 | Supply only PVC Tool Box of size 43.5Lx 24Wx19.5H (cms) including Tools set of Ring Spanner,as specified by Engineer-in-charge. |
| 67 | Labour only for maintenance servicing andoverhauling of diesel engine for DG set cap of 100 KVA to 125 KVA, including valve seat & valve cutting/ valve grinding, head facing, manifold cleaning replacement of the spares etc and reassembling & alignment of the generator & engine including trial testing all as specified and directed at site.Note : Cost of spares shall be measured & paid separately as supply only items. |
| 68 | Supply only spares for 100 KVA to 125 KVA DG set to be incorporated in repairs:(a) Valve pair |
| 69 | (b) Valve guide & seat |
| 70 | (c) Intermediate ring 1.1 to 1.5 |
| 71 | (d) Piston |
| 72 | ( e) Liner |
| 73 | (f) Connecting rod bearing & bolt |
| 74 | (g) Main bearing |
| 75 | (h) Fly wheel ring |
| 76 | (j) Engine packing Set |
| 77 | (k)Oil pump |
| 78 | (l) Connecting rod bush |
| 79 | Labour only for maintenance servicing andoverhauling of diesel engine for DG set cap of 10 KVA to 82KVA, including valve seat & valve cutting/ valve grinding, head facing, manifold cleaning replacement of the spares etc and reassembling & alignment of the generator & engine including trial testing all as specified and directed at site.Note: Cost of spares shall be measured and paid separately as supply only items. |
| 80 | Supply only spares for 10 KVA to 82 KVA DG set to be incorporated in repairs:(a) Valve pair |
| 81 | (b) Valve guide & seat |
| 82 | ( c) Intermediate ring 1.1 to 1.5 |
| 83 | (d) Piston |
| 84 | (e ) Liner |
| 85 | (f) Connecting rod bearing & bolt |
| 86 | (g) Main bearing |
| 87 | (h) Fly wheel ring |
| 88 | (j) Engine packing Set |
| 89 | (k) Oil pump |
| 90 | (l) Connecting rod bush |