| 1 | Taking down chowkats with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each including making good disturbed portions of wall with new or old bricks and lintel,cills, etc as per existing specifications complete all asspecifiedand directed. |
| 2 | Taking down chowkats with shutters (without taking off shutters from the frames) area exc 1.5 Sqm each and not exc. 4.00 Sqm including making good disturbed portions of wall with new or old bricks and lintel, cills, etc as per existing specifications complete all asspecifiedand directed. |
| 3 | S&F Powder coated aluminium sliding window frame with movable shutter ( sliding on minimum two PVC roller of best quality, for each shutter on threetracks with stainless steel mosquito proofing and glazing shutter with and including 5.50 mm thick glass & stainless steel wire mesh fixed with neoprene rubber gasket with aluminium beading, clips,frame made with aluminium section as appended below- (i) Window frame :68.4x38mm X 1.15 mm thick for three tracks.(ii) Top/bottom rail and style / rail of shutter : 15x37.5x1.15 mm thick and over. (iii) Aluminium beading - 0.7mm thick (iv) Stainless steel wire cloth 0.45mm nominal dia of wire and average width of aperature 1.40mm and fixed in aluminium window or alongwith F/Y section fixed with aluminium wire staples complete.(v)Aluminiumfittings suchaluminium suitable handle with auto interlock cap with suitable size.(vi) Making good of wall surfaces with silicon to match with existing surfaces complete all as directed. Notes: Rate quoted is inclusive for provn of above items in frame with shutter. |
| 4 | S&Fpowder coatedaluminium frame for doors, windows, ventilators and kitchen cupboards frame size 100x44mm and 1.2mm thick or approriate size as approved by GE with one or more rebates including joining cleat for fixing etc and add for powder coating (minimum thickness of powder coating 50 micron) complete all as specified. Weight of section should not less than 1.12 kg per RM. |
| 5 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS : 1868 with minium anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engr-in-Charge. |
| 6 | S&F sheet glass 5.5mm thickordinary quality and glazing with oil putty in square n exc 0.5 Sqm each pane complete all as specified & directed. |
| 7 | S&F galvanised Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanesed wire stapels complete all as specifed and directed. |
| 8 | Demolition of brick work or stone/boulder masonry built in cement mortar or cement limemortar including all quoins, aches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 9 | M&L brick work with sub class \"B\" bricks old size straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed. |
| 10 | M&L brick work with sub class \"B\" bricks old size straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. |
| 11 | Taking down cement plaster on brick or stone walls, ceiling etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 12 | M & L for Rendering 15mm thick (10mm+5mm) in two layer in cement plaster 1:4 on in two layer other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified anddirected(WPC measured and paid separately)Note:WPC to be used and measured only in top layer(5mm) of plastering. |
| 13 | M&L 10mm thick cement plaster on other than fair faces ofbrick surfaces or concrete surfaces (on internal surface) in CM 1:6without using extra cement including necessary scaffolding complete all as specified and directed. |
| 14 | M&L for applying3mm thick wall care putty on wall surfacesincl rubbing down the surfaces with sand paper after getting dried all as directed to obtain a smooth & even surface complete all as specified and directed. |
| 15 | M & L applying two coat of distemper oil emulsion distemper white or tinted on newly plastereddecorated or undecorated wall surface including preparation ofsurfaces by washing rubbing down and stopping of any surfaces of walls complete all as specified. |
| 16 | M & L applying two coat of distemper oil emulsion distemper white or tinted on old decorated or undecorated wall surface including preparation ofsurfaces by washing rubbing down and stopping of distempered and painted surfaces complete all as specified. |
| 17 | M & L applying two coat of cement based paint on new plastered surfaces ofwall, roof surface including preparation ofsurfaces by washing rubbing down and stopping of old wall surfaces complete all as specified and directed. |
| 18 | M & L applying two coat of cement based paint on old decorated or undecorated wall and parapets etc including preparation ofold surfaces incuding washing down/rubbing down previously surfaces complete all as specified and directed. |
| 19 | M&L Preparation of oldwooden surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specifed and directed. |
| 20 | Demolition of reinforced cement concreteof any description and in any position not otherwise specifically provided for complete all as specifed and directed. |
| 21 | M & L formwork to sides and soffits of lintels,lintel bend, beams etc for rough finished surfaces of concrete complete all as specified and directed. |
| 22 | M & L formwork to chullah hoods, chajjas, trough, flat surface etc and similar items including edges, for rough surfaces of concrete complete all as specified and directed. |
| 23 | M&L Formwork to edges of concrete finish flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm widecomplete all as specified. |
| 24 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specifed and directed. |
| 25 | S&F TMT bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders bent to shape required,including binding with mild steel wire (annealed) not less than .9mm dia complete all as specifed and directed. |
| 26 | M&L RCC 1:1.5:3 type B1 using 20 mm graded crushed aggregate as in slab, shelves and stair case etc complete all as specified and directed. |
| 27 | M&L RCC type B 1, 1:1.5:3 using 20mm graded crushed stone aggregate as in beams, cantilevers, lintels, chajjaetc complete all as specifed and directed. |
| 28 | Supply only Liquid water proofing compound complete all as specified and directed. |
| 29 | Demolition of cement concrete (unreinforced) as in roofs, floors, (other than ground floor) beam, stairs, chajja , landing, and similar suspended work upto the RCC complete all as specifed and directed. |
| 30 | M&L for 10 mm rendering in CM 1:4 including water proofing compound @2% of cement over roof surfaces finished even and smooth without using extra cement complete all as specifed and directed.Note: WPC to bemesured and paid for Separately. |
| 31 | M&L for Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces complete all as specifed and directed. |
| 32 | M&L forApplying evenly a tack coat of induatrial bitumen 85/25 grade @ 1.2 Kg/Sqm complete all as specifed and directed. |
| 33 | One layer of APP based polymeric membrane of approved manufacturer, 3mm thick, weight not less than 3.00 Kgs per Sqm , reinforced with non woven polyester fabric or weight not less than 150 gms per Sqm . Polymeric membrane shall be taken to a height 60 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing complete all as specified and directed.(Note (i) Laying of APP based polymeric membrane shall be done by torch on method or as per manufacturers instructions(ii) A Minimum overlap of 100 mmand 75 mm shouldbe made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufacturers instructions(iii) The make of polymeric membrane shall be IWL India Ltd chennai. Ltd or \"MOPLY FP\" of Texsa India Ltd). Note:- S&F of APP based polymeric membrane of approved manufacturer will belaid/fixedby authorised person of the same manufacturers units asper relevent IS. |
| 34 | M&L for Aluminium paint 2 coat on Surfaces of any description, over10cm in width or girth complete all as specifed and directed. |
| 35 | PCC 1:2:4 type B-0 using 12.50mm crushed stone aggregates as in roof padding finished even and smooth without using extra cement complete all as specifed and directed. |
| 36 | Disconnecting Existing Tanks, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and refixing in position ( cleaning, repairing, etc measured separately) exc. 250 Litre and n. exc. 500 Litre complete all as specifed and directed. |
| 37 | Disconnecting Existing Tanks, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and refixing in position ( cleaning, repairing, etc measured separately) exc. 500 litre and n. exc. 1000Litre complete all as specifed and directed. |
| 38 | S & F in repairs,20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. Minimum weight 20 mm - 210 gms complete all as specifed and directed. |
| 39 | S & F in repairs, PVC cover/lid for PVC over head water tank suitable for capacity of above 500 ltrs and upto1000 ltrs capacity complete all as specifed and directed. |
| 40 | S & F in repairsRotational moulded polyethlene water storage tanks three layered of 500 ltrs capacity ISI marked (cylindrical vertical with closed top) white in colour hoisted and fixed in position all as specified in SSR Part I including 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including dismantling of old broken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed. |
| 41 | All as per item No 40 here in before but 1000 litres complete all as specifed and directed. |
| 42 | M & L for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, et exc. 250 ltr and n. exc. 500 ltr complete all as specifed and directed. |
| 43 | M & L for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, et exc. 500 ltr and n. exc. 1000 ltr complete all as specifed and directed. |
| 44 | S&F of framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specifed and directed. |
| 45 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specifed and directed. |
| 46 | Taking up or down steel tubing and connections including cleaning for refixing or removal from site upto 25mm bore complete all as specifed and directed. |
| 47 | S & F 15mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs complete all as specifed and directed. |
| 48 | S & F 20mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs complete all as specifed and directed. |
| 49 | Dismantling cast-iron/PVC pipes including fittings taking out of trenches or walls as required dia of pipe upto 100mm complete all as specifed and directed. |
| 50 | S&F PVC (SWR) pipes Type A single socketed in any length with rubber ring joints fixed to walls for 110mm bore complete all as specifed and directed. |
| 51 | S&F PVC (SWR) pipes Type A single socketed in any length with rubber ring joints fixed to walls for 75mm bore complete all as specifed and directed. |
| 52 | S&F PVC (SWR) Bendsany radius for 110mm bore complete all as specifed and directed. |
| 53 | S&F PVC (SWR) Bendsany radius for 75mm bore with oval access door complete all as specifed and directed. |
| 54 | M&L for cement concrete tile in roof size of 25cmx25cmx20mm, machine pressed, set jointed and pointed in neat cement slurry with grey cement and no pigment , including well polished and girinding , etc complete all as specified and directed. |