| Sl. No. | Item Description |
| 1 | Taking down cement plaster in any descriptionon brick or stone wall etc incl racking outjoints. Hacking for key scrubbing down with water etc complete all as specified and directed. |
| 2 | M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair face of brick work or concrete surface on external surfaces in CM (1:4) & water proofing compound mixed with second layer @ 250 ml/Bag or as per manufacturer instructionfinished fair and even. complete all as specified and directed. ( Note -W.P.C. shall be measured and paid separately . ) |
| 3 | Supply only integral water proofing compound all as specified and as directed. |
| 4 | M&L for 15 mm thick rendering in CM (1:6) on other than fair face of brick or concrete surfaces on internal surfaces finishing even and smooth without using extra cement complete all as specified and directed. |
| 5 | M&L rendering 10 mm thick in CM 1:3 on ceilings finished even and smooth without using extra cement (up to ceiling height of 6 to 7m )incl necessary arrangements for execution of the work) all as specified and directed. |
| 6 | Demolitionof brick work or stone/boulder masonarybuilt in cement mortar incl all quoins arches pillars etc complete all as specified and directed. |
| 7 | M&L for brick work with flyash bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed. |
| 8 | M&L brick work with flyash bricks, (with Old Size Bricks),straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed. |
| 9 | Forming jambs etc openings etc including cutting toothing and properly bonding into old work also facing, jointing and pointing to match existing work built in cm 1:6 complete all as directed . |
| 10 | Making good under cill or over arches, lintels including all pinning in with cement mortar 1:4 complete all as directed . |
| 11 | Demolition of reinforced cement concrete of any description for Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended slabs complete all as specified and directed. |
| 12 | Formwork Use and waste to sides and soffits and suspended slabs n. exc. 200 mm thick and similar works fair finished surfaces of concrete complete all as specified and directed. |
| 13 | M&L For RCC 1:2:4 type B1 20 mm graded as in chajja supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed. |
| 14 | S & F mild steel TMT bar10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed. |
| 15 | M&L for complete removal of existing treatment of old wall surface and applying two coats of oil bound distemper over a coat of alkali resistant primer applied over 1 to 2mm thick water proof wall care putty complete all as directed by Engr-in-charge. |
| 16 | M&L for preparation of new wall surface and applying two coats of oil bound distemper over a coat of alkali resistant primer applied over 1 to 2mm thick water proof wall care putty complete all as directed by Engr-in-charge. |
| 17 | M&Lforapplying two coats of oil bound distemper to old decorated (distempered) surfaces of ceiling including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed by Engineer -in-Charge. |
| 18 | M&Lforapplying two coats of oil bound distemper to new plastered surfaces of ceiling including preparation of surface complete all as specified and directed by Engineer -in-Charge. |
| 19 | M & L applying two coats of synthetic enamel paint on new wooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and directed. |
| 20 | M & L applying one coats of synthetic enamel paint on old painted surface wooden surfaces of any description over 10 cm width or girth complete all as specified and directed. |
| 21 | M & L applying two coats of synthetic enamel paint on new steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of surfaces complete all as specified and directed. |
| 22 | M & L applying one coats of synthetic enamel paint on old steel surface of any description over 10 cm width or girth complete all as specified and directed. |
| 23 | M & L Preparation of old treated/ painted surfaces of walls and soffits of Chajja, roof slab etc, by cleaning brooming, rubbing and scrapping as required using broom, emery paper, putty blade/ scraper as applicable to make the surface free from loose paint, algae formation dust etc including necessary safety & protective measures such as safety belt, headgear etc including filling cracks upto 5mm with and including suitable elastomeric crackfill paste and applying two coat of weather proof exterior emulsion paint over alkali resistant primer over 1-1.5 mm thick wall care putty of approved make using airless spray technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for upto 4 storey building height complete all as specified and directed. |
| 24 | M & L Preparation of new surface of walls and soffits of Chajja, roof slab etc, by cleaning brooming, rubbing and scrapping as required using broom, emery paper, putty blade/ scraper as applicable to make the surface free from loose paint, algae formation dust etc including necessary safety & protective measures such as safety belt, headgear etc including filling cracks upto 2mm thick exterior wall putty ( in two layers) for smooth finish and finishing with two coat of weather proof exterior emulsion paint over alkali resistant primer over 1-1.5 mm thick wall care pitty of approved make using airless spray technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for upto 4 storey building height complete all as specified and directed. |
| 25 | Demolition of cement concrete (un-reinforced) not exc 15cm thick inground floor and paving (below or above ground level) completeall as specified and directed. |
| 26 | M & LPCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed. |
| 27 | M & LPCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed. |
| 28 | Dismantling Structuralsteel wok incl grills ,gates, stair case etc but excluding framed truss in any position complete all as specified and directed. |
| 29 | Fixing only old Joist, channel angle of beams etccutting with suitable size complete all as specified and directed. |
| 30 | S & F mild steel in framed work such as grills, gratings, etc. with ends of bars shouldered and /or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed by Engineer-in-Charge. |
| 31 | M&L mild steel rolled sections as in main and cross beams, angle, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors etc conforming to grade Fe-410- W (Gde- E- 250) quality- A made to required shape and size, welded at joints complete all as specified and directed |
| 32 | Dismantling of plain or corrugatedsheeting , any guage, thickness and including Naintital or similar pattern roof coverings complete all as specified and directed. |
| 33 | S & Fpre-paintedGalvalume aluminium zinc coating GI based corrugated steel 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 34 | S & F pre-paintedgalvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridges , valley gutter, Sun shed etcfixed with self tapping screws as specified. |
| 35 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 including necessary form work complete all as specified and directed. |
| 36 | Cutting holes in brick walls in cement mortar for inserting holdfast or pipes and making gooddismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required exc half brick but not exc one brick, etc complete all as specified and directed. |
| 37 | Dismantling of cast iron or AC drain pipe/ PVC pipe jointed in cement mortar of size 110mm bore as directed |
| 38 | S&F 100 mm dia Cast soil waste and vent pipes in any length with or without ears with cement joints laid in trenches or in floor complete all as specified and directed |
| 39 | S&F 100 mm dia Cast soil waste and vent pipes in any length with or without ears with cement joints fixed on wall complete all as specified and directed |
| 40 | S&F in repair 100mm CIbends any radius complete all as specified and directed |
| 41 | S&F in repair 100mm CI\"T\"any radius complete all as specified and directed |
| 42 | S&F 100 mm bore Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed. |
| 43 | S&F 100 mm bore Cast iron nhani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed. |
| 44 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) andrubbish off the premises complete all as specified and directed. |
| 45 | M&L non skid ceramic colourtiles of area of each tile exc .06 Sqm but n exc exc .11 Sqm and 6 to 7 mmthick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement completeincluding 15 mm thick screed bed cement mortar 1:6 completeall as specified and directed. all as specified and directed . |
| 46 | M&L Vitrified ceramicjoint free tilesarea of each tile exc0.18 Sqm but n exc exc 0 .36 Sqmand 7 to 8 mmthick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement completeincluding 15 mm thick screed bed cement mortar 1:6 completeall as specified and directed. all as specified and directed . |
| 47 | M&L Vitrified ceramicjoint free colour tilesfor Vertical surface of area of each tile exc0.18 Sqm but n exc exc 0 .36 Sqmand 7 to 8 mmthick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement completeincluding 10 mm thick screed bed cement mortar 1:3 completeall as specified and directed. all as specified and directed . |
| 48 | M&L Vitrified ceramicjoint free tilesarea of each tile exc0.42 Sqm but n exc exc 1.0 Sqmand 9-10 mmthick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement completeincluding 15 mm thick screed bed cement mortar 1:6 completeall as specified and directed. all as specified and directed . |
| 49 | M&L Vitrified ceramicjoint free colour tilesfor Vertical surface of area of each tile exc0.42 Sqm but n exc exc 1.0 Sqmand 9-10 mmthick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement completeincluding 10 mm thick screed bed cement mortar 1:3 completeall as specified and directed. all as specified and directed . |
| 50 | M & L glazed ceramic colour tiles size 600 mm x 300 mm x 6 to 7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cementincluding 10 mm thick plastering incement mortar 1:4 completeall as specified and directed. to match completeall as specified and directed. |
| 51 | Dismantling of wall andceiling board (fibre pulp, insulation, etc ) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed. |
| 52 | Supply and Fixing PVC solid wall lining consisting of 5 mm thick plain colourPVC sheet used inclusive of solvent cementand fixing at site on PVC frame as per manufacturer’s specification and instruction) directed by the Engineer-in-Charge. |
| 53 | Supply and Fixing PVC fillets of width 35 mm, made of 5 mm thick PVC sheet, for wall paneling inclusive of fixing as in grid / frame on wall at a distance .6m horizontal & vertical for wall lining/paneling as per specification of manufacturer and as directed by the Engineer-in-Charge. |
| 54 | S & F 10 to 12 mm thick gypsum board false ceiling including 0.55 mm thick GI perimeter channel, GI channel tray frame work having one flange of 20mm and another flange of 30mmwith web of 27mm, fixed to surrounding wall using nylon sleeves and screws @ 450mm centre to centre / GI intermediate channel of size 45mm x 0.90mm thick with two flange of 15mm each suspended from the soffit of roof slab/ truss @1220mm c/c with MS angle of suitable size fixed to soffit of ceiling with GI cleat and expansion fasteners with and including ceiling section ( not exc 1.2 metre length ) of 0.55 mm thickness having kurled web of 50 mm and flange of 25 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel @ 457 mm centre to centre with necessary nuts and bolts and gypsum board screwed to ceiling section with stainless steel screws @ 230mm c/c including applying two coats of plastic emulsion paint over a coat of primer to exposed surfaces complete all as specified and directed. |
| 55 | M&L False ceiling with \"E\" board \"Classic\", reinforced, designer series, board with HPSC of size 600 mm x 600 mm x 4 mm thick fixed on aluminium snap grid to support the boards/files with aluminium anodised main \"T\" section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and aluminium angle 25mm x 25mm x 1.40mm as on edges/sides, fixed to ceilingwith supporting hangar consisting of 6 mm dia mild steel rod, J bolts with necessary bolts and washers and anodised adjuster and applying two coats of oil bound distemper over a coat of alkali resistant primer on exposed surfaces completeall as specified and as directed.(NOTE: Quoted rate shall be deemed to be inclusive of the cost of ceiling board) |
| 56 | Demolition of cement concrete (un-reinforced) not exc 15cm thick inground floor and paving (below or above ground level) completeall as specified and directed. |
| 57 | M&L 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar places, laid in alternate bays, surface finished even and fair without using extra cement complete all as specified and directed. |
| 58 | M & L forheavy duty coloured ceramic floor tiles of size 300 x 300x 10 mm thick, suitable for high traffic external tiles, anti skid, scratch resistance and neutral to UV rays and acid alkali resistance as in floor including 15mm thick screed bed in cement mortar 1:4 complete all as specified anddirected.(MAKE : JOHNSON, Model : ENDURA or equivalent model in other makes listed in the tender) |
| 59 | M & L 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring, laid in alternate bays, surface finished even and smooth using without extra cement complete all as specified and directed. |
| 60 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, dry bedded completeall as specified and directed. |
| 61 | M & L RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in slab supported on wall, beam and columns in floor, roof landing,, balconies, conopies, deck slab and shelvesetc complete all as specified and directed. |
| 62 | M & L for 20 mm thick screed bed or bedding layer of mortar as in backing coat of stone on fair face of brick wall or concrete surface in cement mortar 1:4 completeall as specified and directed. |
| 63 | M & L 18 to 20 mm thick machine cut one side polished natural hard stone (Granite)any type in step, jambs, pillars, window cills, cooking plate fromand similar places etc like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 64 | Taking down chowkhats or frames not exc 1.5 sqm each (without taking off shutter from the frame) complete all as specified and directed. |
| 65 | Taking down chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutter from the frame) complete all as specified and directed. |
| 66 | S&F 2nd class hard woodplain solid straight chowkats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints all as specified and as directed by Engineer-in-charge. |
| 67 | Cutting holes in to brick wall for inserting bold fast & making good dismantled portion in cm (1:3) or PCC (1:2:4) type B1, exe half brick but not exe 1 brick complete all as specified and directed |
| 68 | S & F mild steel work holdfast, cleat etc. for door frame/ wooden batten etc. quality conforming to Fe-290 Gde-E-165complete all as specified and directed |
| 69 | S&F 35 mm thickness 2nd class hard wood factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated all as specified. |
| 70 | Supply & fixing 100 mm stainless steel butt hinges (medium weight) cold rolled complete all as specified and directed. |
| 71 | S & F aluminium handles 150 mm long cast type, anodised completeall as specified and directed. |
| 72 | S & F aluminium anodised barrel tower bolts 150 mm long of extruded section and fixed completeall as specified and directed. |
| 73 | S & F 300 mm aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sec or cast aluminium and fixed complete all as specified and directed. |
| 74 | Supplying and installing rectangular uPVC- Fixed windows made out of lead free green profiles having aworldwide presence with a GREENLINE mark with frame dimension of 58mm x 52mm x 33mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2mm . The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should be a certified member of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised local fabrication partner . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside and Outside ofDowcorning / GE or equivalent. Scaffolding if required will be charged at actuals. The profiles should be of aninternational brand having factories in multiple countries and having a warranty of 20 years. The profiles shouldconform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001 |
| 75 | Supplying and installing uPVC- Sliding windows/doors made out of lead free green profiles having a worldwide presence with a GREENLINE mark having three tracks and three sashes (shutters) and one fly screen sash with frame dimension of 137.5 mm x 49mm and sash dimension of 61mm x 47mm x 37 mm and fly screen sash dimension of 32mm x 58mm with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should be a certifiedmember of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. The profiles should be of an international brand having factories in multiple countries and having a warranty of 20 years. The profiles should conform to BSI Quality Management System ISO 9001Supplying and installing uPVC- Sliding indows/doors made out of lead free green profileshaving a worldwide presence with a GREENLINE mark having three tracks and three sashes (shutters) with frame dimension of 104mm x 49mm and sash dimension of 61mm x 47mm x 37mm each with middle sash fixed with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm. |
| 76 | The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should be a certified member of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner . The windows must be installed complete with all kinds of ironmongery in Ist quality (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside and Outside of Dowcorning / GE or equivalent.The profiles should be of an international brand having factories in multiple countries and having a warranty of 20 years. The profiles should conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 and also scaffolding if required for fixing is deemed to include in the rate quoted. Make Kommerling or equivalent in other makes. |
| 77 | Supplying and installing uPVC- 1sash casement doors made out of lead free green profileshaving a worldwide presence with a GREENLINE mark having sashes (shutters) with frame dimension of 104mm x 49mm and sash dimension of 61mm x 47mm x 37mm each with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should be a certified member of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside and Outside of Dowcorning / GE or equivalent. Scaffolding if required will be charged at actuals. The profiles should be of an international brand having factories in multiple countries and having a warranty of 20 years. The profiles should conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 and also scaffolding if required for fixing is deemed to include in the rate quoted of Make Kommerling or equivalent model in Fanesta & in other makes. |
| 78 | S&F 5.0 mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes all as specified and directed. |
| 79 | S&F 10.0 mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes all as specified and directed. |
| 80 | Supply & Fixing in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm complete all as specified and directed. |
| 81 | S&FCollapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed. |
| 82 | M & L applying two coats of synthetic enamel paint on new wooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and directed. |
| 83 | S & F PVC solid factory made door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tubecomplete all as specified and directed. |
| 84 | S & F stainless steelbutt hinges,100 mm long complete all as specified and directed. |
| 85 | S & F aluminium handles 150 mm long cast type, anodised completeall as specified and directed. |
| 86 | S & F aluminium anodised barrel tower bolts 150 mm long of extruded section and fixed completeall as specified and directed. |
| 87 | Supply and fixing stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm complete all as specified and directed. |
| 88 | Supply & Fixing in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm complete all as specified and directed. |
| 89 | S & F4.8 mm thick Frosted plain glass ordinary quality and glazing with oil putty or wooden beads in square area n. exc. 0.5 Sqm in each pane complete all as specified and directed. |
| 90 | S&F in repair chromium plated Hand shower (health faucet), brass body with 1.2 metre long flexible tube in chrome finish with wall hook complete all as specified and directed.(MAKE : JAQUAR, Cat No : ALD-573/ PARRYWARE, Cat No : T9941A1 / ESS ESS, Cat No: C-232D / CERA, Cat No: F8030401AB / HINDWARE, Cat No: F160002) orequivalent make specified in tender.) |
| 91 | Supply and fixvitreous china wash basin, white, counter top, size 450 x 400mm oval shape excluding taps, waste, chain and plug and porcelain stopper complete all as specified and directed . |
| 92 | S&F in repair Chromium plated brassAngular stop cock, fancy type,concealed type with wall flange fixed to 15 mm bore of Iron pipe complete all as specified and directed.(Make : JAQUAR, Cat No: CON-59KN / PARRYWARE, Cat No: G1453A1 / ESS ESS, Cat No: C-206 / CERA, Model: OCEAN / PRAYAG, Cat No: 9210 / HINDWARE, Cat No: F330043) orequivalent model in JAQUAR / CERA / PARRYWARE HINDWARE/PARRYWARE) |
| 93 | S&F in repair Chromium plated brassWall mixer, concealed type, with concealed body, with overhead shower arrangement fixed with 15 mm bore Iron pipe including taking down existing mixer complete all as specified and directed. (Make : Jaquar, Cat No : CON-273KNUPR / PRAYAG, Cat No: 9275 / CERA, Model: OCEAN / PARRYWARE, Cat No: G1417A1 / HINDWARE, Cat No: F200020 / ESS ESS, Cat No: C-216) orequivalent make specified in tender. |
| 94 | S&F in repair 15mm dia fancy type chromium plated basin mixer foam flow screwed for iron pipe incl taking down old all as directed by Engr-in-Charge. (MAKE : ESS ESS, Cat No : C-211A / JAQUAR, Cat No : CON-167KNB / PARRYWARE, Cat No: G1414A1 / CERA, Model: OCEAN / PRAYAG, Cat No: 9250 / HINDWARE, Model: CONTESSA PLUS) orequivalent make specified in tender. |
| 95 | S&Fin repair 15mm bore chromium plated two way bib cock with flange, fancy type complete all as specified and as directed.(Make : Ess Ess, Cat No: C-203 / JAQUAR, Cat No: CON-041KN/ PARRYWARE, Cat No: G1434A1/ CERA, Model : OCEAN / PRAYAG, Cat No: 9212/HINDWARE, CAT No: F330004CP) orequivalent make specified in tender. |
| 96 | S&F Chromium plated brass Towel ring (premium quality) complete all as specified and directed. (Make : Ess-Ess, Cat No: AC-502 / JAQUAR, Cat No: ACN-1121BN / PARRRYWARE, Cat No: T6002A1 / PRAYAG, Cat No: BA-11 orequivalent make specified in tender. |
| 97 | S&Ftoilet paper holder, surface type with flap incl taking down existing holder complete all as specified and directed. (Make : JAQUAR, Cat No : CAN-1153N / CERA, Cat No: F5007110 / PRAYAG, Cat No: BA-38 / ESS ESS, Cat No: AC-506 / HINDWARE, Cat No: F880003) orequivalent make specified in tender. |
| 98 | S&Fvitreous china floor mounted coupled closet (Pedestal pattern) white including low level vitreous china valveless symphonic action type flushing cistern with inlet ball valve float,push button, flush pipe incl bracket, P/S trap, PVC coloured seat cover and connecting fittingsincluding taking down existing water closet complete all as specified and directed |
| 99 | S&F corner glass shelf 200 mm with brass brackets, as in repair complete all as specified and directed. (Make: PRAYAG, Cat No: BEA-44 / JAQUAR, Cat No: ACN-1173 / PARRYWARE, Cat No: T6010A1 / CERA, Cat No: F5005102) orequivalent make specified in tender. |
| 100 | M & L cutting chases for concealed water tubing, pinning in, making good of facings where required and pointing in cement mortar 1:3to ends or edges etc, cutting not exceeding 10 cm width or girth, complete all as specified and directed |
| 101 | Taking down steel water tubing and connections, including cleaning for refixing or remove to store all as specified of following size. |
| 102 | 15 mm dia |
| 103 | 20 mm dia |
| 104 | S&F Tubes, \"medium grade\" galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 105 | 15 mm dia |
| 106 | 20 mm dia |
| 107 | E/M PortionTaking down copper/ aluminium point wiring (light, fan, buzzer, socketor power) complete including fixture and fittings such as switches, ceiling roses, pendants , regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc. |
| 108 | M & L for concealed point wiring with FRLSH grade PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size through and including PVC conduit terminated in modular switch boards for fixing of switches, sockets, fan regulators etc for the following [Note: - Modular switch boards shall be measured and paid separately]: - |
| 109 | All as per Item No 103above but one light point or one fan point controlled by one switch |
| 110 | One 3/5 pin socket outlet, 5 Amp independent |
| 111 | One 3/5 pin socket outlet, 5 Amp on the same board with other switches |
| 112 | M & L for concealed point wiring with FRLSH grade PVC insulated unsheathed multistranded copper conductor cables of 2.5 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 2.5 sqmm size through and including PVC conduit terminated in modular switch boards for fixing of switches/ sockets for one 3 pin socket outlet, 15 Amps, independent [Note: - Modular switch boardsshall be measured and paid separately] |
| 113 | S & F Modular Switch 1 way 6 A, 1 module complete all as specified and as directed. |
| 114 | S & F Modular Switch 1 way 16 A, 1 module complete all as specified and as directed. |
| 115 | S & F Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and as directed. |
| 116 | S & F Modular Socket outlet 6 A/ 16 A, 2/3 pin combined 2 module complete all as specified and as directed. |
| 117 | S & F Modular Bell push 6A, 1 modulecomplete all as specified and as directed. |
| 118 | S & F Modular Fan step regulator, 120W- 2 modulecomplete all as specified and as directed. |
| 119 | S & F Bell , AC, 230 Volts, single polecomplete all as specified and as directed. |
| 120 | S & F Modular type White cover plate with frame 3 modulecomplete all as specified and as directed. |
| 121 | S & F Modular type White cover plate with frame4 modulecomplete all as specified and as directed. |
| 122 | S & F Modular type White cover plate with frame 6 modulecomplete all as specified and as directed. |
| 123 | S & F Modular type White cover plate with frame 8 modulecomplete all as specified and as directed. |
| 124 | S & F Modular type White cover plate with frame 12 modulecomplete all as specified and as directed. |
| 125 | S & F Modular type Metal Flush box 3 modulecomplete all as specified and as directed. |
| 126 | S & F Modular type Metal Flush box 4 modulecomplete all as specified and as directed. |
| 127 | S & F Modular type Metal Flush box 6 modulecomplete all as specified and as directed. |
| 128 | S & F Modular type Metal Flush box 8 modulecomplete all as specified and as directed. |
| 129 | S & F Modular type Metal Flush box 12 modulecomplete all as specified and as directed. |
| 130 | S & F Ceiling rose, 3 terminal PVC insulated body complete all as specified and as directed. |
| 131 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 132 | S & F in repair Recess mounting LED 12 Watt Slim round down lighter made of Green Perform sleek is a high performance low-height LED modern professional workspace. Robust PDC housing ensures long system. make Philips Cat - DN295B LED10S-6500 PSU WH or equivalent make specified in tender. |
| 133 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louverscomplete all as specified and as directed. |
| 134 | Supply and Fix in repairs Recess Mounted LED luminaire suitable for 600 x 600 snap grid ceiling with constant current driver with in built protection against lightning, over voltage & short circuit complete with all accessories with and including 36 Watt LED 6000K (having minimum efficacy of 110 lumen/watt) and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor cable of size 1.5 sqmm (nominal area) complete all as specified and directed. |
| 135 | S & F Socket for AC short circuit protection motor starterwith MCB DP 25 Amps capacity AC230 Volt with Plug Top with Indicator complete all as specified and directed. |
| 136 | M & L for sub main wiring with 4 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and including PVC casing-capping of suitable size, surface type all as directed. |
| 137 | All as per Srl. Item No. 128above but with 2 run of 6.0 Sqmm cable and 6.0 Sqmm as earth continuity conductor. |
| 138 | All as per Srl. Item No. 128 above but with 2 run of 4.0 Sqmm cable and 4.0 Sqmm as earth continuity conductor. |
| 139 | S & F Sheet metal enclosure for MCB DB double door Triple pole & Neutral 4 way with 200 amps rated bus barcomplete all as specified and as directed. |
| 140 | Supply only MCB Four pole, 415 volts, 63 Amps, breaking capacity 10KAcomplete all as specified and as directed. Make :Cat No 408702,of Legrand or equivalent make specified in tender. |
| 141 | S & F Sheet metal enclosure for MCB DB double door 240V single pole & Neutral 8 way with common bus bar complete all as specified and as directed. |
| 142 | S & F MCB \"C\" series single pole 5 to 32 Amps, breaking capacity 10KA. complete all as specified and as directed. Make :Cat No. 408587of Legrand or equivalent make specified in tender. |
| 143 | S & F MCB \"C\" curve single pole neutral , 40 to 63 Amps with breaking capacity 10kA, complete all as specified and as directed. Make: Cat no. 6033 26 of Legrand or equivalent make specified in tender. |
| 144 | Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1400mm sweep, with Squirrel cage induction motor complete all as specified and as directed. |
| 145 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed. |
| 146 | Refixing of point wiring obtained from item no. 1with existing 1.5 sqmm PVC insulated stranded copper conductor single coreincluding PVC conduit of appropriate size concealed in wall, pressed steel concealed terminal boxes of required size and with modular boxes, painting terminal boxes inside and out side with one coat red oxide primer complete with all accessories and all as specified with existing 1.5 Sqmm PVC insulated unsheathed multistranded copper earth conductor to common earth and connected to earth dollyfor fan / light / exhaust fan/ bell point controlled by one switch.Note:- 1. M&L for cutting chases on walls / ceilingand making good disturbed surfaces including finishing with cement mortar (1:3) etc;and screws nut and bolts required for fixing shall be deemed to be included in the rate quoted above. |
| 147 | All as Per Item No.138but for One 3 pin socket outlet, 5 Amp independent |
| 148 | All as per item no. 138 but for One 3 pin socket outlet, 5 Amp on the same board with other switches |
| 149 | All as per item No 138 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed,cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 2.5 sqmm multi stranded copper conductor as continuous earth wire with lugs complete all as specified and directed. |
| 150 | Taking down and refixing Sheet metal enclosure for MCB DB double door single pole & Neutral 4/6/8 /12 as per existing at site way with common bus bar complete all as specified and directed. |
| 151 | Taking down and refixingMCB \"B\" curve single pole neutral , 32 Amps with breaking capacity 10kA, complete all as specified and directed. |
| 152 | Taking down and refixing MCB \"B\" series single pole 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. |
| 153 | Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed. |
| 154 | Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth and getting out, complete all as specified and as directed. NOTE : Quoted Unit Rate shall deem to be included Materials and Labour required for repairing to damaged Road/ Hardstanding to match the existing Surfaces and Specifications. |
| 155 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed. |
| 156 | Removing excavated materials not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed. |
| 157 | M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180Cm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured. |
| 158 | Supply & laying in Trenches Sub-class ‘B’ Bricks, kiln burnt, for Cable Protection, complete all as specified and as directed. |
| 159 | Laying in Trenches Bricks (Serviceable Bricks obtained from Item No. 9.00 here-in-after), for Cable Protection, complete all as specified and as directed. |
| 160 | Supply, Laying and testing for replacement of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall with saddles/Flat iron clamps as per site requirement /passing through pipe/pole complete of the following sizes and cross sectional area :-Note :-Necessary earth work to be measured and paid separately. (a)35 Sqmm, 3.5 Core |
| 161 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 240 Sqmm, 3.5 core including taking out old unserviceable cable complete all as specified and directed. |
| 162 | Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm(upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed. |
| 163 | Supply and fixing GI tubing 50mm bore (light grade) in trenches/floor/fixed along pole for cable incl taking down old unsv pipe complete all as specified and as directed by Engineer-in-Charge. |
| 164 | Supply and fixing 80 mm bore galvanized iron pipe (light grade) with all fittings, fixedin trenches/floor/fixed along pole for cable incl taking down old unsv pipe complete all as specified and as directed by the Engineer-in-charge. |
| 165 | Supply and fixing 100 mm bore galvanized iron pipe (light grade) with all fittings, fixedin trenches/floor/fixed along pole for cable incl taking down old unsv pipe complete all as specified and as directed by the Engineer-in-charge. |
| 166 | Note: Schedule of credit (SCHEDULE OF CREDIT)amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |