Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | REPAIR TO DESERT COOLER (Summer King/AVIN/SummerCool/Khaitan /ANY OTHER MAKE) |
| 2 | Disconnection,takingdown desertcoolersfrom anyfloor of building and cleaning /removing of old paint andpaintingwith twocoatof enamelledpaintof colour as specified by Engr in charge over a coat of red oxide and internallywith black bitumenouspaint complete all as specified and directed. |
| 3 | S&F in repair of following spares parts of desert coolers of different sizes including testing complete after dismantling of old respective unserviceable spares complete all as specified and directed. |
| 4 | S& F Desert cooler body fabricated with 20 mm gaugemetallic sheet of GIwith side grills filled with wood wool pads, front grill and equiped with one piano switch, selector switch, PVC distributors and PVC pipes complete all as specified and directed. |
| 5 | S & F Electric Fan motorexhaustexhaust fan turbo force 450 mm sweeptype heavy duty of Desert/air cooler of capacity 1300-1400 RPMsingle shaftof power rating 100 - 150 watt 230 Volt 50 Hz Single phase Make- Summerking/Summercool/Khaitan |
| 6 | S& F Electric Fan motor of Desert/air cooler of capacity 1300-1400 RPMsingle shaftof power rating 100 - 150 watt 230 Volt 50 Hz Single phase Make- Summerking/Summercool/Khaitan complete all as specified and directed. |
| 7 | S& F Waterliftingsubmersible type tullu pump 18 watt and water lifting upto 1.8 Mtr for desert coolers Make- Summerking/Summercool complete all as specified and directed. |
| 8 | S& F Float valve plastic ball for 15 mm dia bore of pipe of desert cooler with ISI mark complete all as specified and directed. |
| 9 | S& F PVC stop cock suitable for 15 mm dia GI pipeISI Mark complete all as specified and directed. |
| 10 | S& F PVC connection 15 mm dia with CP nut 450 mm long ISI Mark complete all as specified and directed. |
| 11 | S& F Capacitor 4 MFD of make Usha/Asain/Epcos/ISI complete all as specified and directed. |
| 12 | S& F Set of legs with clamp and nut bolt & washer for mounting of fan motor on body for desert cooler complete all as specified and directed. |
| 13 | S& F Aluminium Fan leaf blade complete all as specified and directed. |
| 14 | S& F PVC fan leaf blade complete all as specified and directed. |
| 15 | S& F Iron Standmade out of angle iron of each size 35x35x4mm forinstallationof desert cooler of height3 to 6 feet, lengthxwidth as per site requirement on the ground floor,/Ist /2nd floor complete all as specified and directed. |
| 16 | S& F Switch regulator with controlling knob low med high controlof any size complete all as specified and directed. |
| 17 | S& F Wood wool pad, each packet set of three(Note: Tie strip for fixing of pads must be included in the quoted rate) complete all as specified and directed. |
| 18 | S& F Wire mesh of Pannel doors/side grills for supporting of Wood wool grass pad of size as required at site as per panell door size complete all as specified and directed. |
| 19 | S& F PVC water distributor heavy duty 15mm size fixed with bolts & Nut & washers complete all as specified and directed. |
| 20 | S& F PVC elbow 15mm diafor inside water distribution complete all as specified and directed. |
| 21 | S& F Front grill suitable for desert coolers complete all as specified and directed. |
| 22 | S& F Plug top 3 pin 5/6 Amps, 230 Voltcomplete all as specified and directed. Make: Anchor/Schenider/Havells |
| 23 | S& F Piano type switch 5/6 Amps, 230 Volt complete all as specified and directed.Make: Anchor/Schenider/Havells |
| 24 | S& F Flexible Copper Cable 2 Core multistranded, PVC insulated ofsize 70/.0076 for internal wiring of desert cooler complete all as specified and directed. Make: Plaza/Havells/polycab |
| 25 | S& F Two core connection lead cable,PVC insulated and sheathed Copper cable size 1.5 Sqmm complete all as specified and as directed Make: Plaza/Havells/Polycab |
| 26 | S& F PVC flexiblewater tubing pipe of 15 mm dia heavy duty for desert cooler inside water distributing complete all as specified and directed. |
| 27 | S& F GI Water tubing medium grade of bore dia 15 mm with all fittingsfor connection of Desert cooler water pipe line including fixing with clamp and fiitings complete all as specified and directed. |
| 28 | S& F GI sockets/union/elbow/tee of size 15 mm complete all as specified and directed. |
| 29 | REPAIR OF WATER COOLER 80/40,60/120,150/150, 150/180, LTR (Bluestar/Voltas /USHA/ANY OTHER MAKE) |
| 30 | S& F Maintenance/ Servicing of water coolers 40/80/,60/120,150/150,150/180 Ltrs Capacityby removing , cleaning the dust and dirt and mud from water storage tank andtray and from the complete unit, cleaning of water tank, cleaning of condensingcoil using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasingcondenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning complete all as specified and directed. |
| 31 | S& F Taking down/outbycuttingunserviceablecompressor unit from the machine of size 180/150/120/60/80/40and of differnt capacity ltrs capacityincludingflushingout/cleaningof refrigeratorsystem by CTD/Nitrogen gas complete all as specified and directed. |
| 32 | S&F compressor(sealed unit) withcharging of refrigerant gascompleteand testingon full load. for followingcapacityinWater Cooler all as specified and as directed by Engineer-in-Charge complete all as specified and directed.Make:LG/Emerson |
| 33 | S& F 180/150ltrs capacity of water Cooler complete all as specified and directed. |
| 34 | S& F 60/120ltrs capacityof water Cooler complete all as specified and directed. |
| 35 | 40/80ltrs capacity of water Cooler |
| 36 | S&F in repair of following spares parts of water cooler of40/80/,150/180, 120/160 Ltrs Capacity including testing complete after dismantling of old respective unserviceable spares complete all as specified and directed. |
| 37 | S& F Capacitor 36 MFD, complete all as specified and directed.Make-Asian/Epcos/Siemns/ISI |
| 38 | S& F Capacitor 10 MFD complete all as specified and directed. Make-Asian/Epcos/Siemns/ISI |
| 39 | S& F Starting capacitor 80/100 Mfd of complete all as specified and directed. Make Unistar/Usha/Asian/ISI |
| 40 | S& F Thermostat switch assly of suitable size complete all as specified and directed.Make -Indfoss/classic/danfoss |
| 41 | S& F Overloadprotector Relayfor water cooler of makes as above complete all as specified and directed. Make -Indfos/classic/danfoss |
| 42 | S& F Blower motor 1/5 HP with mounting stand for water cooler of different capacityfor watercoolers complete all as specified and directed. |
| 43 | S & F Fan leaf blade of blower motor for water cooler of different capacityfor watercoolers complete all as specified and directed. |
| 44 | S& F Float valve complete with PVC balland brass spindle for size 15 mmbore of pipe in water coolers of makes as above complete all as specified and directed. |
| 45 | S& F PVCconnectionwith brassunion nut 450 mm longsuitablefor15 mm GI pipe in water coolers of makes as above complete all as specified and directed. |
| 46 | S& F Pushcock (Push Tap) cast copperalloy chromiumplatedheavy dutycomplete of size 15 mm of suitable type as per site requirement complete all as specified and directed. |
| 47 | S& F Drain pipe flexible including clamp for water cooler after repair of leakage of water tray complete all as specified and directed. |
| 48 | S& F Plug top 3 pin 15 Amps, 230 Volt complete all as specified and directed. Make: Anchor/Schenider/Havells |
| 49 | S& F Supply and fixing of Connection Pipe and socket for connection of Water cooler from Aquaguard /water purifier complete all as specified and as directed. |
| 50 | S& F Repairto top coverof water cooler including replacement of rubber Gasket and locks complete including replacement of old nut andbolts, screws,hinges etc. complete all as specified and directed. |
| 51 | S& F Repairto bodyof water cooler including water tray of anymake/sizecapacityby weldingof MS sheet not lessthan 1.6sqmmthick to matchwith existingafterremovingold rusted/unserviceableportion includingpainting and replacement of old nut andbolts, screws,hinges etc. complete all as specified and directed. |
| 52 | M&Lfor removingof dents, putty filling, spraypainting with two coatsof syntheticenamelled paint afterpreparationof surfaces by burning of old paint for water cooler of 180/150/120/60/80/40 ltrs capacity for makes as above complete all as specified and directed. |
| 53 | Repair to Split Type/Window Type AC 1/1.5/2.0 TONMake : (Carrier/LG/Haier/Hitachi/Bluestar/Samsung/Panasonic/videocon/Voltas) |
| 54 | Maintenance and Servicingof split type air conditioner of capacity 1.5/2.0 TR of any make and type by removing , strip opening, cleaning the dust and dirt from the complete unit, cleaning of air filter, cleaning of condensingand cooling coil and complete outdoor and indoor unit using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasingof blower & condenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning complete all as specified and directed. |
| 55 | Maintenance and Servicingof Window type air conditioner of capacity 1.0/1.5/2.0 TR of any make and type by removing , strip opening, and taking out the window type AC from the cabinet frame and cleaning the dust and dirt from the complete unit, cleaning of air filter, cleaning of condensingand cooling coil using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasingof blower & condenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning complete all as specified and directed. |
| 56 | Takingdown/out unserviceablesealed/rotary/Reciprocating type compressor unitfromthe outdoor unit of Split type AC/ Window type ACs of makes-Carrier/LG/haier/blue star/Voltas and any other make of capacity 1/1.5/2.0 Toncapacityincludingflushingofcoolingsystem byNitrogen gas complete all as specified and directed. |
| 57 | compressor(sealed unit)of followingcapacityinSplit type/window type Air Conditioner complete and testing on full loadcomplete all as specified and directed. Make:LG/Hitachi/Emerson/Carrier |
| 58 | (a)Reciprocating type1.5 Ton complete all as specified and directed. |
| 59 | (b)Reciprocating type2.0 Ton complete all as specified and directed. |
| 60 | (c)Rotterytype1.0 Ton complete all as specified and directed. |
| 61 | (d)Rotterytype1.5 Ton complete all as specified and directed. |
| 62 | (e)Rotterytype 2.0 Ton complete all as specified and directed. |
| 63 | Supply, fixing , installation ,commissioning and testing of indoor unit complete with remote and valves of capacity 1.5 TR suitable for fixing up in the existing model ofoutdoor unit of Split ACs complete after disconnecting electrical connection and dismantling/ taking out indoorunit of split type ACs of any make and capacity from any placeandfixing of the same after recharging of refrigerant gas including transportation cutting of hole on wall and making good of disturbed surface with matching colour/distamper all as directed by Engineer-in-Charge complete all as specified and directed. Make: LG/Voltas/Carrier/Bluestar/Hitachi/Samsung |
| 64 | Ditto- all as above but of indoor unit capacity 2.0 Ton complete all as specified and directed. |
| 65 | S&F in repair of following spares parts of Split type/Window type ACs of capacity 2.0/1.5/1.0 Ton including testing complete after dismantling of old respective unserviceable sparescomplete all as specified and directed. |
| 66 | S& F Remotesuitable for various makes of Split type/Window ACs for 1/1.5/2.0 Toncapacity complete all as specified and directed. Make: LG , Carrier, Voltas, Bluestar, Hitachi |
| 67 | S& F Condenser motor of outdoor unit for 1.5/2.0 Ton capacity of AC as per existingmakes complete all as specified and directed. |
| 68 | S& F Indoor motor of Blower for 1.5/2.0 Ton capacity of split AC as per existingmakes complete all as specified and directed. |
| 69 | S& F Condenser PVC blade of fan motor for 1.5/2.0 Ton Split AC complete all as specified and directed. |
| 70 | S& F SP plug and socket insheet steel enclosure includingSP MCB 32 Amps complete all as specified and directed. Make : HPL/Havells/L&T |
| 71 | S& F Running capacitor50/2,/50/6 Mfd ofsuitablesize make Epcos/Asian/Max/Sharda or equivalent as per ISI for ACs complete all as specified and directed. |
| 72 | S& F Running capacitor45 Mfd ofsuitablesize make Epcos/Asian/Max/Sharda or equivalent as per ISIfor ACs complete all as specified and directed. |
| 73 | S& F Starting capacitor100/120 Mfd ofsuitablesize make Epcos/Asian/Max/Sharda or equivalent as per ISIfor ACs complete all as specified and directed. |
| 74 | Indoor capacitor of size 1.5 MFD/2 MFD suitable for 1.5/2.0 Ton AC complete all as specified and directed. |
| 75 | S& F Swing motor suitable for indoor unit of 1.5/2.0 Ton Split type AC complete all as specified and directed. |
| 76 | S& F Contactor suitable for 1.5/2.0 Ton AC as per make/size approved by Engr-in-Charge complete all as specified and directed. L&T/C&S/SIEMENS |
| 77 | S& F Copper tubing of size 3/8\" including cutting and brazing all as directed by Engr-in-Charge complete all as specified and directed. |
| 78 | S& F Copper tubing of size 5/8\" including cutting and brazing all as directed by Engr-in-Charge complete all as specified and directed. |
| 79 | S& F Copper tubing of size 1/4\" including cutting and brazing all as directed by Engr-in-Charge complete all as specified and directed. |
| 80 | S& F Copper tubing of size 1/2\" including cutting and brazing all as directed by Engr-in-Charge complete all as specified and directed. |
| 81 | S&Fthree core connection lead two single core,PVC insulated and sheathed Copper cable size 2.5 Sqmm including oneearthwire of full guagecomplete all as specified and as directedcomplete all as specified and directed. Make : Plaza/Havells/Polycab |
| 82 | S&F Nitril vinyl insulation foam suitable for fixing with copper tube of size 3/8\", 5/8\" , 1/2\" and 1/4\" and packing with wide pvc tapes of black/white colour compete all as specified and directed. |
| 83 | S& F Reverse valve suitable for 1.5/2 ton ACs including dismantling and reinserting of valve and refilling of reqd refrigerant and testing all as specified and directed by Engr-in-Charge |
| 84 | S& F Wall/floor mounting type iron stand for outdoor unitcomplete all as specified and as directed |
| 85 | S& F Dead plug made out of brass of sizes5/8\" ,3/8\" , 1/4\" & 1/2\" as per requirement on sitefor outdoor unit valves complete all as specified and directed. |
| 86 | S& F Pin Valve made out of brass for compressor of Acs complete all as specified and directed. |
| 87 | S& F Brass Thimble/U clip lugs made out of brass for internal connection & wiring of ACs of 100 pcs per Pkt complete all as specified and directed. |
| 88 | S& F Suction valvesmade out of brass of size 5/8\"/1/2\"/3/8\"/1/4\" as per required for outdoor unit of split type Acs complete all as specified and directed. |
| 89 | S& F Discharge valvesmade out of brass of size 5/8\"/1/2\"/3/8\"/1/4\" as per required for outdoor unit of split type Acs complete all as specified and directed. |
| 90 | S& F Blower complete with fins suitable for indoor unitofSplit type ACcomplete all as specified and directed. |
| 91 | S& F Metal clad socket of 20 Amps 240 volts forAC complete all asspd and directed. complete all as specified and directed. Make:Havells/Schneider/Anchor/L&T |
| 92 | S& F Metal clad Plug top of 20 Amps 240 volts forAC complete all asspd and directed. Make:Havells/Schneider/Anchor/L&T |
| 93 | S& F Electronic PCB card complete with Display and sensor complete for split AC indoor unit of any make as per requirement at site complete all as specified and as directed. Make: LG, Carrier, Voltas, Bluestar,Hitachi |
| 94 | S& F Display unit with sensor complete for split AC indoor unit of any make as per requirement at site complete all as specified and as directed. Make: LG, Carrier, Voltas, Bluestar |
| 95 | S& F Unplasticised PVC pipes25 mmouter dia of pressure rating100 Kg/Cm2 for drain of water of split type ACs fixed complete to walls,ceilings or in floors etc,including chase cutting on wall & making good as per existing complete all as specified and as directed. |
| 96 | S& F Air dustfilterfor indoor unit of Split type ACsfor 1.5/2.0 Tonnecapacityof Acs complete all as specified and directed. |
| 97 | S& F Relayfor 1.5/2.0 Ton of makes Classic/Indfos/Annapurna for Split/window ACs complete all as specified and directed. |
| 98 | S& F Thermostat Switchfor 1.5/2.0 Ton of makes Classic/Indfos/Annapurna for window ACs as makes above complete all as specified and directed. |
| 99 | S& F Air dustfilterfor window type ACs for 1.5/2.0 Tonnecapacityof ACs as per makes above complete all as specified and directed. |
| 100 | S& F Switch Controlling Knob complete with high low med function for 1/1.5/2.0 Tonnecapacityof window type Acs complete all as specified and directed. |
| 101 | S& F Condenser motorfor 1/1.5/2.0 Ton capacity of window type AC as per site requirementcomplete all as specified and directed. |
| 102 | S& F Condenser PVC round Fan Blade for 1/1.5/2.0 Ton window type AC Make : Carrier/LG/Bluestar /Videocon/Onida/Samsung complete all as specified and directed. |
| 103 | S& F Front grill suitable for 1.5/2.0 Ton window type AC complete all as specified and directed Make : Carrier/LG/Bluestar /Videocon/Onida/Samsung |
| 104 | S& F MCB SP 32 Amps 230 Volt used in the DB/MCB Enclosure Box of ACs complete all as specified and directed. |
| 105 | S& F MCB SP 25 Amps 230 Volt used in the DB/MCB Enclosure Box of Acs complete all as specified and directed. |
| 106 | Supply and gas charging withrefrigerentgas required in any make and type of splitand window type ACs to itsfull capacity where less gas detected in the split type and window type air conditioners complete all as specified by Engr in charge |
| 107 | S& F Taking down unserviceable PCBs card with sensors of Split/Window type AC and refix the same after complete repair and testingas of Cap 1.5/2.0 ton as directed by Engr-in-charge. |
| 108 | Taking down unserviceable condensor coil from outdoor unit of Split AC or from Window type ACs and Supply & Fixing and installation of condenser coil by brazing and testing complete by refilling the refrigerantgas after flushing with nitrogen gas complete all as directed by Engr-in-charge. |
| 109 | Shifting/Fixing by disconnecting electrical connection and dismantling/ taking out indoor and outdoor unit of split type air conditioning of any make and capacity from any placeandinstallation, commissioning and testing to another location including transportation cutting of hole on wall and making good of disturbed surface with matching colour/distamper all as directed by Engineer-in-Charge. |
| 110 | S& F Shifting/Fixing by disconnecting electrical connection and dismantling/ taking out window type air conditioning complete with frame cabinet of any make and capacity from any placeandinstallation, commissioning and testing to another location including transportation cutting of hole on wall and making platform complete with wooden strip/iron frame for fixing of Window AC Cabinet and making good of disturbed surface with matching colour/distampercomplete all as specified and directed. |
| 111 | S& F REPAIR OF VOLTAGE STABILIZER 1/2/3/4/ 5 KVA (Bluebird/Blueline/Sinetrac/Vintec/ANY OTHER MAKE) |
| 112 | S& F Opening/ strippingof voltage stablizer of capacity ranges 1 to 5 KVA make- Bluebird/Bluline/Sinetrac/Vintec/ V Guard/any other makeforcheckingof componentsfor theirserviceablityas per makes above and repair to its internal circuits and wiring including minor repair to circuit plate and refix to its original position all as specified and directed |
| 113 | All as Per Srl Item No 111 above here-in-before but for capacity 7.5 KVA complete all as specified and directed. |
| 114 | S& F Rewinding of main transformer with super enamelled coper wire of suiltable size or guage including insulation material applying varnish and drying properly at slow temprature, , replacing nut bolts with washer including removing of burn wire of voltage stablizersingle phase 220 V of 1 to 2 KVA complete all as specified and directed. |
| 115 | All as Per Srl Item No 113 above but for 3 KVA. |
| 116 | All as Per Srl Item No 113 above but for 4KVA. |
| 117 | All as Per Srl Item No 113 above but for 5KVA. |
| 118 | All as Per Srl Item No 113 above but for 7.5 KVA. |
| 119 | S&F in repair of following spares parts of Voltage stabilizer single phase of cap 2/3/4/5/7.5 KVAincluding testing complete after dismantling of old respective unserviceable spares complete all as specified and directed. |
| 120 | S& F Trigger transformer of suitable for 2 to 3 KVAcomplete all as specified and directed. |
| 121 | S& F Trigger transformer of suitable for 4 to 7.5KVA complete all as specified and directed. |
| 122 | S& F Circuit Plate 2 to 7.5 KVA complete all as specified and directed. |
| 123 | S& F VoltMeterindicating 100to 300volt make AE for stabilisers as per make above complete all as specified and directed. |
| 124 | S& F Time Delay Relay Systemfor 2 to 3 minuteswithhighcutabove 250volt and low cut 190 Vin 2 to 7.5KVA V/stablizer complete all as specified and directed. |
| 125 | S& F Circuit jack/ST3 socket for in out connection platecomplete all as specified and directed. |
| 126 | S& F Walk-in Coolers & Mortury cabinets MAKE :Bluestar/ANY OTHER MAKE |
| 127 | S& F Maintenance/Servicing of Walk-in- cooler/Mortuary Cabinet of any size and type by removing , cleaning the dust and dirt from the complete unit, defrosting and cleaning of cabinet, cleaning of condensingcoil using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasingcondenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning complete all as specified and directed. |
| 128 | S&F in repair of following spars parts of Walk-in Coolers cold storage and mortury cabinets of different sizes including testing complete after dismantling of old respective unserviceable spares complete all as specified and directed. |
| 129 | S& F Compressor(sealed unit)of cap 1.5/2.0 Ton/ esixting capacity in mortury cabinet/walk-in coolers cold storage complete and testing on full load all as specified and as directed complete all as specified and directed. |
| 130 | S& F Electricblower motor ofWalk-in Cooler cold room/mortuary cabinet for indoor blower unit of existing make and capacity complete with grills complete all as specified and directed. |
| 131 | S& F Contactor switches of suitable sizes for outdoor units of walk-in coolers and mortury cabinets complete all as specified and directed. |
| 132 | S& F Running capacitors of sizes 50/6 MFD for outdoor units complete all as specified and directed. |
| 133 | S& F Indoor motor capacitors complete all as specified and directed. |
| 134 | S& F Sub Zero Temperature Controller for Walk-in- Cooler Cold Storage complete all as specified and directed.Make -Danfoss/Thermo Sensors |
| 135 | S&F in repair of Mortuary Cabinet door handles with locks complete of existing makes and sizes and repair of dents and rusting in the mortury cabinetand testing completere-assembling, re-installing in the original position and testing for proper cooling and smooth functioning complete all as specified and directed. |
| 136 | M&L for repair of floor of walk-in cooler cold room by using suitable metallic flooring sheets and welding works and insulation thermocol materials works and refixing of matting and repair of dents and rusting complete all as specified and directed for proper cooling and smooth functioning complete all as specified and directed. |
| 137 | M&L for repair of door locks, handles and hingesof walk-in cooler cold room complete all as specified and directed. |
| 138 | S& F Repair of PCB circuit plateincluding display card sensor & switches by disconnecting and refixing the same after complete repair and testing of walk-in cooler cold room by using suitable cement works and refixing ofmetallic flooring and repair of dents and rusting including repair of door locks complete all as specified and directed for proper cooling and smooth functioning complete all as specified and directed. |
| 139 | REFRIGERATOR 320/310/280/215/180/185/165 LTR MAKE: LG/GODREZ/Whirlpool/Kelvinator ANY OTHER MAKE |
| 140 | Repair and Maintenance of refrigerator ofCapacity 165 to 400 Ltrs by removing ,strip opening, cleaning the dust and dirt from the complete unit, defrosting and cleaning of cabinet, re-assembling,dismantling the unserviceable parts & re-installing in the original position after replacement of U/S parts and testing for proper cooling and smooth functioning complete all as specified and directed. Make-LG/GODREZ /Samsung/Voltas/Whirlpool/any other make |
| 141 | Repair and Maintenance of deep freezers 310/320 Ltrs by removing , cleaning the dust and dirt from the complete unit, defrosting and cleaning of cabinet, cleaning of condensingcoil using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasingcondenser fan motor etc re-assembling, re-installing in the original position after replacement of U/S parts and testing and testing for proper cooling and smooth functioning Make-LG/Samsung/Voltas/Bluestar any other make |
| 142 | Takingdown by cuttingunserviceable Sealed/rotary compressor unit from the refrigerator/deep freezer machineof size310/320/300/280/215/170/165 litres capacity of MAKE LG/GODREZ /Whirlpool/ANY OTHER MAKE includingflushing outrefrigerationsystem such as condensor tubing capilleryevaporatorby nitrogengas complete including cleaning complete all as specified and directed. |
| 143 | S&F compressor(sealed unit)for followingcapacityinRefrigerators/Deep Freezers complete and testing on full load after reharging of refrigerant all as specified and as directed by Engineer-in-Charge Make: LG/Samsung/Voltas/Whirlpool/Bluestar a |
| 144 | S& F 350/400/500 ltrs capacitydeep freezers completeand testingon full load complete all as specified and directed. |
| 145 | S& F 310/280ltrs capacityrefrigerators/deep freezers completeand testingon full load complete all as specified and directed. |
| 146 | S& F 215 ltrs capacityRefrigerators completeand testingon full load complete all as specified and directed. |
| 147 | S& F 180/165 ltrs capacityRefrigerators completeand testingon full load complete all as specified and directed. |
| 148 | Supply and gas charging withrefrigerentgas used for any type and make of water coolers, refrigerators, deep freezers,walk-in cooler/mortury cabinetsto itsfull capacity where less gas detected in the Water coolers,deep freezers, refrigerators and walk-in-coolers/cabinets complete all as specified by Engr in charge |
| 149 | S&F in repair of following spares parts of refrigerators/deep freezers of different sizes including testing complete after dismantling of old respective unserviceable spares complete all as specified and directed. |
| 150 | S& F Thermostat switch suitable different capacityrefrigerator complete all as specified and directed.Make: LG/Whirlpool/Samsung |
| 151 | S& F Relay & Overload assembly universal type/Chip typecomplete suitable for all type of Refrigeratorsas per the existing model/size.complete all as specified and directed. |
| 152 | S& F Freezer with doorof suitablemake and size as per the existing model/size complete all as specified and directed. |
| 153 | S& F Cooling coil cabinet complete for refrigeratorsof suitablemake and size as per the existing model/size.complete all as specified and directed. |
| 154 | S& F Door light switch (push button type )with lamp holder of any makeandsize as per the existing model/size. |
| 155 | S& F Electric blower fan motor of existing capacity in deep freezers complete all as specified and directed. |
| 156 | S& F Electric bulb 15watt 250 V AC or pin typeof make Philips or equivalent complete all as specified and directed complete all as specified and directed. |
| 157 | S& F Evaporator/condenser coil assembly for capacity 165 to 310 Ltrs including brazing and fixing and testing complete all as specified and directed. |
| 158 | S& F Capillary 0.33 mm dia of brassincluding brazing and fixing and testing complete all as specified and directed. |
| 159 | S& F Magnetic door gasket/rubber beading for capacity 165 to 310 Ltrs complete all as specified and directed. |
| 160 | S& F Taking down unserviceable PCBs card with sensors of Refrigerators of inverter model or any make and type and refix the same after complete repair and testingcomplete all as specified and directed. |
| 161 | M&L for sub main wiring with two single core 4.0 Sqmm (FRLS)copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm (FRLS) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified.( Note :-Two runs of 4.0 sqmm (FRLS) and one run of 4.0 sqmm (FRLS) copper conductor shall be measured as one unit length.) |
| 162 | Notes:-1.The time limit forattending the job/complaints complaints within 24 hour.2In case the contractor fails to attend/rectify the defects within the above time limit i.e 24 Hrs (excluding reapair of Electronic PCB cards and replacement of compressor in which a specified time duration of 3 days required) penalty will be imposed as under :-Rs 200/- per day per complaints for first seven days after that Rs 500/- per day per complaint. 3. The representative of contractor shall report to the E/M refrigeration Sec complaint cell on all working days to receive the complaints.4. A register shall be maintained by the contractor/his Rep to record the complaints and its progress.5. A separate Docket complaints slip book shall maintained by the contractor to note the complaints/jobs and get it signed by the user after completion of work and submits to the JE-in-Charge. (6) Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail