| 1 | Excavating in trenches in soft/loose soil n. exc 1.5m wide and n. exc1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10sqm on plan and n.exc 1.5m in depth and getting out. in soft/loose soil complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 3 | M&L for Sand filling under floors or in foundationincluding watering and consolidatedand compacted with clean dry sand complete all as specified and directed. |
| 4 | M&L for sand cushioning for protection of underground cable, consolidatedand compacted with clean dry sand complete all as specified and directed. |
| 5 | Removing excavated material (soil) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 6 | M&L for hardcore of gauge n.exc. 63 mm,with broken stone and boulder, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surfaces complete all as specified and directed. |
| 7 | M&L for cement concrete type D2, 1:4:8using 40mm graded crushed stone aggregate as in foundations filling and mass concrete complete all as specified and directed. |
| 8 | M&L for PCC 1:3:6 type C-1 using 20mm graded crushed stoneaggregate as in hold fast andblock fillingof pressed steel chowkat including necessary form work if reqdetc complete all as specified and directed. |
| 9 | M&L for RCC(Nominal mix) type A1, 1:1.5:3 (using 20mm graded crushed stone aggregate) as in foundation,including rafts,footings,foundation beams plinth beams bases for columns etc. complete all as specified and directed. |
| 10 | M&L for R.C.C, Nominal mix of 1:2:4 using 20 mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc all as specified and directed. |
| 11 | M&L for R.C.C 1:2:4 (Nominal mix) type B-1using 20 mm graded stone aggregate for Chajjasand like etc. complete all as specified and directed. |
| 12 | M&L for R.C.C 1:1.5:3 (Nominal mix) type A-1 using 20 mm graded crushed stone aggregatefor Beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and directed. |
| 13 | M&L for RCC(Nominal mix) type A1, 1:1.5:3 (using 20mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts etc. complete all as specified and directed. |
| 14 | Supply only integral water proofing compound liquid grade conforming to IS-2645 complete all as specified and directed. (Pidiproof of Dr.fixit or equivalent) |
| 15 | M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 16 | M&L well burnt old size sub Class ‘B’ bricks, laid flat,in trenches for cable protection complete all as specified and as directed by the Engineer-in-Charge. |
| 17 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical to rough finished surface complete all as specified and directed. |
| 18 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping) rough finished surface flat complete all as specified and directed. |
| 19 | M&L for formworkto chullah hoods, chajjas, troughs and similar items in cluding edgescomplete all as specified and directed. |
| 20 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed. |
| 21 | M&L for formwork to sides of pillars, posts, struts, piers,columns and stanchions rough finished surfaces of concrete, square, rectangular or polygonal in shape complete all as specified and directed. |
| 22 | S&F 35mm thick factory made flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 23 | S&F 200mm aluminium anodised barrel tower bolts of extruded sectioncomplete all as specified and directed. |
| 24 | S&F 300 mm long aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) andfixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and direcetd. |
| 25 | M&L for MS framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165complete all as specified and directed. |
| 26 | M&L forTMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 27 | M&L forTMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 28 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 conforming to Fe 410 -W (Gde E- 250) quality A complete all as specified and directed. |
| 29 | S&F steel window with side hunge shutters including projecting type hinges with steel handle and steel peg stey, tower bolts etc. complete with glazing bars dovetailed or weldedcomplete all as specified and directed. |
| 30 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed. |
| 31 | M&Lfor 1.25mm thickpressed steel door frame of size 105mm x 60mm with one or more rebates including necessaryfixing lugs , hinges, lock strike plate etc complete all as specified and directed. |
| 32 | S&F Pre- painted coloured trapezoidal profiled Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding towall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed. |
| 33 | S&F Pre- painted coloured plain sheet Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding towall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed. |
| 34 | M&L for 25mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregates)as in flooring to receive to tiles etc completeall as specified and directed. |
| 35 | M&L for 75mm thick PCC 1:3:6 type C2(Using 40mm graded crushed stone aggregate) as in plinth protectionfinishedeven and smoothusing extra cement.Joints to be given at every 3m interval and corners of buildings and fitted with bituminious mastic or equivalent filler complete all as specified and directed. |
| 36 | M&L for 75mm thick PCC 1:3:6 type C2(Using 40mm graded crushed stone aggregate) as in floor/ sub base of floor complete all as specified and directed. |
| 37 | M&L for sheet glass, 4mm thick, ordinary quality and glazing with oil putty in squares n exc. 0.50 Sqm each panecomplete all as specified and directed. |
| 38 | M&Lfor preparation of untreated new wood/wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 39 | M&L for two coats of synthetic enamel paint over one coat of red oxideon new steel surfaces of any description over 10cm in width or girthincluding preparation of surfaces complete all as specified and directed. |
| 40 | M&L for 40mm dia GI pipe Light grade with all necessary fittings laid in trenches, fixed to wall/pole/under road/floor etc for cable protection complete all as specified and as directed. |
| 41 | S&F Bib taps,15mmcast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule or for CPVC pipes complete all as specified and directed. |
| 42 | S&F in repair PVC connectionspipe ,15mm dia size with PTMT nuts of length 450mm complete all as specified and directed. |
| 43 | M&L for Machine cut kota stone slab flooring 20-25mm thick over and including cement screed base 15mm thick in cement mortar 1:6, laid and jointed with grey cement slurrymixed with pigment to match the shade of the slab including rubbing and polishingcomplete all as specified and directed. |
| 44 | M&L for Machine cut kota stone slab as riser, dado, steps, skirting etc 20-25mm thick over and including rendering 10mm thick in cement mortar 1:3, laid and jointed with grey cement slurrymixed with pigment to match the shade of the slab including rubbing and polishingcomplete all as specified and directed. |
| 45 | M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 46 | M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces mixed with water proofing compound and finishing surfaces even and smooth without using extra cement complete all as specified and directed.Note:- WPC will be measured and paid separately under respective item of this schedule. |
| 47 | M&L for preparing newely plastered surface including Chalk whiting, on plastered surfaces,prepara-tory to distemperingof wall and applying finishing walls with acrylic smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and as directed |
| 48 | M&L fornewly plastered surface of wall and appying two coat of white or tinted oil bound distemper over one coat of alkali resistant primer complete all as specified and directed. |
| 49 | S&F medium grade galvanized steel tubing (concealed) with all fittings & fixed complete to walls & ceiling or laid in floors 15 mm dia bore pipe (including in short length) complete all as specified anddirected. |
| 50 | S&Ffancy type, chromium platedstop valve/ angle valvecast copper allow screw down high pressure with crutch or butterfly handle screwed both end form iron pipe or for union and fixed of size 15mm dia complete all as specified and directed. |
| 51 | Cutting existing steeltubing 15mm bore of pipes for alterations oradditions (Each cutmeasured) complete all as specified and directed . |
| 52 | M&L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 1.5 sqmm size through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet coverfor fixing of switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good to disturbed surface complete all as specified and directed for the followings: - |
| 53 | One light point/ Bell/ one fan point controlled by one switch 5 Amps |
| 54 | One 3 pin socket outlet, 6 Amp on the same board with other switches |
| 55 | One 3 pin socket outlet, 6 Amp independent |
| 56 | Supply and fixing 240V, 10KA \"C\" curve single pole miniature circuit breaker (MCB) 6 to 32 Amps,in the MCB DB complete with connection testing and commissioning. complete all as specified and directed. |
| 57 | S&F Switch piano, flush type single pole, one way 6Ampcomplete all as per specified and directed. |
| 58 | S&F Switch piano, flush type single pole, one way 15Ampcomplete all as per specified and directed. |
| 59 | S&FSocketoutlet 2 in 1,3 pin, 6 and 16Amp flush typecomplete all as per specified and directed. |
| 60 | S&F Socket outlet 2 in 1, 5 pin, 6 Ampcomplete all as per specified and directed. |
| 61 | S&F Sheet metal enclosure powder coatedfor MCB DB double door single pole & Neutral 4 way with 200Amp ratedcommon bus bar at incomming complete all as specified and directed. |
| 62 | S&FCeiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 63 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed. |
| 64 | M&L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 10Sqmm 2 core laid in trench/pole/on wall completer all as specified and directed. |
| 65 | M&L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 2.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 2.5 sqmm size through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet coverfor fixing of one 15 Amp switches-sockets outlet independent complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good to disturbed surface complete all as specified and directed. |
| 66 | Supply and fixing240V, 10KA \"C\" curve SPN miniature circuit breaker (MCB) 40 to 63 Amps,in the MCB DB complete with connection testing and commissioning. complete all as specified and directed. |
| 67 | Supply and fixing LED tube light batten box type made of CRCA sheet with decorative end caps suitable with ultra bright glass LED tube light 1x 18/20 watt T8 type single side connection complete with both end bi-pin holder and all accessories internally prewired and fixed to wall/ceiling incl fittings accessories and connecting up with twin core flexible copper conductor cable suitable size complete all as specified and directed. |
| 68 | S&F in replacementlight fitting,1x10W LED bulk head luminaries IP65, Min-50,000 burning Hrs, Diffuser made of high grade polycarbonate, High pressure die cast aluminium housing, CCT-5700K, 240 voltcomplete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V,50HZ. |
| 69 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V,1200 mm sweep, 100% copper wound motor, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Make: Bajaj cat part No. Energos 28 or Turbo 28, Make: Crompton cat part No. Energion Groove and Make : Usha cat part No. Technix BLDC or equivelent make as listed in list of make. |
| 70 | Supply, installation andtesting of electric water heater storage vertical type, BEE 5 star rated, 25 ltr capacity 240 volts 50 Hz comprising of high wattage heating element of 2 KW for instant heating, extra Mild steel with Glass lined coated inner tank, rust & shock proof ABS outer body, non-ferrous pressure plate with & including provn of 04 Nos grouting bolts suitably flushed to wall or any other surface including electric connection with 3 core PVC insulated, sheathed, stranded copper conductor cable/ flexible chord and one No 15 amps 3 pin plug top complete all as specified and as directed. |
| 71 | M&L for earthing complete with galvanised earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground (earth pit not less than 2.25 mtr below normal ground level with top edge of the plate not less than 1.50 mtr below normal ground level connected to galvanised lead lead wire4.0 mm dia by means of bolts, nuts and washers and check nuts of galvanised iron or steel GI earth strip protected by 40 mm medium grade galvanised iron pipe including of 20 mm dia medium grade GI water tubing sheet metal 4mm wire mash funnel, charcoal or coke and common salt in paint and testing on completion all as shown on electrical plate No.3 of SSR Part-I. including taking out unserviceable one and necessary earthwork complete all as specified and directed. |