| 1 | Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed. |
| 2 | M&L brick work with sub class \"B\" old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 3 | M&L for rubber moulded coloured glossy finished cement concrete Chequered tiles of size30 cm x 30 cm x 20mm thick, jointed in neat cement slurry and pointed in white or coloured cement and pigment to match the surface of tile as in path/ hard standing over and including 15mm thick screed bed in Cement mortar (1:4), including demolition of old PCC/ chequerred tiles complete all as specified and directed. |
| 4 | M&L 75 mm thick PCC (1:4:8) type B-2 (Using 40mm graded stone aggregate) as in,sub base laid in panels, finished the top surfaces even and fair without using extra cement complete all as specified and directed. |
| 5 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 6 | M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base of floor complete all as specified and directed by Engr-in-Charge. |
| 7 | M&L for Non skid Endura coloured tiles 8-10mm thick (square/rectangular) grade-4, area of each tile exc 0.06 Sqm but not exc 0.11 Sqm over and including 15mm thick screed bed in Cement mortar (1:6)in flooring, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L Vitrified ceramic tiles of size 10 mm thick Double Charged light shade, area of each tile n.exceeding 0.36 sqmin floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed |
| 9 | M&L Vitrified ceramic tiles of size 10 mm thick Double Charged light shade, area of each tile n.exceeding 0.36 sqm as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10mm thick rendring finished fair an even in cement mortar 1:4 complete all as specified and directed |
| 10 | M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6. |
| 11 | Material and labour for glazed coloured ceramic tiles in vertical surfaces for wall tiles of size 450 x 300 x 7 mm thick as in dados, set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles with joint freeincluding 10mm thick screed bed in cm 1:4. |
| 12 | M&L Granite (of any type) work 20 mm thick (table rubbed and polished)in steps, jambs, pillars, windowcills, cooking platforms and like in over & including 15 mm thick cement mortar (1:4) pointing in white cement (1:2) using marble dust with admixture of pigment to match incl dismantling. |
| 13 | Demolition of cement concrete (Un-reinforced) in any position n.exc 15cm thick (above or below GL) complete all as specified and directed. |
| 14 | M&L for cement concrete 1:3:6 type C2 ,75mm thickusing 40mm graded stone aggregateas in /plinth protectionfinished the top surfaces even and without using extra cement including filing grooves with Grade A compound.complete all as specified and directed by Engineer-in-charge. |
| 15 | Dismantling timber scantlings 40 sq. cm and over in section, in any position for complete all as specified and directed. |
| 16 | Dismantling wrought iron or mild steel work of any description not otherwiseprovided for |
| 17 | S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240complete all as specified and directed. |
| 18 | Preparation of new or previously untreated steel surfaces of any description over 10 cm in width or girth applying two coat of synthetic enamel paint over a coat of red oxide or zinc chrome complete all as specified and directed. |
| 19 | M&L PCC 1:4:8 type D2 (using 40mm graded stone aggregate)as in foundation , filling and mass concrete complete all as specified and directed. |
| 20 | Excavating in post holes (or similar holes) soft/loose soil each n exc0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm complete all as directed. |
| 21 | Dismantling asbestos cement (corrugated, semicorrugated etc) sheets in roof coverings including ridges etc complete all as specified and directed |
| 22 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed |
| 23 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, ridge etc fixed with self tapping screws as specified |
| 24 | Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth, for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc10 sqm on plan and n exc 1.5m in depth and getting out any type of soil complete all as specified and directed... |
| 25 | Returing, filling in any type of soil including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, in any type of soil complete all as specified and directed. |
| 26 | Removing excavated material ( surplus soil) to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specifed and directed. |
| 27 | M&L PCC 1:2:4 type B0(Using 12.5 mm graded aggregate) as in Coping and similar work complete all as specified and as directed. |
| 28 | Taking down cement plaster of any description on brick work or stone masonry walls including rackingout joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 29 | M&L 15mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 30 | M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of wall care putty on walls complete all as specified and directed |
| 31 | M&L 15mm thick rendering cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed. |
| 32 | M&L applying 2 coats of Exterior emulsion Finishing walls with Acrylic Smooth exterior paint of required shade applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm on wall of newplaster surface including cornices, plasters etcall as specified and directed. |
| 33 | M&L applying 2 coats of Exterior emulsion Finishing walls with Acrylic Smooth exterior paint of required shade applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm on wall of oldplaster including complete removal of existing treatmentincluding cornices, plasters etcall as specified and directed. |
| 34 | S&F in repairs PVC water storage tank cylindrical,triple layer vertical with closed top with threaded cover hoisted and fixed in position tank capacity 1000 Ltr with and including ball valve high pressure of PTMT with epoxy coated Aluminum rod and high density plastic ball screwed for 20mm bore of iron pipe and making connection for inlet and outlet including dismantle of old water tank and removing from site complete all as specified and directed. |
| 35 | Taking up or down 20mm dia bore steel/Cpvc tubing and connections including cleaning for re-fixing or removal from site |
| 36 | Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified. |
| 37 | Taking up or down 32 mm dia bore steel tubing and connections including cleaning for refixing or removal from site |
| 38 | Supplying and laying of 32 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified. |
| 39 | S&FCpvc 32 mm outer dia gate valve complete all as specified. |
| 40 | Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size n.exc 1.50 Sqm and removing from site complete all as specified and directed. |
| 41 | All as item No.40 above but exc 1.50 Sqm and n.exc 4.00 Sqm each. |
| 42 | M&L Solid (125mm x63 mm Double Rebate) factory made 100% solid WPC brown door frame made from 100% LEAD FREE (Single extruded process) material with density 780 kg/ Cum & manufactured by an ISO: 9001-2015 certified company, all as per specification drawings as directed by Engg-in-Charge. The door frame should be Water Proof, termite proof, fire retardant and having excellent screw holding capacity and shall be fixed with 6 Nos 150mm long hole fasterners complete all as specified and directed. |
| 43 | M&L Solid (100mm x63 mm single rebate) factory made 100% solid WPC brown door frame made from 100% LEAD FREE (Single extruded process) material with density 780 kg/ Cum & manufactured by an ISO: 9001-2015 certified company, all as per specification drawings as directed by Engg-in-Charge. The door frame should be Water Proof, termite proof, fire retardant and having excellent screw holding capacity nd shall be fixed with 6 Nos 150mm long hole fastners complete all as specified and directed. |
| 44 | M&L 30mm thick moulded plain WPC solid door shutter: providing (30mm thick) MOLDED WPC Brown Factory made 100% solid door (Conforming As per IS: 4020) made from 100% LEAD FREE single extruded with 2,4 or 6 raised panel design on the front side with 10mm deep mould on single side with wood grain texture and back side plain with density not less than 600kg/Cum. Manufactured by an ISO: 9001-2015 certified company. The door should be water Water Proof, termite proof, fire retardant and having excellent screw holding capacity complete all as specified and directed. |
| 45 | Providing and fixing 32mm thick brand factory made wire mesh solid WPC door shutters consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 20mmx40mm for top, lock & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufactures, 20mmx40mm M.S. square tubes shall be covered with 6mm thick heat moulded WPC prelaminated \"C\" channel of size 30mm thickness, 140mm width out of which 125mm shall be flat and 15mm shall be bent in 90 degree on the either side forming stiles & 6mm thick 165mm wide WPC sheet out of which 150mm shall be flat and 15mm shall be bent in 90degree on the inner side to from top & bottom rail and 180mm wide WPC sheet out of which 150mm shall be flat and 15mm shall be bent in 90degree on both side to form lock rail, 12mm (6mm x 2) thick,, 20mm wide cross WPC sheet as gap insert for top rail & bottom rail, Pannel will be of stainless steel, wiremesh of 24 gauge to be fitted in by \"C\" channel of size 32mmx10mm on the either side in the stiles, the inner side \"C\" channel is fixed by 20mm x 40mm MS tube on both sides with screws. The wire mesh in top, bottom & lock rail is sealed with 20mm x 40mm tube wiith stainless steel, wire mesh gauge interior at top, bottom & lock rail. 10mm x 20mm stainless steel pipe griill fix with MS frame for support wire mesh as per selected design an additional 6mm thick WPC strip of 22mm width is to be stuck on the interior side of the C channel using solvent cement adhesive etc, complete all as specified and directed. |
| 46 | Providing & fixing of windows made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 52 x 25mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joinedwith corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy duty stain less steel pivot hinges shall be provided per shutter. The windows should be paneled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 10mm square guard bars with 6” (152.4mm) pitch, complete for finished item of work including of all taxes complete all as specified and directed. |
| 47 | Hacking out old brocken glassof any thickness size quality or description from wooden frame or stone concrete or brick. |
| 48 | S & F sheet glass 4mm thick for windowordinary quality in n.exc 0.75 Sqm in each pane with rubber beading as in doors and partition. |
| 49 | Dismantling of wallandceilingboards(fibre, pulp, insulation etc) or insulationboards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed |
| 50 | S&F Non asbestos fibre cement building boards 4mm thick fixed or laid/ inserted totimber/GI/Aluminium frame work with screws 10 mm thick in aluminium snap grid frame work for false ceiling and hanging with6mm dia GI (upto the 1200 mm length )adjusting level fixed to roof slab by means of ceiling cleats made out of GI flate 40X3mm size 60mm long and expansion hold fasteners 12.50mm dia.40mm dia long complete all as specified and directed |
| 51 | S & F in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with stainless steel wire staples/xpm and fix by weld to steel windows |
| 52 | M&L for preapration of old concrete surface or unplastered surafces on wall withtwo coats of oil bound distemper on wall surfaces over a coat of putty complete all as specified and directed by Engr-in-Charge. |
| 53 | M&L for preparing old steel and iron surfaces of any description over 10 CM width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge. |
| 54 | S&F in repair PVC hollow section heavy grade designer wall panelling 5.5-6mm thick as approved by Engg-in-charge fixed in position including all matching beading, angle for jambs, cills etc complete all as specified and directed. |
| 55 | M&L for preparation of old surfaces on walls including brooming down or steel wire brushing scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white wash on old decorated surfaces complete all as specified and directed by Engr-in-Charge |
| 56 | Disconnecting the electrification and taking down DBs (any type of SPN DBs) andmaking good to the disturbed surfaces to match the existing surface all as specified and as directed by EIC.Note - Temporary power supply shall be provided by contractor. |
| 57 | Taking down U/S submainwiring aluminiumetc and making good the disturbed surfaces of walls/ floor etc matching with the existing surface. |
| 58 | M&L for sub-main wiring (concealed) with two single core 6 sq mm FRLSH PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of massinory including 25 mm dia non-metallic PVC conduit fixed in wall including 6 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by EIC. |
| 59 | M&L for sub-main wiring (concealed) with two single core 4 sq mm FRLSH PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of massinory including 20 mm dia non-metallic PVC conduit fixed in wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by EIC. |
| 60 | Taking down carefully aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pedants, regulators, sockets, light fitting etc.. and making good the disturbed surfaces of walls/ floor etc matching with the existing surface all as specified and as directed by EIC. |
| 61 | Material & Labour for following type Point Wiring controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and includingconcealedPVC conduitMMS ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia(Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates). |
| 62 | One light point controlled by one switch. |
| 63 | One ceiling fan pointcontrolled by one switch. |
| 64 | One exhaust fan pointcontrolled by one switch. |
| 65 | One 3 pin socket outlet 5 Amps on the same board. |
| 66 | One 3 pin socket out let 5 Amps on the independent board. |
| 67 | All as per Item No.61 above but 2.5 Sq mm multi stranded copper conductor with 2.5 Sq mm copper earth continuity wire connected to earth duly complete for one 15A Socket on Independent board all as specified and as directed by EIC. |
| 68 | Supply and fixing surface & wall mountedLED batten 4 feet with 1x20 Watt indoor box type poly carbonate decorative luminaries ,PF O.9 and above operating voltage 140V-270V,Colour temp 6500K & lumen input output 95 Lumen per watt and including electronic driver and 1x20 watt LED Lamp,, pre-wired including necessary electric connection with copper flexible PVC cable of 0.50 Sq mm 3 core not more than 1 mtr in length from ceiling rose/connector to light fitting, |
| 69 | S & F anglelamp holder, PVC Polycab type with back plate suitable for batten fittings complete including fixing of 9/10 watt LED bulb all as specified. |
| 70 | Supply and fixingstep socket type modular fan regulator 120/280 V , 100Watt all as specified and as directed. |
| 71 | Supply and fixing modular socket, 6A -2/3 pin combined 2 module ISI marked 230 volts, 50 Hz all as specified and directed by Engr- in-charge. |
| 72 | S & F Switch Modular single pole, one way 6 Amps, 1 module 240 Volts AC all as specified and directed by Engr- in-charge. |
| 73 | Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts 50 hz all as specified and directed by Engr- in-charge. |
| 74 | Supply and fixing switch modular , one-way 16Amps,1 module 240 Volts AC all as specified and directed by Engr- in-charge. |
| 75 | M & L for ceiling rose, surface bakelite, 65 x 50 mm, three terminals all as specified and as directed. |
| 76 | S & F sheet metal enclosures for SPN DB\"s with double glazed door for incorporating MCBs,IP-43 , 8 way with 200 amps rated busbar, 240 volts, as per IS-8623 all as specified and as directed. |
| 77 | S & F MCBs SPN 32 amps, 240 volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs all as specified and as directed by Engr-in-Charge. |
| 78 | S & F MCB SP, 6 to 32Amps,240 volts, 50 Hz, \"C\" curveincluding necessary incoming and out going electric connection with suitable size of copper lugs all as specified and as directed by Engr-in-Charge. |
| 79 | S & F MCBs SP 40amps, 240 volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs all as specified and as directed by Engr-in-Charge. |
| 80 | S&F DB Power unit MCB protected socket with sheet steel enclosure 20 Amp combo incl 16 amp plug top indicator type for A/C or Geyser |
| 81 | M & L for Earthing complete with galvanised steel pipe electrode, 600 x 600 x 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to galvanised earthing lead of 4 mm dia of iron or steel wire all as shown in electrical plate No. 5 all as specified and as directed.Note :- the cost of excavation and earth work PCC pit and CI cover funnel & watering pipe, wiremesh, charcoal dust and common salt shall be deemed included in the unit rate for earthing all as specified and as directed by EIC. |
| 82 | Supply, fabricated and and fixing of street light bracket made out of GI pipe 1.0 Mtr long, 32mm dia medium grade bent to shape as directed including clamps made out of 40 mm x 6 mm flat for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide/primer all as specified and as directed. |
| 83 | M & L for LED Bldg Security light Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 84 | M & L for disconnecting electric supply, taking down old unser fan, cealing cable ends, dismantling blades carefully after unscrewing nuts and bolts of ceiling fan any size from existing position and bringing to AGE E/M store yard |
| 85 | S& F Ceiling fan complete with copper winding,blades ,down rodss,electronic regulastor and accessories 230 v0lt,1200mm sweep,min delivery 210 CFM wuth service value 6.00 BEE. Five star rated with BLDC |
| 86 | Supply and fix exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230 volts, 50 Hz, 1200 RPM, copper winding of sweep 250 mm complete and taking out old u/s geyser with deposited to E/M Store yard at AGE E/M Store yard all as specified & as directed |
| 87 | Supply and fixing LED luminaire 600 mm x 600 mm, 40 watts, 220 Volts, AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size compete including taking dwon old UNSV light fitting all as specified. |
| 88 | S & F decorative type Glanze Wall light inclding 7/9 watt LED (B22)with all necessary fittings complete all as specifed and directed. |
| 89 | S&F Oval shape Bulk head Edge -lit LED fitting comprising with high brightness LED 10 WATT,IP-67 protection all as directed. |
| 90 | Supply and fixing elect water heater storage type ABS body with glass lined inner tank with digital temprature indicator and heatingelement upto 2 KWcapacity 25 litre, BEE 5 star rated completewith all accessories such as safety valve thermostate NRV connection piece etc complete and taking out old u/s geyser with deposited to E/M Store yard at AGE E/M Store yard all as specified & as directed. |
| 91 | Supply & fixing Exhaust fan , Steel body, Metallic gray, AC single phase ,230 Volt of size 300sweep,1400 RPM ,1710 CMH.90 W and Above with blades,frame and louvers and taking out old u/s geyser with deposited to E/M Store yard at AGE E/M Store yard all as specified & as directed. |
| 92 | M & L for 40mm bore GI pipe (med grade) laid or fixed with wall for hanging of ceiling fan of 1200 mm sweep including necessary PCC work andMS clamp 02 Nos on each span of not more than 10 meter horizontally suitable for ceiling fancomplete all as specified and directed. |
| 93 | S& F MCCB,4 Pole ,16 KA,100 AMP,415 v |
| 94 | S & Fvertical load line in sheet metal enclosures MCCB TPN DB\"s with double door for incorporating MCCB as incomer and MCBs SP/SPN as outgooing , IP-43 , TPN 4 way with 200 amps rated busbar, 440 volts, as per IS-8623 including taking out old UNSV DB and making good the disturbed surface of wall and match with the existing surface compelte all as specified and as directed. ( Note- MCCB 3 pole 63 amps as main incomer will be included in quoted rate) |
| 95 | NOTES :-1.For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed. |