| 1 | Comprehensive Maintenance of Lifts including daily check and periodical services of fully automatic electrical Lift with, Renewing all wire ropes and chains (where fitted) as often as required to maintain an adequate factor of safety, to equalize the tension on all hoisting ropes, repair or replacing conductor cables and hoist way and machine room elevator wing, Systematically examining and adjusting the mechanism worm gear, thrust bearing, drive sheave, drive sheave bearing, break contact, lining and components, motor, motor generator, motor winding, rotating elements, commutator, brushes, brush holders, bearings, coils, Resistance for operating and motor circuits, magnet frames and other mechanical parts.Systematically examining and adjusting the mechanism worm gear, thrust bearing, drive sheave, drive sheave bearing, brake contact, lining and components, motor, motor generator, motor winding, rotating elements, commutator, brushes, brush holders, bearings, coils, Resistance for operating and motor circuits, magnet frames and other mechanical parts. Systematically examinining the controller, selector, leveling devices, cams, relays, solid state components e.g PCBs, transducers, resistors, condensors, power amplifiers, transformers, contacts, leads, dashpots, timing devices, steel selector tapes and mechanical and electrical driving equipment, governor, governor sheave, shaft assembly, bearings, contacts and governor jaws, Repair to car and hall mechanical buttons, car and hall position indicators, hall lanterns, car direction indicators and all other car and landing signal fixtures as installed by OTIS/ Thyssenkrupp. Repair/Servicing of deflector or secondary sheave, bearings, car and counterweight guide rail and buffers, top and bottom limit switches, governor tension sheave assembly, compensating sheave assembly, car, counterweight, and counterweight guide shoes including roller or grib. Examining and repair to interlocks on hoist door, hoist way door hangers, guides, automatic power operated door operated operator, car door hanger, car door contact, safety shoes, load weighing equipment, car frame, car safety mechanism and platform. |
| 2 | 08 Ps Lift (544 Kg) (G+14 Storey) in Building R-27, R-30, R-31, R-34 & R-35 (OTIS) (Total 05 Nos Lifts) |
| 3 | 13 Ps Lift (884Kg) (G+14 Storey) in Buildings R-14, R-17 & R-34 (OTIS) Total 03 Nos of Lifts |
| 4 | 08 Ps Lift ( 544 Kgs)(G+6 Storey) in building F1 & G Block (OTIS) Total 02 Nos of Lift |
| 5 | 13 Ps Lift (884Kg) (G+6 Storey) in Buildings F1 & G Block (OTIS) Total 02 Nos of Lifts |
| 6 | 06 PS /8PS (544kg) capacity installed in Bldg No R-19,R-21,NKG,R-27, R-32,R-33, NKG, Tula ,R-39 (A & B Wing) (Total 10) lifts |
| 7 | 13 PS (884KG) Capacity lift (G+14)installed in Bldg No NKG and R-32 (Total 02 No ) lifts |
| 8 | Repair/maintenance of lifts including carrying out daily check and periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes,door cards,car door sills, landing door sills, door locks, control cards, and its contacts, hall push buttons and its spares, connector/links, welding of cracked/broken and MS parts, Landing operating Panel of any size and capacity, repairs /maint of unserviceable damageddoor safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator,and all connected accessories, necessary wiring of hall push button assembly, repair/maintenance of broken COP/LOP buttons and display, including cover, Fire alarm, Firemen button glass, Intercom, alarm/hooters, Maintenance of damagedhand rail, Shaft, light/switches, complete with illuminated push button and direction indicator with LED display with LPT/LPC cardof stainless steel inclusive of harness wiring for laminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement for safe operation of lifts , fixing of loose rail bracket with necessary masonry work ,cabin, minor repair of cabin light, shaft light and minor repair of cabin fan , ensuring safe and smooth functioning of liftand complete maintenance of car top, binding of loose wire at control panel and rust painting at car top and door and allied parts with testing, two coats of Painting ofGear motor, all MS channels and Control panels using spray gun complete, dewatering of lift wells in case any emergency arises allas directed by Engineer-in-Charge. for the following lifts :-Note : -(i) Two mechanic shall be available round the clock at lift complaintcell for safe & smooth functioning of the lift and to carry-out rescue operation. (ii)Rewinding of motor if required will be done by the contractor and no extra cost will be given by the department. (iii) The detailed duty mechanics of the firm shall report to the JE Concerned at the Lift complaint cell i.e. R-12 building . New Navy Nagar for receiving the complaints at round the clock daily including sunday and holiday.(iv) The detailed lift mechanics shall sign ( Their shift wise) in the attendence register kept with lift cell. |
| 9 | 08 Ps Lift (544 Kg) (G+14 Storey) in Building R-18(Thyssenkrupp) (Total 01 No Lifts) |
| 10 | 13 Ps Lift (884Kg) (G+14 Storey) in Buildings R-15, R-26 ,R-30, R-33,R-35 (Thyssenkrupp) Total (05 Nos of Lifts ) |
| 11 | 29 Ps Lift ( 2000 Kgs) ( G + 14 Storey) in Buildings R-28, R-29, R-30, R-31, R-32, R-33,R-34, R-35(Total 08 Nos Lift ) |
| 12 | 08 Ps lift (544 Kgs) ( G+6/ 14 Storey) in bldg R-12, (Thyssenkrupp),( Total - 01 Lift) |
| 13 | 13 Ps Lift ( 884 Kg) (G+ 6/14 storey) in NKG ,R-9,R-10,R-15,R-16,R-20,R-21,R-24&R-27 bldg, R- 39 E & E Wing ( Thyssenkrupp) ( Total- 10 Nos lift) |
| 14 | Goods lift ( 2000 Kg)(G+14 Storey) in bldg R-16, R-20 & R-21 ( Total 03 Nos Lift) |
| 15 | 13 Ps Lift (884Kg) (G+06 Storey) in Buildings R-36, R-37 and R-38 (Thyssenkrupp) Total (06 Nos of Lifts ) |
| 16 | Notes for item Nos 1.00 to 2.07 : - (i) The Contractor has to carry out the AMC of the Lifts through OEM (OTIS) only for which he will enter an agreement with OEM(ii) The AMC should cover any/all parts of Lifts if its fucntions found defective the same should be repaired or replaced by the OEM as per the timeline covered under norms. (iii) Two mechanic shall be available round the clock at lift complaintcell for safe & smooth functioning of the lift and to carry-out rescue operation. (iv)Rewinding of motor if required will be done by the contractor and no extra cost will be given by the department. (v) The detailed duty mechanics of the firm shall report to the JE Concerned at the Lift complaint cell i.e. R-12 building . New Navy Nagar for receiving the complaints at round the clock daily including sunday and holiday.(vi) The detailed lift mechanics shall sign ( Their shift wise) in the attendence register kept with lift cell. |
| 17 | Supply and fixing in repairs new cabin fan, non-oscillating type, axial flow, single speed 300mm sweep, 240 volts ISI marked with grill complete all as directed by Engineer-in-Charge. |
| 18 | Taking down old unserviceable main steel wire rope after disconnecting old wire rope from counter weight, pulley and car cabin and supply and fixing new main steel wire rope 13 mm dia, ungalvanised, 8/19 construction in and including necessary connection with counter weight, pulley and car cabin with clamps,nut, bolts and washers etc complete all as directed by Engineer-in-Charge.in 8/13 /GoodsLift, G+14 Storey buildings. |
| 19 | Disconnecting and taking out old/unserviceable Governer rope of size 8 mm dia(8/19 Construction) ungalvanised including necessery connection with pully in machine room and shaft pit complete with clamps, nuts bolts, and washers etc, for high rise building for 8/13/Goods lifts |
| 20 | Dismantling and taking out unserviceable safety edge of anytype & supply and fixing new full beam infrared sensor upto full length of car doors (2.00 mtr) as specified and directed by the Engineer-in-Charge. |
| 21 | Supply & fixing in repairs automatic door drive unitwith VVVF of 1 HP capaicity all as specified anddirected by Engineer-in-Charge. |
| 22 | Supply and fixing in repairs hooter with emergency call announciator working on 12 Volts with audibility 90DB @ 100M distancewith complete accessoriesand alongwith box including connecting cables |
| 23 | Supply and fixing in repairs UPS Sua3000l3000Va alongwith necessesary wiring with machine and controller for smooth functioning of ARD system of 08/13 ps lift. |
| 24 | Supply and fixing in repairs UPS Sua6000l6000Va alongwith necessesary wiring with machine and controller for smooth functioning of ARD system of 29 ps lift. |
| 25 | Supply and fixing in repairs CEGARD MINI w/Y Cable harness along with control box in full height( 2.00 Mtr) as specified and directed by Engineer-in-Charge. |
| 26 | Supply and fixing in repairs new full collective hall button fixtures with call registration light combined with Digital floor position indicator and Up/Down directional arrows at all floors with SS face plate all as specified and directed by Engineer-in-Charge |
| 27 | Supply and fixing in rep[airs Aluminimum Chequred plate of 5mm thick duly fixed with nuts, bolts, washers,screws and covers with aluminimum angles section of size ( 40x40x4 mm thick) on corner of cabin in and including plateform base of 10mm thick plywood of 08/13 Ps lifts |
| 28 | Dismantling and taking out unserviceable old control panel and control wiring and supply and fixing new CAN BAS Integrated Drive based collective control panel in hinged MS powder coated cabinet with control wiring comprising with multiple microcontrolled programmed chip based controlled by pulse modulation, complete with all safties such as thermal overload protection, over current protection, auto phase reverse link to each other in net work and compitable to 18 KW/24HP capacity VVVF drive including proper connection with proper lugs, terminal connectors screws and motor connection with galvanised sheet trunking 24 SWG including wiring of main motor with suitable size of stranded copper cable etc complete all as specified and directed by Engineer-in-Charge. |
| 29 | Disconnecting and taking out old/unserviceable shaft wiring, supply and fixing of shaft wiring in hoist way upto lower limit with PVC insulated copper conductor cable single core, 1100 Volts grade 0.75 Sqmm 24 Nos single core & 1.0 Sqmm for earth wire duly bunched with wire binding locking strip, drawing through in and including galvanished sheet metal trucking of 24 SWG up to ground floor in hoist for control to all function including in built connection for control panel, PCB, Hall push button, fire switch and lower limit switch all as specified and directed by the Engineer-in-Charge. for G+14 Storey building. |
| 30 | Disconnecting and taking out defective unserviceable main drive (any type) from existing control panel and supply and fixing CAN BAS Integrtaed drive suitable for 13 Ps lift G+14 storey building complete with all electric connection. |
| 31 | Disconnecting and taking out defective dynamic breaking resistance from controller and supply and fixing new aluminium covered wire wound dynamic breaking resistor to absorb the reverse energy dissipation of motor during regeneration in control operation suitable for 11.0KW/15HP motor. |
| 32 | Taking down old unserviceable Announcement system and supply and install, testing and commissioning of MP3 voice announcement system in the controller and high quality speaker on car top, with necessery provision of shaft wires and travelling cable complete as specified. The audio indicator shall anounce floor position, ARD made operation, overload announcement etc and continious mild music in hindi and can be programmable for more music. The announcement system shall be in hindi and english. |
| 33 | Replacement of unserviceable ARD control system and commissioning and testing of newARD system suitable for upto 15 KW motor including wiring with connected items in existing G+14 Storey building Goods lifts 415V,50 Hz,3 phase with a speed of 1.2 m/sec comprising with maintenance free battery 12 V, 26 AH (06 Nos five year Maintenance free battery, (Make Exide/Amaron) to match with the existing capacity motor and controller systemcomplete all as specified and directed by Engineer-in-Charge. |