| Sl. No. | Item Description |
| 1 | Providing consultancy service for preparation of structural drawing using structural design software based on the soil investigation report provided by AAI, Preparation of architectural and services drawing using BIM software based 3 D modelling, Architectural and structural design and preparation of detailed structural drawingfor proposed Deck/Mezzanine floor, composite structure (Steel & RCC) and associated structures / Facilities (Washroom, F&B outlets, Baby care room, Electrical, Airport Systems and IT service based on data supplied by respective departments etc) inside Arrival Building at Coimbatore International Airport as directed by the Engineer-in-charge.(i)Preparation and submission of Structiral Design Drawing based on the soil investigation report provided by AAI, Architectural drawing BIM software based 3 D modelling , including structural design, designing of electrical and mechanical systems and preparation of drawings , The BIM software based drawing should include ,Internal partitions, flooring ,false ceiling, lighting, air conditioning, cable ducts, cable trays, data cables ,water supply, Power supply ,sewage, drainage, cabling, hydrant based fire fighting system, gas based fire suppression system and any other services etc for proposed Deck/Mezzanine floor, composite structure (Steel & RCC) and associated structures / Facilities (Washroom, F&B outlets, Baby care room etc), meeting the requirements of civil , electrical and CNS/IT/Airport Systems list of works issued by CNS/IT/Airport System directorate .(ii)Preparation and submission of structural design and drawing for proposed Deck/Mezzanine floor, composite structure (Steel & RCC) and associated structures / Facilities (Washroom, F&B outlets, Baby care room etc),The detailed structural design and structural drawings etc. should be submitted in soft copy as well as three sets in hard copy etc.after obtaining vetting of the reports and design from reputed government Engineering institutes like, IIT, NIT or government Engineering college complete as per the direction of engineer in charge.(iii)The BIM based services drawing prepared based on the inputs from Civil, Electrical, CNS, IT and Airport Systems, for which separate agencies are deployed by respective departments should be prepared and submitted as a soft copy as well as six sets in hard copy.(iv)Revision of BIM based services drawing should be done if necessitated during the progress of the work.(v)As built drwing should be prepared and submitted after completion of all sub packageslike Electrical, Airport Systems, CNS etc. execuited by other departments.(Note: - Please read the technical specifications of the item before quoting). |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns. |
| 7 | Providing and fixing up to floor five level precast cement concrete solid block including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : 1:1½:3 (1 Cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbels etc., including edges |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 12 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V levelConcrete of M35 grade with minimum cement content of 370 kg /cum |
| 13 | Providing and laying autoclaved aerated Concrete (AAC) blocks masonry with 100mm / 125 mm thick with Grade 1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. |
| 14 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 15 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm |
| 16 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 17 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete |
| 18 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 19 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood |
| 20 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 21 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete :125x65x2.12 mm |
| 22 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :250x10 mm |
| 23 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125mm |
| 24 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 25 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embosse on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete |
| 26 | Providing and fixing partition upto ceiling height consisting of G.l. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.l. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture\"s specification and direction of engineer in charge all complete.: 75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks) |
| 27 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 28 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete. |
| 29 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 30 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. |
| 31 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm |
| 32 | Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS: 15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.30 kg / sqm including grouting the joints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only. Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. Size of tile 800x2400mm of all colours and shades |
| 33 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red |
| 34 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.63 mm thick with zinc coating not less than 275 gm/m* |
| 35 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness60 microns (minimum), including factory painted after bending and perforation and backed with a black Glass fiber acoustical fleece. |
| 36 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main ’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x 28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size (24x24x3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening “for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. |
| 37 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 38 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee without door 110x110x110 mm |
| 39 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° 110 mm bend |
| 40 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain) 110 mm Shoe |
| 41 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 42 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board. |
| 43 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 44 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) |
| 45 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 46 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 47 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats. |
| 48 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. |
| 49 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspectionof work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment shall be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 50 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 51 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 52 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 53 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 54 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead |
| 55 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 56 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 57 | Providing and fixing soil, waste and vent pipes :100 mm dia. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
| 58 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia. Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 59 | Providing and fixing plain bend of required degree. 100 mm dia. Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 60 | Providing and fixing single equal plain junction of required degree : 100x100x100 mm Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 61 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 62 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes |
| 63 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes |
| 64 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal outer dia Pipes |
| 65 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes |
| 66 | Providing and fixing uplasticised PVC connection pipe with brass unions :30 cm length 15mm nominal bore |
| 67 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 68 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 69 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 70 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 71 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 72 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). |
| 73 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 74 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. |
| 75 | Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3 mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs.(Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately). |
| 76 | Fabrication and manufacturing of solid precast concrete element with provisions of shear keys, connecting loops, dowel tubes and propoer lifting accessories for walls, beams, slabs, stairs, column etc, of various thickness, shape and size of different concrete grades manufactured in controlled factory enviornment with approved methodology including moulds (Pallet Systems, Tilts form, Table moulds, Battery Moulds, Vertical Moulds, Beam Moulds, Column Moulds, Staircase Moulds, Facade Moulds, etc) mixing, transporting and placing of concrete, vibrating, curing, finishing, making necessary cutout/holes of required sizes for services, yard handling and stacking all complete as per IS 11447:1985 and as per apporved shop drawings and desing Mix as per the direction of Engineer-in-charge.(Cost of reinforcement, Mechanical, Electrical and Plumbing insert will be paid separately).Concrete Grade M35 (cement content of 370 kgs)Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 77 | Transportation of Precast Elements by flat bed Trailor (Double/Triple axle 40ft Length with proper accessories like A frame etc) from factory, including the cost of loading, unloading and stacking at site (respective erection location) with the help of required capacity cranes.:Lead witjin 15 km. |
| 78 | Erection and installation of Precast/Pre-stressed Concrete elemnts in correct and final position with proper line level and plumb at site making all arrangements. (i.e. Cranes, Push-Pull jacks and all another T & P for lifting placing and allignment of elements, within erection tolerance as per IS 15916 as per approved shop drawings and all complete as per the direction of Engineer-in-charge but excluding the cost of sim pads, non shrink grout and steel works i.e. hangers. All work up to fifth floor. :Solid concrete elements. |
| 79 | Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 80x40x3.2mm and32x32x3.2mm hollow MS tube posts/horizontal members/bracings covered with Plastic/vinyl digitalprinted banner sheet(deign to be printed wii le decided during work by E-I-C) . The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m.Suitable arrangement of interlockingshall be made to fix the barricading to avoid from overturning. The work shall be executed as per drawing/ direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge.(Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). |
| 80 | Finishing with Polyurethane enamel paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 81 | Providing and fixingwall mount type water closet (European Type) of make \"JAGUAR\" (Code VGS-WHT-81953UF) or equivalent with seat cover all complete as per the directions of EIC |
| 82 | Providing and fixing white vitreous urinal of approved make of JAGUAR (code URS-WHT-13253N) or equivalent with fittings, clamps all complete including cutting and making good the wall and floor wherever required etc complete as per the dirctions of the Engineer-in-charge.(Without sensors) |
| 83 | Providing and fixingCounter top wash basin of approved make of JAGUAR (FLS-WHT-5931), brass pillar taps of make JAGUAR (code PRS-CHR-031), 32 mm C.P. brass waste (code ALD-CHR-705), of standard pattern of approved make likeJAGUAR or equivalent of white colour including cuttingwherever required etc complete as per the dirctions of the Engineer-in-charge. |
| 84 | Providing and fixing SS Bottle trap of made \"JAGUAR\" (code ALD-CHR-769L250X190) or equivalent all complete as per the directions of EIC. |
| 85 | Providing and fixingC.P brass health faucet of make \"JAGUAR\" (Code ALD-CHR-577)or equivalent, all with 1m flexible hose complete as per the direction of EIC. |
| 86 | Providing and fixing C.P brass two way bib cock ofmake \"JAGUAR\" (code LYR-CHR-39041)or equivalent, -15 mm Nominal bore complete as per the direction of EIC. |
| 87 | Providing and fixing C.P brass angle valve of make \"JAGUAR\" (code ARI-CHR-39053)or equivalent, complete as per the directions of EIC. |
| 88 | Providing and fixing C.P brass toilet paper holder ofmake\"JAGUAR\" (code ACN-CHR-1153N)or equivalent, complete as per the direction of EIC. |
| 89 | Providing and fixing C.P brass bath grip of make \"JAGUAR\" (code ACN-CHR-1101S) complete as per the directions of EIC. |
| 90 | Providing and fixing of urinal sensors ofmake \"JAGUAR\" (Code SNR-CHR-51083)or equivalent, as per the directions of the engineer-in-charge. |
| 91 | Providing and fixinginwall tank (European Type) ofmake \"JAGUAR\" (code Jaquar JCS-WHT-2400S/ JCP-CHR-392415) or equivalent, all complete as per the directions of EIC |
| 92 | Providing and fixing \"JAGUAR\" make flush cover (Code: JCP-CHR-392415) CP Bevel in wall tank face plate to the existing \"JAGUAR\" make water closet (European Type) with necessary fittings complete as per the direction of EIC. |
| 93 | Providing and fixing of soap dispenscers of make \"JAGUAR\" (Code: ACN-CHR-1137N) as per the directions of EIC |
| 94 | Providing and fixing modular toilet cubicles of Titan Box-up Series Cubicles MERINO-BESCO or Green lam Classic series or approved equivalent make and shade, as per manufacturer\"s standard specifications. All intermediate panels, pilasters, doors shall be made up of 12mm thick Solid Compact Laminate (Phenolic Core Board) as per IS 2046 based on thermosetting resins, homogeneously reinforced with cellulose fibres making cubicles impervious to Water, resistant to Fire, etc. Hardware and Fixing All accessories shall be of 304 grade including all hardware/fittings. The pilaster are anchored to the flooring using adjustable SS legs. The SS SQUARE top rail shall be fixed on the top of the pilasters Accessories Std accessories include SS Hinges, SS Door knob, SS thumb turn indicator, SS coat hook, SS SQUARE top rail and SS channels (All accessories in SS 304 grade) SS legs in SS 316 Grade.: Std Sizes (W x D x H)- 1000 mm to 1200 mm x 1550 mm x 2100 mm, ( Height is including 130 mm gap from bottom) Door Size- 600-610 x 1925 mm. (As per manufacturer’s specifications) For payment purposes one side surface area of partitions including SS leg shall be measured. |
| 95 | Providing and fixing urinal partitions of standard dimensions of approved shape of Merino (Besco)/ Greenlam Sturdo or approved equivalent make and shade, made of 12 mm thick compact laminated phenolic Core Board based on thermosetting resins, homogenously reinforced with cellulose fibre and laminated on both side with suede finish, scratch & impact resistant. The urinal partitions shall be fixed on walls with right angle brackets in stainless steel of grade 304 with necessary stainless steel screws of grade 304 complete as per the direction of Engineer in charge. Urinal partition of size 1200 mm x 500mm.(As per Manufacturer’s Specifications) |
| 96 | ELECTRICAL WORKSSITC of Indoor 11KV, 630A VCB panel at existing HT panel room, internal arc withstand current rating 26.3 kA for 1 secconfirm to IEC 62271-200, closed door rack-in and rack-out of circuit breaker, floor rolling type. |
| 97 | SITC of outdoor 250KVA OLTC type transformer Aoil-type, three-phase design, DY 11,11 kV primary voltage440 Vsecondary voltage frequency of 50-60 Hz, and an on-load tap changer (OLTC) for voltage regulation on the primary side. It is oil-cooled, built for industrial use, and should have a specified temperature rise, insulation class, and core material. |
| 98 | Supply and Laying of HT cable from HT panel to Transformer. 3x300 sqmm HT cable shall be stranded compacted circular Al conductor, conductor screen with extruded semi conducting compound, XLPE insulated inner sheath of PVC, galvanised steel flat strip armoured confirming to IS 7098 part-II 2011 with uptodate amendments. |
| 99 | Supply and laying of XLPE Ar. AL LT cable in trench, tray or on surface . Laying to be done as per the CPWD standards. A) 3.5x300 sqmm (from Transformer & DG set to panel) and (from Power house & Switch room -1) |
| 100 | Supply, installation, testing and commissioning of a factory-fabricated, floor-mounted, compartmentalised, sheet-steel LT Power Control Panel suitable for 415 V, 3-phase, 4-wire, 50 Hz system, fabricated from minimum 2.0 mm CRCA sheet, dust and vermin-proof, powder-coated, IP54/IP55 protected, with front-operated doors, cable alley, removable bottom gland plate, lifting hooks, internal partitioning, and complete with all accessories. Panel shall be of a CPRI type-tested design and comply with IEC 61439 and relevant IS standards.Panel shall include electrolytic grade copper busbars of suitable size, 3½/4-pole, colour-coded, with heat-shrink sleeves, supported on SMC/DMC supports, having short-circuit withstand rating not less than __ kA for 1 second; and full length copper earth busbar with proper earth terminals.The panel shall consist of the following:Four Nos. Incomer MCCBs of 400 A, 4-pole, microprocessor/electronic release, suitable breaking capacity, with spreader links, padlocking, mechanical interlocks, and indication:• 2 Nos. for Transformer incomers – configured as one working + one standby• 2 Nos. for DG incomers – configured as one working + one standbyAMF / Auto Changeover arrangement providing automatic selection between Transformer mains supply and DG supply with necessary relays, timers, AMF controller, selector switches (Auto/Manual/Test), R/Y/B healthy indications, DG Start/Stop logic, transformer working/standby logic, DG working/standby logic, interlocks, wiring and synchronised changeover as per approved scheme.Ten Nos. outgoing feeders comprising:• 5 Nos. 250 A, 4-pole MCCBs• 5 Nos. 100 A, 4-pole MCCBsMetering & indications including digital multifunction meters (on working incomers), CTs of suitable class, R/Y/B indication lamps, ON/TRIP indications, Auto-Manual lamps, selector switches, mimic labels, control fuses, and control transformer (if required).Internal power and control wiring using FRLS PVC insulated copper wires, ferrule-marked at both ends, neatly bunched with ties, with suitable terminal blocks.Engraved nameplates, feeder designation labels, panel schedule, danger boards and all required accessories. |
| 101 | Supply, installation, testing and commissioning of a floor-mounted, sheet-steel Commercial LT Panel suitable for 415 V, 3-phase, 4-wire system, fabricated from minimum 2.0 mm CRCA sheet, powder-coated, IP54/IP55, with cable alley, gland plates, copper earth bus, internal wiring and all necessary accessories. Panel shall comply with IEC 61439 and be based on a CPRI-type-tested design.Panel shall have suitably rated copper busbars with required short-circuit withstand capacity, supported on SMC/DMC insulators and fully insulated at joints.Incomers (All 250 A MCCBs):2 Nos. 250 A, 4-pole MCCBs – Essential Panel incomers2 Nos. 250 A, 4-pole MCCBs – EB incomersAutomatic Changeover (EB Priority):A fully automatic changeover scheme shall be provided with EB as preferred source, shifting to Essential/DG incomer on EB failure and automatically returning to EB on restoration. Includes AMF/ATC controller/relays, Auto-Manual switch, R/Y/B phase-healthy indication, interlocking to prevent paralleling of sources, status indication lamps and complete control wiring.Outgoing Feeders:5 Nos. 100 A, 4-pole MCCBs with required termination and indication.Includes FRLS internal wiring with ferrules, nameplates, feeder labels, routine tests (IR, HV, functional/interlock tests), submission of SLD/GA drawings and complete commissioning including positioning, alignment and proving of the changeover sequence. |
| 102 | Supply, installation , testing and commissioning of 250 kVA, 3Phase, 415V AC, Silent DG Set comprising of Engine , with minimum 310 BHP, at 1500 RPM, coupled with alternator of same make mounted on a common base frame complete witha) AMF control panelb) Fuel tankc) Battery & leadsd) Silencer – Residentiale) AVM padsf) First Fill of lube oilg) Acoustic enclosureh) Aluminium Power cable ( upto 60 mtr)j) Transportation upto Sitek) Commissioning |
| 103 | Internal and External ElectrificationProviding and laying 1.6 MM thick Hot deep - galvanizedGI factory fabricated raceways in partition of the following sizes including providing removable 2 mm thick GI cover knock out holes and fixing accessories earthingcompleterequired including floor/wall/ceiling supports, bends, access boxes and tap off boxes as per specification and cross over as per site requirement. The thickness of raceway & cover shall be as per technical specification. (For electrical wiring).Raceway shall include arrangement for crossing through expansion joints as per Technical Specification / Drawings . 50 mm wide x 38 mm deep. (1 Compartment) |
| 104 | Providing and laying 1.6 MM thick Hot deep - galvanizedGI factory fabricated raceways in partition of the following sizes including providing removable 2 mm thick GI cover knock out holes and fixing accessories earthingcompleterequired including floor/wall/ceiling supports, bends, access boxes and tap off boxes as per specification and cross over as per site requirement. The thickness of raceway & cover shall be as per technical specification. (For electrical wiring).Raceway shall include arrangement for crossing through expansion joints as per Technical Specification / Drawings . 100 mm wide x 38 mm deep. (1 Compartment) |
| 105 | Providing and laying 1.6 MM thick Hot deep - galvanizedGI factory fabricated raceways in partition of the following sizes including providing removable 2 mm thick GI cover knock out holes and fixing accessories earthingcompleterequired including floor/wall/ceiling supports, bends, access boxes and tap off boxes as per specification and cross over as per site requirement. The thickness of raceway & cover shall be as per technical specification. (For electrical wiring).Raceway shall include arrangement for crossing through expansion joints as per Technical Specification / Drawings . 150 mm wide x38 mm deep |
| 106 | Providing and laying 1.6 MM thick Hot deep - galvanizedGI factory fabricated raceways in partition of the following sizes including providing removable 2 mm thick GI cover knock out holes and fixing accessories earthingcompleterequired including floor/wall/ceiling supports, bends, access boxes and tap off boxes as per specification and cross over as per site requirement. The thickness of raceway & cover shall be as per technical specification. (For electrical wiring).Raceway shall include arrangement for crossing through expansion joints as per Technical Specification / Drawings . 300 mm wide x38 mm deep |
| 107 | Junction boxes for above Raceway of the follwing sizes :- 100 mm x 100 mm |
| 108 | Junction boxes for above Raceway of the follwing sizes :- 150 mm x 150 mm |
| 109 | Supplying of following size of 1.1 kV grade FRLS multicore cable aluminium cable. 3.5 C x240 sqmm |
| 110 | Supplying of following size of 1.1 kV grade FRLS multicore cable aluminium cable.3.5 C x120 sqmm |
| 111 | Supplying of following size of 1.1 kV grade FRLS multicore cable aluminium cable.3.5 C x50 sqmm |
| 112 | Supplying of following size of 1.1 kV grade FRLS multicore cable aluminium cable. 3Cx 35 sqmm |
| 113 | Supplying of following size of 1.1 kV grade FRLS multicore cable aluminium cable. 4Cx25 sqmm |
| 114 | Supplying of following size of 1.1 kV grade FRLS multicore cable aluminium cable. 4Cx16 sqmm |
| 115 | Supplying of following size of 1.1 kV grade FRLS multicore cable copper cable 4Cx 16 sqmm |
| 116 | Supplying of following size of 1.1 kV grade FRLS multicore cable copper cable 4cx 10 sqmm |
| 117 | Supply of fire survival multicore 3Cx16 sqmm Al |
| 118 | Supply of fire survival multicore 3Cx 10 sqmm Cu |
| 119 | Supplying and making cable end termination with brass compression gland and copper lugs for following size of XLPE/ PVC insulated PVC sheathed copper conductor cable of 1.1 kV grade as required. 4C x16 sqmm |
| 120 | Supplying and making cable end termination with brass compression gland and copper lugs for following size of XLPE/ PVC insulated PVC sheathed copper conductor cable of 1.1 kV grade as required. 3cX 10 SQMM |
| 121 | Supply of light fixtures 36 w recess mounted 2x2 led fitting complying AAI specifications |
| 122 | Supply of light fixtures Slim compact 15w 4000K, recess mounted round type led fitting complying AAI specifications |
| 123 | Fire AlarmSupply, installation, testing and commissioning ofUL Listed Analogue Addressable type Multi Detector complete with all accessories like base, base box, etc. to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete in all respects as required by the standard specifications. |
| 124 | Supply , Installation, Testing & Commissioning UL listed Intelligent addressable Relay module with built isolator for trigger Hooter & Hooter Cum Strobe etc.The relay andinput are controlled at the same address.Shall bePolarity Insensitive. Devices should be electronically addressed, rotary/DIP switches for addressing are not acceptable and as per the specification. |
| 125 | Dual Monitor Module: Supply , Installation, Testing & Commissioning UL listed Intelligent addressable Monitor module with inbuilt isoaltor having facility to Take input of third partyequipment status monitoring and Interface with PFC/Dry Inputs of Fire Pump Signals, Sprinkler Line Flow Switch Status, Base builder fire alarm panel integration with all the mounting accessories complete as required.Devices should be electronically addressed, rotary/DIP switches for addressing are not acceptable and as per the specification. |
| 126 | Supply, laying, testing and commissioning of 2Cx1.5 sq.mm Fire Survival type, armored copper cable with necessary accessories complete as required. |
| 127 | Fire FightingProviding,laying,testing&commissioningof \"C\"class heavydutyMSpipeconformingtoIS3589/IS1239 includingWelding,fittingslikeelbows,tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia |
| 128 | Providing,laying,testing&commissioningof \"C\"class heavydutyMSpipeconformingtoIS3589/IS1239 includingWelding,fittingslikeelbows,tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 32 mm dia |
| 129 | Providing,laying,testing&commissioningof \"C\"class heavydutyMSpipeconformingtoIS3589/IS1239 includingWelding,fittingslikeelbows,tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 40 mm dia |
| 130 | Providing,laying,testing&commissioningof \"C\"class heavydutyMSpipeconformingtoIS3589/IS1239 includingWelding,fittingslikeelbows,tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :50 mm dia |
| 131 | Providing,laying,testing&commissioningof \"C\"class heavydutyMSpipeconformingtoIS3589/IS1239 includingWelding,fittingslikeelbows,tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 65 mm dia |
| 132 | Providing,laying,testing&commissioningof \"C\"class heavydutyMSpipeconformingtoIS3589/IS1239 includingWelding,fittingslikeelbows,tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia |
| 133 | Providing,laying,testing&commissioningof \"C\"class heavydutyMSpipeconformingtoIS3589/IS1239 includingWelding,fittingslikeelbows,tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia |
| 134 | Providing,laying,testing&commissioningof \"C\"class heavydutyMSpipeconformingtoIS3589/IS1239 includingWelding,fittingslikeelbows,tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150 mm dia |
| 135 | Providing, fixing, testing & commissioning of 15mm dia quartzoidbulbtypesprinklersofrating68degree centigrade with required accessories : Pendant |
| 136 | Providing, fixing, testing & commissioning of 15mm dia quartzoidbulbtypesprinklersofrating68degree centigrade with required accessories : Upright |
| 137 | Supplying, installation, testing & commissioning of sprinklerflexiblepipe(ULListed)ofstainlesssteel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875PSI(Burst)withbranchline(Inlet)25mmNPT malethreadtosprinklerhead(Outlet)15mmNPT femalethreadwithreducer,nipple,2sidebrackets, center bracket, stockbar of following sizes complete as required. 1200mm |
| 138 | Design, SITC of elevator -15 passenger, 5 mtr height Landing Door Frame Stainless steel - Hairline Finish,Power Operated Center Opening type door, Microprocessor based Simplex Collective Selective Control 2 stop glass door lift in arrival hall, complete as required as per the site requirement. |
| 139 | Design, SITC of Escalator (9000 persons per hour, 35 degree inclination, speed 0.5 mps, step width 1000 mm microprocessor controlled with all safety features complete as required as per the site requirement. |
| 140 | Supplying, installation, testing and commissioningofonline double conversion fully microprocessor based ,indoor type, suitable for parallel operation,compact UPS system with IGBT based PWM technology to achieve THD < 3% and input power factor of greater than 0.95 at 50% loading,suitable for Three/Single phase AC input voltage 415/220+/- 20% , 50 Hz +3% / - 3 % and Three/Single phase AC output voltage 415/220V ± 1% volts & frequency 50 ± 0.5 Hz , inbuilt isolation transformer, necessary VRLA batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable (for UPS to Battery and battery to battery), static and maintenance bypass switch, SNMP card for RS232/ ethernet IP computability for operation and monitoring etc. with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. Note : Concerning vendor needs to furnish the battery sizing calculations at the time of GA approval and battery size has to be as per the approved GA drawing.20 KVA(3-ph) |
| 141 | Hand DryerSITC of hand dryer |
| 142 | Design, Supply installation testing commissioning of building signage ceiling suspended LED illuminated type using acryllic sheet using stainless steel pipe for suspending complete as required. |
| 143 | HVAC & Water CoolerSupply installation testing commissioning of VRF unit having capacity of 90 TR, including SITC copper piping, indoor units, insulation drain connection, refnets andassociated works in coordination with other MEP services complete as required by the EIC. The design of indoor units and piping shall be submitted by OEM and got approved by the EIC |
| 144 | SITC of Crossfield make water purifier with model no. UV Plus 6 NHC SS/equivalent model having storage tank capacity 54 ltr, available in hot, cold, normal, having advanced technology UV, UF, Ozone etc. combination complete as required. |
| 145 | Internal /External ElectrificationWiring in Steel & PVC ConduitSupplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 146 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 147 | Wiringforlightpoint/fanpoint/exhaustfanpoint/callbell pointwith1.5sq.mmFRLSPVCinsulatedcopperconductor single core cable insurface /recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the pointwith1.5sq.mmFRLSPVCinsulatedcopperconductor single core cable etc. as required. Group C |
| 148 | Wiringfortwincontrollightpointwith1.5sq.mmFRLSPVC insulated copper conductor single core cable in surface / recessedsteelconduit,2waymodularswitch,modularplate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 149 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessedsteelconduitalongwith1No.4sq.mmFRLSPVC insulated copperconductorsingle corecable forloop earthing as required. |
| 150 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessedsteelconduitalongwith2Nos.4sq.mmFRLSPVC insulated copperconductorsingle corecable forloop earthing as required. |
| 151 | Wiring for circuit/ submain wiring alongwith earth wire with the followingsizesofFRLSPVCinsulatedcopperconductor,single core cable in surface/ recessed steel conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 152 | Wiring for circuit/ submain wiring alongwith earth wire with the followingsizesofFRLSPVCinsulatedcopperconductor,single core cable in surface/ recessed steel conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 153 | Wiring for circuit/ submain wiring alongwith earth wire with the followingsizesofFRLSPVCinsulatedcopperconductor,single core cable in surface/ recessed steel conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 154 | Wiring for circuit/ submain wiring alongwith earth wire with the followingsizesofFRLSPVCinsulatedcopperconductor,single core cable in surface/ recessed steel conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 155 | Wiring for circuit/ submain wiring alongwith earth wire with the followingsizesofFRLSPVCinsulatedcopperconductor,single core cable in surface/ recessed steel conduit as required. 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 156 | Wiring for circuit/ submain wiring alongwith earth wire with the followingsizesofFRLSPVCinsulatedcopperconductor,single core cable in surface/ recessed steel conduit as required. 2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 157 | Wiring for circuit/ submain wiring alongwith earth wire with the followingsizesofFRLSPVCinsulatedcopperconductor,single core cable in surface/ recessed steel conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 158 | Wiring for circuit/ submain wiring alongwith earth wire with the followingsizesofFRLSPVCinsulatedcopperconductor,single core cable in surface/ recessed steel conduit as required.4 X10 sq. mm + 2 X 6 sq. mm earth wire |
| 159 | Wiring for circuit/ submain wiring alongwith earth wire with the followingsizesofFRLSPVCinsulatedcopperconductor,single core cable in surface/ recessed steel conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 160 | MB cable layingLaying ofone numberPVC insulated and PVC sheathed/ XLPE powercableof1.1KVgradeoffollowingsizeintheexisting RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm |
| 161 | Laying ofone numberPVC insulated and PVC sheathed/ XLPE powercableof1.1KVgradeoffollowingsizeintheexisting RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. mm |
| 162 | Laying ofone numberPVC insulated and PVC sheathed/ XLPE powercableof1.1KVgradeoffollowingsizeintheexisting RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm |
| 163 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm |
| 164 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 35 sq. mm and upto 95 sq. mm |
| 165 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 95 sq. mm and upto 185 sq. mm |
| 166 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm |
| 167 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sqmm and upto 95 sqmm |
| 168 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 95 sqmm and upto 185 sqmm |
| 169 | DB\"s & MCBs, IsolatorsSupplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A |
| 170 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A |
| 171 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A |
| 172 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A |
| 173 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 174 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. |
| 175 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door |
| 176 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door |
| 177 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 way (4 + 18), Double door |
| 178 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way (4 + 18), Double door |
| 179 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 180 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. TP |
| 181 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A |
| 182 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
| 183 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \"C\" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 184 | EarthingProviding and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 185 | Cable TerminationSupplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3cX 16 SQMM |
| 186 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4Cx25 sqmm |
| 187 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 120 sq. mm |
| 188 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 50sq. mm |
| 189 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 35 sq. mm |
| 190 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 150 sq. mm (50mm) |
| 191 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 300 sq. mm (70 mm) |
| 192 | Supplying and making indoor cable end jointing with cast resin compound,inclulding lugs and other joint materials for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.185 sq.mm |
| 193 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 194 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 195 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 196 | Supplying and installing following size of perforated Hot Dipped GalvanisedIron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I.bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness |
| 197 | Supplying and installing following size of perforated Hot Dipped GalvanisedIron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I.bolts & nuts, etc. as required. 450 mm width X 50 mm depth X 2.0 mm thickness |
| 198 | Fire AlarmSupplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 199 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 200 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. |
| 201 | Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required. |
| 202 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 203 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 204 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.10 Loop Control Panel having CPU with 640 character display including backlite LCD display qwerty programming and operating manuals, supporting 1 to 10 signaling line circuits (upto 5 extendable cards & supporting 103 network modes) complete as required. |
| 205 | Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required.1 run of cable |
| 206 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color. Use for 24- 26 AWG stranded wires. |
| 207 | Earthing with copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. |
| 208 | Providing and fixing 25mm x 5mm copper strip in 40 mm dis G.I. pipe from earth elecrtrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 209 | Providing and fixing 25mm x 5mm copper strip on surface or in recess for connections etc. as required. |
| 210 | AIRPORT SYSTEM WORKSFlight Information Display SystemSupply of 55 Inch or higher LED Display size monitor with In-Built Intelligent Controller along with display mount with necessary accessories as per specifications |
| 211 | Indoor 3 X 2 VIDEO WALL 46 inch or suitable size True Color LED signage Display Board along with necessary structure (SS Grade) for mounting the displays on Wall/Floor along with display mount with necessary controller and other accessories as per site requirement to meet the fully functional of the system. |
| 212 | Supply of CAT 6 UTP cable (305 meter) |
| 213 | Supply of Power Cable 3 core 1.5 Sq.MM |
| 214 | Supply of Layer 2 network Switch with 24 ports as per specifications |
| 215 | Supply and installation of 9U outdoor Rack/Wall mount with 6 socket 6/16 PDU, FAN along with required mounting accessories as per specifications |
| 216 | Power Junction box (2 Socket with 2 Switch) 5/6 A |
| 217 | Supply of Pole mount on floor 6 ft for installation FIDS displays with necessary mounting accessories as require at site SS Grade (304) as per attached drawing along with VESA Mount interface. |
| 218 | Installation, Testing and Commissioning of the complete system with required accessories of all equipment including Integration, Networking, Cabling, ,laying with PVC, Terminations, Patch Cords, necessary Software, licenses, etc., for fully functional of the system that meet operational performance as per site requirements |
| 219 | SCCTV SystemSupply of Outdoor 2MP IP PTZ Dome Camera, Metal Body with 30X Optical Zoom, 300m IR or better |
| 220 | Supply of 2MP Varifocal Indoor Fixed Colour Dome Camera with 50m IR or better |
| 221 | Supply of Layer 2 network Switch with 24 ports as per specifications |
| 222 | Supply of CAT 6 UTP cable (305 meter) |
| 223 | Supply of Power Cable 3 core 1.5 Sq.MM |
| 224 | Supply and installation of 9U outdoor Rack/Wall mount with 6 socket 6/16 PDU, FAN along with required mounting accessories as per specifications |
| 225 | Camera Connection License(Primary & Failover) for VMS software i2V |
| 226 | Storage HDD Hard Disk (10TB x3 Nos.) compatable to enhance with the existing NAS storage (Make: Huawei, Model:oceanstor 2200 V3) |
| 227 | Installation, Testing and Commissioning of the complete system with required accessories of all CCTV equipment including Integration, Networking, Cabling, laying with PVC, Terminations, Patch Cords, necessary Software, licenses, etc., for fully functional of the system that meet operational performance as per site requirements |
| 228 | Due to modification in Arrival hall the existing cameras are to be Realigned for better coverage for operational requirement |
| 229 | PA System Column Passive Array Speakers (60 Watts) |
| 230 | 500W Audio Power Amplifier |
| 231 | 2 core 1.5 sq. mm speaker cable FS Armoured |
| 232 | Call station |
| 233 | Box Speaker (30 Watt) |
| 234 | Ceiling Speaker(6 Watts) |
| 235 | Installation, Testing and Commissioning of the complete system with required accessories of all equipment including, Networking, Cabling, laying with PVC, Terminations, Patch Cordsetc., for fully functional of the system that meet operational performance as per site requirements |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail