| 1 | Excavation in trenches not exc 1.5 meters wide and not exc1.5 meters deep for pipe line in any type of soil, getting out and levelling of bottom surface to required level complete all as specified and directed. |
| 2 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. |
| 3 | Removing excavated material from site to a distance not exc 50 meters away and depositing where directed not exc 1.5 meter from the starting point complete all as specified and directed. |
| 4 | S & F for DI (Spun) Pressure Pipes of dia 100mm with Spigot & Socket end, Class K9,conforming to IS: 8329/2000 and suitable for (push-on) rubber gasket jointing with inside cement mortar lining with Portland Slag Cement and external Zinc Coating. The standard lengths of the pipes are 5 & 5.5 meter. Also including external bitumenous coating and tyton rubber gasket complete all as specified and directed. |
| 5 | S & F for 150 mm dia cast iron sluice valves and including jointing and testing of PN 1.6, IS-14846, ISI mark flanged ends drilled having stainless steel / brass spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and directed. |
| 6 | All as per Item No 5.00 here-in-above but for size 100 mm dia complete all as specified and directed. |
| 7 | M & L for 100 mm dia CI non return valve without by pass arrangement confirming to IS-5312 part-I, PN 1.6 including nuts, bolts, washers and gaskets complete all as specified and directed. |
| 8 | All as per Item No 7.00 here-in-above but for size 150 mm dia complete all as specified and directed. |
| 9 | M & Lfor CI Y type strainer of dia 100 mm, PN 16, flanged ends including nuts, bolts, washers and gaskets complete all as specified and directed. |
| 10 | M & L for 100mm bore for DI specials such as Tees, collars, tapers,elbow,reducers, tail pieces, caps and plugs,flange spigot and socket etc complete all as specified and directed. |
| 11 | Labour for cutting of 100 mm dia DI pipe in position for reducting to required length for insertion of new tees, branches etc complete all as specified and directed. |
| 12 | M & L for 150 mm bore CI specials such as Tees of any size and radious, collars, tapers,elbow,reducers, tail pieces, caps and plugs etc complete all as specified and directed. |
| 13 | Labour for cutting of 150 mm dia CI/GI pipe in position for reducting to required length for insertion of new tees, branches etc complete all as specified and directed. |
| 14 | M & L for construction of valves pit chamber having internal dismention 120 cm x 120 cm x 120 cm (internal height) using PCC (1:4:8)40 mm graded stone aggregate for foundation 15 cms thick, 23 cm thickwall in CM (1:4) 10 mm thick rendering all around the brick work with 1:6 cement mortar PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 8mm thick MStop sheet cover with locking arrangement including 50 mmpad lock with double key arrangement, MS frame made out of 40 x 40 x 6 mm thick angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers finishing coal including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as specified and including demoletion/ dismentling ofexisting valve chamber complete all as specified and directed. |
| 15 | M & L for flange suitable for 100 mm dia GI pipe complete including necessary welding and fabrication work as required at site and cutting of GI pipe 150 mm dia to required length specially for suction and delivery pipe of booster pump complete all as specified and diredted. |
| 16 | Supply & Laying, Jointing in replacement Galvanized steel water tubing, medium grade of 100 mm bore, screwed and socketed joints with and including all required fittings as in trenches, floors, on walls etc and making good the disturbed surface complete all as specified and directed. Note: Excavation and earth work for fixing in old location already considered in items for taking out and for new locations if required the same shall be paid separately. |
| 17 | All as per Item No 16.00 here-in-above but for size of 80 mm bore complete all as specified and directed. |
| 18 | All as per Item No 16.00 here-in-above but for size of 50 mm bore complete all as specified and directed. |
| 19 | All as per Item No 16.00 here-in-above but for size of 40 mm bore complete all as specified and directed. |
| 20 | All as per Item No 16.00 here-in-above but for size of 25 mm bore complete all as specified and directed. |
| 21 | All as per Item No 16.00 here-in-above but for size of 15 mm bore complete all as specified and directed. |
| 22 | Disconnecting electric/ water connections and removing centrifugal monoblock/ submersible pumpset of capacity upto 2 HP from any type from existing location and transporting pumpset to workshop and back after repair, servicingincluding replacement of undervicable parts such as pump rubber gasket/ seal, foundation nut bolts etc as required and refixing in its original position, testing and comissioning complete all as specified and directed. |
| 23 | M & L in repairs for rewinding of motor reterived from Srl Item No 20 ahere-in-above but of capacity upto 2 HP by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new copper wire of existing gauge and size/ turns, varnishing with insluation, balancing of shaft, incl replacement of UNSV connection plate/ terminal point as required all etc complete assembling the motor complete as per the specified RPM at workshop complete all as specified and directed. |
| 24 | M & L for Power Contractor 3 pole 3 phase Standard coil voltage 240/415 V, 50 HZ, Auxiliary contacts 2 NO+ 2 NC,Current rating 40 Amps complete all as specified and directed. |
| 25 | M & L for Power Contractor 3 pole 3 phase Standard coil voltage 240/415 V, 50 HZ, Auxiliary contacts 2 NO+ 2 NC,Current rating 32 Amps complete all as specified and directed. |
| 26 | S & F in replacement of submersible starter panel for 2.0 Hp pump set single phase 50Hz complete all as specified and directed. |
| 27 | Supply only Microprocessor based electronic meters temper proof LCD display with polycarbonate cover 230V, 10-60 Amps rating, accuracy class-1, 50 Hz. confirming to IS-13779, IP-54 with parameters to show data, time cements reading, load, P. Voltage & KWH complete all as specified and directed. |
| 28 | Supply only Microprocessor based electronic meters temper proof LCD display with polycarbonate cover,Smart three phase four wire 415 Volts, 10-60 Amps rating, accuracy class-1, 50 Hz, confirming to IS 16444 : 2015 (Reaffirmed 2020) marked in existing meter board/ floor panels,with parameters to show data, time cements reading, load, P. Voltage & KWH complete all as specified and directed. |
| 29 | Takingdown carefully copper /aluminium point wiring light/fan, socket or power point /AC point complete including fittings such as switches, sockets, ceiling rose, bell push, bell buzzer, lamp holder bracket, fan regulator, tube light fitting etc removing from site and making good disturbed surface of wall, floor etc as exists complete all as specified and directed. |
| 30 | M & L for flame proof wiring with single core PVC insulated and unsheathed 1100 volt grade (FRLS) electric cable with multi stranded copper conductor of size 2.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia concealed type including allflame proof conduct fittings and accessories such as tees junction boxes, bends duly tested by CMRI Dhanbad suitable for one light /fan point controlled by one flame proof rotary switch SP one way and including drawing continuous earth wire PVC insulated unsheathed 1100v grade cable withstranded copper conductor of size 1.5 Sqmm and connected to earth dolly complete conforming to IS-694 complete all as specified and directed. |
| 31 | S & F in replacement flame proof/weather proof direct entry typerotary switch singlepole on & OFF rotary motion switch in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 230Volts 16 Amps, AC ON/OFF switch operated externally by Knob having 02 Nos of M-20 cable entries, earthing terminals suitable for mounting on Wall/Steel structure etc duly tested & certified by CMRI-Dhanbad complete all as specified and directed. |
| 32 | S & F in replacement flame proof switch socket and plug combined in LM-6 cable termination box in LM-6, 16 A, 250 V, 2P plus earth complete all as specified and directed. |
| 33 | M & L for sub main wiring with multistranded copper conductor cable FR -PVC sheathed in and including ERW rigid steel stove enameled conduit 19/20mm dia along with all flame proof and weather proof accessories such as multiple junction boxes, covers,elbow, bends,tees etcwith two runs of4.0 Sq mm and4.00 Sq mm flexible copper wire as earth wire and connected to earth dolly completeall includingchase cutting and making good the disturbed surfaces complete all as specified and directed. |
| 34 | S & F LED 1x16 Watt flame prooflight fitting, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.Note : (a) All fittings shall be ISI marked and shall have approval of CMRI Dhanbad.(b) Original Test certificate of Manufacturer shall be produced by Contractor. |
| 35 | S& F in replacement of flame proof LED flood light luminaries 120 watt comprising of body made in cast alluminum alloy LM6 construction luminaries spun alluminium reflector fitted inside main body main body, heat resistant toughend glass cemented to cast aluninuuim, retainging ring fixed to main body , mounted on MS galvanised iron cradle and base plate for rotating in horizontal and vertical planes,voltage 140-270,IP 65 , main connector suitable up to 6 Sqmm incoming cable, terminal enclosure plain covers are fixed by means of socket head allen cap stainless steel screw, conforming to standard IS/IEC 60079-0-2004, IS/IEC 60079-1-2007 , earthing with internal 1 No, external 2 Nos on main Enclosure M6x 12MSscrew & plain washer complete all as specified and directed. |
| 36 | S & F 250 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy , cast aluminium alloy housing IP 66 protection, input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95,driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting, complete all as specified and directed. |
| 37 | S & F 150 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy , cast aluminium alloy housing IP 66 protection, input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, , having name of manufacturer and logo embossed on housing of each light fitting, including taking down existing light fittings complete all as specified and directed. |
| 38 | S & F 120 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy, cast aluminium alloy housing IP 66 protection, input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, having name of manufacturer and logo embossed on housing of each light fitting,including taking down existing light fittings complete all as specified and directed. |
| 39 | M & L for replacement of concealed point wiring complete with PVC insulated and unsheathedFRLS cable of 1.5 sqmm (nominal area) with multistranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia,with MS stove enamelled sunkenboxes (normal and modular type as required) including earth dollywith plastic laminated sheet top cover (cover plate with frame in case of modular)of approved make and colour including 1.5 sqmm multistranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified anddirected for the followings:-One light / fan point controlled by one way switch |
| 40 | All as per Item No 39.00 here-in-above but One 5 Amp socket outleton independent board complete all as specified and directed. |
| 41 | All as per Item No 39.00 here-in-above but One 5 Amp socket outlet on same board complete all as specified and directed. |
| 42 | All as per Item No 39.00 here-in-above but One 5 Amp bell /buzzer point controlled by bell push complete all as specified and directed. |
| 43 | All as per Item No 39.00 here-in-above but One light point controlled by 2 way switch complete all as specified and directed. |
| 44 | All as per Item No 39.00 here-in-above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed,FRLS cable for 15 Amp socket outleton independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and directed. |
| 45 | M & L for replacement of point wiring in casing caping on sufraces of wall/ceiling floor etc complete with PVC insulated and unsheathedFRLS cable of 1.5 sqmm (nominal area) with multistranded copper conductor single core 1100 volts grade with PVC rectangular block of suitable size including 1.5 sqmm multistranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etccomplete all as specified and as directed for the followings:-One light / fan point controlled by one way switch |
| 46 | All as per Item No 45.00 here-in-above but One 5 Amps socket out let point controlled by one 1-way switch on independent board complete all as specified and directed. |
| 47 | All as per Item No 45.00 here-in-above but One 5 Amps socket out let point controlled by one 1-way switch on same board complete all as specified and directed. |
| 48 | All as per Item No 45.00 here-in-above but using 2.5sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for15 Amp socket outleton independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and directed. |
| 49 | M & L for replacement of existing conduit point wiring complete with PVC insulated and unsheathedFRLS cable of 1.5 sqmm (nominal area) with multistranded copper conductor single core 1100 volts grade drawn through existing conduitwith MS stove enamelled sunkenboxes (normal and modular type as required) including earth dollywith plastic laminated sheet top cover ( cover plate with frame in case of modular)of approved make and colour including 1.5 sqmm multistranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified anddirected for the followings:-One light / fan point controlled by one switch. |
| 50 | All as per Item No 49.00 here-in-above but One 5 Amps socket out let point controlled by one switch on independent board complete all as specified and directed. |
| 51 | All as per Item No 49.00 here-in-above but One 5 Amps socket out let point controlled by one switch on same board complete all as specified and directed. |
| 52 | All as per Item No 49.00 here-in-abovebut with 2.5 Sqmm nominal cross sectional area electric cable for 15 Amps socket outlet point controlled by one switch on independent board complete all as specified and directed. |
| 53 | S & F in replacement switch piano type 5 amp one way ISI Marked complete all as specified and directed. |
| 54 | S & F in replacement switch piano type15 Amps one way ISI Marked complete all as specified and directed. |
| 55 | S & F in replacement socket outlet 5 pin 5 Amps flush type complete all as specified and directed. |
| 56 | S & F in replacement socket outlet 2-in-1, 6 pin 5 amp and 15 amps complete all as specified and directed. |
| 57 | S & F in replacement socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directed. |
| 58 | S & F in replacement socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed. |
| 59 | S & F in replacement switch 6 amps modular type one way complete all as specified and directed. |
| 60 | S & F in replacement switch 16 amps modular type one way complete all as specified and directed. |
| 61 | S & F in replacement electronic fan regulator Step type & flush type complete all as specified and directed. |
| 62 | S & F in replacement of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and directed. |
| 63 | S & F in replacement ofLamp holder bakelite type with back plate suitable for batten fittingscomplete all as specified and directed. |
| 64 | S & F in replacement of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of4.0 sqmm multistranded copper conductorsingle core PVC insulated, unsheathed cable of green colouras continuous earth wire including lugs etc connected and tested complete all as specified and directed.Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length. |
| 65 | S & F in replacement ofsub main wiring with PVC insulated, FRLS, unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directedwith and including one run of6.0 sqmm multistranded copper conductor single core PVC insulated, unsheathed cable of green colouras continuous earth wire including lugs etc connected and tested complete all as specified and directed.Note: (i) Two runs of 6.0 sqmm cable and one run of 6.0sqmm cable of earth continuity conductor and conduit shall be a unit length. |
| 66 | S & F in replacement ofRigid non-metallicPVCconduit25 mm(external dia) ISI marked (on surface) incl of all accessories and all fittings such as Tees bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers lock nuts, saddles, pipe hook etc complete all as specified and directed. |
| 67 | All as per Item No 67.00 here-in-above but for 20mm size complete all as specified and directed. |
| 68 | S & F in replacement of PVC casing capping 20/25mmISI marked complete all as specified and directed. |
| 69 | M & L for fixing PVC gang box for mounting one switch and one socket of 5 Amps including all accessoriese complete all as specified and directed. |
| 70 | M & L for fixing PVC gang box for mounting one switch and one socket of 15 Amps including all accessoriese complete all as specified and directed. |
| 71 | S & F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 12 ways 240 V including fixing in new location with connection of circuit and submain as per site requirement complete all as specified and directed. Note: (a) MCBs are to be measured and paid seperately. (b)Make ofMCBs and DB should be same.(c) Extra circuit length where DBs are to be shifted from existing location to new location shall deemed to be included in the quoted rate. |
| 72 | All as per Item No 71.00 here-in-above but for 8 ways complete all as specified and directed. |
| 73 | All as per Item No 71.00 here-in-above but for 4 ways complete all as specified and directed. |
| 74 | S & F in replacement of single pole and neutral enclosure with 2 pin and metal earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed. |
| 75 | S & F in replacement MCB SP 5 to 32 Amps,240 volts curve \"B\",breaking capacity 10KA, complete all as specified and directed. |
| 76 | S & F in replacement MCB SPN16 to 40 Amps,240 volts, curve \"B\", breaking capacity 10 KA, complete all as specified and directed. |
| 77 | S & F in replacement MCB SPN40 to 63 Amps,240 volts,curve \"B\", breaking capacity 10 KA, complete all as specified and directed. |
| 78 | S & F in replacement ofmodular Fan Regulator fan step regulator,120W- single module ISI Marked complete all as specified and directed. |
| 79 | S & F in replacement of modular blanking plate, 1 module ISI Marked complete all as specified and directed. |
| 80 | S & F in replacement metal flush box for 3 module complete all as specified and directed. |
| 81 | All as per Item No 80.00 here-in-above but for 4 module complete all as specified and directed. |
| 82 | All as per Item No 80.00 here-in-above but for 6 module complete all as specified and directed. |
| 83 | All as per Item No 80.00 here-in-above but for 8 module complete all as specified and directed. |
| 84 | S & F in replacement for white cover plate with frame, 3 module complete all as specified and directed. |
| 85 | All as per Item No 84.00 here-in-above but for 4 module complete all as specified and directed. |
| 86 | All as per Item No 84.00 here-in-above but for 6 module complete all as specified and directed. |
| 87 | All as per Item No 84.00 here-in-above but for 8 module complete all as specified and directed. |
| 88 | Supply and fixing in repair ofEarthing to DBs with galvanised steel earth plate electrode60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board includingexcavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed. |
| 89 | M & L in repair for Earth continuity conductor or main earthing lead of 4.0 Sqmm galvanized iron wire, buried in ground or fixed to wall in and including 15 mm bore GI pipe medium grade for protection of earth wire complete all as specified and directed. |
| 90 | S & Fin repair plastic laminated bakelite sheet cover of size 100mm x 100mm Hylam brand including cutting holes for switches, sockets etc as pre requirement including fixing with machine screws and washer complete all as specified and directed. |
| 91 | All as per above Item No 90.00 here-in-above but of size 175mm x 100mm size complete all as specified and directed. |
| 92 | All as per above Item No 90.00 here-in-above but of size 200mm x 150mm size complete all as specified and directed. |
| 93 | All as per above Item No 90.00 here-in-above but of size 250mm x 200mm size complete all as specified and directed. |
| 94 | All as per above Item No 90.00 here-in-above but of size 350mm x 300mm size complete all as specified and directed. |
| 95 | S & F in replacement of Cable PVC insulated unsheathed singlecore 1100V FRLS grade stranded flexible copper conductor of size 1.5 sqmm complete all as specified and directed. |
| 96 | S & F in replacement of Cable PVC insulated unsheathed singlecore 1100V FRLS grade stranded flexible copper conductor of size 2.5 sqmm complete all as specified and directed. |
| 97 | S & F in replacement of Cable PVC insulated unsheathed twin core of 23/0.0076 size flexible copper conductor complete all as specified and directed. |
| 98 | S & F in replacement of Cable PVC insulated unarmoured three core 1100V FRLS grade stranded flexible copper conductor of size 2.5 sqmm complete all as specified and directed. |
| 99 | S & F 25 mtr long 2.5 cm wide and atleast .125 mm wall thickness self adhesive PVC insulated electrical tape roll of good quality complete all as specified and directed. |
| 100 | S & F in replacement of PVCround shape junction box cover of suitable size including fcomplete all as specified and directed. |
| 101 | Taking down light fittings of any type any size any location complete all as specifed and directed. |
| 102 | Taking down DB including old U/s MCB/MCCB of any size any type from any location complete all as specifed and directed. |
| 103 | S & F in replacement of 09 watt 2 star LED bulb with B22 /B27 Base cap as required, 1200 lumens, Colour rating Index 80,colour temp warm white ,satrtup time less than 2 sec,In built surge 3.0 kV, voltage range 140V to 270 V , Lamp life 15000 hours complete all as specified and directed. |
| 104 | S & F in replacement enviroment friendly recess/pendent mounting 36 watt LED flat panel 2\"x2\" fabricated CRCA sheet steel duly powder coated housing cool white with high efficient LEDs & glare free opal diffuser PF>0.95 , lumen efficacy>100 lm/W, THD<10% operating range 220v to 240V,CRI>80, Colour Temerature 3500/4000 K (Warm White) including connection with existing wire and all accessories all as specified and directed. |
| 105 | S & F in replacement of enviroment friendly indoor decorative 5/6 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt, THD≤20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed. |
| 106 | S & F in replacementenviroment friendly,ultra modern,energy saving surface mounted decorative 10 Watt LED bulkhead fitting modular type with polycarbonate housing ,high efficient LEDs with opal diffuser and IP65 protection, lumen efficacy 85 lm/watt with colour temerature 6500K, THD≤20 CRI>80,2.5 kV surge protection complete all as specified and directed. |
| 107 | S & F 12 watt LED bulb with B22 Base cap, 1200 lumens ,Colour rating Index 80,colour temp F 6500K,satrtup time less than 2 sec, In built surge 3.0 kV, voltage range 140V to 270 V, Lamp life 15000 hours complete all as specified and directed. |
| 108 | S & F in replacement of enviroment friendly indoor decorative 20 Watt LED Polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt, THD≤20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessories complete all as specified and directed. |
| 109 | S & F in replacement enviroment friendly recess/surface mounting 36 watt LED flat panel 2\"x2\" fabricated CRCA sheet steel duly powder coated housing cool white with high efficient LEDs & glare free opal diffuser PF>0.95 , lumen efficacy>100 lm/W, THD<10% operating range 220v to 240V,CRI>80 including connection with existing wire and all accessories complete all as specified and directed. |
| 110 | S & F in replacement of enviroment friendly indoor decorative 10 Watt, 2 feet , mirror type LED lampwith opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessories complete all as specified and directed. |
| 111 | S & F in replacement of bell push flush type 5 A complete all as specified and directed. |
| 112 | S & F in replacement ofmodular bell push 6 A one module complete all as specified and directed. |
| 113 | S & Fin replacement ofding dongbell, AC 230 V, single polecomplete all as specified and directed. |