| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. DSR 2.6.1 (2023) |
| 2 | 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) DSR 4.1.8 (2023) |
| 3 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR 5.1.2 (2023) |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete DSR 5.9.1 |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 6.1.1 (2023) |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR 5.3 (2023) |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6 |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.3 |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars DSR 5.1.3 (2023) DSR 5.22.1 (2023) |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 6.4.1 (2023) |
| 11 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) DSR 13.4.1 (2023) |
| 12 | Providing and laying Polished Granite stone slab of colou rBlack,Cherry/Ruby Red or equivalent Polished Granite stone flooring in required design and patterns,in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20mm(average)thick base of cement mortar1:4(1cement:4coarsesand)laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing,curing and polishing etc. all complet specified and as directed by the Engineer-in-Charge. DSR 11.56.1 (2023) |
| 13 | S/F Signboard And photography Please Enable Macros to View BoQ information |