| Sl. No. | Item Description |
| 1 | Supply, fixing and erection in replacement of4 mtr decorative Pole with base, aesthetically designed Jet black(RAL 9005) painted, galvaninsed (>35 microns)pole in different cross section with golden yellow colour decorative ring & joint reducer embellishment of aluminium die casting including base plate of size 200x200x10mm thick,(as per manufacture approved Drg) M16 x450mm foundation and nuts & bolts along with template. The external surface of the pole should be finished by single layer primer and double layer of anti-corrosive polyurethane paint (>=50 microns). The pole should be 3mm thick,min dia meters at the bottom is 114mm and 3mm thick at the top is 60mmsuitable for 45-watt LED Post top light decorative circular design, accessories completeall as specified and directed. Flushed type Window/ door opening along with 6A MCB SP and 4-way 25sqmm cable connector block 32A with locking arrangement at 600 mm above base plate. Inspection will be done by Engr in Charge before dispatchalong with test report. Before placing the order the sample piece to be approved by GE. Some Pole shall be laid at new place the credit of it will not be catered in Sch of Credit. Make:Bajaj CAT Part No BJPL02 4M ECO POLE (TOP Dia 60MM) orequivalent in Philips/Havells/Wipro |
| 2 | Supply & fixing in replacement of decorative Circular, aesthetically designed LED Post Top light, 45 watt 3000K, 50000 Burning hours of maintenance output & 4500 lumens output & CRI>80, IK 10 with optical grade PC diffuser,Pressure die cost aluminium single body and IP66 , anti corrosive epoxy powder coated, the dia of the light suitable for top ofthe pole dia 60mm complete all as specified and directed.Before placing the order the sample piece along with above quoted pole to be approved by GE. Some lights shall be laid at new place the credit of it will not be catered in Sch of Credit. Make:Bajaj CAT Part No BL ARCHNER PRO NX 45W 3K C3 S / Havells CAT Part No.RINKPT45WLED757PSYMTOPC or equivalent in Philips/Wipro |
| 3 | Supply, fixing and erection in replacement of4 mtr decorative Pole with decorative double Arm bracket suitable for 45W Post top as per attached drawing/image, aesthetically designed Jet black(RAL 9005) painted, galvaninsed (>35 microns)pole in different cross section with golden yellow colour decorative ring & joint reducer embellishment of aluminium die casting including base plate of size 250x250x10mm thick,(as per manufacture approved Drg) M16 x450mm foundation and nuts & bolts along with template. The external surface of the pole should be finished by single layer primer and double layer of anti-corrosive polyurethane paint (>=50 microns). The pole should be 3mm thick,min dia meters at the bottom is 114mm and3mm thick at the top is 60mmsuitable for 45-watt LED Post top light decorative circular design, decorative 10 sqmm rod designed versatile brackets and Double Arm brackets and including all fixtures, accessories completeall as specified and directed. Flushed type Window/ door opening along with 6A MCB SP and 4-way 25sqmm cable connector block 32A with locking arrangement at 600 mm above base plate. Inspection will be done by Engr in Charge before dispatchalong with test report. Before placing the order the sample piece to be approved by GE. Some Pole shall be laid at new place the credit of it will not be catered in Sch of Credit. Make:Bajaj CAT Part No BJPL 06 4M ECO POLE WITH DA BRACKET (TOP Dia 60MM) orequivalent in Philips/Havells/Wipro |
| 4 | Supply & fixingof decorativeaesthetically designed LED luminaire Post Top light, 45 watt 3000K , With 50000 Hurning hours of maintenance output & 4950 lumens output & CRI>70, IK 08 with aluminium housing & Al heat sink and optical grade UV resistantPC diffuser,IP 66 withpowder coated. The dia of the light suitable for top (48mm)ofthe double arm bracket as above complete all as specified and directed.Inspection will be done at the Factory premises before dispatchalong with test report.Before placing the order the sample piece along with above quoted decorative double Arm bracket to be completed and approved by GE . Make:Bajaj CAT Part No BOR NX 45W 30K DO C3 GG S PT or equivalent in Philips/Havells/Wipro makecomplete all as specified . |
| 5 | Supply & fixingofLED TRI colour light 4mtrColumn with die-cast aluminium top with cylindrical opal polycarbonate diffuser deigned for rugged outdoor usage & IP 65 protection, with inbuilt driver & surge protection (int 4kv & ext 10 kv) Polyurethane finish & maintenance output of 50000 burning hours , Lumin output of 5000 lumenscomplete with all nuts & bolts complete all as specified and directedby Engr-in-Charge.Make:Bajaj CAT Part No BLSLC 50W LED TRI 4Mor equivalent in CG/Philips. |
| 6 | Supply and fixing in replacement LT 3phase Junction box for street light, sheet moulding compound (SMC) type with hinged type door and locking arrangement, off white colour, of size 250 x 150 x 100mm(internal)comprising 10 Amps SP MCB, 3 Phase and Neutralincoming cable, 3 Phase and Neutral outgoing cable and single Phase & Neutralconnection for light fitting 01 No bakelite base neutral link and 01 No earthing terminal bolt and nut and connecting up cables with aluminium terminal lugs incl fixing arrangements including Wiring from junction box to Street Light fitting alongwith with 2x2.5 sq.mm + 1x2.5 sq. mm earth wire of FR PVC insulated copperconductor, single core cable in surface/recessed as required in PVC conduit complete all as specified and directed by Engr-in-Charge. |
| 7 | Supplying, installing, testing & commissioning out door type cubical panel board outer shell made out of3.15 mm thick MS sheet including door and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm aboveand 45 cm below the ground level,frame factory fabricated with front & back openable, double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keyshaving chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricatedhaving modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :- |
| 8 | a) Aluminium bus bar 400 Amps cap 4 wire fixed on insulator not less than 1.0 mtr long bus bar -1 set(b) Incoming MCCB 250A Amps 4 pole 415 Volts AC with thermal magnetic 36 KA, Ics=100%, Icu class-2 front face isolation with positive break indication with double break contacts with spreader and phase barrier complete all as directed. - 1 Nos.Location: Middle of the Polo ground(Near SMC)(c) Outgoing MCCB 160 Amps 4 pole 415 Volts AC with thermal magnetic 25 KA,with double break contacts with spreader and phase barrier complete all as directed. -1 Nos (d) Outgoing MCCB 100 Amps 4 pole 415 Volts AC with thermal magnetic 25 KA,with double break contacts with spreader and phase barrier complete all as directed. -2 Nos (e) Outgoing MCCB 63 Amps 4 pole 415 Volts AC with thermal magnetic 16 KA,with double break contacts with spreader and phase barrier complete all as directed. -2 Nos (f) Outgoing MCB 32 Amps 4 pole 415 Volts AC with thermalcomplete all as directed. -2 Nos (g) Digital Ammeter 0-500 A of size 96sqmm with selector switch-01 No.(h) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No(j) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming including back up protection by 2 Amp MCB RYB with holder-01 set of three.(k) CT Coils of suitable ratio-01 Set. |
| 9 | (l) Single dial time switch, 65A TP contactor for the automatic switching of luminaries, power tool control with 2 No. 65A contactors and raise lower push button, Incoming 35 sq. mm and out going 25sq. mm 4 core terminals. -02 SetsNote :-(i)The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc.(ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming toIS-694.(iii) Panel drawing shall be got approved before placing of orderfrom Engr-in-Charge/GE.(iv)The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated.(vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4incl masonary work leaving ducts for cables complete all as directed.(vii) All MCCBs have Ics= 100% Icu. |
| 10 | Supplying, installing, testing & commissioning out door type cubical panel board outer shell made out of3.15 mm thick MS sheet including door and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm aboveand 45 cm below the ground level,frame factory fabricated with front & back openable, double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keyshaving chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricatedhaving modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :- |
| 11 | (a) Aluminium bus bar 200 Amps cap 4 wire fixed on insulator not less than 1.0 mtr long bus bar -1 set(b) Incoming MCCB 100 Amps 4 pole 415 Volts AC with thermal magnetic 36 KA, Ics=100%, Icu class-2 front face isolation with positive break indication with double break contacts with spreader and phase barrier complete all as directed. - 1 Nos.(c) Outgoing MCCB 63 Amps 4 pole 415 Volts AC with thermal magnetic 25 KA,with double break contacts with spreader and phase barrier complete all as directed. -3 Nos (d) Outgoing MCB 32 Amps 4 pole 415 Volts AC with thermalcomplete all as directed. -2 Nos (e) Digital Ammeter 0-500 A of size 96sqmm with selector switch-01 No. (f) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No. (j) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming including back up protection by 2 Amp MCB RYB with holder-01 set of three. (k) CT Coils of suitable ratio-01 Set. |
| 12 | (l) Single dial time switch, 65A TP contactor for the automatic switching of luminaries, power tool control with 2 No. 65A contactors and raise lower push button, Incoming 35 sq. mm and out going 25sq. mm 4 core terminals. -02 SetsNote :-(i)The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc.(ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming toIS-694.(iii) Panel drawing shall be got approved before placing of orderfrom Engr-in-Charge/GE.(iv)The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated.(vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4incl masonary work leaving ducts for cables complete all as directed.(vii) All MCCBs have Ics= 100% Icu. |
| 13 | Supply & fixing GI tubing lightgrade 80 mm bore on poles, under floors, road crossing etc complete all as specified and directed by Eng-in-Charge |
| 14 | Supply & fixing GI tubing lightgrade 50 mm bore on poles, under floors, road crossing etc all as reqd at site complete all as specified and directed by Eng-in-Charge |
| 15 | M & L in replacement of out door aluminuam bus bar chamber feeder box of cap 300 Amp , 3 phase, 4 wire, 415 Volts with porcelain insulator weather and vermin proof with IP 54 protection, made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer type ,both side openable,from front side & back having, locking arrangement on both sides,mounted over 50x50x6 mm angle iron stand at the bottom of height not less than 45 cm above ground level and not less than 30 cm in ground / floor mounted duly grouted in PCC 1:3:6 type C1 (using 20mm graded stone aggregate)factory made duly powder coated includingMCCB 200Amp 36KA four pole x 01 Nos as a Incomer all as directed by Engr-In-Charge. |
| 16 | Supply & fixing Sub main wiring with two single core PVC insulated unshesthed cable copper conductor(FRLS-H) of size 2.5 sqmm multistrandedand one run of 2.5 sqmm PVC insulated unsheathed copper conductor(FRLSH) as earth continuty conductor drawing in and including non-metalic PVC rigid conduit 25mm dia ISI marked with all conduit accessories concealed in wall, cutting of chases in walls, floors, ceilings, beams etc and making good the disturbed surfaces as directed including taking down old unservicable wiring complete all as specified and directed. (Two run of single core cable and one run of earthing cableand one run of PVC conduit shall be measured as one length.) |
| 17 | Supply and fixing for earthing complete with galvanized iron earth plate electrode 600x600 x6.0mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected to GI strip of size 32X6mm as earthing lead by means of nuts, bolts, check nuts and washersof galvanized iron or steel all as shown on Electrical PlateNo 3 of SSR Part-I 2009, connected to earthingtest point all as specified or indicated including testing on completion. The quoted unit rate shall include the following elements as given below :-(a) Earth electrode as mentioned above (b) Main earthing lead of 32X6 mm GI strip from earth electrode to test point up to 7.5 mtrs. (c) Connecting earthing leadand electrodeall as specified and testing complete. (d) Adequate quantity of charcoal and salt(e) GI protection pipe of 40 mm dia lightgrade of length not less than5.00 mtrs. (f) Necessary excavation, earth work and PCCpit , angle iron 40x40x6mm frame including RCC cover. |
| 18 | Exacavation for cables loops near the poles LT Panels/transformers, cutting the damages/burnt parts of cable and reconnecting its positions complete with thimbles, nut bolts, sleeves complete all as specified and directed by Engineer-in-Charge. |
| 19 | Taking out carefully manually by excavation of existing LT/HT cable with loops and relaying with DWC pipe/brick the same after repair of cutting the damages / burnt parts of cable and reconnecting its into originalpositions complete with cable joints all as specified and directed by Engineer-in-Charge.Note : -(i)HT/LT Cable Joint & DWC Pipe/Brick will bemeasured and paid sepearetly. (ii) Unit rate shall be included in excavation and returning filling. (iii) Handling of UG cable to working site as ordered shall be carried out by the firm and rate for the same shall deem to be included in the unit rate. |
| 20 | M & L in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint. |
| 21 | Supply and Fixingin replacement of on load change over315 Amp 4 pole complete withwith Sheet metal encloser incl operating handle and dismantling/connection ofexisting cables complete as specified and directed by Engineer-in-Charge. |
| 22 | S & F of Cable jointing kit suitable for 1.1 KV grade cable end termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 95 sqmm complete all as specified and directed by Engr-in-Charge. |
| 23 | S & F of Cable jointing kit suitable for 1.1 KV grade cable end termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 to185 sqmm complete all as specified and directed and directed by Engr-in-Charge. |
| 24 | Supply & fixing in replacement outdoor type tiranga LED Rope light suitable for 9/11 mtr electric PCC/SteelPole decorative, Operting Voltage 140-270 Volts 240V AC Supply 50Hz supply connection from down side Jn box including driver and two run of 1.5 sqmm single core unarmoured wire from Junction boxcomplete all as specified and directed by Engr-in-Charge. |
| 25 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft/loose soil for laying of LT UG cablescomplete all as specified and directed by Engr-in-Charge. Note : The Ratequoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be staged at desired location as directed at site |
| 26 | Returning, filling in,including spreading levelling, watering and well ramming in layers not exceeding 25 cm thickin soft/loose soil all as specified and directed by Engr-in-Charge . |
| 27 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed by Engr-in-Charge. |
| 28 | Material and labour for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in mass concrete in foundation of poles complete all as specified and directed by Engr-in-Charge. |
| 29 | Material and labour for PCC 1:3:6 type C-1using 20mm graded crushed stone aggregate as in mass concrete in foundation of stays complete all as specified and directed by Engr-in-Charge. |
| 30 | Supply and laying GI steel tubing, 100 mm bore, light grade with all fittings, laid in trenches / under roads / along pole / wallfor protection ofCable / GI wire / GI strip etc complete all as specified and directed by Engr-in-Charge. |
| 31 | Labour for drilling hole under the road with the help of drilling machine without damaging the road horizontally for road crossing in and including HDPE pipe 160mm dia,SDR 13.6(8Kg/SQCM) 145.04 PSI pressure pipefor cable protection complete all as specified and directed by Engr-in-Charge.Note :Driling of hole under the road2 to 3 mtr depth andMinimum one slot length 5mtr before drillingsignal cable clearance should be received from signal Unit. During the drilling any type of cable damage,the same shall be repaired by contractor without any extra cost. |
| 32 | S&F for capacity luminaires 500 watt LED, CCT 5665±355Kwith suitable bracket and nut bolt of new Flood light IP 66, pressure die-cast aluminium housing, Luminare efficacy 120LPW, 50000 Burning Hrs, THD <10%, Input Voltage 140-270 Volts, PF ≥0.95,LED driver current > 850 mA (Potted Driver),10 KV external Surge Voltage Protection, Internal surge protection 4 Kv,toughned glass cover with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtrcomplete all as specified and directed by Engr-in-Charge. |
| 33 | Supply & fixingfor single core PVC insulated unsheathed cable copper conductor of size 2.5 sqmm multistranded drawing innon-metalic PVC rigid conduit complete all as specified and directed by Engr-in-Charge. Note : PVC Conduit will be measuredand paid seperatly as relevent item. |
| 34 | Supply and fixing for rigid non-metallic PVC conduit 25mm dia (Heavy duty)in concealed exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. including taking out old conduit complete all as specified and directed by Engr-in-Charge. |
| 35 | Supply and Fixingfor MCB SPN 40Amps C Curve 25 KA with Sheet metal encloser, complete all as specified and directed by Engr-in-Charge. |
| 36 | Supply and Fixingfor MCB Single Pole Neutral16/25Amps C Curve25 KA with Sheet metal encloser, complete all as specified and directed by Engr-in-Charge. |
| 37 | Material & Labour for brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), including dismantling of unserviceable brick work complete all as specified and directed by Engr-in-Charge. |
| 38 | M&L for rendering 10 mm thickon fair faces of brick work or concrete surfaces, finished even and smoothon walls in cement mortar (1:6) complete all as specified and directed by Engr-in-Charge. |
| 39 | S&F for two core 2.5 Sqmm PVC Copper cable with an inner sheathing of PVC tape and over all PVC Sheathed insulatedmulti stranded conductor 1100 volts grade complete all as specified and directed by Engr-in-Charge. |
| 40 | S & F for cable route indicator made out of 45 x 45 x 5 mm angle iron, 80 mm long embedded in PCC block of suitable size with moulded lettter HT CABLE or LT CABLEsuitably on CI circular plate 8 mm thick 100 dia complete incl neccessary PCC 1:3:6, type C-2 (using 40 mm graded crushed stone aggrregate)block of suitable size and neccessary earth work and excavation complete all as specified and directed by Engr-in-Charge. |
| 41 | Material and Labour for road cutting, including excavation, returning filling in, spreading, leveling, well ramming in layers, soiling with broken boudders/stones, WBM 7.5 cm thick coarse aggregate received from dismentling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work complete all as specified and directed by Engr-in-Charge. |
| 42 | Dismantling of interlocking cement concrete (any thickness/size), on floor fixed in cement mortar in single layer complete all as specified and directed by Engr-in-Charge. |
| 43 | M & L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS- 15658-2006 of 60mm thickness , M-35 grade, with grey cement and pigment complete all as specified and directed by Engr-in-Charge. |
| 44 | Description all as per srl item No 39 above but except interlocking cement concrete tiles, (Any thickness/size) (old interlocking tiles obtained from srl items No 38, complete all as specified and directed by Engr-in-Charge. |
| 45 | M & L for 25 mm thick sand fillimg under floor/interlocking tiles etc complete all as specified and directed by Engr-in-Charge. |
| 46 | Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) and disposing the rubbish to a distance exceeding complete all as specified and directed by Engr-in-Charge. |
| 47 | Supply & Fixingfor PVC insulated sheathed service wiretwin core 10 Sqmm aluminium multistranded conductor 1100 volts grade incl taking down old unserviceable one. |
| 48 | Supply & Fixingfor PVC insulated sheathed service wiretwin core 16 Sqmm aluminium multistranded conductor 1100 volts grade incl taking down old unserviceable one. |
| 49 | Supply and Fixing for in replacement ofMCCB 350Amps 4 pole 36 KAwith adjustablethermal and fixed magnetic setting, complete all as specified and directed. |
| 50 | Supply & fixing in replacement of integral decorativeLED Bollards 9w 5700K in cylindrical shapeunique design, with opal PC diffuser and IP66 protection min ht 1mtrcomplete with all fixing accessoriescomplete all as specified and directed. Make : Bajaj CAT Part No BGBOL 1000 9w LED WH or equivalent in CG/Havells/Philips. |
| 51 | Supply and fixing for replacementthermoplastic polycarbonate cable junction boxhinged door type of size 200x160x 98 mm for 3 Phase and Nutralincoming cable, 3 Phase and Nutral outgoing cable and single Phase & nutralconnection for light fitting withaluminiuam bus bar of 25 x 3mm strip, 4 pole, 415 volt with insulator porceline and one MCB sp 6 Amp, 240 Volt and clamp system (screw less), shock proof safe IP-55, weather proof, rust, dust and water proof internally embedded gasket with provision for cable entry through gland alongwith MS clamps and mounting brackets as required at site complete all as specified and directed by Engr-in-Charge. |
| 52 | Supply and fixing OEM make 3phase Streetlight control panel max loadcapacity 12KW, incl all vital componants i.e65A TP Contactor,63A MCB TPN and digital24hrs switch etc.The panel should conforms to IS/IEC 60947-4-1 with Protection Degree IP- 54, making it suitable for outdoor installation. It should have extended wide band coil & FRLS (Fire retardant low smoke) internal wiring. In-built Short-Circuit Protection should be provided and complies with Class H Insulation complete all as specified and directed by Engr-in-Charge. |
| 53 | M&L for point wiring with single corePVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 4 Sq mm FRLS (Nominal area) drawn through existing PVC conduit concealed inwall, ceiling with GI saddles GI screws, rawlplugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal box powder coatedof suitable size with3 mm thicklaminated sheet coverfor mounting switch sockets and regulators and drawing continuous earth wire ofPVC insulated unsheathed 1100 Volts grade cable withstrandedcopper conductor of size 4 Sq mm (Nominal area) for AC complete complete all as specified and directed by Engr-in-Charge.Note : Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate. |
| 54 | M & L forindustrial type metal socket enclosure with 240 volt MCB 20 Amps, withmetal plug top complete all as specified by Engr-in-Charge, incl taking down old unserviceable one. |
| 55 | M&L for steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts nuts & screws as specified type 410 SP-55 (11.0 mtr long) erecting in position all as specified anddirected by Engr-in-Charge.Note : Excavation Earth work and foundation will be measured and paid seperately under relevent items. |
| 56 | Supply , laying , testing & CommissioningUG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm, 3.5 core,some cable shell be laid at new place withSuitable thimbles complete all as specified and directed by Engr-in-Charge |
| 57 | Description all as per serial item No 52 here-in-before but of size 120 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge. |
| 58 | Description all as per serial item No 52 here-in-before but of size 95 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge. |
| 59 | Description all as per serial item No 52 here-in-before but of size 70 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge. |
| 60 | Description all as per serial item No 52 here-in-before but of size 50 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge. |
| 61 | Description all as per serial item No 52 here-in-before but of size 35 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge. |
| 62 | Description all as per serial item No 52 here-in-before but of size 25 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge. |
| 63 | Description all as per serial item No 52 here-in-before but of size 16 Sqmm 4 core complete all as specified and directed by Engr-in-Charge. |
| 64 | Description all as per serial item No 52 here-in-before but of size 10 Sqmm 4 core complete all as specified and directed by Engr-in-Charge. |
| 65 | Description all as per serial item No 52 item No 50 here-in-before but of size 10 Sqmm 2 core complete all as specified and directed by Engr-in-Charge. |
| 66 | Supply,laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i,e. all type of joints, sockets,elbows,bends and end caps etc, ofsize 50mm outer dia and 38mm inner diacomplete allas specified and directed by Engr-in-Charge. |
| 67 | Description all as per serial item No 62 but of size 77mm outer dia and 76mm inner dia complete all as specified and directed by Engr-in-Charge. |
| 68 | Description all as per serial item No 62 but of size 90mm outer dia and 63mm inner dia complete all as specified and directed by Engr-in-Charge. |
| 69 | Description all as per serial item No 62 but of size 120mm outer dia and 103mm inner dia complete all as specified and directed by Engr-in-Charge. |
| 70 | Supply & fixing for replacement ofSPN 4way DBdouble doorcomplete with bracket and common earth terminal complete all as specified and directed by Engr-in-Charge. |
| 71 | Supply & fixing for multipurposeLED Spike light using COB LED as light source light, 5 wattdie cost aluminium bodyand IP66with corrosion-resistant finishes, powder coat paint ,suitable for Column lighting/Tree up lighting/Statue accentuation etc incl all fixing accessories complete all as specified and directed by Engr-in-Charge. |
| 72 | Supply & fixing for multipurpose 25WLED Up-down wall light using COB LED as light source light, die cost aluminium bodyand IP66with corrosion-resistant finishes, powder coat paint, suitable for wall decorative,incl all fixing accessories complete all as specified and directed by Engr-in-Charge.Make : Bajaj/CG/Philips/Havells |
| 73 | Supply, installation, testing and commissioning of split type AC 1.5 ton capacity 5 star rating with Rotary compressor, LED panel display, LCD remote control, sleep mode, Anti Bacteria filter, Auto restart complete,suitable for operation on electric driven single phase 230 volt AC 50 c/s and as per I.S. specification complete all as specified and directed. (a) One no cooling unit of 1.5 ton capacity wall mounting type(Copper Tubes) complete. (b) One condensing unit (Copper Tubes)of 1.5 ton capacity complete. (c)PVC pipe for draining out the condensated water (Qty asper the Site requirement) shall be included as quoted rates (d)Additional quantities of refrigerant if required at site shall be charged by the contractor without any extra cost.(e) Quantity of copper tube as per site requirement coverd with cable tray for complete the job shall be included in the quoted rate.(f)Condensing unit shall be installed with stand suitable place of the building as per instrutions of Engr in charge. Old UNSV BER Acs should be removed from existing site and same handover to MES store. |
| 74 | Supply, installation, testing and commissioning of split type AC 2.0 ton capacity, 5 star ratingwith Rotary compressor,LED panel display, LCD remote control, sleep mode, Anti Bacteria filter, Auto restart complete, suitable for operation on electric driven single phase 230 volt AC 50 c/sand as per I.S. specificationcomprising the following complete all as specified and directed. (a) One no cooling unit of 1.5 ton capacity wall mounting type(Copper Tubes) complete. (b) One condensing unit (Copper Tubes)of 1.5 ton capacity complete. (c)PVC pipe for draining out the condensated water (Qty asper the Site requirement) shall be included as quoted rates (d)Additional quantities of refrigerant if required at site shall be charged by the contractor without any extra cost.(e) Quantity of copper tube as per site requirement coverd with cable tray for complete the job shall be included in the quoted rate.(f)Condensing unit shall be installed with stand suitable place of the building as per instrutions of Engr in charge. Old UNSV BER Acs should be removed from existing site and same handover to MES store. |
| 75 | Supply and test only Voltage stabilizer (Copper wound) for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 9% and of capacity 5 KVA wall mounted type having digital LED display and intelligent time delay relay, over load protection and high/low voltage cut off relay Make:-V Guard/Blue star/Microtek/Volina |
| 76 | Supply and fixing for air conditioner drain cover kit size of 4x2\" (full set) containing (AC socket,Basic duct pipe, connector,diversion elbow,wall hole cover,Flexible duct pipe, Vertical elbow T-Joint, wall cap,Bridge Joint, Exit cover, foldable pipe) complete all as specified and directed by Engr-in-Charge. |