| 1 | Repair / maintenance of internal light fitting of any typelike tube lights / wall bracket light fittings / ceiling lights / bulk head light / mirror lights etc in its position, testing all the compenents / parts, wiring etc, identifying and replacing the defective components like tube rod, side holders, holders, lamps etc all as directed by Engr-in-charge. Note:(i)The rate against the above mentioned item is deemed for cost of labour only. (ii) Cost of spares like capacitor, lamp holder, connector, connection wire etc. replaced against above mentioned item will be measured & paid for separately under respective items of Sch \"A\" here-in-below.(iii)The contractor\"s representative will report to concerned JE E/M at 0900hrs daily to collect the list of defects and will submit the completion report on following daybefore 0900hrs to the JE E/M.(iv) The contractor shall rectify the defects and make the light fittings functional within 24 hours from the time the list of defective lights is handed over to him / his rep by the concerned JE E/M.In case the light fitting is not made functional for whatsoever reason within the specified time limit, an amount of Rs 100/- per such defective light fitting per day will be recovered from the amount due to him through RAR / Final Bill.The contractor shall engage separate team of technicians / repairer for each area as directed by engineer-in-charge..(v) The contractor shall maintain proper record of repair / maint in a binded compliant register and complaint slip books duly signed by the user and bringing out the details of spares replaced and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of light fittings with the concerned JE E/M against the supply only items here-in-below. |
| 2 | Supply only following spares for light fittings of branded make as mentioned in the list of make enclosed with Particular specifications for replacement :- (a)Spring loaded G13 side holders (set of 2) suitable for 36/40W FTL fitting |
| 3 | (b)Ditto all as per item No. 2 above but PVC / polycarbonate lamp holders batten/Angle type |
| 4 | S&F in replacement modular step type fan regulator 120W, 2 module complete all as specified and directed. |
| 5 | S&F in replacement modular switch piano type 10 amps one way one module complete all as specified and directed. |
| 6 | S&F in replacement modular switch piano type 20 amps one way one module with neon indicator complete all as specified and directed. |
| 7 | S&F in replacement modular Socket, 6A - 2/3 pin2 module complete all as specified and directed. |
| 8 | S&F in replacement modular Socket, 6/16A - 2/3 pin 2 module complete all as specified and directed. |
| 9 | S&F in replacement of 1 module Blanking plates complete all as specifed and directed |
| 10 | S&F in replacement modular Bell push, 10 Amp with neon indicator one module complete all as specified and directed. |
| 11 | S&F in replacement modular switch piano type 10 amps Two way one module complete all as specified and directed. |
| 12 | S & Fin replacement of switch piano flush type 5 Amps SP one way complete all as specified and directed. |
| 13 | S & Fin replacement of switch piano type 15 Amps SP one way complete all as specified and directed. |
| 14 | S & F inreplacement ofswitch socket combination 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and directed. |
| 15 | S & F inreplacement ofswitch socket combination 5/15 Amps flush mounted3/5 pin multi purpose complete all as specified and directed. |
| 16 | S&F inreplacement ofsocket 5/6 Amps flush mounted3 pin complete all as specified and directed. |
| 17 | S&F inreplacement ofsocket 5/15 Amps flush mounted3/5 pin multi purpose complete all as specified and directed. |
| 18 | S&F in replacement for ceiling rose, 2 to 3 terminals /PVC/Polycarbonate, isolated body complete all as specified and directed. . |
| 19 | M&L in replacment of fan regulator electronic steptype suitable for 1200/1400 mm sweep fan as per the sample provided by the complete all as specified and directed. |
| 20 | M&L in replacement of door bell AC 230 volts single phase ding dong type all as specified and directed. |
| 21 | M&L in replacement bell push, flush type 5 Amps all as specified and directed. |
| 22 | S & F inreplacement ofswitch socket combination with box 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and directed. |
| 23 | S & F inreplacement ofswitch socket combination with box 5/15 Amps flush mounted3/5 pin multi purpose complete all as specified and directed. |
| 24 | S& F PVC unbreakable surface boxesof size 4x4 complete all as specified and directed. |
| 25 | S& F PVC unbreakable surface boxes of size 6x6 complete all as specified and directed. . |
| 26 | S& F PVC unbreakable surface boxes of size 4x7 complete all as specified and directed. . |
| 27 | S& F PVC unbreakable surface boxes of size 6x8 complete all as specified and directed. . |
| 28 | S& F PVC unbreakable surface boxes of size 8x10 complete all as specified and directed. . |
| 29 | S&F in replacementfor white cover plate with frame 1 or 2 module complete all as specified and directed. |
| 30 | S&F in replacementfor white cover plate with frame 3 module complete all as specified and directed. |
| 31 | S&F in replacementfor white cover plate with frame 4 module complete all as specified and directed. |
| 32 | S&F in replacementfor white cover plate with frame 6 module complete all as specified and directed. |
| 33 | S&F in replacementfor white cover plate with frame 8 module complete all as specified and directed. |
| 34 | S&F in replacementfor white cover plate with frame 12 module complete all as specified and directed. |
| 35 | S& F in replacement PVC unbreakable surface boxes suitable for modular switches 1 or 2 module complete all as specified and directed. . |
| 36 | S& F in replacement PVC unbreakable surface boxes suitable for modular switches 3 module complete all as specified and directed. . |
| 37 | S& F in replacement PVC unbreakable surface boxes suitable for modular switches 4 module complete all as specified and directed. . |
| 38 | S& F in replacement PVC unbreakable surface boxes suitable for modular switches 6 module complete all as specified and directed. |
| 39 | S& F in replacement PVC unbreakable surface boxes suitable for modular switches 8 module. complete all as specified and directed. |
| 40 | S& F in replacement PVC unbreakable surface boxes suitable for modular switches 12 module complete all as specified and directed. |
| 41 | Taking down carefully copper/aluminium point wiring (light/fan/socket) including all accessories wire, casing caping/conduit, screws etc and making good the disturbed surfaces complete all as specified and directed. |
| 42 | M&L for point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metalic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for following :-(a) One light/Fan point controlled by one way switch 6 Amps 240 volts |
| 43 | (b) Ditto all as per item No. 42 above butOne 3 pin 6 Amps socket out let point on independent board. |
| 44 | (c)Ditto all as per item No. 42 above butOne 3 pin 6 Amps socket out let point on same board. |
| 45 | (d)Ditto all as per item No. 42 above butOne bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq mm size. |
| 46 | (e)Ditto all as per item No. 42 above butOne light point controlled by Two 2-way switches |
| 47 | M&L for point wiring with 2.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unseathed cable and including surface, Non metalic rigid PVC casing capping double lock type ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable size 2.5 sq mm copper conductor as earth wire to common earth dolly including PVC box , modular cover plate with frame suitable for 15 Amps socket and switch outlet power point independent circuit complete all as specified and directed. |
| 48 | M&L for securingloose wiring and repair to point wiring with necessary rigid non metalic PVC casing caping double lock type/ PVC conduit ISI marked of size not less than 25 mm inclusive all accessories complete as specified and directed. |
| 49 | S&F in replacement flexible conduit pipe ivory grey in colour of dia not less than 25 mm complete all as specified and directed. Make: As per sample approved by Engr-in-charge |
| 50 | Taking down carefully sub main wiring of any type and size and making good disturbed surfaces complete as directed. |
| 51 | M&L for sub main wiring with two single core PVC insulated FRLScables with stranded copper conductors 1.5 Sqmm , 1100 Volts grade in and including PVC Conduit/casing capingmedium grade not less than 25 mm complete with conduit accessories and copper cable 1.5 sqmm continuous earth wirecomplete all as specified and directed Note: Two runs of 1.5 Sqmm cable with 01 run of 1.5 Sqmm earth wire along with casing caping/conduit shall be measured as one RM |
| 52 | M&L for sub main wiring with two single core PVC insulated FRLScables with stranded copper conductors 2.5 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with conduit accessories and copper cable 2.5 sqmm continuous earth wirecomplete all as specified and directed Note: Two runs of 2.5 Sqmm cable with 01 run of 2.5 Sqmm earth wire along with casing caping/conduit shall be measured as one RM |
| 53 | M&L for sub main wiring with two single core PVC insulated FRLScables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with conduit accessories and copper cable 4 sqmm continuous earth wirecomplete all as specified and directed Note: Two runs of 04 Sqmm cable with 01 run of 4 Sqmm earth wire along with casing caping/conduit shall be measured as one RM |
| 54 | M&L for sub main wiring with two single core PVC insulated FRLScables with stranded copper conductors 6 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with accessories and copper cable 6 sqmm continuous earth wirecomplete all as specified and directed Note: Two runs of 06 Sqmm cable with 01 run of 6 Sqmm earth wire along with casing caping/conduit shall be measured as one RM |
| 55 | M&L for sub main wiring with two single core PVC insulated FRLScables with stranded copper conductors 10 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with accessories and copper cable 10 sqmm continuous earth wirecomplete all as specified and directed Note: Two runs of 10 Sqmm cable with 01 run of 10 Sqmm earth wire along with casing caping/conduit shall be measured as one RM |
| 56 | M&L for sub main wiring with Four single core PVC insulated FRLScables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with accessories and copper cable 4 sqmm continuous earth wirecomplete all as specified and directed Note: Four runs of 4 Sqmm cable with 01 run of 4 Sqmm earth wire along with casing caping/conduit shall be measured as one RM |
| 57 | M&L for sub main wiring with Four single core PVC insulated FRLScables with stranded copper conductors 6 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with accessories and copper cable 6 sqmm continuous earth wirecomplete all as specified and directed (Note: Four runs of 6 Sqmm cable with 01 run of 6 Sqmm earth wire along with casing caping/conduit shall be measured as one RM |
| 58 | S&F in replacement 1100 volts grade heavy duty service cable 4 Sqmm two core PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed. |
| 59 | S&F in replacement factory made epoxy powder coated Distribution Board TP & N 4way double door (VTPN MCCB DB ) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishescomplete all as specified and directed.Note:MCBs/ MCCBs will be measured and paid seperately under respective Sch A item in the schedule |
| 60 | S&F in replacement MCB DB 12 way SPN double door sheet metal enclosure factory made suitable for MCB DB\"s 240 voltswith 200 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as specified and directed.Note - MCBs will be measured & paid separately under respective item of sch A, if required to be replaced. |
| 61 | Dittto all as per item No 60 above but 08 way SPN DB (Double door) |
| 62 | Dittto all as per item no 60 above but 04 way SPN DB (Single door) |
| 63 | Dittto all as per item no 60 above but 02 way SPN DB (Single door) |
| 64 | S&F in repairs MCCB with rating of 100 Amps,415Volts 3pole with 16kA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu).MCCBshould be with suitable spreaders and phase barriers for each terminals complete all as specified and directed. |
| 65 | S&F in repairs MCCB with rating of 63 Amps,415Volts 3pole with 16kA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu).MCCBshould be with suitable spreaders and phase barriers for each terminals complete all as specified and directed.. |
| 66 | S&F in replacement of C Curve MCB SP 6-32 Amps working on 240 volts,50 Hz 10 KAcomplete all as specified and directed. |
| 67 | S&F in replacement of C Curve MCB DP 6-32 Amps working on 240 volts,50 Hz 10 KAcomplete all as specified and directed. |
| 68 | S&F in replacement of C Curve MCB SPN 40-63 Amps working on 240 volts, 50 HZ,10 KAcomplete all as specified and directed. |
| 69 | S&F in replacement of C Curve MCB TP 40-63 Amps working on 240 volts, 50 HZ,10 KAall as specified and directed. |
| 70 | Supply and fix in replacement of C Curve MCB TPN 40-63 Amps working on 240 volts, 50 HZ,10 KAcomplete all as specified and directed. |
| 71 | Taking down ceiling fan/exhaust fan of any sweep for servicing / repairing / maintenance, opening up, identifying and replacing the defective parts, cleaning, greasing,etc, reassembling and hanging up/fixing back at its original position, connecting up and testing complete all as directed.Note :Cost of spares such as capacitors, bearings etc will be measured and paid for separately under respective Item of sch A as supply only. |
| 72 | Supply only capacitor of 2.5/4 mfd for ceiling fan/exhaust fan complete all as specified and directed.. |
| 73 | Supply only bearing No.6201/6202/6203 or any other No matching to the existing size and suitable for exhaust fan/wall mounted fan complete all as specified and directed. |
| 74 | Disconnecting electric connectionand taking down carefullyExhaust fan of any type and size/sweep as described below, removing the burnt winding of fan motor rewinding with super enarneled copper winding wire of suitable gauge or of matching size to the exisiting wires including all insulating material such as insulation paper sleeve, tape, varnishing etc and reassembling, testing, transporting back to site and reflxing to original position all as directed by Engineer-in-charge for following :- (a) Exhaust fan of 300 mm sweep. |
| 75 | (b)Ditto all as per item No. 74 above but wall mounted fan of 400/600 mm sweep. |
| 76 | M&L for painting the exhaust fan ofany sweepwith two coats of synthentic enamel paint by rubbing/removing the old paint carefully without any damage to the fan or fan blades complete all as specified and directed. |
| 77 | Dismantling and removing rusted louvers (set of 4) suitable for 300 mm sweep exhaust fan supply and fix MS louvers duly painted gray coloured suitable for 300mm heavy duty exhaust fan alongwith four number mounting bracket with bolts, nuts washers etc complete all as specified and directed. |
| 78 | S&F in replacement of GI pipe ceiling fan down rod of 15 mm dia up to 1 mtr long for ceiling fan made out of 15 mm dia GI heavy grade pipe fixed on ceiling using suitableclamp including necessary new nut, bolt and washer complete all as specified and directed. |
| 79 | S&F in replacement sheet metal enclosures Single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 volts complete with all accessaries etc complete all as specified and directed. |
| 80 | S&F in replacement sheet metal enclosures Triple pole and earth encolsure with a three pin and earth plug withsocket complete with one triple pole MCB 32 Amps, 240 volts complete with all accessaries etc all as directed |
| 81 | S&F neon lamp indicator square/round type after taking out old incl taking down old one complete all as specified and directed.. |
| 82 | S&F in replacement plug top 3 pin, 15/16 amps, 230 volts, ISI marked heavy duty for geyser connection cord complete all as specified and directed.. |
| 83 | S&F in replacement plug top 3 pin, 5/6 amps, 230 volts, ISI marked complete all as specified and directed.. |
| 84 | S&F in replacement NRV valve of size 15mm dia of Brass complete all as specified and directed. |
| 85 | S&F in replacement PVC insulated cable 2 core stranded copper conductor 0.5 sqmm complete all as specified and directed. |
| 86 | S&F in replacement PVC insulated cable 2 core stranded copper conductor 1 sqmm complete all as specified and directed. |
| 87 | S&F in replacement PVC insulated cable 2 core stranded copper conductor 1.5 sqmm in and including PVC conduit pipe of dia not less than 25 mm complete all as specified and directed. |
| 88 | S&F in replacement PVC insulated round cable 3 core stranded copper conductor 2.5 sqmm as in connection cord of the geyser complete all as specified and directed. |
| 89 | S&F in replacement PVC insulated cable 3 core stranded copper conductor 4 sqmm in and including PVC conduit pipe of dia not less than 25 mm complete all as specified and directed. |
| 90 | S&F in replacement of earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc all as specified and directed |
| 91 | S&F in replacement of GI pipe bracket of 25 mm dia 1 mtr long bend to shape for street light fitting made out of 25 mm dia GI light grade pipe fixed on building/pole using suitable FI clamp including necessary new nut, bolt and washer complete all as specified and directed. |
| 92 | S&Fin replacement LED building security light fiitting 20 W, IP-65 protection made up of die cast alluminium housing with high power LED as lighting source and lens embeded PC cover having TOP opening seperate driver compartment complete all as specified and directedNote: Old security light should be deposited to MES store |
| 93 | S&F in replacement of 10watt,230V surface and wall mounted Inverter LED batten, automaticaily switched ON during a power cut and runs effiectively up to 3 Hrs,extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose complete all as specified and directed. |
| 94 | S&F in replacement of 20watt,230V surface and wall mounted Inverter LED batten, automaticaily switched ON during a power cut and runs effiectively up to 3 Hrs,extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose complete all as specified and directed. |
| 95 | S&F in replacement Decorative indoorWall Lamp with 7Wand connecting up with twin core twisted flexible copper conductor cable from ceiling rose complete all as specified and directed. |
| 96 | S&F in replacement 1x10watt, 230V surface mounted LED downlight with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency,including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified . Make - Luker Cat part no. LBKRDSL10/Havells INTEGRANEOSURFA CEDLS10WLED857S or equivalent make as mentioned at list of makes in PS |
| 97 | S&F in repairs Electronic driversuitable for 25/30 watts LED building security light fittings as per existing make complete all as specified and directed |
| 98 | S&F in repalcement recess mounted 2\" x 2\" LED Panel lights 40 W LED 5700K, 240Volts and glare free symmetrical illumination suitable for Armstrong/Grid ceiling, Environmental friendly, new generation, energy saving,high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. Note: The quoted price shall include the cost of Light and its driver.Make: Luker Cat Part: LKM2240 or equivalent make as mentioned at list makes in PS |
| 99 | S&F in repalcement recess type LED COB lights 12 Wwith ceiling cut out of Ø 92 mm Environmental friendly, energy saving, recess mounted downlighter withelectronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully all as specified and directed. Make: Luker cat part no. LCOB12N or equivalent make as mentioned at list makes in PS |
| 100 | Supply and fixing in repairs vertical Stationary type electric water heaterclosed/vented type , inner body made up of ms coated with glassline coating capacity 25 Litres suitable for 230 volts , single phase AC 50 HZ Supply withBEE Star (5 Star Rating) complete with Seven years warranty on tank and two year warranty on geyser including grouting with nut bolts/fastners of suitable sizecomplete all as specified and directed. Note: 02 nos fastners of suitable size for mounting geyser is to be provided separately for each geyser and the cost of same is deemed to be included in the quoted rate. |
| 101 | Disconnecting and taking down existing userviceable geyser of 25/50/100 ltrs capacity of any make/brand, taking it to civil workshop for repairing.Opening the geyser and dismanting all parts and taking out inner tank/container,removing dents making to shape including welding / brazing the leakage portion, filling the portion between inner tank and out casing of geyser with new glass wool heat insulating material . Reassembling and painting the outer casing of geyser with two coats of superior quality synthetic enameled paintand re- fixing to original place complete all as specified anddirected |
| 102 | S&F in replacement thermostat and cutout set electronic type, temperature adjustable from 0-80⁰C suitable for geyser of 25 ltrs capacity all as specified anddirected. |
| 103 | S&F in replacement thermostat temperature adjustable from 0-80⁰C suitable for geyser of 100 ltrs capacity all as specified anddirected. |
| 104 | S&F in replacement heating element of capacity 2 KW of any type and shape suitable for Existing 25 ltrs capacity geysers as per sample provided complete all as specified and directed. |
| 105 | S&F in replacement heating element of capacity 3 KW of any type and shape suitable for Existing 100 ltrs capacity geysers as per sample provided by Engr-in-Charge |
| 106 | S&F in replacement flow unit (inner pipe assembly) suitable for geyser of 25 ltrs capacity of any brand/make and for vertical/Horizontal type including rubber ring/gasket complete all as specified anddirected. |
| 107 | S&F in replacement metallic flexible hot water connection 600 mm long including necessary washers suitable for geysers of 25 ltr capacity complete all as specified and directed. |
| 108 | S & F in repair of Solar Water Heating System Flat Plate Collector type, size : (2.0 x 1.0) Mtr based on direct transfer of heat of capacity 100 Ltrs Per day with suitable electric backup of 2 KW complete all as specified and directed |
| 109 | M & L for cleaning the hot water insulated tank of 100 ltrs capacity of Solar Water Heating System Flat Plate Collector Type by removing the sludge /foreign material from the tank and recifying the fault of water leakages complete all as specified and directed. |
| 110 | M & L for cleaning the Glass of Solar Flat Plate Collector Panel of size (2.0 x 1.0) Mtr by removing the mud/algee/foreign materials from the panel on half yearly basis complete all as specified and directed. Note : If any damages occurred to the solar panel during this job, contractor shall be responsible to make good without any extra cost to the deptt. |
| 111 | Supply and install in replacement of Solar Flat Plate Collector Panel of size (2.0 x 1.0) Mtr, suitable /compatible to existing system complete all as specified and directed. |
| 112 | S & F in replacement of composite PEX-AL-PEX pipes as per ASTM F 128-2017 of size inner dia 15 mm and outer dia 20 mm, suitable/compatible to existing system complete all as specified and directed. |
| 113 | S & F in replacement of CPVC pipes of size outer dia 16 mm with all standard fittings such as suitable size of MS clamps, screws, hooks, Elbow, bends, tees etc complete all as specified and directed. |
| 114 | S & F in replacement of heating element of 3 KW capacity duly ISI marked, 1-ph, 240 volts suitable/compatible to existing solar heating system complete all as specified and directed. |
| 115 | S & F in replacement Brass/Gun Metal Butterfly gate valve of 15 mm dia, ISI marked, suitable/compatible to extisting system complete all as specified and directed. |
| 116 | S & F in replacement of SS pipe flange of 15 mm dia or suitable/compatible to existing solar Flat plate collector system including suitable size of nut bolts and washers etc complete all as specified and directed. |
| 117 | M & L for Glass of Solar Flat Plate Collector Panel of size (2.0 x 1.0) Mtr by removing the existing broken glass and cleaning before installing new complete all as specified and directed..Note : If any damages occurred to the solar panel during this job, contractor shall be responsible to make good without any extra cost to the deptt. |
| 118 | S&F in repairs 15mm bore bib taps, fancy type, cast chromium plated, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 119 | S & F in replacement of rubber gaskets 15 mm dia or suitable/compatible to existing solar Flat plate collector system complete all as specified and directed. |
| 120 | S&F electrical meter box compartmentalized design suitable for 4 x energy meter and 4 x Two way SPN DB, outdoor wall mounted type, weather proof fabricated out of not less than 2.0 mm thick CRCA sheet, powder coated in siemens grey colour, double door. The enclosure shall be front openable with locking arrangement and provided with 5 mm thick bakelite sheet for mounting the energy meters and MCB DB. The enclosure shall be provided with suitable size PVC cable glands for incoming and outgoing cables/wires. The overall size of the meter box should be as per site requirement complete with all accessories prewired twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.( For NCO Qtrs)Note: quoted rate shall deemed toincluding for disconnecting existing circuits from DB\"s and energy meter and same has been refixed in new meter box |