| 1 | S&F Recess mounted 2\" x 2\" LED Panel lights 40 W LED 6500K, 240Volts and glare free symmetrical illumination suitable for MOC HPLceiling, Environmental friendly, new generation, energy saving,high power LED as a light source with clear diffuser including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully complete all as specified and directed. Note: The quoted price shall include the cost of Light and its driver. |
| 2 | Supply and fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed |
| 3 | M&L forsub main wiring with two single core PVC insulated FRLSHcables with stranded copper conductors 2.5 Sqmm , 1100 Volts grade including of PVC casing Capping with /PVC conduit medium grade as required not less than 25 mm size with all fitting & other accessories and copper cable 2.5 sqmm continuous earth wirecomplete all as specified and directedNote: Two runs of 2.5 Sqmm cable with 01run of 2.5 Sqmm earth wire along with PVC casing caping/ PVC conduit medium grade shall be measured as one RM |
| 4 | M&L forsub main wiring with two single core PVC insulated FRLSHcables with stranded copper conductors 4.0 Sqmm , 1100 Volts grade including PVC casing Capping / PVC conduit medium grade as required not less than 25 mm size with all fitting & other accessories and copper cable 4.0 sqmm continuous earth wirecomplete all as specified and directed Note: Two runs of 4.0 Sqmm cable with 01run of 4.0 Sqmm earth wire along with PVC caping caping/ PVC conduit medium grade shall be measured as one RM |
| 5 | S&FMCB DB 8 way SPN Double door sheet metal enclosure factory made suitable for MCB DB\"s 240 volts,concealed in wall complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site complete all as specified and directed .Note - MCBs will be measured & paid separately under respective item of sch A, if required to be replaced. |
| 6 | S&F MCB SP 6 to 32 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing complete all as specified and directed. |
| 7 | Supply and fixMCB SPN 40 C Curve Amps working on 240 volts, 50 HZ,10 KAall as specified and directed. |
| 8 | S&F modular switch 1 way 10 A 1 module all as specified and directed |
| 9 | S&F Modular socket 6 A 2/3 Pin2 module all as specified and directed |
| 10 | S&F modular BLDC fan regulator, 2 module, suitable for ceiling fan of 1200/1400mm sweep all as specified and directed . |
| 11 | S&F modular switch 1 way 16 A 1 with indicator module all as specified and directed. |
| 12 | S&F Modular socket 6 A/16A 2/3 Pin2 module all as specified and directed |
| 13 | Supply and fixing factory made epoxy powder coated Distribution Board TP & N 4way double door (VTPN MCCB DB) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout flush to wall and making good disturbed surface and touch up with the same finishescomplete all as specified and directed. Note:MCBs/ MCCBs will be measured and paid seperately under respective Sch A item in the schedule |
| 14 | M&L for Earthing complete with galvanised iron earth plate electrode 600 x 600 x 6mm as earthing lead buried directly in ground vertically to depth not less than 2.25 mtr below GL with the top edge of the plate not less than 1.5 mtr from GL, connected to GI earth lead of 4.0mm dia, by means of bolts & nuts, to GI and connected to earthing test point all as shown in elecrical plate No. 3 of SSR Part-I of 2009* specified or indicated and testing on completion including excavation / earth work in any type of starta, PCC (1:3:6) type C1 earthing chamber pre cast slab 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 KG/sqm cast iron frame, funnel with wire mesh GI watering pipe of 20 mm bore medium grade and lugs with and including GI earth wire 4 mm dia with GI protection pipe of 15 mm medium grade 7.5 meter long etc complete tested on completion all as specified and directed.Note: a). Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. b). GI wire above 7.5m will be measured and paid seperately. |
| 15 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed |
| 16 | Supply and laying of UG LT cables XLPE insulated, PVC sheathed aluminium conductor multi stranded armoured heavy duty 1100 Volt grade cross sectional area 10 sqmm 4 core laid in trenches/ ducts/ along poles/through pipe under road etc with new aluminium lugs of cable size all as specified and directed |
| 17 | Supply and laying of UG LT cables XLPE insulated, PVC sheathed aluminium conductor multi stranded armoured heavy duty 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ ducts/ along poles/through pipe under road etc with new aluminium lugs of cable size all as specified and directed |
| 18 | M&L PVC insulated Copper conductor FRLS grade three core cable 2.5 sqmm, ISI markedfrom junction box tofitting ,multistranded all as specified and directed |
| 19 | Excavation in trenches in hard/dense soil n.exc 1.5 M wide and not exceeding 1.5 mts in depth in wide for laying of cables and n exc 1.5 mtr in depth and getting out incl dressing/trimming sides and levelling/grading and ramming of bottom of excavation complete all as specified and directed. |
| 20 | Returning and filling in, including spreading and well ramming in layers n exc 25 cm all as specified and directed . |
| 21 | Removing excavated surplus soilto a distance n exc 50 m anddepositing where directed at a level n exc 1.5 mtr above starting point complete all as specified and directed |
| 22 | Supply and laying in 40 x 32 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approval colour complete with fitting i.e.coupler,Tee,elbow clamp for cable protectioncomplete all as specified and directed |
| 23 | M&L PCC 1:3:6 type C-2 (using 40 mm size gradedstone aggregate) Cement concrete in foundations, filling and mass concrete complete all as specified and directed |
| 24 | M&L PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping of pole sand including formed work and demolition of existing coping complete all as specifed and directed |
| 25 | M&L for PCC 1:4:8 type D-2 (40 mm graded aggregate) Cement concrete in foundations, filling and mass concrete complete all as specified and directed |
| 26 | Supply, transport, errecting and fixing steel tubular swaged welded pole of over all height 9.0 m long complete type 410-SP-31 conforming to IS-2713 (Part I to III 1980 reaffm 2008with cast iron base plate, finial tapper plug cap, bolt, nut and washer etc., complete all as specified and directed.Note: (i)Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 m top of coping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer.(iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer and retro reflective tape of Red, Yellow and White color each of 2 inch wide fixed to the poles as directed(iv)Pole below ground shall be tarred by one coat(v) Poles shall be numbered and the rate for above items shall be deemed to be inclusive in the quoted rate. |
| 27 | S&F LED 48/50watt street light fiitting made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection incl completefixed to pole/wall with necessary MS clamp accessories complete all as specified and directed. |
| 28 | Supply and fixjunction box thermo plast (weather proof) IP 66,on street light poles made out of thermoplastic of size 300mm x 200 mm x 105 mm size withconnector for connecting incomming and outgoing of cableincluding 01 No of MCB DP 06 Amps to control the pole light circuit andMS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incomming, outgoing of cable Complete all as specified and directedMake Sintex Cat pat No GSJB-3020 or equivalent make mentioned at list of makes in PS |
| 29 | MCB DP 230 volts C curve 6 amps Complete all as specified and directed |
| 30 | S&F of digital timer switch distribution board, factory assembled in powder coated sheet steel enclosure, comprising of 40 Amps 3 Pole MCB, power contactor and 230V digital time switch for controlling LED/SV etc street lights ,including earth work for fixing Timer switch distribution Board and shall be provided 4 Nos 35x35x4mm thick angle iron supports of not less than each 0.6 mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement all as specified and directed |
| 31 | Material and labour for Tarmac bituminised road cutting by using suitable hydraulic road cutter for a width not exceeding 300 mm and depth 600 mm forlaying of 80 MM mediumgrade GI pipe incl refilling and making good with Tarmac/ PCCduly matching with the existing surface Complete all as specified and directedNote:1. Quoted rate shall be incl of 80 MM Gi pipe medium grade2. Quoted rate shall deemed to incl the cost of making good the disturbed surface. |
| 32 | S&F Vertical Mounting, 5 Star Rating type electric water heater, inner body made out ofEnamel Glassline coating Steel tank of capacity 25 Litres suitable for 230 volts , single phase AC 50 HZ,Power - 2000 Watt. + 5% - 10%, Max. Thermostate Temp. 75 ± 5 % Deg. C,Outer body PPGI sheet to IS:2082 (Part /1993) (reffirmed 2004) with latest amendments and having BEE Star (5 Star Rating) Warrenty - 2 year on product, 3 year on Heating Element and 7 yrs on Tank complete including grouting with nut bolts/fastners of suitable size complete all as specified and directed |
| 33 | S&F GI mesh flexi connection pipes 15 mm dia suitable for hot & cold water of length not less than 600 mm long with metallic nuts on both ends of pipe Complete all as specified and directed. |
| 34 | M&L for Cutting chases for concealed conduit Piping/ wiring, pinning in and making good to surface where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., cutting not exc 10 cm girth including 3 mm thick wall care putty on wall, making surface matching to adjacent surface all as specified and directed. |
| 35 | S&F Modular AC Box with 20 A DP MCB, with surface mounted Unbreakable Heavy Duty Plastic Enclosure including 1 nos ISI marked Plug Top and 1 nos 20 A DP modular MCB complete all as specified and directed. |
| 36 | S&F 15 mm bore GI tubing medium grade with all fittings such as tee, bend, joint etc. and fixed to wall or laid in floor complete all as specified and directed. |
| 37 | S&F 15 mm bore stop valves, fancy type, cast chromium plated, high pressure, screwed both ends for iron pipe or for union and fixed comple all as specified and directed. |
| 38 | S&F 15mm bore bib taps, fancy type, cast chromium plated, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 39 | M&L for cutting existing steel tubing for alteration or additions of 15 mm dia with all fittings complete all as specified and directed. |
| 40 | Suply & fixing 200 watt LED flood light luminaire warm white illumination with separate driver assemble boxwith secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66, with suitable Mounting structure as per site requirement complete all as specified and directed |
| 41 | Suply & fixing50 watt LED flood light luminairehaving green illumination with secondary optics made in pressure die cast housing and heat sink in aluminium extrusionwith in built driversand IP 66 Complete all as specified and directedNote for Sno 40&41 : (i) The luminaires are to be fixed on MS channel br drilling holes of suitable size incl suitable mounting structure/fixed on poles as reqd at site. (ii) The length of MS channel should not be less than 75 cm (iii)All Steel structure should be pained with two coats of synthetic enamel paint incl one coat of red oxide primer. (iv) All welding work reqd for fabrication and fixing of luminaires are incl . (v) Preparatory work as mentioned atnote(i) to (iv) are incl in unit rate of indvl item here in before. |
| 42 | M&L XLPE insulated, armoured heavy duty electric cable with aluminium multistrand conductor, 1100 volts grade, cross sectinal area 4 sqmm 4 core laid in wall,trenches road and polescomplete all as specified and directed |
| 43 | S & F PVC insulated copper conductor 3 core 1.5 sqmm forfrom busbar tofitting with PVC Conduit and accessories ,multistranded complete all as specified and directed. |
| 44 | S&F Plexo box 2 Module 230V, 5 HZ, IP-65 & IK-09 Class-II, weatherproof cabinets, door and cabinet fully reversible, removable chassis and faceplates, including weatherproof glands, rails qty-1 Nos, coppper fork type 100 A busbars as short link including end caps,complete all as specified and directed Make: Legrand Catpart No 601932 or equvaleint make mentioned at list of makes in PS |
| 45 | Supply and fixof C Curve MCB TPN 40 Amps working on 415 volts, 50 HZ,10 KAall as specified and directed . |
| 46 | S& F GI tubing light grade 40 mm dia ISI marked for cable laid in trenches,roads,drainand fixedon pole by flat ironclamps, nut,bolt,washers suitable size complete all as specified and directed. |
| 47 | S&FGI pipe bracket of 40 mm dia0.3 to 1.5mtr long bend to shape as required for flood light/ street light fitting light fitting made out of40 mm dia GI light grade pipe fixed using new FI clamp including necessary new nut, bolt and washergroutedwith flat iron base complete all as specified and directed |
| 48 | Supply and fix sheet metal enclosure with double pole MCB 20A and two pin and earth plug and socket complete with all accessories etc all as specified anddirected. |
| 49 | Supply and install Hi wall split type AC units indoor/outdoor complete with cordless remote control unit and with in built air ioniser invertortype compressor, 100% copper tubing of Indoor & Outdoor cooling & condenser unit respectively with CFC free gasfor better indoor air quality with 5 star rating and EER 3.2 of capacity 2.0 TR single phase including cabling work, insulation between indoor unit to outdoor unit and provision of MS Brackets for resting of outdoor units (where reqd) or making resting platform of outdoor unit by brick works Complete all as specified and directed |
| 50 | S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA. Complete all as specified and directed |
| 51 | M & L for consealed sub main wiring 2 x 4.0 Sqmm for phase and neural, 1 x 4.0 Sqmm for earth wire PVC insulated (heavy duty) 1100 volts grade, FRLSH, with single core copper conductor& including non metallic medium grade rigid PVC conduit,fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of stone concrete or slab walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, cutting not exceeding 10cm girth complete all as specified and directed.Note :-3 run of 4.0 Sqmm cablealongwith PVC conduit will be measured as one RM (from distribution board to metal clad switch socket pointnear AC). |
| 52 | S&F sheet metal enclosure with two pin and earth plug and socket complete, with one single pole MCB 20 Amp complete all specified and directed. |
| 53 | M&L for PVC pipe 20 mm dia heavy duty with all fittings and fixing accesssories such as coupler, lock nut, saddle, pipe hook and laid on floor (for drain line) complete all specified and directed. |
| 54 | M & L for making holes by core cutting machine on stone/concrete / brick walls.Dia of hole not exc.50mm and thickness of wall 50cm to 70cm for entry of suction and discharge pipes of AC and making good disturbed surfaces with cement morted and finally finished with plaster of paris and painted the disturbed surfaces with existing type of paint and tint Complete all as specified and directed |