| 1 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards /slabs / blankets, any thickness, including cover fillets complete all as specified and directed. |
| 2 | S&F 20mm thick 2nd class hardwood clean sawn boards or planks, width n exc. 25 cm complete all as specified and directed. |
| 3 | S&F 2nd class hardwoodPlain fillets. square, rectangular or triangular in section , clean sawn, secured with nails or brads fixed in repairs.exc 3 sq cm & n exc 6 sqcm complete all as specified and directed. |
| 4 | S&F 2nd class hardwoodPlain fillets. square, rectangular or triangular in section , clean sawn, secured with nails or brads fixed in repairs.exc 6 sq cm & n exc 13 sqcm complete all as specified and directed. |
| 5 | Dismantling timber scantling 40 Sqcm and over in section and at any position as in unframed work complete all as specified and directed. |
| 6 | M&L for IInd class hard wood in scantlingexc 40 Scm in area clean sawn for unframed work complete all as specified and directed. |
| 7 | M&L for fillets, bullnosed, splayed, chamfered or rounded on one edge or face clean sawn, secured with secret screws or brads exc 13 sq cm & n exc 25 sqcm etc complete all as specified and directed. |
| 8 | M&L for 12mm thick Plywood, grade BWP, type BB fixed with screws to timber frame work on wall etc complete all as specified and as directed. |
| 9 | Material and labour for 2-3 mm thick decorative Veneered, grade 1 (with BWR resin) with decorative face veneers on one faces; fixed with screws to timber frame work complete all as specified and directed. |
| 10 | M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along internal wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and directed. |
| 11 | M&L for preparing the old wooden surfaces of any description,with mechanical wall sander (having mechanical vacuummechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc or flaming polish which ever is suitable for site and fill the gap or crack with wood filler, POP or putty etc by removing latches / sliding door bolt and refixing the same in the door and apply one or more coats of french polishing till the desired finish is obtained complete all as specified and directed. |
| 12 | M&L for preparation of old treated wooden Surfaces of any description, over 10cm in width or girth, fill the gap or crack, hole with wood filler or POP, putty etc including cleaning andmake the surface smooth and applying Woodkeeper 1 K PU by Berger or equivalent etc till the surface became fine glosy finish complete all as specified and directed. |
| 13 | M&L for complete removing of old treatment and preparation of wooden surfaces and applying two coats of Synthetic enemal paint over a coat of pink primer etc complete all as spd and as directed. |
| 14 | M&Lfor 16 to 18 mm thick granite (of any type any colour) work (table rubbed 7 polished ) in window door cills/jambs, platformlike in cement morter (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shed with granite etc complete all as directed. |
| 15 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc laid beded & pointed any type of morter |
| 16 | Supply and fix powder coated (wooden finished colour) aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom andsideswithrequired EPDM rubber/ neoprene gasket etc., aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, chromium plated brass/ stainless steel screws complete as per architectural drawings all as specified and as directed. |
| 17 | Supply and fix 4mm thick frosted sheet glass / glass strip area n.exc. 0.5 sqm ordinary quality andglazing fixed to aluminium and wooden window / ventilator shutters / steel windows with glazing cllips and putty etc all as specified and as directed. |
| 18 | S&F, Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturs etc complete all as specified & directed. |
| 19 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified & directed. |
| 20 | Supply and fix including hacking out from wooden surfaces 4mm thick frosted sheet glass / glass strip area n.exc. 0.5 sqm ordinary quality andglazing fixed to aluminium and wooden window / ventilator shutters / steel windows with glazing cllips and putty etc all as specified and as directed. |
| 21 | S&F Framed work for framed chajja,ornamentlal grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 22 | S&F rolling Venition blinds with design on inner faceverticle type made out of fibre cloth fixed, to wall with necessary aluminium brackets, screws etc including aluminium frame for venilion blinds etc designas approved by GE complete all as specified and directed. |
| 23 | S&F wooden flooring with 22-23 mm kiln seasoned maple wooden planks (Grade-I) fixed over treated and dry Indian Pine wooden runners of size 70 x 38mm laid over existing sub base of floor @250mm c/c in one direction. The wooden planks to be jointed to each other with tongue and groove method and fixed to wooden runner and top plank to be nailed in 45 degree secret nailing using Angle cleat in another direction using flooring nailer. The wooden runners to be fixed on neoprene rubber cover of size 50 x 50 x 19/20 mm @300mm c/c by stappling with suitable pms/nails. The floor will be installed after placing vapour barrier of 150 micron on subbase of floor, after installation of top surface floor will be machine sanded and furnished with two coats imported non skid polyurethane lacquer material and design as per sample kept in GE office complete all as specified and directed.Note:(i) The quoted rate shall includes making in linesas per guide line of BWF.(ii) The quoted rate shall includes to carry out third party testingfrom FRI Dehradun / Siliguri for random sample pick after supplying of complete lot of material.(iii) The quoted rate shall include field test for moisture content in woods planks/runner by using moisture meter equipment to check results as per IS provisions.(iv) The third party testing of wooden planks and runners includes following tests as per IS provisions.(a) Indentification of woods.(b) Density of wood.(v) The quoted rate shall includes to treat the wooden runner at site with chloropyriphos 20% EC by diluting water as per IS provisions.(vi) The certification shall be produced for sal wood.(vii) Contractor shall carryout the work with OEM who having experience of wooden flooring work in any Govt organisation / PSU in last 5 years.(viii) The contractor shall visit the site and understand requirement as per sample kept in GE office before quoting the tender. |
| 24 | M&L for complete removal of existing treatment from wall to make the surface free from dust, loose paint and loose plaster by scrapping manually / mechanically as directed by engr-in-charge (nails, screws if any to be removed properly before scraping) complete all as specified and directed. |
| 25 | M&L for providing and applying water proof cement base putty of 1mm thick over prepared old plastered / old painted wall surface to prepare the surface even and smooth upto desired finishes by manually / mechanical means etc complete all as specified and directed. |
| 26 | M&L for one coat of acrylic water based interior grade primer @ 0.8 ltr (undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied on wall with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface for painting of subbsequent coats complete all as specified and directed. |
| 27 | M&L for applying two coats of oil bound distemper on wall using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper shall be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. |
| 28 | S&F antique / ornamental Stainless steel hevy duty Hinges, Aldrop, tower bolt, handles, latches, window / door stopper, sliding door bolt etc match to existing for doors, windows, ventilators & banister all as specified and as directed. Make : M/S J Errana, Shri Laxmi Industries (P) Ltd, Classic or equivalent |
| 29 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.. |
| 30 | M & L for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type ofsoil complete all as specified and directed. |
| 31 | M&L for Hardcore gauge n.exc 63mm of broken stone or boulders deposited, spread and levelled in layers n exc. 15 cm thick,, watered and well rammed to a true surface complete all as specified and directed. |
| 32 | Removing surplus spoilto a distance not exceeding50m and deposited where directed at a level not exceeding 1.50m from the starting point, complete all as specified and directed. |
| 33 | M & L for 75mm thick cement concrete type D2, 1:4:8 (Using 40mm size gradedstone aggregates) as in sub base including use of necessary form work etc complete all as specified and directed. |
| 34 | M & L for 100mm thick cement concrete type B-1,1:2:4 (using 20mm size graded stone aggregates) as in base including use of necessary form work etc complete all as specified and directed. |
| 35 | M &Lforforming expansion joints 100 mmdeep x 12 mm wide filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, grade A.complete all as specified and directed. |
| 36 | M &Lfor Forming Contraction (Dummy) joints 65mm deep x 10mm wide,filled with sealing compound.grade A.complete all as specified and directed. |
| 37 | Taking down exiting copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc as directed. |
| 38 | M&L for concealed point wiring in and includingstove enamelled steel conduit medium grade with the help of multi-strandedunsheathed FRLSH copper cable 1.5 sqmm 650/1100Vconforming IS:3419 -1988 adhereing to colour codeincluding earth wire of the size 1.5 Sqmm green colored with modular steel or cast iron terminal boxes and modular cover plates as required at site including making good the distrubed surfaces and matching it with existing surface for the following :- (a)One light/Fan point controlled by one way switch 6 Amps 240 volts |
| 39 | (b)Same as item 38 here in before but One 3 pin socket outlet, 5/6 Amps on the same board with other switches |
| 40 | (c)Same as item 38 here in before but One 3 pin socket outlet, 5/6 Amps, independent board |
| 41 | (d) M&L concealed point wiring with 4 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unseathed cable in and including PVC conduit not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLS cable size 4 sq mm copper conductor as earth wire to common earth dolly complete all as specified and directed. |
| 42 | S&F modular switch 1 way 10 A 1 module all as specified and directed |
| 43 | S&F Modular socket 6 A 2/3 Pin2 module all as specified and directed |
| 44 | S&F modular switch 1 way 16 A 1 with indicator module all as specified and directed |
| 45 | S&F Modular socket 6 A/16A 2/3 Pin2 module all as specified and directed |
| 46 | S&F in replacement for ceiling rose, 3 terminals /PVC/Polycarbonate, isolated body complete all as specified and directed. |
| 47 | S & F RJ-11 telephone socket with transparent shutter 2 module alongwith flush metal box 2 module and front cover plate 2 module complete all as specified and directed. |
| 48 | S &F for LAN RJ-45 Jack With Cat 6 socket UTP Catwith transparent shutter 1 module alongwith flush metal box 1 module and front cover plate 1 module complete all as specified and directed. |
| 49 | S&F ModularType C 2.1 A USB Charger all as specified and directed. |
| 50 | M&L for Provn ofPVC conduit for Telephone/TV/LAN/CCTVnot less than 25 mm with Cutting chases for concealed conduit wiring, pinning in and making good to surface where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., cutting not exc 10 cm girth including 3 mm thick wall care putty on wall, making surface matching to adjacent surface all as specified and directed. |
| 51 | Taking down exiting Telephone/TV/LAN/CCTV cable wiring completeand making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 52 | S&F in repalcement Reces mounted 2\" x 2\" LED Panel lights 40 W LED 6500K, 240Volts and glare free symmetrical illumination suitable for MOC HPLceiling, Environmental friendly, new generation, energy saving,high power LED as a light source with clear diffuser including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. Note: The quoted price shall include the cost of Light and its driver.Make: Luker -LKM2240LN5Y or equivalent make as mentioned at list of makes in PS |
| 53 | Taking down ceiling fan/Exhaust Fan, sealing cable end,dismantling blades and removing fan and blades to AGE E/M store complete all as specified and directed. |
| 54 | S & F Anchor Bolt on the RCC roof Drill holes at the marked locations using a masonry drill bit. Ensure the holes are deep enough to accommodate the entire length of the anchor bolts.Place the mounting bracket over the anchor bolts and secure it by tightening the nuts with a wrench. Ensure the bracket is firmly attached and level.Ensure all connections are secure and the fan is stable complete all as specified and directed.. |
| 55 | M&L for repalcing the down rod of ceiling fans with 5 feet GI ceiling fan hanging down rod with necessary clamp accessories complete all as specified and directed. |
| 56 | S & F Anchor Bolt on the RCC roof Drill holes at the marked locations using a masonry drill bit. Ensure the holes are deep enough to accommodate the entire length of the anchor bolts.Place the mounting bracket over the anchor bolts and secure it by tightening the nuts with a wrench. Ensure the bracket is firmly attached and level.Ensure all connections are secure and the fan is stable complete all as specified and directed.. |
| 57 | M&L for Cutting chases on wall /floor in pcc /stone wallsurface for concealed conduit wiring, pinning in and making good to surface where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., cutting not exc 10 cm girth including 3 mm thick wall care putty on wall, making surface matching to adjacent surface all as specified and directed. |
| 58 | Taking down exiting copper/aluminium sub main wiring complete for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 59 | M&L forconcealed sub main wiring with two single core PVC insulated FRLSHcables with stranded copper conductors 2.5 Sqmm , 1100 Volts grade in and including stove enamelled steel conduitmedium grade with all fitting & other accessories and copper cable 2.5 sqmm continuous earth wirecomplete all as specified and directed. Note: Two runs of 2.5 Sqmm cable with 01run of 2.5 Sqmm earth wire along with PVC conduit medium grade shall be measured as one RM |
| 60 | M&L forconcealed sub main wiring with two single core PVC insulated FRLSHcables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including stove enamelled steelconduit medium grade with all fitting & other accessories and copper cable 4 sqmm continuous earth wirecomplete all as specified and directed. Note: Two runs of 04 Sqmm cable with 01run of 4 Sqmm earth wire along with PVC conduit medium grade shall be measured as one RM |
| 61 | M&L forconcealed sub main wiring with two single core PVC insulated FRLSHcables with stranded copper conductors 6 Sqmm , 1100 Volts grade in and including stove enamelled steelconduit medium grade with all fitting & other accessories and copper cable 6 sqmm continuous earth wirecomplete all as specified and directed. Note: Two runs of 06 Sqmm cable with 01run of 6 Sqmm earth wire along with PVC conduit medium grade shall be measured as one RM |
| 62 | Supply and fix in replacement sheet metal enclosures single pole MCB 20 Amps with a two pin and earth plug and socket complete with all accessaries etc all as specified and directed. |
| 63 | S&F in replacement MCB DB 8 way SPN Double door sheet metal enclosure factory made suitable for MCB DB\"s 240 volts,concealed in wall complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site complete all as specified and directed.Note - MCBs will be measured & paid separately under respective item of sch A, if required to be replaced. |
| 64 | S&F in replacement MCB DB 4 way SPN Double door sheet metal enclosure factory made suitable for MCB DB\"s 240 volts,concealed in wall complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site complete all as specified and directed..Note - MCBs will be measured & paid separately under respective item of sch A, if required to be replaced. |
| 65 | Supply and fixing in replacement of factory made epoxy powder coated Distribution Board TP & N 4way double door (VTPN MCCB DB) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout flush to wall and making good disturbed surface and touch up with the same finishescomplete all as specified and directed. ( Note:MCBs/ MCCBs will be measured and paid seperately under respective Sch A item in the schedule |
| 66 | S&F MCB SP 6 to 32 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing complete all as specified and directed. |
| 67 | Supply and fix in replacement of C Curve MCB SPN 40 to 63 Amps working on 240 volts, 50 HZ,10 KAall as specified and directed. |
| 68 | S&F MCCB with rating of 125 Amps, 415 Volts 4 pole with 16 kA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu). MCCBshould be with suitable spreaders and phase barriers for each terminals complete all as specified and directed. |
| 69 | M&L for LED strip Lightwith colour temperature 6500k/3000k in 5 Mtr length wrapped around wooden panelling on the wall behind the dias and side wall complete all as specified and directed. |
| 70 | M&L in repalcement of Earthing complete with galvanised iron earth plate electrode 600 x 600 x 6mm as earthing lead buried directly in ground vertically to depth not less than 2.25 mtr below GL with the top edge of the plate not less than 1.5 mtr from GL, connected to GI earth lead of 4.0mm dia, by means of bolts & nuts, to GI and connected to earthing test point all as shown in elecrical plate No. 3 of SSR Part-I of 2009* specified or indicated and testing on completion including excavation / earth work in any type of starta, PCC (1:3:6) type C1 earthing chamber pre cast slab 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 KG/sqm cast iron frame, funnel with wire mesh GI watering pipe of 20 mm bore medium grade and lugs with and including GI earth wire 4 mm dia with GI protection pipe of 15 mm medium grade 7.5 meter long etc complete tested on completion all as specified and directed.Note: 1. Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI wire above 7.5m will be measured and paid seperately. |
| 71 | M&L n replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed |
| 72 | M&L for POP-UP boxes 6 moduleinstain less steel usingmetal flush mounted boxes and installation kit suitable for concrete or raised access floors or integrate directly into the furnitureequipped with push and slide locking system, incl necessary cutting on floor /.furnitureconfirming toIEC 60670-1,IEC 60670-23 and IES 60884-1 all as specified and directed |
| 73 | S&F wall mounting fans 400mm sweep,three speed settings,1350RPM,air flow 4200cubic metre/hr,aerodynimically design,rust free with thermal overload protector,55Watt,230V,50Hz all as specified and directed |