| 1 | S&F in replacement ,street light mounting bracket made out of 32 mm dia galvanized steel tubing medium grade 1.5 m long including bending if required as direct ,02 nos clamps made out of MS flat iron 25 x 3 mm of suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts and applying two coat of synthetic enameled grey paint after removing all dust & rust complete all as specified and directed |
| 2 | Supply and fixing in repairs surge protector, 10 KV, rated frequncy 48 HZ - 62 HZ,, 230 V suitable for 45W LED street light fitting complete all as specified and as directed. (Make : Bajaj / CG / Havells /Philips) |
| 3 | Supply and fixing in repairs surge protector, 10 KV, rated frequncy 48 HZ - 62 HZ,, 230 V suitable for 60W LED street light fitting complete all as specified and as directed. (Make : Bajaj / CG / Havells/Philips) |
| 4 | Supply and fixing in repairs surge protector, 10 KV, rated frequncy 48 HZ - 62 HZ,, 230 V suitable for 70W LED street light fitting complete all as specified and as directed.(Make : Bajaj / CG / Havells/Philips) |
| 5 | S&F in repairs surge protector, 10 KV, rated frequncy 48 HZ - 62 HZ,, 230 V suitable for 90W LED street light fitting complete all as specified and as directed.( Make : Bajaj / CG / Havells/Philips) |
| 6 | S&F in repairs surge protector, 10 KV, rated frequncy 48 HZ - 62 HZ,, 230 V suitable for 120W LED street light fitting complete all as specified and as directed.( Make : Bajaj / CG / Havells/Surya) |
| 7 | S&F in repairs drivers for LED street light 120W, complete all as specified and as directed.(Make : Bajaj / CG / Havells /Philips) |
| 8 | S&F in repairs drivers for LED street light 90W complete all as specified and as directed. (Make : Bajaj / CG / Havells /Philips) |
| 9 | S&F in repairs drivers for LED street light 70W complete all as specified and as directed. (Make : Bajaj / CG / Havells /Philips) |
| 10 | S&F in repairs drivers for LED street light 60W complete all as specified and as directed. (Make : Bajaj / CG / Havells /Philips) |
| 11 | S&F in repairs drivers for LED street light 45W complete all as specified and as directed. (Make : Bajaj / CG / Havells /Philips) |
| 12 | S&F in repairs drivers for LED street light 36W complete all as specified and as directed. (Make : Bajaj / CG / Havells /Philips) |
| 13 | S&F in repairs drivers for LED street light 25W complete all as specified and as directed. (Make : Bajaj / CG / Havells /Philips) |
| 14 | M&L for taking down old unserviceable and supply & lay / passing through pipes cable PVC insulted & PVC unsheathed 650 / 1100 Volt Grade As per IS 694 multistranded copper conductor of size 3 core 1.5 Sq mm. for interconnection of cable looping box to street light fitting/post top lantern / security light etc complete all as specified and as directed. |
| 15 | M&L for taking down old unserviceable and supply & lay / passing through pipes cable PVC insulted & PVC unsheathed 650 / 1100 Volt Grade As per IS 694 multistranded copper conductor of size 3 core 2.5 Sq mm. for interconnection of cable looping box to street light fitting/post top lantern / security light etc complete all as specified and as directed. |
| 16 | S&F in repair of Loop in loop out box of FRP made with IP 65 protection of thermoplasic circuit breaker boxes with metric knockouts for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as bus terminals for cable with necessary fixing arrangemets and with cable glands, etc complete all as specified and as directed. |
| 17 | S&F in replacement ofnon metallic 20 mm dia PVC conduit inclusive of boxes (junction/terminal) inclusive of all tees, bends, elbows, reducers, bell mounth tube ends and fixing accessories such couplers, lock nuts, saddles, pipe hooks, fixing clamps etc complete all as specified and as directed. |
| 18 | S&F in repairs 70 Watt LED street light made up of pressure die cast housing with pinnacle Plus LED street light made up of preesure die cast aluminium housing with integrated poly carbonate lense, high power ceramic LEDs with IP66 protection, with all fittings and LED bulb complete all as specified and as directed. |
| 19 | S&F in repairs 120 Watt LED flood light made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection, with all fittings and LED bulb complete all as specified and as directed. |
| 20 | S&F in repairs 25 W LED security light fittingmade up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optics with IP66 protection with all accessoriescomplete all as specified and as directed. |
| 21 | S&F in repairs 45 W LED security light fitting made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optics with IP66 protection with all accessoriescomplete all as specified and as directed. |
| 22 | S&F post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp completeincluding taking down old light fitting, complete all as specified and as directed. |
| 23 | S&F post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp completeincluding taking down old light fitting, complete all as specified. |
| 24 | S&F in repair synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed. |
| 25 | S&F in repair synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed. |
| 26 | S&F in repair20 W LED Master tube light suitable for flame proof/ weather proof wellglass lightfitting complete all as specified and as directed. |
| 27 | S&F in repairLED lamp 20 Watt. Suitable for flame proof/ weather proof wellglass lightfitting complete all as specified and as directed. |
| 28 | S&F in repairLED lamp 9 Watt. Suitable for flame proof/ weather proof wellglass lightfitting complete all as specified and as directed. |
| 29 | S&F in repair porcelin holder suitable for led flame proof lamp fitting. complete all as specified and as directed. |
| 30 | S&F in repairSelector knob for flame proof switchesall as specified and as directed. |
| 31 | S&F in repairFlame proof direct entry typerotary switch singlepole on & OFF rotary motion switch in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 230Volts 10 Amps, AC ON/OFF switch operated externally by Knob having 02 Nos of M-20 cable entries, earthing terminals suitable for mounting on Wall/Steel structure etc complete all as specified and directed |
| 32 | Supply and fixing in repair flame proof/ weather proof wellglass LED lightfitting including tube suitable for 1x18wattbody made out of aluminium alloy LM-6 epoxy painted with wire guard, mirror optic reflector LED as per IS 13947body made out of aluminium alloy LM-6 epoxy painted with guard, reflector, flameproof clear glass along complete all accessories prewired CMRI certified and hardware in high tensile with corrosive epoxy grey shade paint fixed to wall/ceiling including flameproof flexible wire from fitting to terminal point, complete all as specified and as directed. |
| 33 | Supply and fixing in repair flame proof/ weather proof wellglass LED lightfitting suitable for 45watt LED as per IS 13947body made out of aluminium alloy LM-6 epoxy painted with guard ,reflector, flameproof clear glass along complete all accessories prewired CMRI certified and hardware in high tensile with corrosive epoxy grey shade paint fixed to wall/ceiling including flameproof flexible wire from fitting to terminal point complete all as specified and directed. |
| 34 | S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed. |
| 35 | S&F in repair MCB SP 6 to 32 Amps, 10 KA rating, \" C\" curve all as specified and directed |
| 36 | S&F in repair MCB SPN 32 Amps, 10 KA rating, \" C\" curve complete all as specified and directed |
| 37 | S&F in repair MCB TPN 63 Amps, 10 KA rating, \" C\" curve complete all as specified and directed |
| 38 | M&L forpainting of steel LT Poles at site and applying two coats of aluminium paint over a coat of reD oxide primer after removing all dust & rust and paint shall confirm to IS-2032 complete all as specified and directed. |
| 39 | M&L forpainting and Preperation of surface of RCC LT poles and painting with two coats synthetic enamel paint upto 1.0 meter height in black and white colour alternate strips each of 10cm wide including two coats of alluminium paint to cross arms/street light bracket/clamps and D clamps mounted on the pole after removing all dust & rust and paint shall confirm to IS-2032 complete all as specified and directed. |
| 40 | M&L for Surface dressing not exc 15 cm deep and 2.5 X 2.5 meter surrounding area of street light pole / stay / stay pole/HT poleincluding cutting and cleaning away grass, bushes, small plant, vegetable shrubs, bushes of under roots all as specified and directed. |
| 41 | M&L for earthing complete with galvanised steel earth plate electrode of size 60 cm x60 cm x 6.0mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge not less than 1.5 m below ground level,connected to galvanisedIron wire 4 mm dia by means of bolts, nuts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 5 of SSR part I, connected to earth test point all as specified or indicated complete with Excavation, earth work, PCC 1:3:6 pit with RCC M25 (design mix) cover 54cm x 54cm x 50 mm thick reinforced with hard drawn steel wire fabric weighing exceeding 4 Kg/Sqmwith suitable handle made of 10mm dia MS bar, 20 mm bore GI tubing medium grade for watering pipe, 15 mm bore upto 7.5 mtrs medium grade GI pipe for protection of earth lead, test point, GI funnel with 4 mm wire mesh all as directed and specified and testing on completion. |
| 42 | M&L for earthing complete with galvanised steel earth plate electrode of size 60 cm x60 cm x 6mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge not less than 1.5 m below ground level,connected to GI flat of size 32 X 6mmby means of bolts, nuts, check nuts, washers of GI or steel all as shown in electrical plate No 3 of SSR part I, connected to earth test point complete with Excavation, earth work, PCC 1:3:6 pit with RCC M-25 (design mix) cover 54cm x 54cm x 50mm thickreinforced with hard drawn steel wire fabric weighing exceeding 4 Kg/Sqmwith suitable handle made of 10mm dia MS bar, 20 mm bore GI tubing medium grade for watering pipe, 40 mm bore upto 7.5 mtrs light grade GI pipe for protection of earth lead, test point, GI funnel with 4 mm wire mesh all as directed and testing on completion. |
| 43 | Supply and fixing in repair street contactor, AC 240V fixed in street light panel board including necessary copper wire etc., Capacity 50 Amp complete all as specified and as directed.(Make: Model No LC1D329 of C&S equivalent in Indo Assian /L&T/CG) |
| 44 | S&F in repair Battery short tubular 12V of capacity 150 Ah with water level indicator complete all as specified and directed. (Make : Cat No RC1800ST OF Luminous or equivalent in Exide/Amaron) |
| 45 | S&F in repairs 24Watt LED solar street light fitting fixed to existing pole complete all as specified and directed.(Make: CG/Surya /Bajaj / Philips / Havells) |
| 46 | Supply and fixing in repair street light timer switch, Digital type, fixed in street light timer switch panel board including necessary copper wire etc., Capacity 16 -32 Amp complete all as specified and as directed.(Make: Indo Assian/L&T/CG) |
| 47 | S&F in repair Cable termination, heat shrinkable type Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through joint kit, outdoor type with jointing material and accessories suitable for for aluminum conductor cable of size 3.5 core x 10 to 16 sq.mm complete all as specified and directed. |
| 48 | S&F in repair Cable termination, heat shrinkable type Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through joint kit, outdoor type with jointing material and accessories suitable for for aluminum conductor cable of size 3.5 core x 25 to 50 sq.mm, fixed in repair, including testing after jointing, complete all as specified. |
| 49 | S&F in repair Cable termination, heat shrinkable type Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through joint kit, outdoor type with jointing material and accessories suitable for for aluminum conductor cable of size 3.5 core x 70 to 95 sq.mm, fixed in repair, including testing after jointing, complete all as specified. |
| 50 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of size 10 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspention wire, one twin core cable flat or circular complete all as specified and directed. |
| 51 | Supplying and fixing 1100 volts grade heavy duty cable Twin core16 Sqmmsize PVC insulated aluminium conductor, served with innersheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular as in replacement complete all as specified and as directed |
| 52 | Trimming/ cutting/prooningofthetreebranches / busheswhichfallswithin aclear distance of 3 meterfromall sides from theHT / LT over head conductor& within line of conductors,and shifting wasteto nearby waste depot & cleaning area complete all as specified and directed.(Note :- Horizontal distance of tree touching to the over head lines shall be measured forthepurpose ofpayment) |
| 53 | Demolition of cement concrete of any description and in any position complete all as specified and as directed |
| 54 | M&L for Plain cement concrete (1:2:4) type B1 using 20mm graded crushed stone aggregate in coping of pole, concrete base work, protection of cable complete all as specified. |
| 55 | S&F in repair switch paino,flush type,single pole,one way, 5/6 Amp, white, complete all as specified. |
| 56 | S&F in repair bell push, 5Amp, 230Volt, white, complete all as specified. |
| 57 | S&F in repair bell electric, ding dong type, AC 230 Volt, complete all as specified. |
| 58 | S&F in repair switch socket combination 2 pin & 3 pin 5Amp,240 volt, white, multipurpose complete all as specified and directed. |
| 59 | S&F in repair switch socket combination 2in 1 type, 3 pin 5 / 15Amp,240 Volt, white, multipurpose, complete all as specified and directed. |
| 60 | S&F in repair Fan regulator, electronic step typefor ceiling fan of any sweep, complete all as specified and directed. |
| 61 | S&F in repairLED light fitting 18 watts with and including LED tube rod 4 feet long suitable for single phase 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 62 | S&F in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 63 | S&F in repair Lamp holder (Angle type), PVC/ Polycarbonate type with cord grip, suitable for any type of fitting, fixed as in repair, complete all as specified and directed. |
| 64 | Supply & lay / passing through pipes in repair cable Heat Resistant Flame Retardant HRFR PVC Insulated Industrial Cables Single Core HRFR PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts Conforming to IS: 694 1.5 Sq mm complete all as specified and directed. |
| 65 | Supply & lay / passing through pipes in repair cableHeat Resistant Flame Retardant HRFR PVC Insulated Industrial Cables Single Core HRFR PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts Conforming to IS: 694 2.5 Sq mm complete all as specified and directed. |
| 66 | S&F in repair 9 watt LED Lamp, 220-240 volt AC 50Hz, energy saving type complete all as specified and directed |
| 67 | S&F in repair switch socket combination 2 pin & 3 pin 5 Amp with box,240 volt, white, multipurpose, complete all as specified. |
| 68 | S&F in repair switch socket combination 2in 1 type, 5 pin 5 / 15 Amp with box,240 Volt, white, multipurpose, complete all as specified and directed. |
| 69 | S & F in repair Modular type Metal Flush box 8 module complete all as specified and directed. |
| 70 | S & F in repair Modular type Metal Flush box 4 module complete all as specified and directed. |
| 71 | S & F in repair Modular type Metal Flush box 3 module complete all as specified and directed. |
| 72 | S & F in repair Modular type Metal Flush box 2 module complete all as specified and directed. |
| 73 | S&F in repair Modular White cover plate with frame 8 module complete all as specified and directed. |
| 74 | S&F in repair Modular White cover plate with frame 4 module complete all as specified and directed. |
| 75 | S&F in repair Modular White cover plate with frame 3 module complete all as specified and directed. |
| 76 | S&F in repair Modular White cover plate with frame 2 module complete all as specified and directed. |
| 77 | S&Fin repairModular Switch 1 way 6 A, 1 module complete all as specified and directed. |
| 78 | S&F in repair Modular Switch 1 way 16 A, 1 module complete all as specified and directed. |
| 79 | S&F in repair Modular Socket 6 A, 5 pin combined 2 module complete all as specified and directed. |
| 80 | S&F in repair Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module complete all as specified and directed. |
| 81 | S&F in repair Modular Fan step regulator, 120 watt, 2 module complete all as specified and directed. |
| 82 | S&F in repair Ceiling Rose, three phase, PVC/ Polycarbonate isolated body, complete all as specified and directed. |
| 83 | M&L for sub main wiring with 2 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm as earth continuity conductor drawn through and including PVC conduit (medium grade) of suitable size, surface type complete all as specified and directed.(NOTE : Three runs of single core 2.50 sqmm cable & one run of PVC conduit shall be measured as one unit) |
| 84 | M&L for sub main wiring with 2 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and including PVC conduit (medium grade) of suitable size, complete all as specified and directed.(NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC conduit shall be measured as one unit) |
| 85 | M&L for sub main wiring with 2 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through and including PVC conduit (medium grade) of suitable size, surface type complete all as specified and directed.(NOTE : Three runs of single core 6.0 sqmm cable & one run of PVC conduit shall be measured as one unit) |
| 86 | M&L for sub main wiring with 2 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and including PVC conduit (medium grade) of suitable size, surface type complete all as specified and directed.(NOTE : Three runs of single core 10 sqmm cable & one run of PVC conduit shall be measured as one unit) |
| 87 | S&F in repair MCB TPN DB, IP 43 protection, double door, 415 volts, 4 waywith 200 Amps copper bus bar for each phase complete all as specified and directed. |
| 88 | S&F in repair Double Door, Sheet Metal Enclosure for DBs, for mounting of MCB for 240 Volts, 8 way, with 200 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. |
| 89 | S&F in repair Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 12 way, with 200 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. |
| 90 | S&F in repair Double Door, Sheet Metal Enclosure for DBsfor mounting of MCB for 240 Volts, 4 way, with 200 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. |
| 91 | S&F in repair MCB SP 6 to 32 Amps, 10 KA rating, \" B\" curve all as specified and directed |
| 92 | S&F in repair MCB SPN 32 Amps, 10 KA rating, \" B\" curve complete all as specified and directed |
| 93 | S&F in repair MCB TPN 63 Amps, 10 KA rating, \" B\" curve complete all as specified and directed |