| 1 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed. |
| 2 | Dismantling timber scantlings 40sqcm and over in section, in any position complete all as specified and as directed. |
| 3 | Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section |
| 4 | Dismantling old unserviceable wrought iron or mild steel work of any description complete all as specified and as directed. |
| 5 | M&L for Mild steel work in tubular trusses, purlins, vetical posts including special shaped washer, angle cleats, fish plates, gusset plates, base/ bearing plates, bolts and nuts etc. complete using ERW or induction butt welded tubes conforming to 1161-1979 grade st 240 complete all as specified and as directed. |
| 6 | S&F 0.50mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet (AZ 150)of any colour having tensile strength of 550 Mpa as per IS 15965: 2012 in roof covering fixed with self tapping screws complete all as specified and as directed. |
| 7 | S&F 0.50mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet (AZ 150) of any colour having tensile strength of 550 Mpa as per IS 15965: 2012 in cladding to wall etc, fixed with self tapping screws complete all as specified and as directed. |
| 8 | M&L for providing cement concrete type B0 1:2:4 (using 12.5mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed. |
| 9 | Dismantling wall and ceiling boards (fiber, pulp, insulation, etc) or insulation board/slabs/ blankets, any thickness, including cover fillets. Complete all as specified and as directed. |
| 10 | Providing and fixing false ceiling with semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles at all heights with GRG (Glass fibre reinforced Gypsum) False ceiling tiles of size 595x595mm of approved texture,design and patterns having moisture content less than 2%, humidity resistance of 99%,NRCO .50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part-4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @120 grams per sqm (including both sides) comprising of main T runnersof size 15x32mm of length 3000mm ,cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600mm to form a grid module of size 600x600mm,suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm)i.e. 50 mm long ,8mm outer diameter M-6dash fasteners ,6mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2mm. Galvanized iron perimeter wall angle of size 24x24x0.40 mm of length 3000mm to be fixed on periphery wall /partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall screws. The work shall be carried out as per specifications,drawing and as per directions of Engineer in charge. |
| 11 | Demolition of reinforced concrete (cutting reinforcementas required to facilitate demolation of roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work all as specified. |
| 12 | S&F MS Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) |
| 13 | M&L for 50mm thick sand stone slab set and jointed over supports as in chajjas of ground and first floor\"s over windows, doors etc and jointed in cement mortar 1:4 complete all as specified and as directed. |
| 14 | M&L for 25 mm average thick PCC 1:2:4 type B0 (using 12.5 mm grd stone agg) in floors/paddingfinishing the surface even and smooth with out using extra cement. |
| 15 | Demolition of brick work or stone boulder masonary built in cement mortar including all quoins arches pillars etc. but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and as directed. |
| 16 | M&L for Brick work with with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 17 | M&L for light shade double charged vitrified tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchl aidover and including 15mm thick screed bed in cement mortar 1:6including dismantling of Old U/s tiles,hearth etc.complete all as specified and directed. |
| 18 | M&L forcoloured Glazed ceramic tiles on vertical surface 600x300x7-8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match fixed over and including 10 mm thick backing coat of cement mortar in 1:4including dismantling of Old U/s tiles,hearth etc.complete all as specified and directed. |
| 19 | M&L for 16-18 mm thick Granite slab work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like laid over and including 20mm thick screed bed in cement mortar 1:4 and pointing in white cement (1:2 )using marble dust with admixture of pigment to match with shade of granite, including rounded/half rounded edge and providing hole for gas pipe in pre-cast slab as well as in granite slab of cooking platformincluding dismantling of Old U/s stone slabs and tilesetc.complete all as specified and directed. |
| 20 | Taking down cement plaster on brick or stone walls,concrete surface etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed. |
| 21 | M&L rendering 15mm thick on fair face of brick work/concrete in CM 1:4 and finishing surface even and fair by mixing liquid water proofing compound as per manufacturers instructions complete all as specified and as directed.Note :- Liquid WPC shall be measured & paid seprately under relevant item of this BOQ. |
| 22 | Supply only liquid water proofing compound hydroseal-W+ /Dr Fixit or eqivalent (for plaster hardening, to contol efflorescence & fungal growth) as approved by Engineer-in-charge. |
| 23 | M&L for rendering 15 mm thick on other than fair faces brick wall or concrete surface in cement mortar 1:6 finished even & smooth without using extra cement complete all as specified and as directed. |
| 24 | M&L for preparation of new wall surfaces and applying one coat of alkali resistant priming paint on walls complete all as specified. |
| 25 | M&L for applying two coats of exterior emulsion exterior paint,Apex of Asian Paints or equivalent as approved complete all as specified.. |
| 26 | M&L for preparation of new plastered surface of wall and applying two coats of Oil Bound Distemper over and including one coat of alkali resistant primer on wall complete all as specified and directed by Engineer-in-Charge. |
| 27 | Taking down Chowkhats or frames with shutter without taking off shutters from the frames not exc. 1.5 sqm each complete all as specified and as directed. |
| 28 | Taking down Chowkhats or frames with shutter without taking off shutters from the frames exc. 1.5 sqm but n exc 4 Sqm each complete all as specified and as directed. |
| 29 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 30 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 31 | S&F 5 mm thick sheet glass, ordinary quality and fixing with rubber beading area n exc. 0.5 square metre in each pane etc complete all as specified and as directed. |
| 32 | S&F Pressed steel frames of size 105x60 mm made out of 1.25mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., with one shop coat of red oxide primer complete as specified and as directed. |
| 33 | S&F Pressed steel frames of size 125x60 mm made out of 1.25mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.with one shop coat of red oxide primer complete as specified and as directed. |
| 34 | M&L for cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in bed blocks for fixing hold fasts and filling of chowkhats etc complete all as specified and as directed. |
| 35 | M&L for prepration of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over primed surface complete all as specified and as directed. |
| 36 | S&F factory made 35 mm thick 2nd class Hard Wood factory made glazed and skeleton shutters open rebated and prepared to receive glass, gauze, etc without sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters asspecified in SSR Part-1 section 8 clause 8.24(a) complete all as specified and as directed. |
| 37 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as spicified and as directed. |
| 38 | S&F 30 mm thick factory made flushshutters, solid core construction withblock board core and plywood face panel veneer type on both side complete all as specified and as directed. |
| 39 | S&F 250 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed. |
| 40 | S&F aluminium anodized barrel tower bolts 200 mm length of bolt of extruded section and fixed complete all as specified and as directed. |
| 41 | S&FExtruded aluminium handles of size 150 mm, fabricated type anodised complete all as specified and as directed. |
| 42 | S&F MS Framed work such as grills gratings, door and cooler stand, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars and similar work confirming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 43 | Taking down aluminium shutters and dismantiling stiles and rails including glass panes/particle board carefully, Refabricating and refixing in frame position using all old material including neoprene replacement of required packing, cleats, screws complete all as specified and as directed |
| 44 | S&F in repair25 mm dia stainless steel drapery rod cut to size and fixed in position including end caps, roller and brackets fixed to wall complete all as specified and as directed. |
| 45 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground |
| 46 | S&F MS work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as specified and as directed. |
| 47 | M&L cement concrete type C-1 (1:3:6) 20mm graded stone aggregate as in bed blocks for fixing posts etc .all as specified. |
| 48 | Dismantling galvanised 2 strand, steel barbed wire in fencing. |
| 49 | S&F Galvanised 2 strand steel barbedwire 2.24mm dia barbed with 2mm barbs at 75mm spacing all as specified fixed in repair. |
| 50 | Supply and fix galvanised punched type concertina coil of loop dia 450 mm (dia of coil when unstretched) fixed to existing angle post strut and tying at three places ie two bottom & one at top with 3.15 mm dia galvanised mild steel wire all as specified and directed by Engineer in Charge. |
| 51 | M&L for Preparing new steel surface of any description over 10cm in width or girth and applying two coats of synthetic enamel painT over a coat of red oxide primer. |
| 52 | M&L for preparation of new wooden surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 53 | M&L for 25 mm average thick PCC 1:2:4 type B0 (using 12.5 mm grd stone agg) in floors/paddingfinishing the surface even and smooth with out using extra cement. |
| 54 | S&F PVC Wall lining consisting Hollow wall lining consisting of 10 mm thick printed PVC sheet of size 300x3010mm fixed to wall with giitites and screws complete all as specified and as directed. |
| 55 | S&F 2mm thick PVC sheet fillet of 35mm wide for panelling work inclusive of fixing on to wall and to edges of doors and windows all as specified and as directed. |
| 56 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil. |
| 57 | M&L for cement concrete type D2 1:4:8 using 40 mm graded aggregate as in foundation filling and mass concrete. |
| 58 | M&L for cement concrete Type B2 1:3:6 using 40 mm graded aggregate in foundation,filling and mass concrete all as specified. |
| 59 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil. |
| 60 | M&L for providing 100 mm thick cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base all as specified and as directed. |
| 61 | M&L for 25 mm thick sand filling undder floors or in foundations uncluding watering and consolidation |
| 62 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment |
| 63 | M&L for providing cement concrete type C1 1:3:6 using 20 mm graded stine aggreagate as in copings, kneelers, apex stones, bed plates, kerbs complete all as specified. |
| 64 | Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified. |
| 65 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil. |
| 66 | M&L for rendering 10 mm thick on brick wall or concrete surface in cement mortar 1:4 finished even & fair all as specified and directed. |
| 67 | M&L for preparation of new plastered surface of walls and applying two coats of cement base paint complete all as specified and directed. |
| 68 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm |
| 69 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point as in soils. |
| 70 | M&L for brick work in cement mortar 1:4 with burnt clay sub class \"B\" bricks straight or curved on plan exc 6m mean radius with old size bricks complete all as specified & directed. |
| 71 | M & L 15mm thick rendering in CM ( 1 : 4 ) on fair faces of brick walls or concrete surfaces etc. and finished even & smooth without using extra cement complete all as specified. |
| 72 | M & L 15mm thick rendering in CM ( 1 : 4 ) on other than fair faces of brick walls or concrete surfaces etc. and finished even & fair without using extra cement complete all as specified. |
| 73 | M&L for PCC 1:2:4 type B-2 (using 40mm graded stone agg) as in surface channel bed/drains/in manholesall as specified laid to slope and finished surface even and smooth complete all as specified & directed. |
| 74 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement incl forms moulds, mitered/stopped ends etc. complete all as specified & directed. |
| 75 | Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto as item No 08 above. |
| 76 | M&L for PCC 1:2:4 Type B-2 (using 40mm graded stone agg) over NP-3 Pipe as in mass concreteetc complete all as specified & directed. |
| 77 | S&F for 600mm bore of pipe Reinforced concrete pipes, class NP-3 with one collar per length of pipe complete all as specified & directed. |
| 78 | Demolition of brick work built in cement mortar including all quoins, asches, pillars etc in any position complete all as specified and as directed. |
| 79 | M&L for brick workwith old size burnt clay sub class \"B\"bricks built in CM 1:6 straight or curved on plan exc 6 m mean radius complete all as specified and directed. |
| 80 | M&L for 10mm thick rendering in cement mortar (1:6) on fair faces ofbrick of boundry wall concrete surfaces finished the surface even and fair without using extra cement complete all as specified |
| 81 | M&L for 15mm thick rendering in cement mortar (1:6) on other than fair faces ofbrick/ concrete surfaces of finishing the surface even and fair without using extra cement complete all as specified. |
| 82 | M&L for preparation of new plastered surface of walls and applying two coats of cement base paint over and including a coat of alkali resistant primer complete all as specified and as directed. |
| 83 | Demolition of cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for coping etc complete all as specified and as directed. |
| 84 | Demolition of reinforced cement Concreteof any description and in any position such as foundation, column, beams etc complete all as specified and as directed. |
| 85 | M&L RCC M-25 (20mm graded aggregate) deign mix as in foundation, including rafts footing , plinth beams, base for columns etc complete all as specified and directed. |
| 86 | M&L RCC M-25 (20mm graded aggregate) deign mix as in Columns, pillars, piers, posts and struts etc complete all as specified and directed. |
| 87 | M&L RCC M-25 (20mm graded aggregate) deign mix as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 88 | M&L forForm work to sides of concrete foundations, footings, bases of columns, raft, and raft beaams sidesand soffits of foundation and plinth beams and similar work and fair finished surfaces etc complete. |
| 89 | M&L forForm work to sides of pillars, posts, struts, piers, columns and stanchions etc and fair finished surfaces complete. |
| 90 | M&L forForm work to sides of concrete sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. work and fair finished surfaces etc complete. |
| 91 | S&FMild steel TMT bars 10mm dia & over cut to length bend to shape required including cranking bending spirally for hooping & binding withmild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed |
| 92 | M&L mild steel TMT bars 5mm dia and over upto and including 10mm dia, cut to length bent to shape required including cranking, bending spirally in stirrups, spacers and binders and binding with and including mild steel wire (anealed) not less than 0.9mm dia or securing with clips quality conforming to fe 410-S complete all as specified & directed |
| 93 | M&L for Providing, cement concrete (1:2:4) type B1 using 20 mm aggregate in copings, kneelers, apex stones, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles and throating,complete all as specified and directed. |
| 94 | S&F Mild steel work as in hand rails , half round or other section, balustersrunning bars, nosing to steps, wind ties, posts and struts in fencing incl cutting tops to shape as required, drilling holes , noching for wire , flat iron fillets for securing wiremesh etc., incl all necessary drilling, bolting or riveting etc & similar work conforming to Fe-290 Gde E-165 and all as specified. |
| 95 | S&F in repair galvanised 2 strand steel barbed wire 2.24mm, dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provn of galvanised mild steel wire staples or steel pins all as directed. (Each line wire to be measured) |
| 96 | M&L for 3 core multistranded copper conductor 2.5 sqmm, PVC insulated and PVC round sheathed, multicore, 1100 volts, including with use of PVC conduit pipe with junction box and accessories fixed on wall/ roof complete all as specified and as directed. |
| 97 | M&L ceiling rose, PVC / polycarbonate, isolated body 65mm x 50mm three terminals complete all as specified. |
| 98 | Supply & fixing indoor decorative ultra slim surface /Wall mounted T5 LEDbatten tube light complete fitting 1x 20 watt LED Tube fitting with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- relatedcolour temperature (CCT) of 6500K, >100 Lm/Wattcomplete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. |
| 99 | S&F MCB distribution board, SPN 4 way, double door, sheet steel, |
| 100 | S&F MCB SPN, 32 Amps, \"C\" series, breaking cap 10 kA, 240V in MCB DB complete with electrical connection all as specified and directed. |
| 101 | S&F MCB SP, 6-32 Amps, \"C\" series, breaking cap 10 kA, 240V in MCB DB complete with electrical connection all as specified and directed. |
| 102 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core, laid in trenches / duct / fixing on walls / poles inlcuding HDPE pipe |
| 103 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth for laying of cable and getting out in soft / loose soil complete all as specified and directed by Engr-in-Charge |
| 104 | Returning, filling in including spreading, levelling, watering and well ramming excavated soilin layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been erected and tested , all as specified. |
| 105 | Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified. |
| 106 | M&L for earthlingcomplete with galvanizedsteel earth plate eletrode 60x60 cm x6.3 mm thick burred directly in ground(earth pit not less than 2.25 meters deep below ground levelwith topedge of the plate not less than 1.5 Metrsbelow normal ground level connected to galvanizedearthlead wire 4.00mm diaby meansof bolts, nutscheck nutsand washersof galvanizedironor steel all as shown in electrical plateNo.5 connected to earthlingtest pointall as specifiedand indicatedincluding testing on completionincludingexcavation and arth workPCC pit &RCC pit over funnel with wateringpipe wire mesh GI protection pipe etc complete. |