| 1 | Rate in Rupees per Year for FIRST YEARAMC for Split, Cassette, Tower and Window air conditioning systems. |
| 2 | Comprehensive AMC of 1.5/2.0 TR SplitAC ,Inverter Type (Including all spares) |
| 3 | Comprehensive AMC of 1.5/2.0 TR SplitAC ,Non-Inverter Type (Including all spares) |
| 4 | Comprehensive AMC of 1.5/2.0 TR WindowAC ,Non-Inverter Type, (Including all spares) |
| 5 | Comprehensive AMC of 1.5/2.0 TR SplitAC Inverter Type (Including PCB all spares and excluding compressor) |
| 6 | Service charges for1.5/2.0 TR SplitAC (Inverter/ Non-Inverter Type)filter cleaning ,dry and wet cleaning (Machines are in warranty) |
| 7 | Comprehensive AMC of 3 TR cassette AC (Including all spares) |
| 8 | Comprehensive AMC of4 TR cassette AC(Including all spares) |
| 9 | Comprehensive AMC of4 TR Tower AC (Including all spares) |
| 10 | Rate in Rupees per Year for SECOND YEARAMC for Split, Cassette, Tower and Window air conditioning systems. |
| 11 | Comprehensive AMC of 1.5/2.0 TR SplitAC ,Inverter Type (Including all spares) |
| 12 | Comprehensive AMC of 1.5/2.0 TR SplitAC ,Non-Inverter Type (Including all spares) |
| 13 | Comprehensive AMC of 1.5/2.0 TR WindowAC ,Non-Inverter Type, (Including all spares) |
| 14 | Comprehensive AMC of 1.5/2.0 TR SplitAC Inverter Type (Including PCB all spares and excluding compressor) |
| 15 | Service charges for1.5/2.0 TR SplitAC (Inverter/ Non-Inverter Type)filter cleaning ,dry and wet cleaning (Machines are in warranty) |
| 16 | Comprehensive AMC of 3 TR cassette AC (Including all spares) |
| 17 | Comprehensive AMC of4 TR cassette AC(Including all spares) |
| 18 | Comprehensive AMC of4 TR Tower AC (Including all spares) |
| 19 | Rate in Rupees per Year for THIRD YEARAMC for Split, Cassette, Tower and Window air conditioning systems. |
| 20 | Comprehensive AMC of 1.5/2.0 TR SplitAC ,Inverter Type (Including all spares) |
| 21 | Comprehensive AMC of 1.5/2.0 TR SplitAC ,Non-Inverter Type (Including all spares) |
| 22 | Comprehensive AMC of 1.5/2.0 TR WindowAC ,Non-Inverter Type, (Including all spares) |
| 23 | Comprehensive AMC of 1.5/2.0 TR SplitAC Inverter Type (Including PCB all spares and excluding compressor) |
| 24 | Service charges for1.5/2.0 TR SplitAC (Inverter/ Non-Inverter Type)filter cleaning ,dry and wet cleaning (Machines are in warranty) |
| 25 | Comprehensive AMC of 3 TR cassette AC (Including all spares) |
| 26 | Comprehensive AMC of4 TR cassette AC(Including all spares) |
| 27 | Comprehensive AMC of4 TR Tower AC (Including all spares) |
| 28 | Rate in Rupees per Year for FIRSTyearAMC for Package ac system (2X60TR) |
| 29 | Packaged condensing unit, make- TRANEModel - RAUP-600, capacity - 60TR,Contains 4 nos. of 15TR scroll compressors, Strainers, safety devices, Refrigerant gas,2 condensing coils, 6 nos. of cooling fans, Electrical circuitry, gas pipe lines, valves, etc.(2 Sets)along with,AHU for Auditorium, Double skinned AHU Capacity- 35700 cfm at 75mm wg, With heaters, Expansion Valve, safety devices, gauges, AHU ducts Dampers, etc. & blower with motor- 18.5KW (25HP), make-Crompton Greaves, Current- 33A(2 Sets- One Units), and Associated Electrical panel for the above systems. |
| 30 | Rate in Rupees per Year for SECOND YEARAMC for Package ac system (2X60TR) |
| 31 | Packaged condensing unit, make- TRANEModel - RAUP-600, capacity - 60TR,Contains 4 nos. of 15TR scroll compressors, Strainers, safety devices, Refrigerant gas,2 condensing coils, 6 nos. of cooling fans, Electrical circuitry, gas pipe lines, valves, etc.(2 Sets)along with,AHU for Auditorium, Double skinned AHU Capacity- 35700 cfm at 75mm wg, With heaters, Expansion Valve, safety devices, gauges, AHU ducts Dampers, etc. & blower with motor- 18.5KW (25HP), make-Crompton Greaves, Current- 33A(2 Sets- One Units), and Associated Electrical panel for the above systems. |
| 32 | Rate in Rupees per Year for THIRD YEARAMC for Package ac system (2X60TR) |
| 33 | Packaged condensing unit, make- TRANEModel - RAUP-600, capacity - 60TR,Contains 4 nos. of 15TR scroll compressors, Strainers, safety devices, Refrigerant gas,2 condensing coils, 6 nos. of cooling fans, Electrical circuitry, gas pipe lines, valves, etc.(2 Sets)along with,AHU for Auditorium, Double skinned AHU Capacity- 35700 cfm at 75mm wg, With heaters, Expansion Valve, safety devices, gauges, AHU ducts Dampers, etc. & blower with motor- 18.5KW (25HP), make-Crompton Greaves, Current- 33A(2 Sets- One Units), and Associated Electrical panel for the above systems. |
| 34 | Rate in Rupees per Year for FIRST YEARAMC for Re-circulating laboratory Chillers ( 0.1 TR to 2TR) |
| 35 | Re-circulating laboratory Chillers ( 0.1 TR to 2TR) |
| 36 | Rate in Rupees per Year for SECOND YEARAMC for Re-circulating laboratory Chillers ( 0.1 TR to 2TR) |
| 37 | Re-circulating laboratory Chillers ( 0.1 TR to 2TR) |
| 38 | Rate in Rupees per Year for THIRD YEARAMC for Re-circulating laboratory Chillers ( 0.1 TR to 2TR) |
| 39 | Re-circulating laboratory Chillers ( 0.1 TR to 2TR) |