}

IT and Telecommunications, Computers, Work Station, Medical Related Equipment and Supplies, Medical Equipments, Medical Equipment-Maharashtra

Public Health Department. has published IT and Telecommunications, Computers, Work Station, Medical Related Equipment and Supplies, Medical Equipments, Medical Equipment. Submission Date for this Tender is 03-12-2013. Work Station Tenders in Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

5279705
IT and Telecommunications, Computers, Work Station, Medical Related Equipment and Supplies, Medical Equipments, Medical Equipment
Tender
Indian
Maharashtra
03-12-2013

Tender Details

Supply Of A. Basic Unit:General Description:-The Unit Should Be A Cost-Effective, Flexible Anaesthesia Workstation For Performing And Monitoring Inhalation Anaesthesia, Suitable For Adult As Well Child Upto Neonatal Age. It Should Be Capable Of Providing Low-Flow Techniques To Minimize Gas And Anaesthetic Agent Consumption For Economical Day-To-Day Operationintegrated Systems:-The Anaesthesia Workstation Should Havea. In-Built & Intergated Ventilator With Coloured Tft Display,B. Intergareted Co2 Absorber,C. In-Built & Intergated Anaesthesia Gas Monitoring Facility D.Multi Parameter Monitor E.All These Components Should Be Of The Same Manufacturer Or Brand With Their Label On Each Component.Gas Supply:-The Unit Should Be Able To Connect To Central Pipeline & There Should Be Provision Of One Pin Index Yoke To Connect To One Emergnecy Gas Cylinder Of O2 & N2o Each.Trolley:-The Unit Should Have Powder Coated Steel Trolley With 4 Wheels & 2 Drawers & The Front Wheels Should Have Locking Device. The Unit Should Have Rail On One Side To Mount Other Equipments.Flow Meters:-Machine Should Provide Electronic Gas Mixing With Cascade Type Flow Meters .Hypoxia Guard:-It Should Have Proven Hypoxia Guard Design Using The Pin-Valve Mechanism.The Unit Should Equipped With Integrated Ratio System To Maintain 25 Vol% O2 In Fresh Gas & On Accidental Opening Of Only N2o Flow With O2 Valve Closed, The Ratio System Should Automatically Open O2 Valve To Maintain 25 Vol% O2 In Fresh Gas.Water & Particle Trap:-The Unit Should Have Water & Particle Trap To The Inlet Central Gas Pipe-Line Connections Of O2, N2o & Air.Patient Module:-It Should Have Fully Autoclavable Patient Module Having Anodized Metallic Casing. It Should Have 34?C Heated Patient Module To Deliver Warm Fresh Gas To Patient & To Prevent Condensation.The Patient Module Should Have Pressure Graduated Metallic Apl Valve, Inspiratory Valve, Expiratory Valve ,A Controlled Room Air Valve & Active Gas Scavenging Port. Co2 Absorber:- Patient Module Should Be Integrated To The Co2 Absorber Of 1.4 Kg & Co2 Absorber Should Be Single/Double Chamber Design Having Screw Type Threading For Easy Removal & Re-Fitting During The Operation.O2 Flush:-The Unit Should Have O2 Flush Facility To Give Approximately 50Ltr/Min Flow.Common Gas Outlet:-The Unit Should Have Common Gas Outlet For Using Open Circuit & The Unit Should Have Easy Change Over From Open Circuit To Closed Circuit Or Vice-Versa.Vaporizers:-It Should Have Provision To Connect Two Selectatec Mount Vaporizers & The Unit Should Be Provided With Two Vaporizers Equivalent To Tec-7 Type ,One Of Isoflurane & One Of Sevoflurane.

Key Value

Document Fees
INR 2000 /-
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail